I want to search for...

Permit #2025040170

Permit Details

Status: COED

Parcel Id: 07-11-31-7026-00150-0120
CONDITIONED SPACE: 1809 sqft
GARAGE: 406 sqft
OPENED PORCH (WITH ROOF) : 33 sqft
Total Square Footage: 2248 sqft
Block: 00150
Subdivision: -
Job Phone: 239-571-5325
Location Address: 23 PINELAND LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/14/2025
NOC: RECORDED
Applicant name: RYAN SCOTT DAVIS
Owner: SYNERGY HOMES LLC

Address

581 NW MERCANTILE PLACE SUITE 106

PORT ST LUCIE, FL 34986

Lot: 0120
Contracted Stated Job Value: ¤200,000.00
Job Description: Single Family Residence
Type: CN

Contractor

SYNERGY HOMES, LLC
Status Location Address State License Number
ACTIVE

1 HARGROVE GRADE, SUITE B1

PALM COAST, FL 32137

CBC1254289 (Exp: 08/31/2026)

Sub Contractors

TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733
MICHAEL FRANK MORELLO
Status Location Address State License Number Phone Fax
ACTIVE

2 HARGROVE GRADE

PALM COAST, FL 32164

CAC1819466 (Exp: 08/31/2026) 386-445-5023 386-446-4614
WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 08/22/2025 FINAL APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 8/22/2025 12:42:13 PM *** 8/21/2025 - PREVIOUS INSPECTION NOTES 8/21/25: Could not fully complete inspection due to breaker being off. 1). Breaker at spot 24 is turned off (upon arrival) Listed as Master Bedroom / Smokes. No lights in Master bedroom, closet & bathroom (lights & fan). 2). No power to garage door opener. Could not inspect/test. FBC-[A] 110.1 3). Garage: Hole in wall at low voltage needs to be repaired with approved material as required by FBC-302.6 4). Garbage Disposal and Dishwasher are unplugged upon arrival. Could not inspect/test. FBC-[A] 110.1 5). Downspout must terminate 12" minimum from Building as required by FBC-R318.5
BLD - BUILDING FINAL 08/21/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 8/21/2025 12:22:59 PM *** 8/21/25: Could not fully complete inspection due to breaker being off. 1). Breaker at spot 24 is turned off (upon arrival) Listed as Master Bedroom / Smokes. No lights in Master bedroom, closet & bathroom (lights & fan). 2). No power to garage door opener. Could not inspect/test. FBC-[A] 110.1 3). Garage: Hole in wall at low voltage needs to be repaired with approved material as required by FBC-302.6 4). Garbage Disposal and Dishwasher are unplugged upon arrival. Could not inspect/test. FBC-[A] 110.1 5). Downspout must terminate 12" minimum from Building as required by FBC-R318.5
U -UTILITY RESIDENTIAL FINAL 08/20/2025 FINAL APPROVED LFITZGERALD
Note: Inspector Notes from Inspection 9035 no irr-no cc
ROW - FINAL APRON (AFTER POUR) 08/19/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/19/2025 APPROVED TPOLACEK
ROW FIELD SURVEY /GRADING CERTIFICATION 08/19/2025 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - STORMWATER FINAL 08/19/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ELECTRIC - EARLY POWER 08/15/2025 APPROVED CVANSTRAHLEN
Note: Approved July14 for early power
