I want to search for...
Permit #2025040767
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7081-00030-0010 |
| CONDITIONED SPACE: 910 sqft |
| Total Square Footage: 910 sqft |
| Block: 00030 |
| Subdivision: - |
| Job Phone: 386-931-1917 |
| Location Address: 1 BLEAU CT |
| Type: DBA - DETACHED BUILDING ADDITION |
| Issue Date: 07/10/2025 |
| NOC: RECORDED |
| Applicant name: BRAD MICHAEL THOMAS |
| Owner: GUTIERREZ LOUIS & CARMEN H&W & JANEEN GUTIERREZ JT |
|
Address 1 BLEAU COURT PALM COAST, FL 32164 |
| Lot: 0010 |
| Contracted Stated Job Value: ¤276,000.00 |
| Job Description: BUILDING ADDITION |
| Type: CN |
Contractor
THOMAS CONSULTING AND CONSTRUCTION LLC
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
25 PINE DRIVE PALM COAST, FL 32164 |
STE 3C PALM COAST, FL 32164 |
CGC1506292 (Exp: 08/31/2026) | 386-585-4424 |
Sub Contractors
KYLE RODBOURN
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1325 W HWY 100 BUNNELL, FL 32110 |
CAC1821358 (Exp: 08/31/2026) | 386-586-9039 |
YORDANIS GONZALEZ
| Status | Location Address | State License Number | Phone |
| ACTIVE |
33 RICKENBACKER DRIVE PALM COAST, FL 32164 |
CCC1328730 (Exp: 08/31/2026) | 386-804-4109 |
GIOVANNI DISARRO
| Status | Location Address | State License Number |
| INACTIVE |
107 BURROUGHS DRIVE PALM COAST, FL 32137 |
CFC1430761 (Exp: 08/31/2026) |
ARIEL LEONARDO HERNANDEZ PEREZ
| Status | Location Address | State License Number | Phone |
| ACTIVE |
20 PRAIRIE LANE PALM COAST, FL 32164 |
EC13013098 (Exp: 08/31/2026) | 561-335-4905 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 01/16/2026 | FINAL APPROVED | HCAMACHO |
| Note: 1/15/2026 - PREVIOUS INSPECTION NOTES 1/15/26 1. Seal up wall and ceiling penetrations in AH closet FBC 402.5.1.1 2. Sink stopper not working in guest bath 3. Window in 3rd bedroom (facing pool) has top muntin that needs to be glued back in place | |||
| BLD - BUILDING FINAL | 01/15/2026 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 1/15/26 1. Seal up wall and ceiling penetrations in AH closet FBC 402.5.1.1 2. Sink stopper not working in guest bath 3. Window in 3rd bedroom (facing pool) has top muntin that needs to be glued back in place | |||
| U -UTILITY RESIDENTIAL FINAL | 12/30/2025 | FINAL APPROVED | BWRIGHT |
| ELECTRIC FINAL | 12/30/2025 | APPROVED - AS NOTED | RMARTIN |
| Note: Check AHU breaker size, it is not labled on the unit. Make sure it is labled on Building Final to make sure MOCP is correct in the panel. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 12/29/2025 | APPROVED | RRICKS |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - FINAL INSPECTION | 12/26/2025 | APPROVED | GBERTOLA |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/26/2025 | APPROVED | GBERTOLA |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ALL ROUGH | 11/17/2025 | APPROVED | KSANDOE |
| Note: Pre-assembled modular building | |||
| WALL SHEATHING | 11/17/2025 | APPROVED | KSANDOE |
| Note: Pre-assembled modular building | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/17/2025 | APPROVED | KSANDOE |
| Note: Modular building | |||
| ROOF VALLEY & METAL | 11/17/2025 | APPROVED | KSANDOE |
| Note: Pre-assembled modular building | |||
| INSULATION | 11/17/2025 | APPROVED | KSANDOE |
| PLUMBING 1ST ROUGH UNDERGROUND | 11/06/2025 | APPROVED - AS NOTED | HCAMACHO |
| Note: 1. Water test done with 5' head and shower pan tested also. | |||
| SEWER TIE IN | 11/06/2025 | APPROVED | HCAMACHO |
| ELECTRIC - EARLY POWER | 10/17/2025 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 10/17/25 Email sent to FPL 10/16/2025 - PREVIOUS INSPECTION NOTES 10/16/25 1. Schedule 80 pipe not installed for underground service. Arrived at 855am and again at 225pm (electrician told me he would try to have it done by noon) | |||
| ELECTRIC - EARLY POWER | 10/16/2025 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 10/16/25 1. Schedule 80 pipe not installed for underground service. Arrived at 855am and again at 225pm (electrician told me he would try to have it done by noon) | |||
| LATH/BRICK/ WATER BARRIER | 10/16/2025 | APPROVED | MCONTRYMAN |
| Note: Pre-Assembled Modular Home | |||
| COLUMN POST/BEAM/TIE DOWN CONNECTOR | 10/16/2025 | APPROVED | MCONTRYMAN |
| Note: *** NOTES ADDED BY MCONTRYMAN 10/16/2025 9:37:46 AM *** Pre-Assembled Modular Home | |||
| ELECTRIC UNDERGROUND | 10/10/2025 | APPROVED | HCAMACHO |
| TIE BEAM / LINTEL | 09/04/2025 | APPROVED | KSANDOE |
| TIE BEAM / LINTEL | 08/05/2025 | APPROVED - AS NOTED | BTAYLOR |
| Note: 8-5-25 1. Stem wall rebar was inspected at this inspection. | |||
