Permit #2025040380

Permit Details

Status: COED

CONDITIONED SPACE: 3306 sqft
GARAGE: 614 sqft
OPENED PORCH (WITH ROOF) : 237 sqft
OPENED PORCH (WITH ROOF) : 208 sqft
Total Square Footage: 4365 sqft
Subdivision: 2334 - EVOLVE PALM COAST - SANDLAKE SUBDIVISION LOT 4
Job Phone: 813-917-1689
Location Address: 12 ARMENIA CT
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/22/2025
NOC: RECORDED
Applicant name: SCOTT EVAN KEUNING
Owner: TAYLOR MORRISON OF FLORIDA INC

Address

7785 BAYMEADOWS WAY

JACKSONVILLE, FL 32258

Address

SUITE 105

JACKSONVILLE, FL 32258

Contracted Stated Job Value: ¤208,548.00
Job Description: SINGLE-FAMILY HOME
Type: CN

Contractor

TAYLOR MORRISON OF FLORIDA INC
Status Location Address State License Number Phone
ACTIVE

7785 BAY MEADOWS WAY, SUITE 105

JACKSONVILLE, FL 32256

CBC1265083 (Exp: 08/31/2026) 813-917-1689

Sub Contractors

JOSEPH H STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PKWY

SANFORD, FL 32771

CAC043953 (Exp: 08/31/2026) 877-906-1113
JOSEPH HORATIO STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PARKWAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2026) 877-906-1113
BENJAMIN MICHAEL RAY
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

6310 MABLETON PKWY

JACKSONVILLE, FL 32216

SUITE 1000

MABLETON, GA 30126

CFC1428415 (Exp: 08/31/2026) 904-861-5421 904-861-5426
CHASE RANDOLPH MASSEY
Status Location Address State License Number Phone
ACTIVE