ROW- PRE-APRON (PRE-POUR) 08/01/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. 7/30/2025 - PREVIOUS INSPECTION NOTES 07/30/25 TPOLACEK**** CULVERT IS STILL OUT OF TOLERENCE AND PICHED IN THE WRONG DIRECTION. 2 Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 7/29/2025 - PREVIOUS INSPECTION NOTES 07/29/25 TPOLACEK*** BUILDER WAS ON SITE TRYING TO MAKE CORRECTIONS. THE PIPE IS STILL OUT OF TOLERENCE BUT THERY ARE WORKING ON IT SO I WILL NOT FEE FOR THIS INSPECTION. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 7/25/2025 - PREVIOUS INSPECTION NOTES 07/25/25 TPOLACEK*** POUR AREA WSHOUT OUT INTO FOOTERS, ROADSIDE FORM BOARD STILL DOWN FROM LAST WEEK. WATER IN POUR AREA EXCEEDS ALLOWABLE LIMIT. 7/24/2025 - PREVIOUS INSPECTION NOTES 07/24/25 TPOLACEK*** CM REQUESTED TO CANCEL INSPECTION DUE TO POUR AREA HOLDING TOO MUCH WATER. 7/22/2025 - PREVIOUS INSPECTION NOTES 07/22/25 TPOLACEK*** POUR AREA WASHED OUT AND HOLDING WATER. NOT READY FOR INSPECTION/REINSPECTIONS FEES. Sec. 900.09 F V-67 Sec. 900.09-F Permittee shall be charged an additional fee for each re-inspection required should the permittee call for an inspection and NOT be prepared for the requested inspection. 7/21/2025 - PREVIOUS INSPECTION NOTES 07/21/25 TPOLACEK*** CULVERT ELEVATION IS GOOD AT THIS TIME, FORM BOARD ALONG ROADSIDE EDGE IS DOWN AS WELL AS THE LEFT MITERED END BOARD, FOOTERS ARE WASHED IS AND NEED TO BE REESTABLISHED. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 7/17/2025 - PREVIOUS INSPECTION NOTES TPOLACEK*** RECIEVED TEXT FROM CM ASKING TO CANCEL INSPECTION FOR TODAY 7/14/2025 - PREVIOUS INSPECTION NOTES 07/14/25 TPOLACEK*** RECIEVED TEXT FROM CM ASKING TO CANCEL INSPECTION FOR TODAY
ROW- PRE-APRON (PRE-POUR) 07/30/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 07/30/25 TPOLACEK**** CULVERT IS STILL OUT OF TOLERENCE AND PICHED IN THE WRONG DIRECTION. 2 Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 7/29/2025 - PREVIOUS INSPECTION NOTES 07/29/25 TPOLACEK*** BUILDER WAS ON SITE TRYING TO MAKE CORRECTIONS. THE PIPE IS STILL OUT OF TOLERENCE BUT THERY ARE WORKING ON IT SO I WILL NOT FEE FOR THIS INSPECTION. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 7/25/2025 - PREVIOUS INSPECTION NOTES 07/25/25 TPOLACEK*** POUR AREA WSHOUT OUT INTO FOOTERS, ROADSIDE FORM BOARD STILL DOWN FROM LAST WEEK. WATER IN POUR AREA EXCEEDS ALLOWABLE LIMIT. 7/24/2025 - PREVIOUS INSPECTION NOTES 07/24/25 TPOLACEK*** CM REQUESTED TO CANCEL INSPECTION DUE TO POUR AREA HOLDING TOO MUCH WATER. 7/22/2025 - PREVIOUS INSPECTION NOTES 07/22/25 TPOLACEK*** POUR AREA WASHED OUT AND HOLDING WATER. NOT READY FOR INSPECTION/REINSPECTIONS FEES. Sec. 900.09 F V-67 Sec. 900.09-F Permittee shall be charged an additional fee for each re-inspection required should the permittee call for an inspection and NOT be prepared for the requested inspection. 7/21/2025 - PREVIOUS INSPECTION NOTES 07/21/25 TPOLACEK*** CULVERT ELEVATION IS GOOD AT THIS TIME, FORM BOARD ALONG ROADSIDE EDGE IS DOWN AS WELL AS THE LEFT MITERED END BOARD, FOOTERS ARE WASHED IS AND NEED TO BE REESTABLISHED. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 7/17/2025 - PREVIOUS INSPECTION NOTES TPOLACEK*** RECIEVED TEXT FROM CM ASKING TO CANCEL INSPECTION FOR TODAY 7/14/2025 - PREVIOUS INSPECTION NOTES 07/14/25 TPOLACEK*** RECIEVED TEXT FROM CM ASKING TO CANCEL INSPECTION FOR TODAY
ROW- PRE-APRON (PRE-POUR) 07/29/2025 Disapproved - NO FEE TPOLACEK
