I want to search for...

Permit #2025040712

Permit Details

Status: COED

Parcel Id: 07-11-31-7032-00230-0200
CONDITIONED SPACE: 1809 sqft
GARAGE: 406 sqft
OPENED PORCH (WITH ROOF) : 33 sqft
Total Square Footage: 2248 sqft
Block: 00230
Subdivision: -
Job Phone: 239-571-5325
Location Address: 38 ROYAL OAK DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 05/27/2025
NOC: RECORDED
Applicant name: RYAN SCOTT DAVIS
Owner: SYNERGY HOMES LLC

Address

581 NW MERCANTILE PL

PORT SAINT LUCIE, FL 34986

Address

SUITE 106

PORT SAINT LUCIE, FL 34986

Lot: 0200
Contracted Stated Job Value: ¤200,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

SYNERGY HOMES, LLC
Status Location Address State License Number
ACTIVE

1 HARGROVE GRADE, SUITE B1

PALM COAST, FL 32137

CBC1254289 (Exp: 08/31/2026)

Sub Contractors

TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733
HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
MICHAEL FRANK MORELLO
Status Location Address State License Number Phone Fax
ACTIVE

2 HARGROVE GRADE

PALM COAST, FL 32164

CAC1819466 (Exp: 08/31/2026) 386-445-5023 386-446-4614

Inspection History

Type Request Date Result Inspector
ROW - STORMWATER FINAL 11/17/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 11/13/2025 - PREVIOUS INSPECTION NOTES RECIEVED TEXT ASKING TO CANCEL INSPECTION
ROW - STORMWATER FINAL 11/13/2025 CANCELLED BY APPLICANT TPOLACEK
Note: RECIEVED TEXT ASKING TO CANCEL INSPECTION
U -UTILITY RESIDENTIAL FINAL 11/12/2025 FINAL APPROVED BHAINES
Note: Inspector Notes from Inspection 9035 no irr-no cc
ROW - FINAL APRON (AFTER POUR) 11/12/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
BLD - BUILDING FINAL 11/12/2025 APPROVED CVANSTRAHLEN
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/10/2025 APPROVED TPOLACEK
ROW FIELD SURVEY /GRADING CERTIFICATION 11/10/2025 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ELECTRIC - EARLY POWER 10/06/2025 APPROVED CVANSTRAHLEN
GRAVITY SEWER TEST 09/25/2025 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
SEWER TIE IN 09/25/2025 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
ROW- PRE-APRON (PRE-POUR) 09/19/2025 APPROVED - AS NOTED TPOLACEK
Note: 09-19-25 TPOLACEK*** BUILDER MUST REPLACE FORM BOARD ON RIGHT SIDE AND REESTABLISH FOOTERS BEFORE POURING CONCRETE. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/17/2025 - PREVIOUS INSPECTION NOTES 09-17-25 TPOLACEK*** POUR AREA TOO SOFT TO APPROVE STILL 9/16/2025 - PREVIOUS INSPECTION NOTES 09-16-25 TPOLACEK*** POUR AREA TOO SOFT AND MUDDY & HOLDING WATER.SEE PHOTOS
ROW- PRE-APRON (PRE-POUR) 09/17/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 09-17-25 TPOLACEK*** POUR AREA TOO SOFT TO APPROVE STILL 9/16/2025 - PREVIOUS INSPECTION NOTES 09-16-25 TPOLACEK*** POUR AREA TOO SOFT AND MUDDY & HOLDING WATER.SEE PHOTOS
ELECTRIC - EARLY POWER 09/17/2025 CANCELLED BY APPLICANT WEB
ELECTRIC - EARLY POWER 09/17/2025 CANCELLED BY APPLICANT WEB
ROW- PRE-APRON (PRE-POUR) 09/16/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 09-16-25 TPOLACEK*** POUR AREA TOO SOFT AND MUDDY & HOLDING WATER.SEE PHOTOS
INSULATION 09/09/2025 APPROVED CVANSTRAHLEN
LATH/BRICK/ WATER BARRIER 09/08/2025 APPROVED CVANSTRAHLEN
ALL ROUGH 09/04/2025 APPROVED CVANSTRAHLEN
ROOF VALLEY & METAL 08/29/2025 APPROVED CVANSTRAHLEN
Note:
ROOF VALLEY & METAL 08/27/2025 CANCELLED BY APPLICANT CVANSTRAHLEN
Note: cancelled by text 8/26/2025 - PREVIOUS INSPECTION NOTES Cancelled by text 8/25/2025 - PREVIOUS INSPECTION NOTES Please fix previous item from previous inspection 8/22/2025 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1- systhetic underlayment for new construction roofing by DBPR double layer is requiered under dreap edge all around roof deck
ROOF VALLEY & METAL 08/26/2025 CANCELLED BY APPLICANT CVANSTRAHLEN
Note: Cancelled by text 8/25/2025 - PREVIOUS INSPECTION NOTES Please fix previous item from previous inspection 8/22/2025 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1- systhetic underlayment for new construction roofing by DBPR double layer is requiered under dreap edge all around roof deck
ROOF VALLEY & METAL 08/25/2025 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Please fix previous item from previous inspection 8/22/2025 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1- systhetic underlayment for new construction roofing by DBPR double layer is requiered under dreap edge all around roof deck
WALL SHEATHING 08/22/2025 CANCELLED BY INSPECTOR CVANSTRAHLEN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/22/2025 APPROVED CVANSTRAHLEN