10048 103RD ST

JACKSONVILLE, FL 32210

CCC1332486 (Exp: 08/31/2026) 904-248-1133

Inspection History

Type Request Date Result Inspector
ROW - FINAL APRON (AFTER POUR) 09/04/2025 APPROVED FSLADISH
Note: 9/4/25 AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - STORMWATER FINAL 09/04/2025 APPROVED FSLADISH
Note: 9/4/25 AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
U -UTILITY RESIDENTIAL FINAL 09/04/2025 FINAL APPROVED LFITZGERALD
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/03/2025 APPROVED FSLADISH
Note: 8/19/2025 - PREVIOUS INSPECTION NOTES 8/19/25 YOU DO NOT HAVE THE REQUIRED 6" OF FALL IN THE REAR AS REQUIRED BY FLORIDA BUILDING CODE. Drainage from the structure is to be a 6-inch (5%) Residential, Chapter 4, R401.3 "Drainage from the structure is to be a 6-inch (5%) minimum slope for the first 10 FT E.Florida Building Code, Residential, Chapter 4, R401.3" YOUR RIGHT SIDE PROPERTY LINE IS INCONSISTENT GOING FROM A 13.50 UPHILL TO A 13.70 THEN FLAT AT 13.70. POSITIVE FALL .10 EVERY 20 FT. Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 feet
ROW FIELD SURVEY /GRADING CERTIFICATION 09/03/2025 APPROVED FSLADISH
Note: 9/3/25 UPON WALKING PROPERTY DRAINAGE WILL WORK. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
BLD - BUILDING FINAL 08/27/2025 FINAL APPROVED BTAYLOR
Note: 8/22/2025 - PREVIOUS INSPECTION NOTES 8/22/25 1. Seal up all wall and ceiling penetrations in garage FBC 402.5.1.1 2. Cpvc coming out of right side of house needs to be psinted/sealed for UV ptotection 3. No disconnect installed for AH 4. No hot water FBCR P2722.2 5. Seal up holes in both AH closets FBC 402.5.1.1 6. Double oven needs a breaker lock NEC 422.31 & 110.25 7. Cooktop needs a breaker lock NEC 422.31 & 110.25 8. Please label the AC Condensors and AH units for upstairs and downstairs at the panel box NEC 408.4
BLD - BUILDING FINAL 08/22/2025 Disapproved -FEE REQUIRED MCONTRYMAN
Note: 8/22/25 1. Seal up all wall and ceiling penetrations in garage FBC 402.5.1.1 2. Cpvc coming out of right side of house needs to be psinted/sealed for UV ptotection 3. No disconnect installed for AH 4. No hot water FBCR P2722.2 5. Seal up holes in both AH closets FBC 402.5.1.1 6. Double oven needs a breaker lock NEC 422.31 & 110.25 7. Cooktop needs a breaker lock NEC 422.31 & 110.25 8. Please label the AC Condensors and AH units for upstairs and downstairs at the panel box NEC 408.4
U-CROSS CONNECTION 08/22/2025 APPROVED BWRIGHT
ROW- PROJECT STATUS 08/20/2025 APPROVED FSLADISH
Note: 8/20/25 DISCUSSED WITH BOBBY CM WHAT NEEDS TO BE DONE TO PASS FINAL SURVEY INSPECTION.
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/19/2025 Disapproved - NO FEE FSLADISH
Note: 8/19/25 YOU DO NOT HAVE THE REQUIRED 6" OF FALL IN THE REAR AS REQUIRED BY FLORIDA BUILDING CODE. Drainage from the structure is to be a 6-inch (5%) Residential, Chapter 4, R401.3 "Drainage from the structure is to be a 6-inch (5%) minimum slope for the first 10 FT E.Florida Building Code, Residential, Chapter 4, R401.3" YOUR RIGHT SIDE PROPERTY LINE IS INCONSISTENT GOING FROM A 13.50 UPHILL TO A 13.70 THEN FLAT AT 13.70. POSITIVE FALL .10 EVERY 20 FT. Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 feet
ELECTRIC - EARLY POWER 07/25/2025 APPROVED - AS NOTED BTAYLOR
Note: 7-25-25 1. Emailed FPL at 10:17. 7/24/2025 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2200 5-30-25 1. Emailed FPL at 9:41. 5/23/2025 - PREVIOUS INSPECTION NOTES 5/23/25 1. No ground wire installed 2. GFCi not hooked into panel
ELECTRIC - EARLY POWER 07/24/2025 CANCELLED BY APPLICANT BTAYLOR
Note: Inspector Notes from Inspection 2200 5-30-25 1. Emailed FPL at 9:41. 5/23/2025 - PREVIOUS INSPECTION NOTES 5/23/25 1. No ground wire installed 2. GFCi not hooked into panel
LATH/BRICK/ WATER BARRIER 07/24/2025 APPROVED BTAYLOR
ROW- PRE-APRON (PRE-POUR) 07/15/2025 APPROVED - AS NOTED FSLADISH