Note: 07/29/25 TPOLACEK*** BUILDER WAS ON SITE TRYING TO MAKE CORRECTIONS. THE PIPE IS STILL OUT OF TOLERENCE BUT THERY ARE WORKING ON IT SO I WILL NOT FEE FOR THIS INSPECTION. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 7/25/2025 - PREVIOUS INSPECTION NOTES 07/25/25 TPOLACEK*** POUR AREA WSHOUT OUT INTO FOOTERS, ROADSIDE FORM BOARD STILL DOWN FROM LAST WEEK. WATER IN POUR AREA EXCEEDS ALLOWABLE LIMIT. 7/24/2025 - PREVIOUS INSPECTION NOTES 07/24/25 TPOLACEK*** CM REQUESTED TO CANCEL INSPECTION DUE TO POUR AREA HOLDING TOO MUCH WATER. 7/22/2025 - PREVIOUS INSPECTION NOTES 07/22/25 TPOLACEK*** POUR AREA WASHED OUT AND HOLDING WATER. NOT READY FOR INSPECTION/REINSPECTIONS FEES. Sec. 900.09 F V-67 Sec. 900.09-F Permittee shall be charged an additional fee for each re-inspection required should the permittee call for an inspection and NOT be prepared for the requested inspection. 7/21/2025 - PREVIOUS INSPECTION NOTES 07/21/25 TPOLACEK*** CULVERT ELEVATION IS GOOD AT THIS TIME, FORM BOARD ALONG ROADSIDE EDGE IS DOWN AS WELL AS THE LEFT MITERED END BOARD, FOOTERS ARE WASHED IS AND NEED TO BE REESTABLISHED. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 7/17/2025 - PREVIOUS INSPECTION NOTES TPOLACEK*** RECIEVED TEXT FROM CM ASKING TO CANCEL INSPECTION FOR TODAY 7/14/2025 - PREVIOUS INSPECTION NOTES 07/14/25 TPOLACEK*** RECIEVED TEXT FROM CM ASKING TO CANCEL INSPECTION FOR TODAY
ROW- PRE-APRON (PRE-POUR) 07/25/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 07/25/25 TPOLACEK*** POUR AREA WSHOUT OUT INTO FOOTERS, ROADSIDE FORM BOARD STILL DOWN FROM LAST WEEK. WATER IN POUR AREA EXCEEDS ALLOWABLE LIMIT. 7/24/2025 - PREVIOUS INSPECTION NOTES 07/24/25 TPOLACEK*** CM REQUESTED TO CANCEL INSPECTION DUE TO POUR AREA HOLDING TOO MUCH WATER. 7/22/2025 - PREVIOUS INSPECTION NOTES 07/22/25 TPOLACEK*** POUR AREA WASHED OUT AND HOLDING WATER. NOT READY FOR INSPECTION/REINSPECTIONS FEES. Sec. 900.09 F V-67 Sec. 900.09-F Permittee shall be charged an additional fee for each re-inspection required should the permittee call for an inspection and NOT be prepared for the requested inspection. 7/21/2025 - PREVIOUS INSPECTION NOTES 07/21/25 TPOLACEK*** CULVERT ELEVATION IS GOOD AT THIS TIME, FORM BOARD ALONG ROADSIDE EDGE IS DOWN AS WELL AS THE LEFT MITERED END BOARD, FOOTERS ARE WASHED IS AND NEED TO BE REESTABLISHED. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 7/17/2025 - PREVIOUS INSPECTION NOTES TPOLACEK*** RECIEVED TEXT FROM CM ASKING TO CANCEL INSPECTION FOR TODAY 7/14/2025 - PREVIOUS INSPECTION NOTES 07/14/25 TPOLACEK*** RECIEVED TEXT FROM CM ASKING TO CANCEL INSPECTION FOR TODAY
ROW- PRE-APRON (PRE-POUR) 07/24/2025 CANCELLED BY APPLICANT TPOLACEK
Note: 07/24/25 TPOLACEK*** CM REQUESTED TO CANCEL INSPECTION DUE TO POUR AREA HOLDING TOO MUCH WATER. 7/22/2025 - PREVIOUS INSPECTION NOTES 07/22/25 TPOLACEK*** POUR AREA WASHED OUT AND HOLDING WATER. NOT READY FOR INSPECTION/REINSPECTIONS FEES. Sec. 900.09 F V-67 Sec. 900.09-F Permittee shall be charged an additional fee for each re-inspection required should the permittee call for an inspection and NOT be prepared for the requested inspection. 7/21/2025 - PREVIOUS INSPECTION NOTES 07/21/25 TPOLACEK*** CULVERT ELEVATION IS GOOD AT THIS TIME, FORM BOARD ALONG ROADSIDE EDGE IS DOWN AS WELL AS THE LEFT MITERED END BOARD, FOOTERS ARE WASHED IS AND NEED TO BE REESTABLISHED. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 7/17/2025 - PREVIOUS INSPECTION NOTES TPOLACEK*** RECIEVED TEXT FROM CM ASKING TO CANCEL INSPECTION FOR TODAY 7/14/2025 - PREVIOUS INSPECTION NOTES 07/14/25 TPOLACEK*** RECIEVED TEXT FROM CM ASKING TO CANCEL INSPECTION FOR TODAY