ROOF VALLEY & METAL 08/22/2025 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Please fix items before next inspection #1- systhetic underlayment for new construction roofing by DBPR double layer is requiered under dreap edge all around roof deck
TIE BEAM / LINTEL 08/14/2025 APPROVED CVANSTRAHLEN
Note:
TIE BEAM / LINTEL 08/13/2025 Disapproved -FEE REQUIRED MKRASKI
Note: 1. Not ready for inspection, masons still onsite laying block. Please cancel inspection if the job is not ready for inspection
U-CROSS CONNECTION 08/12/2025 APPROVED - AS NOTED LFITZGERALD
Note: no irr-no cc
MONOLITHIC SLAB 08/07/2025 APPROVED CVANSTRAHLEN
PLUMBING 1ST ROUGH UNDERGROUND 08/05/2025 APPROVED MGIBSON
FORMBOARD SURVEY (OFFICE USE ONLY) 07/30/2025 APPROVED RRICKS
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 07/17/2025 APPROVED JMUNSON
WATER METER INSTALLATION REQUEST 07/01/2025 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 07/30/2025 07/30/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 07/30/2025 07/30/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 07/17/2025 07/17/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SW1 COMPLETE 05/21/2025 05/22/2025
Note: Released By: RODNEY RICKS - (386)986-2001 - RRICKS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 05/21/2025 05/22/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ZON COMPLETE 05/21/2025 05/21/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SW1 HOLD 05/08/2025 05/14/2025
Note: Held By: RODNEY RICKS - (386)986-2001 - RRICKS@PALMCOASTGOV.COM FFE of proposed lot is more than 10" below lot 19. Please revise site plan to meet COPC standards.
ENGIN1 COMPLETE 05/08/2025 05/08/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ZON COMPLETE 05/08/2025 05/08/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SW1 HOLD 04/23/2025 04/23/2025
Note: Held By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM COPC survey crew noticed FFE on lot 19 is misrepresented on the site plan. Please submit a revised site plan.
BADMIN COMPLETE 04/14/2025 04/16/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 04/14/2025 04/16/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 04/14/2025 04/23/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 04/14/2025 04/17/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/14/2025 04/14/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 04/14/2025 04/15/2025
LOCATE COMPLETE 04/14/2025 04/15/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 04/14/2025 04/15/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 04/14/2025 04/22/2025
Note: Held By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM There is too much water impacting lots in the back of the yard. Move berm/break point closer to the easement in the back yard so less water is impacting lots. Possibly raise FFE to decrease the slope of property swale.
ZON COMPLETE 04/14/2025 04/14/2025
Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM
SWALE COMPLETE 04/14/2025 04/29/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 11/13/2025
REINSPECTION RESIDENTIAL ¤40.00 11/13/2025
REINSPECTION RESIDENTIAL ¤40.00 11/13/2025
SW ENG REINSPECTION 30 ¤30.00 11/13/2025
SW ENG REINSPECTION 30 ¤30.00 11/13/2025
SW ENG - REVIEW 20 ¤20.00 05/27/2025
SW ENG RES REVIEW 200 ¤200.00 05/27/2025
WATER METER W/ TAP ¤2,326.93 05/27/2025
SEWER CREDIT (¤2,465.75) 05/27/2025
WASTEWATER PERM INSPECTION ¤80.00 05/27/2025
WASTEWATER PERM REVIEW ¤25.00 05/27/2025
SEWER CAPITAL FACILITY ¤3,930.70 05/27/2025
WATER CAPITAL FACILITY FEE ¤3,496.74 05/27/2025
WATER PERMIT REVIEW ¤25.00 05/27/2025
WATER MAIN EXTENSION IMPACT ¤854.40 05/27/2025
SITE PLAN 30 ¤30.00 05/27/2025
WATER- TURN ON ¤50.00 05/27/2025
ADJUSTMENT 10% (¤120.20) 05/27/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 05/27/2025
INSPECTION - RESIDENTIAL ¤913.00 05/27/2025
PLAN REVIEW - RESIDENTIAL ¤258.96 05/27/2025
FC IMPACT FEE EMS ¤62.00 05/27/2025
IMPACT FEE FIRE ¤434.51 05/27/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 05/27/2025
FC IMPACT FEE LIBRARY ¤268.00 05/27/2025
IMPACT FEE PARKS ¤1,828.01 05/27/2025
IMPACT FEE SCHOOL ¤5,450.00 05/27/2025
IMPACT FEE TRANSPORTATION ¤1,916.00 05/27/2025
WASTEWATER MAIN EXTENSION IMPA ¤2,189.82 05/27/2025
SURCHARGE FS 533.721 ¤10.82 05/27/2025
SURCHARGE - FS 468.631 ¤16.23 05/27/2025
SW ENG - FOUNDATION SURVEY ¤20.00 05/27/2025
SW ENG INSPECTION 80 ¤80.00 05/27/2025
SW ENG PRE APRON ¤30.00 05/27/2025
Fees Total Due: ¤0.00 Total Paid: ¤22,358.17