I want to search for...
Permit #2025040225
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7004-00010-0110 |
| CONDITIONED SPACE: 221 sqft |
| Total Square Footage: 221 sqft |
| Block: 00010 |
| Subdivision: - |
| Job Phone: 386-931-6532 |
| Location Address: 7 CHERRY CT |
| Type: BIA - BUILDING INTERIOR EXTERIOR ALTERATION |
| Issue Date: 05/05/2025 |
| NOC: RECORDED |
| Applicant name: JOSE LOPEZ |
| Owner: MAGGARD RICHARD & SARA JEAN TRUSTEES |
|
Address 7520 NW 51ST TERRACE COCONUT CREEK, FL 33073 |
| Lot: 0110 |
| Contracted Stated Job Value: ¤15,500.00 |
| Job Description: ADD NEW BATHROOM UNDER ROOF |
| Type: CN |
Contractor
JOSE LOPEZ CONSTRUCTION, INC.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
14 UTILITY DRIVE #12 BUNNELL, FL 32110 |
CRC1327719 (Exp: 08/31/2026) | (386)445-9424 |
Sub Contractors
RICHARD A MAGGARD
| Status | Location Address | State License Number | Phone |
| INACTIVE |
4911 LYONS TECHNOLOGY PKWY COCONUT CREEK, FL 33073 |
CFC057457 (Exp: 08/31/2026) | 954-427-5822 |
JONATHAN O'NEIL HALEY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
32 BRIAN LANE PALM COAST, FL 32137 |
EC13007418 (Exp: 08/31/2026) | 386-585-4716 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 10/06/2025 | FINAL APPROVED | HCAMACHO |
| Note: 9/24/2025 - PREVIOUS INSPECTION NOTES 1. Outlet in the master bath that is on the front wall vanity closest to the tub needs to be removed. NEC 406.9(C) Receptacle withing 36” radius of shower/tub 2. remove grass and dirt away from new wood frame wall and sidding. Inspector Notes from Inspection 2490 1. All the smoke detectors need to be brought up to code. Need a smoke detector in every Bedroom, and a CB/SD outside all the bedrooms. They all need to be connected. FBCR 314 & 315 *None of the bedrooms have SD and the SD/CB that are installed are not connected. Will check at Final.* | |||
| BLD - BUILDING FINAL | 09/24/2025 | Disapproved - NO FEE | HCAMACHO |
| Note: 1. Outlet in the master bath that is on the front wall vanity closest to the tub needs to be removed. NEC 406.9(C) Receptacle withing 36” radius of shower/tub 2. remove grass and dirt away from new wood frame wall and sidding. Inspector Notes from Inspection 2490 1. All the smoke detectors need to be brought up to code. Need a smoke detector in every Bedroom, and a CB/SD outside all the bedrooms. They all need to be connected. FBCR 314 & 315 *None of the bedrooms have SD and the SD/CB that are installed are not connected. Will check at Final.* | |||
| INSULATION | 07/01/2025 | APPROVED - AS NOTED | HCAMACHO |
| Note: 1. All the smoke detectors need to be brought up to code. Need a smoke detector in every Bedroom, and a CB/SD outside all the bedrooms. They all need to be connected. FBCR 314 & 315 *None of the bedrooms have SD and the SD/CB that are installed are not connected. Will check at Final.* | |||
| ALL ROUGH | 06/25/2025 | APPROVED - AS NOTED | HCAMACHO |
| Note: 1. All the smoke detectors need to be brought up to code. Need a smoke detector in every Bedroom, and a CB/SD outside all the bedrooms. They all need to be connected. FBCR 314 & 315 *None of the bedrooms have SD and the SD/CB that are installed are not connected.* *Will check at Insualtion.* | |||
| WALL SHEATHING | 06/24/2025 | APPROVED | HCAMACHO |
| LATH/BRICK/ WATER BARRIER | 06/23/2025 | APPROVED - AS NOTED | HCAMACHO |
| Note: Installed Tyvek on framed walls and installing hardie over the Tyvek. | |||
| TIE DOWN | 06/23/2025 | APPROVED | HCAMACHO |
| WALL SHEATHING | 06/20/2025 | PARTIALLY APPROVED | HCAMACHO |
| Note: 1. Wall sheathing is good on the addition with the excpetion of the front porch. Still need the strapping inspected. | |||
| MONOLITHIC SLAB | 05/23/2025 | APPROVED | HCAMACHO |
| PLUMBING 1ST ROUGH UNDERGROUND | 05/22/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: ALL WASTE LINES NOT BEING USED NEED TO BE HARD CAPED AND ALL NAIL PLATES NEED TO BE 2'; ABOVE BOTTOM PLATE, AND 2'' BELOW TOP PLATE |
Review History
| Department | Status | Date In | Date Out |
| ZON | HOLD | 04/29/2025 | 04/29/2025 |
| Note: Held By: NICOLE DIMATTINA - - NDIMATTINA@PALMCOASTGOV.COM MISSING COLOR AND MATERIAL SHEET. | |||
| MECH | COMPLETE | 04/29/2025 | 04/29/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/29/2025 | 04/29/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 04/24/2025 | 04/24/2025 |
| Note: Marked INFORMATION By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM Wrong File Name Uploaded file name was not correct - Example: Site plan=site plan (do not add anything to the file names like numbers.) | |||
| BADMIN | INFORMATION | 04/24/2025 | 04/24/2025 |
| Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM RENAME TO ENERGY CALCS.PDF | |||
| ZON | HOLD | 04/17/2025 | 04/17/2025 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM REPEAT COMMENT: Please provide note that new stucco walls will be painted to match the existing house. | |||
| MECH | HOLD | 04/17/2025 | 04/22/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition | |||
| BLD | COMPLETE | 04/03/2025 | 04/09/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 04/03/2025 | 04/07/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | HOLD | 04/03/2025 | 04/08/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide energy calcs | |||
| PLUM | COMPLETE | 04/03/2025 | 04/08/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | HOLD | 04/03/2025 | 04/04/2025 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Windows and doors facing the public right of way must have banding. Please add banding around new window in front. Please provide plans showing the proposed front and left elevations. When you show existing you must also submit proposed. Plans must also note that new stucco walls will be painted to match the existing house. If any shingles must be removed, plans must also note that the will be replaced to match the existing. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 10% | (¤19.68) | 05/05/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 05/05/2025 |
| INSPECTION - RESIDENTIAL | ¤101.75 | 05/05/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤65.00 | 05/05/2025 |
| SURCHARGE FS 533.721 | ¤2.00 | 05/05/2025 |
| SURCHARGE - FS 468.631 | ¤2.66 | 05/05/2025 |
| SITE PLAN 30 | ¤30.00 | 05/05/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤211.73 |