ROW- PRE-APRON (PRE-POUR) 07/22/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 07/22/25 TPOLACEK*** POUR AREA WASHED OUT AND HOLDING WATER. NOT READY FOR INSPECTION/REINSPECTIONS FEES. Sec. 900.09 F V-67 Sec. 900.09-F Permittee shall be charged an additional fee for each re-inspection required should the permittee call for an inspection and NOT be prepared for the requested inspection. 7/21/2025 - PREVIOUS INSPECTION NOTES 07/21/25 TPOLACEK*** CULVERT ELEVATION IS GOOD AT THIS TIME, FORM BOARD ALONG ROADSIDE EDGE IS DOWN AS WELL AS THE LEFT MITERED END BOARD, FOOTERS ARE WASHED IS AND NEED TO BE REESTABLISHED. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 7/17/2025 - PREVIOUS INSPECTION NOTES TPOLACEK*** RECIEVED TEXT FROM CM ASKING TO CANCEL INSPECTION FOR TODAY 7/14/2025 - PREVIOUS INSPECTION NOTES 07/14/25 TPOLACEK*** RECIEVED TEXT FROM CM ASKING TO CANCEL INSPECTION FOR TODAY
ROW- PRE-APRON (PRE-POUR) 07/21/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 07/21/25 TPOLACEK*** CULVERT ELEVATION IS GOOD AT THIS TIME, FORM BOARD ALONG ROADSIDE EDGE IS DOWN AS WELL AS THE LEFT MITERED END BOARD, FOOTERS ARE WASHED IS AND NEED TO BE REESTABLISHED. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 7/17/2025 - PREVIOUS INSPECTION NOTES TPOLACEK*** RECIEVED TEXT FROM CM ASKING TO CANCEL INSPECTION FOR TODAY 7/14/2025 - PREVIOUS INSPECTION NOTES 07/14/25 TPOLACEK*** RECIEVED TEXT FROM CM ASKING TO CANCEL INSPECTION FOR TODAY
ROW- PRE-APRON (PRE-POUR) 07/17/2025 CANCELLED BY APPLICANT TPOLACEK
Note: TPOLACEK*** RECIEVED TEXT FROM CM ASKING TO CANCEL INSPECTION FOR TODAY 7/14/2025 - PREVIOUS INSPECTION NOTES 07/14/25 TPOLACEK*** RECIEVED TEXT FROM CM ASKING TO CANCEL INSPECTION FOR TODAY
ROW- PRE-APRON (PRE-POUR) 07/14/2025 CANCELLED BY APPLICANT TPOLACEK
Note: 07/14/25 TPOLACEK*** RECIEVED TEXT FROM CM ASKING TO CANCEL INSPECTION FOR TODAY
ELECTRIC - EARLY POWER 07/14/2025 APPROVED CVANSTRAHLEN
GRAVITY SEWER TEST 07/03/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 7/3/2025 12:32:10 PM ***
SEWER TIE IN 07/03/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 7/3/2025 12:31:51 PM ***
PEP TANK INSTALLATION REQUEST 06/24/2025 APPROVED CBOWERMASTER
INSULATION 06/24/2025 APPROVED RSIMS
Note: 6/23/2025 - PREVIOUS INSPECTION NOTES 6/23/25: NO CHANGE FROM PREVIOUS INSPECTION! 1). Hole in top plate for potential wire penetration is missing firestop. FBC-R302.11 Stud marked FS. This is between bedrooms 3 and 4. 6/20/2025 - PREVIOUS INSPECTION NOTES 6/20/25: 1). Hole in top plate for potential wire penetration is missing firestop. FBC-R302.11 Stud marked FS. 6/18/2025 - PREVIOUS INSPECTION NOTES 6/18/25: Cancelled by Applicant via phone at @ 10:19 Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 6/13/2025 11:34:50 AM *** 6/13/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). 5ft head pressure not holding. Please fill test pipe to the top. FBC-P2503.5.1 2). Wires are not phased out as required. NEC 215.12(C) New inspection due to canceled inspection Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 6/6/2025 12:47:51 PM *** 6/6/25: Approved as noted. CHECK AT NEXT INSPECTION. 1). Overflowing dumpster needs to be emptied so scattered trash can be cleaned up and placed in dumpster. FBC 3302.2 2). 2-ply trusses C1 and D1 are not connected as required. Marked on MiTek. FBC [A]107.4 5/30/2025 - PREVIOUS INSPECTION NOTES 5/30/25: Incomplete inspection due to incomplete Truss Engineering. NOT READY! FBC [A]107.4 NOTE: Roof sheathing (only) checked and approved.