Note: 7/15/25 POUR AREA DRY AT TIME OF THIS INSPECTION. MAKE SURE ANY WASHED OUT OR NONCOMPACTED AREAS ARE REPAIRED BEFORE POURING IF RAINS RETURN. APPROVING AS NOTED. BUILDER REQUIRED TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. . IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK SITE FOR ANY STANDING WATER. ALSO VERIFY PIPE ELEVATION HAS NOT CHANGED. AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIEMENT ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 7/14/2025 - PREVIOUS INSPECTION NOTES ** CANCELLED ON-SITE BY BUILDER _________________________________________________________________________________________________________________________ 7/10/2025 - PREVIOUS INSPECTION NOTES 7/10/25 POUR SITE HAS WASHOUTS IS FULL OF WATER IN THE APRON AND IS TOO SOFT TO POUR AT THE TIME OF THIS INSPECTION. SEE PHOTO FOR REFERENCE.
ROW- PRE-APRON (PRE-POUR) 07/14/2025 CANCELLED BY APPLICANT EMADISON
Note: ** CANCELLED ON-SITE BY BUILDER _________________________________________________________________________________________________________________________ 7/10/2025 - PREVIOUS INSPECTION NOTES 7/10/25 POUR SITE HAS WASHOUTS IS FULL OF WATER IN THE APRON AND IS TOO SOFT TO POUR AT THE TIME OF THIS INSPECTION. SEE PHOTO FOR REFERENCE.
ROW- PRE-APRON (PRE-POUR) 07/10/2025 Disapproved -FEE REQUIRED FSLADISH
Note: 7/10/25 POUR SITE HAS WASHOUTS IS FULL OF WATER IN THE APRON AND IS TOO SOFT TO POUR AT THE TIME OF THIS INSPECTION. SEE PHOTO FOR REFERENCE.
WATER METER INSTALLATION REQUEST 06/30/2025 APPROVED CBOWERMASTER
Note: 5/1/2025 1:37:32 PM- PREVIOUS INSPECTION NOTES Meters are not allowed on model homes.
GRAVITY SEWER TEST 06/25/2025 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2060 4/30/2025 - PREVIOUS INSPECTION NOTES PLAN SHOWS INTERIORFOOTER WHERE WASTE AND WATER LINEN PASS THROUGH FOOTER. NEED HARD SLEEVE ON WASTE AND WATER LINES. FBC P-311.1 PORTABLE ON STREET FBC 3302.2 NEED DUMPSTER THIS WAS A VIRTUAL INSPECTION
SEWER TIE IN 06/25/2025 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2060 4/30/2025 - PREVIOUS INSPECTION NOTES PLAN SHOWS INTERIORFOOTER WHERE WASTE AND WATER LINEN PASS THROUGH FOOTER. NEED HARD SLEEVE ON WASTE AND WATER LINES. FBC P-311.1 PORTABLE ON STREET FBC 3302.2 NEED DUMPSTER THIS WAS A VIRTUAL INSPECTION
INSULATION 06/13/2025 APPROVED BTAYLOR
Note: Inspector Notes from Inspection 2420 6-6-25 1. No 5' head pressure. 2. Upstairs window not installed. Check at insulation.
ALL ROUGH 06/06/2025 APPROVED - AS NOTED BTAYLOR
Note: 6-6-25 1. No 5' head pressure. 2. Upstairs window not installed. Check at insulation.
ELECTRIC-TUG 05/30/2025 APPROVED - AS NOTED BTAYLOR
Note: 5-30-25 1. Emailed FPL at 9:41. 5/23/2025 - PREVIOUS INSPECTION NOTES 5/23/25 1. No ground wire installed 2. GFCi not hooked into panel
LATH/BRICK/ WATER BARRIER 05/30/2025 APPROVED BTAYLOR
ROOF VALLEY & METAL 05/27/2025 APPROVED BTAYLOR
ROOF VALLEY & METAL 05/23/2025 CANCELLED BY APPLICANT WEB
ELECTRIC-TUG 05/23/2025 Disapproved - NO FEE MCONTRYMAN
Note: 5/23/25 1. No ground wire installed 2. GFCi not hooked into panel
WALL SHEATHING 05/22/2025 APPROVED BTAYLOR
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/22/2025 APPROVED BTAYLOR
FORMBOARD SURVEY (OFFICE USE ONLY) 05/21/2025 APPROVED RRICKS
PLUMBING 1ST ROUGH UNDERGROUND 05/05/2025 APPROVED - AS NOTED MGIBSON
Note: 4/30/2025 - PREVIOUS INSPECTION NOTES PLAN SHOWS INTERIORFOOTER WHERE WASTE AND WATER LINEN PASS THROUGH FOOTER. NEED HARD SLEEVE ON WASTE AND WATER LINES. FBC P-311.1 PORTABLE ON STREET FBC 3302.2 NEED DUMPSTER
MONOLITHIC SLAB 05/05/2025 APPROVED BTAYLOR
PLUMBING 1ST ROUGH UNDERGROUND 04/30/2025 PARTIALLY APPROVED MGIBSON
Note: PLAN SHOWS INTERIORFOOTER WHERE WASTE AND WATER LINEN PASS THROUGH FOOTER. NEED HARD SLEEVE ON WASTE AND WATER LINES. FBC P-311.1 PORTABLE ON STREET FBC 3302.2 NEED DUMPSTER
WATER METER INSTALLATION REQUEST 04/30/2025 Disapproved - NO FEE CBOWERMASTER
Note: Utilities have not been accepted

