I want to search for...
Permit #2025040141
Permit Details
Status: COED
| Parcel Id: 42-10-30-3210-00000-1780 |
| CONDITIONED SPACE: 3196 sqft |
| GARAGE: 597 sqft |
| OPENED PORCH (WITH ROOF) : 518 sqft |
| Total Square Footage: 4311 sqft |
| Block: 00000 |
| Subdivision: - |
| Job Phone: 386-236-4133 |
| Location Address: 413 BOURGANVILLE DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 05/16/2025 |
| NOC: RECORDED |
| Applicant name: LEONARDO CIRO SANCLEMENTE |
| Owner: VOLUSIA RESIDENTIAL CONSTRUCTION LLC |
|
Address 2379 BEVILLE ROAD DAYTONA BEACH, FL 32119 |
| Lot: 1780 |
| Contracted Stated Job Value: ¤353,893.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
VOLUSIA RESIDENTIAL CONSTRUCTION, LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
2379 BEVILLE RD DAYTONA BEACH, FL 32119 |
CBC1262114 (Exp: 08/31/2026) | 386-236-4133 |
Sub Contractors
HUGH MACDONALD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
10825 TOM FOLSOM ROAD, SUITE A THONOTOSASSA, FL 33592 |
CCC1329562 (Exp: 08/31/2026) | 813-986-4968 |
STEPHEN COURTEAUX
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
85 North Yonge Street Ormond Beach, FL 32174 |
EC13001748 (Exp: 08/31/2026) | (386) 672-4900 | 386-676-7472 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
TIMUR ISPARYAN
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
3665 SPRINK PARK ROAD JACKSONVILLE , FL 32207 |
CMC1249968 (Exp: 08/31/2026) | 904-245-1818 | 904-337-1910 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 10/17/2025 | FINAL APPROVED | HCAMACHO |
| Note: 10/16/2025 - PREVIOUS INSPECTION NOTES 1. Both AH #1 & #2 need to have 30 amp breakers.NEC 440.4 2. WH needs a locking breaker or service disconnect.NEC 422.31 &110.25 | |||
| BLD - BUILDING FINAL | 10/16/2025 | Disapproved - NO FEE | HCAMACHO |
| Note: 1. Both AH #1 & #2 need to have 30 amp breakers.NEC 440.4 2. WH needs a locking breaker or service disconnect.NEC 422.31 &110.25 | |||
| U-CROSS CONNECTION | 10/16/2025 | APPROVED - AS NOTED | BHAINES |
| Note: No CC, Pond fed | |||
| ROW - FINAL APRON (AFTER POUR) | 10/16/2025 | APPROVED | EMADISON |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - STORMWATER FINAL | 10/16/2025 | APPROVED | EMADISON |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| U -UTILITY RESIDENTIAL FINAL | 10/16/2025 | FINAL APPROVED | BHAINES |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 10/15/2025 | APPROVED | EMADISON |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 10/15/2025 | APPROVED - AS NOTED | EMADISON |
| Note: ** 10/15/25 BEFORE THE ROW STORMWATER FINAL IS APPROVED BUILDER IS REQUIRED TO INSTALL SOD FROM THE BACK SIDE OF CURB AND GUTTER 5 FT ACROSS THE VACANTS SEE PINK PAINT FOR HIGH LIGHTED AREA CAN NOT BE SEED AND STRAW ** IN REAR BOTH SIDE OF VACANTS NEED TO INSTALL SOD ON SLOPE TO PREVENT WASH-OUTS AND EROSION CAN NOT BE SEED AND STRAW ** ALL POP-UP DRAINS ARE REQUIRED TO BE ONTOP OF THE SOD TO PREVENT EROSION FROM OCCURING FROM UNDERNEATH THE SOD ** LEFT SIDE NEED TO ENSURE SOD AROUND THE UTILITY BOX AT PROPERTY LINE | |||
| ELECTRIC - EARLY POWER | 09/08/2025 | APPROVED | MCONTRYMAN |
| ROW- PRE-APRON (PRE-POUR) | 08/18/2025 | APPROVED - AS NOTED | EMADISON |
| Note: ** 08/18/25 READY TO SET PAVERS _______________________________________________________________________________________________________________ 8/12/2025 - PREVIOUS INSPECTION NOTES ** 08/12/25 READY TO POUR APRON AND PAVER RESTRAINTS ** At the time of the inspection all minimum city requirements were met. It is the builder’s responsibility to ensure that nothing changes after this Inspection is approved. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE ** SCHEDULE NEXT PRE-POUR ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET PAVERS UNTIL NEXT PRE-POUR HAS BEEN APPROVED ____________________________________________________________________________________________________________________ | |||
| ROW- PAVER RESTRAINTS | 08/12/2025 | APPROVED | EMADISON |