INSULATION 06/23/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 6/23/2025 11:49:01 AM *** 6/23/25: NO CHANGE FROM PREVIOUS INSPECTION! 1). Hole in top plate for potential wire penetration is missing firestop. FBC-R302.11 Stud marked FS. This is between bedrooms 3 and 4. 6/20/2025 - PREVIOUS INSPECTION NOTES 6/20/25: 1). Hole in top plate for potential wire penetration is missing firestop. FBC-R302.11 Stud marked FS. 6/18/2025 - PREVIOUS INSPECTION NOTES 6/18/25: Cancelled by Applicant via phone at @ 10:19 Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 6/13/2025 11:34:50 AM *** 6/13/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). 5ft head pressure not holding. Please fill test pipe to the top. FBC-P2503.5.1 2). Wires are not phased out as required. NEC 215.12(C) New inspection due to canceled inspection Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 6/6/2025 12:47:51 PM *** 6/6/25: Approved as noted. CHECK AT NEXT INSPECTION. 1). Overflowing dumpster needs to be emptied so scattered trash can be cleaned up and placed in dumpster. FBC 3302.2 2). 2-ply trusses C1 and D1 are not connected as required. Marked on MiTek. FBC [A]107.4 5/30/2025 - PREVIOUS INSPECTION NOTES 5/30/25: Incomplete inspection due to incomplete Truss Engineering. NOT READY! FBC [A]107.4 NOTE: Roof sheathing (only) checked and approved.
INSULATION 06/20/2025 Disapproved - NO FEE RSIMS
Note: 6/20/25: 1). Hole in top plate for potential wire penetration is missing firtestop. FBC-R302.11 Stud marked FS. 6/18/2025 - PREVIOUS INSPECTION NOTES 6/18/25: Cancelled by Applicant via phone at @ 10:19 Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 6/13/2025 11:34:50 AM *** 6/13/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). 5ft head pressure not holding. Please fill test pipe to the top. FBC-P2503.5.1 2). Wires are not phased out as required. NEC 215.12(C) New inspection due to canceled inspection Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 6/6/2025 12:47:51 PM *** 6/6/25: Approved as noted. CHECK AT NEXT INSPECTION. 1). Overflowing dumpster needs to be emptied so scattered trash can be cleaned up and placed in dumpster. FBC 3302.2 2). 2-ply trusses C1 and D1 are not connected as required. Marked on MiTek. FBC [A]107.4 5/30/2025 - PREVIOUS INSPECTION NOTES 5/30/25: Incomplete inspection due to incomplete Truss Engineering. NOT READY! FBC [A]107.4 NOTE: Roof sheathing (only) checked and approved.
LATH/BRICK/ WATER BARRIER 06/20/2025 APPROVED RSIMS
Note: 6/18/2025 - PREVIOUS INSPECTION NOTES 6/18/25: NO CHANGE FROM PREVIOUS INSPECTION. 1). Portable toilet needs to be moved from swale area to allow free flow of water through swale. FBC 3303.5. 2). Wires are not phased out as required. NEC 215.12(C) 6/17/2025 - PREVIOUS INSPECTION NOTES 6/17/25: Previously listed item 2 remains unresolved. 1). Portable toilet needs to be moved from swale area to allow free flow of water through swale. FBC 3303.5. 2). Wires are not phased out as required. NEC 215.12(C) Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 6/13/2025 11:34:50 AM *** 6/13/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). 5ft head pressure not holding. Please fill test pipe to the top. FBC-P2503.5.1 2). Wires are not phased out as required. NEC 215.12(C) New inspection due to canceled inspection Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 6/6/2025 12:47:51 PM *** 6/6/25: Approved as noted. CHECK AT NEXT INSPECTION. 1). Overflowing dumpster needs to be emptied so scattered trash can be cleaned up and placed in dumpster. FBC 3302.2 2). 2-ply trusses C1 and D1 are not connected as required. Marked on MiTek. FBC [A]107.4 5/30/2025 - PREVIOUS INSPECTION NOTES 5/30/25: Incomplete inspection due to incomplete Truss Engineering. NOT READY! FBC [A]107.4 NOTE: Roof sheathing (only) checked and approved.