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 08/20/2025 08/21/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
SW1 COMPLETE 08/20/2025 08/27/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 08/20/2025 08/20/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 05/21/2025 05/21/2025
Note: Released By: RODNEY RICKS - (386)986-2001 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 05/21/2025 05/21/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
MECH COMPLETE 04/22/2025 04/22/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 04/22/2025 04/22/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
URB COMPLETE 04/08/2025 04/14/2025
Note: Released By: MATTHEW SIERRA - (386)286-2002 - MSIERRA@PALMCOASTGOV.COM
BADMIN COMPLETE 04/07/2025 04/11/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 04/07/2025 04/14/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide nosing detail and size of nosing projection of stairs. R311.7.5.3
CUSVC COMPLETE 04/07/2025 04/08/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM Water/Sewer Impact fees will be added at a later date after all utility agreements are final. Please not, a meter will not be installed until all agreements are final.
ELEC COMPLETE 04/07/2025 04/10/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/07/2025 04/08/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 04/07/2025 04/09/2025
LOCATE COMPLETE 04/07/2025 04/11/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH HOLD 04/07/2025 04/10/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2023 8Th Edition
SW1 COMPLETE 04/07/2025 04/14/2025
Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM Please take note of "New Subdivsion Construction Entrance attachment".
ZON COMPLETE 04/07/2025 04/08/2025
Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 09/03/2025
SW ENG REINSPECTION 30 ¤30.00 08/20/2025
SEWER CAPITAL FACILITY ¤3,613.92 06/26/2025
WATER CAPITAL FACILITY FEE ¤3,039.48 06/26/2025
WATER PERMIT INSPECTION ¤40.00 06/26/2025
WATER-METER ¤965.03 06/26/2025
WATER- TURN ON ¤50.00 06/26/2025
WATER- TURN ON ¤50.00 06/26/2025
WATER METER W/OUT TAP ¤965.03 06/26/2025
SURCHARGE FS 533.721 ¤20.06 04/22/2025
SURCHARGE - FS 468.631 ¤30.09 04/22/2025
SW ENG - FOUNDATION SURVEY ¤20.00 04/22/2025
SW ENG INSPECTION 80 ¤80.00 04/22/2025
SW ENG PRE APRON ¤30.00 04/22/2025
ADJUSTMENT 10% (¤222.92) 04/22/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/22/2025
INSPECTION - RESIDENTIAL ¤1,713.25 04/22/2025
PLAN REVIEW - RESIDENTIAL ¤485.94 04/22/2025
FC IMPACT FEE EMS ¤62.00 04/22/2025
IMPACT FEE FIRE ¤434.51 04/22/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 04/22/2025
FC IMPACT FEE LIBRARY ¤268.00 04/22/2025
IMPACT FEE PARKS ¤1,828.01 04/22/2025
IMPACT FEE SCHOOL ¤5,450.00 04/22/2025
IMPACT FEE TRANSPORTATION ¤3,502.00 04/22/2025
WATER PERMIT REVIEW ¤25.00 04/22/2025
SITE PLAN 30 ¤30.00 04/22/2025
SW ENG - REVIEW 20 ¤20.00 04/22/2025
SW ENG RES REVIEW 200 ¤200.00 04/22/2025
WASTEWATER PERM INSPECTION ¤80.00 04/22/2025
WASTEWATER PERM REVIEW ¤25.00 04/22/2025
Fees Total Due: ¤0.00 Total Paid: ¤23,122.40