| Note: ** 08/12/25 READY TO POUR PAVER RESTRAINTS AND APRON ** At the time of the inspection all minimum city requirements were met. It is the builder’s responsibility to ensure that nothing changes after this Inspection is approved. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE ____________________________________________________________________________________________________________________ | |||
| ROW- PRE-APRON (PRE-POUR) | 08/12/2025 | PARTIALLY APPROVED | EMADISON |
| Note: ** 08/12/25 READY TO POUR APRON AND PAVER RESTRAINTS ** At the time of the inspection all minimum city requirements were met. It is the builder’s responsibility to ensure that nothing changes after this Inspection is approved. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE ** SCHEDULE NEXT PRE-POUR ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET PAVERS UNTIL NEXT PRE-POUR HAS BEEN APPROVED ____________________________________________________________________________________________________________________ | |||
| LATH/BRICK/ WATER BARRIER | 07/31/2025 | APPROVED | HCAMACHO |
| GRAVITY SEWER TEST | 07/30/2025 | APPROVED | MGIBSON |
| SEWER TIE IN | 07/30/2025 | APPROVED | MGIBSON |
| INSULATION | 07/30/2025 | APPROVED | HCAMACHO |
| ELECTRIC-TUG | 07/28/2025 | APPROVED | HCAMACHO |
| GRAVITY SEWER TEST | 07/28/2025 | CANCELLED BY APPLICANT | WEB |
| ALL ROUGH | 07/25/2025 | APPROVED | JSTEWART |
| WINDOW NAILING | 07/24/2025 | APPROVED | JSTEWART |
| Note: 7/18/2025 - PREVIOUS INSPECTION NOTES 1. All the Arch windows are missing anchors, including the 1st floor and 2nd floor. 2. No product Approval sheet or installations instructions onsite to verify windows. 3. The bottom sill anchors on the slidding glass doors are all covered up or missing, can not verify. | |||
| WINDOW NAILING | 07/18/2025 | Disapproved - NO FEE | HCAMACHO |
| Note: 1. All the Arch windows are missing anchors, including the 1st floor and 2nd floor. 2. No product Approval sheet or installations instructions onsite to verify windows. 3. The bottom sill anchors on the slidding glass doors are all covered up or missing, can not verify. | |||
| ROOF VALLEY & METAL | 07/10/2025 | APPROVED | HCAMACHO |
| Note: Inspector Notes from Inspection 2460 Note- Designate an attic access on the second floor. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/08/2025 | APPROVED - AS NOTED | HCAMACHO |
| Note: Note- Designate an attic access on the second floor. | |||
| WALL SHEATHING | 07/03/2025 | APPROVED | HCAMACHO |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/03/2025 | Disapproved - NO FEE | HCAMACHO |
| Note: 1. Missing Engineering on F11,F8,F9,F5T,F6T, F7. 2. 1st Floor Bearing wall missing Attachemnts, See Plan Marked. 3. 1st Floor Detail E on Truss, See Plan Marked. 4. 1st Floor Detai 1 Post missing attachements, See Plan Marked. 5. 1st Floor Trusses See DETAIL B/FR2 OPTION 1. Marked on Plan. 6. 2nd Floor Slider Header and King posts, Missing attachemnts. See Plan Marked. | |||
| TIE BEAM / LINTEL | 06/16/2025 | APPROVED | JSTEWART |
| MONOLITHIC SLAB | 06/05/2025 | APPROVED | JSTEWART |
| Note: 6/2/2025 - PREVIOUS INSPECTION NOTES Form board survey needs to be submitted and approved prior to Monolithic slab approval. Re inspection is required. | |||
| FORMBOARD SURVEY (OFFICE USE ONLY) | 06/04/2025 | APPROVED | RRICKS |
| MONOLITHIC SLAB | 06/02/2025 | Disapproved - NO FEE | JSTEWART |