| FOOTER | 07/25/2025 | APPROVED | MCONTRYMAN |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 11/05/2025 | 11/13/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/03/2025 | 09/03/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 07/07/2025 | 07/10/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 06/30/2025 | 07/02/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Stair riser height should not be more than 7 3/4" as per R311.7.5.1. Please revise on plan sheet S-02. | |||
| ZON | HOLD | 06/04/2025 | 06/04/2025 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please turn in original affidavit to us for recording | |||
| MECH | COMPLETE | 06/04/2025 | 06/06/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 06/04/2025 | 06/09/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. ok 2. ok 3. ok 4. ok 5. ok 6. ok 7. ok 8. ok 9. ok 10. ok 11. Provide landing details for front and back doors. R311.7.6 Provide stair landing construction and floor sheathing details. Provide stair landing attachment details necessary to achieve minimum design loads. 12. ok 13. ok 14. ok | |||
| ELEC | COMPLETE | 06/04/2025 | 06/04/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 06/04/2025 | 06/04/2025 |
| Note: Released By: EDWARD MADISON - (386)986-4770 - EMADISON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 06/04/2025 | 06/04/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | HOLD | 04/14/2025 | 04/17/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Front porch and rear door. 1. Provide lumber species and grade for deck joists, beams, stair stringers and band board. R502.1.1, R301.5, Table R301.5, R507.5, R 507.6 2. Provide design loads for guards and guards in-fill components. R301.5, Table R301.5. 3. Provide rise and run for stairs. R311.7.5.1, R311.7.5.2. 4. Provide tread material specs and concentrated load for treads per Table R301.5 Note c. 5. Provide handrail detail and type (Type I or Type II) and mounting height and attachment detail. R311.7.8 through R311.7.8.3 and R311.7.8.5. 6. Provide stair stringer attachment details at upper and lower ends. R311.5. 7. Provide stair tread nosing detail. R311.7.5.3. 8. Provide height of guard from deck surface to top rail exclusive of post height. R312.1.2. 9. Provide opening limitations between bottom of guard and deck surface; between in-fill components in guard and between bottom of guard and space between stair treads and risers. R312.1.3. 10. Provide fastening details for posts to deck, guard top and bottom rails to post and guard in-fill components to guard top and bottom rails. R301.5, Table R301.5. 11. Provide landing details for front and back doors. R311.7.6 Provide stair landing construction and floor sheathing details. Provide stair landing attachment details necessary to achieve minimum design loads. 12. Provide riser height R311.7.5.1. 13. Provide tread depth R311.7.5.2. 14. Provide stair live and dead loads per R301.4, R301.5 and Table R301.5. | |||
| ELEC | HOLD | 04/14/2025 | 04/21/2025 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit electrical load calcs and prove the existing service can accommodate the new addition. | |||
| ENGIN1 | CANCEL | 04/14/2025 | 04/17/2025 |
| GAS | CANCEL | 04/14/2025 | 04/16/2025 |
| MECH | HOLD | 04/14/2025 | 04/17/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide return air out of bedrooms on duct layout 2. Energy Calcs and State Card need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition 3. State card not required for addition | |||
| PLUM | COMPLETE | 04/14/2025 | 04/17/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 04/14/2025 | 04/16/2025 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 04/14/2025 | 04/15/2025 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please provide a single family dwelling affidavit signed by all owners on deed. Once electronic copy is approved we will ask for original. Remove Accessory Dwelling Unit verbiage from all plans. This is a detached building addition. Please provide a landscape plan showing required foundation plantings. Site plan must show the stairs, material and width. Show setback from stairs at the back to property line on site plan. Stairs/walkway cannot exceed 6ft in width. Please show AC pad on site plan. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤20.00 | 01/14/2026 |
| PLAN REVIEW - REVISION | ¤32.50 | 10/16/2025 |
| RECORDING FEE REIMBURSE DOC | ¤10.00 | 07/10/2025 |
| SURCHARGE FS 533.721 | ¤9.04 | 07/10/2025 |
| SURCHARGE - FS 468.631 | ¤13.56 | 07/10/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 07/10/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 07/10/2025 |
| SITE PLAN 30 | ¤30.00 | 07/10/2025 |
| ADJUSTMENT 10% | (¤100.43) | 07/10/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 07/10/2025 |
| INSPECTION - RESIDENTIAL | ¤759.00 | 07/10/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤215.28 | 07/10/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤1,058.95 |