I want to search for...
Permit #2025040856
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7016-00100-0180 |
| Block: 00100 |
| Subdivision: - |
| Job Phone: 386-627-1357 |
| Location Address: 29 COLORADO DR |
| Type: DR - DRIVEWAY |
| Issue Date: 06/10/2025 |
| NOC: RECORDED |
| Applicant name: MITCHELL REED |
| Owner: MOREA MICHAEL & NANCY H&W |
|
Address 29 COLORADO DRIVE PALM COAST, FL 32137 |
| Lot: 0180 |
| Contracted Stated Job Value: ¤15,000.00 |
| Job Description: Paver Driveway |
| Type: CN |
Contractor
ROYAL PAVING LLC
| Status | Location Address | Phone |
| ACTIVE |
4 LEWISTON COURT PALM COAST, FL 32137 |
386-237-7516 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 04/09/2026 | APPROVED | TLOWE |
| ROW - FINAL APRON (AFTER POUR) | 10/30/2025 | APPROVED - AS NOTED | PFLANAGAN |
| Note: CULVERT PIPE PITCHED THE WRONG DIRECTION PASSING AS NOTED THAT CULVERT IS .09 PITCH THE WRONG WAY AND THERE IS NO STANDING WATER FROM SUNDAYS BIG RAIN EVENT. ---------------------------------------------------------------------------------- 9/4/2025 - PREVIOUS INSPECTION NOTES ** 09/04/25 RIGHT SIDE CULVERT IS BACK PITCHED .10 WHICH IS OUT OF TOLERANCE AS STORMWATER IS TO FLOW FROM LEFT TO RIGHT __________________________________________________________________________________________________________________I nspector Notes from Inspection 9270 TALKED TO OMITCH THEY NEED TO POUR A FOOTER ALONG SIDWALK GOING TO THE HOUSE TO THE GARAGE. WILL CHECK AT FINAL ------------------------------------------------------------------------------- 6/12/2025 - PREVIOUS INSPECTION NOTES RIGHT CULVERT IS .02 OUT OF THE TOLERANCE PASSING AS NOTED THAT IT WILL WORK WITH THE RUN TO THE CATCH BASIN AROUND THE CORNER. YOU NEED TO LEVEL BASE MORE AND COMPACT IT MORE ALSO NO PAVERS AT THIS TIME. READY TO APRON AND PAVER RESTRAINTS ONLY. BEFORE NEXT PRE POUR ALL PAVER BASE NEEDS TO SPREAD AND COMPACTED TO CITY'S STANDARDS WITH NO PAVERS LAID AT THE TIME OF THE INSPECTION. IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. | |||
| ROW - FINAL INSPECTION | 10/30/2025 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. | |||
| ROW - FINAL APRON (AFTER POUR) | 09/04/2025 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 09/04/25 RIGHT SIDE CULVERT IS BACK PITCHED .10 WHICH IS OUT OF TOLERANCE AS STORMWATER IS TO FLOW FROM LEFT TO RIGHT __________________________________________________________________________________________________________________I nspector Notes from Inspection 9270 TALKED TO OMITCH THEY NEED TO POUR A FOOTER ALONG SIDWALK GOING TO THE HOUSE TO THE GARAGE. WILL CHECK AT FINAL ------------------------------------------------------------------------------- 6/12/2025 - PREVIOUS INSPECTION NOTES RIGHT CULVERT IS .02 OUT OF THE TOLERANCE PASSING AS NOTED THAT IT WILL WORK WITH THE RUN TO THE CATCH BASIN AROUND THE CORNER. YOU NEED TO LEVEL BASE MORE AND COMPACT IT MORE ALSO NO PAVERS AT THIS TIME. READY TO APRON AND PAVER RESTRAINTS ONLY. BEFORE NEXT PRE POUR ALL PAVER BASE NEEDS TO SPREAD AND COMPACTED TO CITY'S STANDARDS WITH NO PAVERS LAID AT THE TIME OF THE INSPECTION. IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. | |||
| ROW- PRE-APRON (PRE-POUR) | 06/17/2025 | APPROVED - AS NOTED | PFLANAGAN |
| Note: TALKED TO OMITCH THEY NEED TO POUR A FOOTER ALONG SIDWALK GOING TO THE HOUSE TO THE GARAGE. WILL CHECK AT FINAL ------------------------------------------------------------------------------- 6/12/2025 - PREVIOUS INSPECTION NOTES RIGHT CULVERT IS .02 OUT OF THE TOLERANCE PASSING AS NOTED THAT IT WILL WORK WITH THE RUN TO THE CATCH BASIN AROUND THE CORNER. YOU NEED TO LEVEL BASE MORE AND COMPACT IT MORE ALSO NO PAVERS AT THIS TIME. READY TO APRON AND PAVER RESTRAINTS ONLY. BEFORE NEXT PRE POUR ALL PAVER BASE NEEDS TO SPREAD AND COMPACTED TO CITY'S STANDARDS WITH NO PAVERS LAID AT THE TIME OF THE INSPECTION. IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. | |||
| ROW- PAVER RESTRAINTS | 06/12/2025 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. | |||
| ROW- PRE-APRON (PRE-POUR) | 06/12/2025 | PARTIALLY APPROVED | PFLANAGAN |
| Note: RIGHT CULVERT IS .02 OUT OF THE TOLERANCE PASSING AS NOTED THAT IT WILL WORK WITH THE RUN TO THE CATCH BASIN AROUND THE CORNER. YOU NEED TO LEVEL BASE MORE AND COMPACT IT MORE ALSO NO PAVERS AT THIS TIME. READY TO APRON AND PAVER RESTRAINTS ONLY. BEFORE NEXT PRE POUR ALL PAVER BASE NEEDS TO SPREAD AND COMPACTED TO CITY'S STANDARDS WITH NO PAVERS LAID AT THE TIME OF THE INSPECTION. IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 06/02/2025 | 06/02/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ZON | HOLD | 04/21/2025 | 04/21/2025 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please turn in original right of way agreement for recording | |||
| ENGIN1 | COMPLETE | 04/16/2025 | 04/16/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| UTL | COMPLETE | 04/16/2025 | 04/21/2025 |
| Note: Released By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM | |||
| ZON | HOLD | 04/16/2025 | 04/16/2025 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Please provide Right-of-Way Utilization Agreement for staff review. | |||
| SWALE | COMPLETE | 04/16/2025 | 04/22/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| SW ENG REINSPECTION 20 | ¤20.00 | 04/08/2026 |
| SW ENG RES REVIEW 200 | ¤200.00 | 06/10/2025 |
| SITE PLAN 15 | ¤15.00 | 06/10/2025 |
| ADJUSTMENT 10% | (¤3.00) | 06/10/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 06/10/2025 |
| RECORDING FEE REIMBURSE DOC | ¤44.00 | 06/10/2025 |
| SW ENG INSPECTION 40 | ¤40.00 | 06/10/2025 |
| SW ENG PRE APRON | ¤30.00 | 06/10/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤376.00 |