| Note: Form board survey needs to be submitted and approved prior to Monolithic slab approval. Re inspection is required. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 05/29/2025 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 05/29/2025 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 09/16/2025 | 09/17/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 07/15/2025 | 07/15/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 06/17/2025 | 06/17/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 06/17/2025 | 06/17/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 06/03/2025 | 06/04/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 06/03/2025 | 06/04/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 05/23/2025 | 05/27/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 05/05/2025 | 05/09/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 04/30/2025 | 05/05/2025 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/30/2025 | 04/30/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 04/30/2025 | 05/05/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 04/30/2025 | 05/05/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM All structural plans need to be digitally signed, sealed, and verifiable. 2nd Request | |||
| SW1 | HOLD | 04/16/2025 | 04/16/2025 |
| Note: Held By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM Disregard previous hold comments: After conversations with engineering, we will be reviewing these lots as infill lots. New comments: 1 - On site benchmark shall be referenced in NAVD 1988. 2- Proposed and existing elevations shall be depicted every 20'. 3- Lot drainage features should be clearly depicted with proposed elevations and flow arrows. Please feel free to call or email me if you have any further questions. | |||
| URB | COMPLETE | 04/03/2025 | 04/09/2025 |
| Note: Released By: MATTHEW SIERRA - (386)286-2002 - MSIERRA@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 04/02/2025 | 04/08/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | HOLD | 04/02/2025 | 04/08/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM All structural plans need to be digitally signed, sealed, and verifiable. | |||
| CUSVC | COMPLETE | 04/02/2025 | 04/09/2025 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 04/02/2025 | 04/07/2025 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit electrical load calcs. | |||
| ENGIN1 | COMPLETE | 04/02/2025 | 04/02/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 04/02/2025 | 04/04/2025 |
| LOCATE | COMPLETE | 04/02/2025 | 04/08/2025 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 04/02/2025 | 04/08/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 04/02/2025 | 04/15/2025 |
| Note: Held By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM Site plan does not agree with master plan on file. Please attach City modification letter or match approved master plan. | |||
| ZON | HOLD | 04/02/2025 | 04/03/2025 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Garage depth cannot exceed 30ft |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 10/15/2025 |
| PLAN REVIEW - REVISION | ¤32.50 | 10/15/2025 |
| CONTRACTOR CHANGE | ¤20.00 | 10/15/2025 |
| FC IMPACT FEE EMS | ¤62.00 | 05/16/2025 |
| IMPACT FEE FIRE | ¤434.51 | 05/16/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 05/16/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 05/16/2025 |
| IMPACT FEE PARKS | ¤1,828.01 | 05/16/2025 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 05/16/2025 |
| IMPACT FEE TRANSPORTATION | ¤3,502.00 | 05/16/2025 |
| WATER METER W/OUT TAP | ¤965.03 | 05/16/2025 |
| SURCHARGE FS 533.721 | ¤19.59 | 05/16/2025 |
| SURCHARGE - FS 468.631 | ¤29.38 | 05/16/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 05/16/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 05/16/2025 |
| SW ENG PRE APRON | ¤30.00 | 05/16/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 05/16/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 05/16/2025 |
| WASTEWATER PERM INSPECTION | ¤40.00 | 05/16/2025 |
| WATER PERMIT REVIEW | ¤40.00 | 05/16/2025 |
| SITE PLAN 30 | ¤30.00 | 05/16/2025 |
| WATER- TURN ON | ¤50.00 | 05/16/2025 |
| ADJUSTMENT 10% | (¤217.62) | 05/16/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 05/16/2025 |
| INSPECTION - RESIDENTIAL | ¤1,672.00 | 05/16/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤474.24 | 05/16/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤15,330.14 |