LATH/BRICK/ WATER BARRIER 06/18/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 6/18/2025 10:22:30 AM *** 6/18/25: NO CHANGE FROM PREVIOUS INSPECTION. 1). Portable toilet needs to be moved from swale area to allow free flow of water through swale. FBC 3303.5. 2). Wires are not phased out as required. NEC 215.12(C) 6/17/2025 - PREVIOUS INSPECTION NOTES 6/17/25: Previously listed item 2 remains unresolved. 1). Portable toilet needs to be moved from swale area to allow free flow of water through swale. FBC 3303.5. 2). Wires are not phased out as required. NEC 215.12(C) Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 6/13/2025 11:34:50 AM *** 6/13/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). 5ft head pressure not holding. Please fill test pipe to the top. FBC-P2503.5.1 2). Wires are not phased out as required. NEC 215.12(C) New inspection due to canceled inspection Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 6/6/2025 12:47:51 PM *** 6/6/25: Approved as noted. CHECK AT NEXT INSPECTION. 1). Overflowing dumpster needs to be emptied so scattered trash can be cleaned up and placed in dumpster. FBC 3302.2 2). 2-ply trusses C1 and D1 are not connected as required. Marked on MiTek. FBC [A]107.4 5/30/2025 - PREVIOUS INSPECTION NOTES 5/30/25: Incomplete inspection due to incomplete Truss Engineering. NOT READY! FBC [A]107.4 NOTE: Roof sheathing (only) checked and approved.
INSULATION 06/18/2025 CANCELLED BY APPLICANT RSIMS
Note: *** NOTES ADDED BY RSIMS 6/18/2025 10:23:52 AM *** 6/18/25: Cancelled by Applicant via phone at @ 10:19 Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 6/13/2025 11:34:50 AM *** 6/13/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). 5ft head pressure not holding. Please fill test pipe to the top. FBC-P2503.5.1 2). Wires are not phased out as required. NEC 215.12(C) New inspection due to canceled inspection Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 6/6/2025 12:47:51 PM *** 6/6/25: Approved as noted. CHECK AT NEXT INSPECTION. 1). Overflowing dumpster needs to be emptied so scattered trash can be cleaned up and placed in dumpster. FBC 3302.2 2). 2-ply trusses C1 and D1 are not connected as required. Marked on MiTek. FBC [A]107.4 5/30/2025 - PREVIOUS INSPECTION NOTES 5/30/25: Incomplete inspection due to incomplete Truss Engineering. NOT READY! FBC [A]107.4 NOTE: Roof sheathing (only) checked and approved.
LATH/BRICK/ WATER BARRIER 06/17/2025 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 6/17/2025 11:45:10 AM *** 6/17/25: Previously listed item 2 remains unresolved. 1). Portable toilet needs to be moved from swale area to allow free flow of water through swale. FBC 3303.5. 2). Wires are not phased out as required. NEC 215.12(C) Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 6/13/2025 11:34:50 AM *** 6/13/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). 5ft head pressure not holding. Please fill test pipe to the top. FBC-P2503.5.1 2). Wires are not phased out as required. NEC 215.12(C) New inspection due to canceled inspection Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 6/6/2025 12:47:51 PM *** 6/6/25: Approved as noted. CHECK AT NEXT INSPECTION. 1). Overflowing dumpster needs to be emptied so scattered trash can be cleaned up and placed in dumpster. FBC 3302.2 2). 2-ply trusses C1 and D1 are not connected as required. Marked on MiTek. FBC [A]107.4 5/30/2025 - PREVIOUS INSPECTION NOTES 5/30/25: Incomplete inspection due to incomplete Truss Engineering. NOT READY! FBC [A]107.4 NOTE: Roof sheathing (only) checked and approved.
