Permit #2025040856

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7016-00100-0180
Block: 00100
Subdivision: -
Job Phone: 386-627-1357
Location Address: 29 COLORADO DR
Type: DR - DRIVEWAY
Issue Date: 06/10/2025
NOC: RECORDED
Applicant name: MITCHELL REED
Owner: MOREA MICHAEL & NANCY H&W

Address

29 COLORADO DRIVE

PALM COAST, FL 32137

Lot: 0180
Contracted Stated Job Value: ¤15,000.00
Job Description: Paver Driveway
Type: CN

Contractor

ROYAL PAVING LLC
Status Location Address Phone
ACTIVE

4 LEWISTON COURT

PALM COAST, FL 32137

386-237-7516

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 04/09/2026 APPROVED TLOWE
ROW - FINAL APRON (AFTER POUR) 10/30/2025 APPROVED - AS NOTED PFLANAGAN
Note: CULVERT PIPE PITCHED THE WRONG DIRECTION PASSING AS NOTED THAT CULVERT IS .09 PITCH THE WRONG WAY AND THERE IS NO STANDING WATER FROM SUNDAYS BIG RAIN EVENT. ---------------------------------------------------------------------------------- 9/4/2025 - PREVIOUS INSPECTION NOTES ** 09/04/25 RIGHT SIDE CULVERT IS BACK PITCHED .10 WHICH IS OUT OF TOLERANCE AS STORMWATER IS TO FLOW FROM LEFT TO RIGHT __________________________________________________________________________________________________________________I nspector Notes from Inspection 9270 TALKED TO OMITCH THEY NEED TO POUR A FOOTER ALONG SIDWALK GOING TO THE HOUSE TO THE GARAGE. WILL CHECK AT FINAL ------------------------------------------------------------------------------- 6/12/2025 - PREVIOUS INSPECTION NOTES RIGHT CULVERT IS .02 OUT OF THE TOLERANCE PASSING AS NOTED THAT IT WILL WORK WITH THE RUN TO THE CATCH BASIN AROUND THE CORNER. YOU NEED TO LEVEL BASE MORE AND COMPACT IT MORE ALSO NO PAVERS AT THIS TIME. READY TO APRON AND PAVER RESTRAINTS ONLY. BEFORE NEXT PRE POUR ALL PAVER BASE NEEDS TO SPREAD AND COMPACTED TO CITY'S STANDARDS WITH NO PAVERS LAID AT THE TIME OF THE INSPECTION. IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS.
ROW - FINAL INSPECTION 10/30/2025 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection.
ROW - FINAL APRON (AFTER POUR) 09/04/2025 Disapproved -FEE REQUIRED EMADISON
Note: ** 09/04/25 RIGHT SIDE CULVERT IS BACK PITCHED .10 WHICH IS OUT OF TOLERANCE AS STORMWATER IS TO FLOW FROM LEFT TO RIGHT __________________________________________________________________________________________________________________I nspector Notes from Inspection 9270 TALKED TO OMITCH THEY NEED TO POUR A FOOTER ALONG SIDWALK GOING TO THE HOUSE TO THE GARAGE. WILL CHECK AT FINAL ------------------------------------------------------------------------------- 6/12/2025 - PREVIOUS INSPECTION NOTES RIGHT CULVERT IS .02 OUT OF THE TOLERANCE PASSING AS NOTED THAT IT WILL WORK WITH THE RUN TO THE CATCH BASIN AROUND THE CORNER. YOU NEED TO LEVEL BASE MORE AND COMPACT IT MORE ALSO NO PAVERS AT THIS TIME. READY TO APRON AND PAVER RESTRAINTS ONLY. BEFORE NEXT PRE POUR ALL PAVER BASE NEEDS TO SPREAD AND COMPACTED TO CITY'S STANDARDS WITH NO PAVERS LAID AT THE TIME OF THE INSPECTION. IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS.
ROW- PRE-APRON (PRE-POUR) 06/17/2025 APPROVED - AS NOTED PFLANAGAN
Note: TALKED TO OMITCH THEY NEED TO POUR A FOOTER ALONG SIDWALK GOING TO THE HOUSE TO THE GARAGE. WILL CHECK AT FINAL ------------------------------------------------------------------------------- 6/12/2025 - PREVIOUS INSPECTION NOTES RIGHT CULVERT IS .02 OUT OF THE TOLERANCE PASSING AS NOTED THAT IT WILL WORK WITH THE RUN TO THE CATCH BASIN AROUND THE CORNER. YOU NEED TO LEVEL BASE MORE AND COMPACT IT MORE ALSO NO PAVERS AT THIS TIME. READY TO APRON AND PAVER RESTRAINTS ONLY. BEFORE NEXT PRE POUR ALL PAVER BASE NEEDS TO SPREAD AND COMPACTED TO CITY'S STANDARDS WITH NO PAVERS LAID AT THE TIME OF THE INSPECTION. IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS.
ROW- PAVER RESTRAINTS 06/12/2025 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection.
ROW- PRE-APRON (PRE-POUR) 06/12/2025 PARTIALLY APPROVED PFLANAGAN
Note: RIGHT CULVERT IS .02 OUT OF THE TOLERANCE PASSING AS NOTED THAT IT WILL WORK WITH THE RUN TO THE CATCH BASIN AROUND THE CORNER. YOU NEED TO LEVEL BASE MORE AND COMPACT IT MORE ALSO NO PAVERS AT THIS TIME. READY TO APRON AND PAVER RESTRAINTS ONLY. BEFORE NEXT PRE POUR ALL PAVER BASE NEEDS TO SPREAD AND COMPACTED TO CITY'S STANDARDS WITH NO PAVERS LAID AT THE TIME OF THE INSPECTION. IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS.

Review History

Department Status Date In Date Out
ZON COMPLETE 06/02/2025 06/02/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ZON HOLD 04/21/2025 04/21/2025
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please turn in original right of way agreement for recording
ENGIN1 COMPLETE 04/16/2025 04/16/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
UTL COMPLETE 04/16/2025 04/21/2025
Note: Released By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM
ZON HOLD 04/16/2025 04/16/2025
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Please provide Right-of-Way Utilization Agreement for staff review.
SWALE COMPLETE 04/16/2025 04/22/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
SW ENG REINSPECTION 20 ¤20.00 04/08/2026
SW ENG RES REVIEW 200 ¤200.00 06/10/2025
SITE PLAN 15 ¤15.00 06/10/2025
ADJUSTMENT 10% (¤3.00) 06/10/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 06/10/2025
RECORDING FEE REIMBURSE DOC ¤44.00 06/10/2025
SW ENG INSPECTION 40 ¤40.00 06/10/2025
SW ENG PRE APRON ¤30.00 06/10/2025
Fees Total Due: ¤0.00 Total Paid: ¤376.00