ALL ROUGH 06/13/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 6/13/2025 11:34:50 AM *** 6/13/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). 5ft head pressure not holding. Please fill test pipe to the top. FBC-P2503.5.1 2). Wires are not phased out as required. NEC 215.12(C) New inspection due to canceled inspection Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 6/6/2025 12:47:51 PM *** 6/6/25: Approved as noted. CHECK AT NEXT INSPECTION. 1). Overflowing dumpster needs to be emptied so scattered trash can be cleaned up and placed in dumpster. FBC 3302.2 2). 2-ply trusses C1 and D1 are not connected as required. Marked on MiTek. FBC [A]107.4 5/30/2025 - PREVIOUS INSPECTION NOTES 5/30/25: Incomplete inspection due to incomplete Truss Engineering. NOT READY! FBC [A]107.4 NOTE: Roof sheathing (only) checked and approved.
ALL ROUGH 06/11/2025 CANCELLED BY APPLICANT WEB
Note: Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 6/6/2025 12:47:51 PM *** 6/6/25: Approved as noted. CHECK AT NEXT INSPECTION. 1). Overflowing dumpster needs to be emptied so scattered trash can be cleaned up and placed in dumpster. FBC 3302.2 2). 2-ply trusses C1 and D1 are not connected as required. Marked on MiTek. FBC [A]107.4 5/30/2025 - PREVIOUS INSPECTION NOTES 5/30/25: Incomplete inspection due to incomplete Truss Engineering. NOT READY! FBC [A]107.4 NOTE: Roof sheathing (only) checked and approved.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/06/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 6/6/2025 12:47:51 PM *** 6/6/25: Approved as noted. CHECK AT NEXT INSPECTION. 1). Overflowing dumpster needs to be emptied so scattered trash can be cleaned up and placed in dumpster. FBC 3302.2 2). 2-ply trusses C1 and D1 are not connected as required. Marked on MiTek. FBC [A]107.4 5/30/2025 - PREVIOUS INSPECTION NOTES 5/30/25: Incomplete inspection due to incomplete Truss Engineering. NOT READY! FBC [A]107.4 NOTE: Roof sheathing (only) checked and approved.
ROOF VALLEY & METAL 06/06/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 6/6/2025 12:47:35 PM ***
U-CROSS CONNECTION 06/02/2025 APPROVED - AS NOTED LFITZGERALD
Note: no irr-no cc
WALL SHEATHING 05/30/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/30/2025 12:31:15 PM ***
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/30/2025 Disapproved - NO FEE RSIMS
Note: 5/30/25: Incomplete inspection due to incomplete Truss Engineering. NOT READY! FBC [A]107.4 NOTE: Roof sheathing (only) checked and approved.
TIE BEAM / LINTEL 05/22/2025 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 5/22/2025 9:26:18 AM *** 5/22/25: 1). Dowel rods do not meet the minimum clearance (2" from face of block and/or 3/4: from inside of block) as required. (FBC-R606.3.4) Spray painted orange. Near back right window.
TIE BEAM / LINTEL 05/22/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/22/2025 10:03:55 AM *** 5/22/25: *** Correction verified via FaceTime video/audio phone app at @ 09:58. 5/22/2025 - PREVIOUS INSPECTION NOTES 5/22/25: 1). Dowel rods do not meet the minimum clearance (2" from face of block and/or 3/4: from inside of block) as required. (FBC-R606.3.4) Spray painted orange. Near back right window.
MONOLITHIC SLAB 05/15/2025 APPROVED RSIMS
Note: 5/14/2025 - PREVIOUS INSPECTION NOTES Not ready
MONOLITHIC SLAB 05/14/2025 Disapproved - NO FEE CVANSTRAHLEN
Note: Not ready
PLUMBING 1ST ROUGH UNDERGROUND 05/09/2025 APPROVED MGIBSON
Note: 5/8/2025 - PREVIOUS INSPECTION NOTES PLUMBER JUST STARTED. NOTHING TO INSPECT
PLUMBING 1ST ROUGH UNDERGROUND 05/08/2025 Disapproved -FEE REQUIRED MGIBSON
Note: PLUMBER JUST STARTED. NOTHING TO INSPECT
FORMBOARD SURVEY (OFFICE USE ONLY) 05/06/2025 APPROVED PFLANAGAN
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 05/01/2025 APPROVED PKNAPIK
WATER METER INSTALLATION REQUEST 04/25/2025 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 05/05/2025 05/05/2025
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 05/05/2025 05/05/2025
Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM
BLD COMPLETE 05/01/2025 05/01/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
ZON COMPLETE 04/11/2025 04/11/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/11/2025 04/11/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
SW1 COMPLETE 04/11/2025 04/14/2025
Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM
BADMIN COMPLETE 04/03/2025 04/09/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 04/03/2025 04/09/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 04/03/2025 04/10/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 04/03/2025 04/07/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/03/2025 04/03/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 04/03/2025 04/08/2025
LOCATE COMPLETE 04/03/2025 04/08/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 04/03/2025 04/08/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 04/03/2025 04/09/2025
Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM
ZON HOLD 04/03/2025 04/04/2025
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Site plan missing walkway width and material
SWALE COMPLETE 04/03/2025 04/17/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 08/22/2025
REINSPECTION RESIDENTIAL ¤40.00 08/22/2025
REINSPECTION RESIDENTIAL ¤40.00 08/22/2025
REINSPECTION RESIDENTIAL ¤40.00 08/22/2025
SW ENG REINSPECTION 30 ¤30.00 08/22/2025
SW ENG REINSPECTION 30 ¤30.00 08/22/2025
SW ENG REINSPECTION 30 ¤30.00 08/22/2025
SW ENG REINSPECTION 30 ¤30.00 08/22/2025
SW ENG - REVIEW 20 ¤20.00 04/14/2025
SW ENG RES REVIEW 200 ¤200.00 04/14/2025
WATER METER W/ TAP ¤2,326.93 04/14/2025
SEWER CREDIT (¤1,147.00) 04/14/2025
WASTEWATER PERM INSPECTION ¤40.00 04/14/2025
SEWER CAPITAL FACILITY ¤3,930.70 04/14/2025
WATER CAPITAL FACILITY FEE ¤3,496.74 04/14/2025
WATER PERMIT REVIEW ¤40.00 04/14/2025
WATER MAIN EXTENSION IMPACT ¤854.40 04/14/2025
SITE PLAN 30 ¤30.00 04/14/2025
WATER- TURN ON ¤50.00 04/14/2025
ADJUSTMENT 10% (¤120.20) 04/14/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/14/2025
INSPECTION - RESIDENTIAL ¤913.00 04/14/2025
PLAN REVIEW - RESIDENTIAL ¤258.96 04/14/2025
FC IMPACT FEE EMS ¤62.00 04/14/2025
IMPACT FEE FIRE ¤434.51 04/14/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 04/14/2025
FC IMPACT FEE LIBRARY ¤268.00 04/14/2025
IMPACT FEE PARKS ¤1,828.01 04/14/2025
IMPACT FEE SCHOOL ¤5,450.00 04/14/2025
IMPACT FEE TRANSPORTATION ¤1,916.00 04/14/2025
PEP TANK INSTALL ¤756.74 04/14/2025
WASTEWATER MAIN EXTENSION IMPA ¤2,189.82 04/14/2025
SURCHARGE FS 533.721 ¤10.82 04/14/2025
SURCHARGE - FS 468.631 ¤16.23 04/14/2025
SW ENG - FOUNDATION SURVEY ¤20.00 04/14/2025
SW ENG INSPECTION 80 ¤80.00 04/14/2025
SW ENG PRE APRON ¤30.00 04/14/2025
Fees Total Due: ¤0.00 Total Paid: ¤24,483.66