I want to search for...
Permit #2025040954
Permit Details
Status: COED
| Parcel Id: 07-11-31-7035-01300-0050 |
| CONDITIONED SPACE: 1809 sqft |
| GARAGE: 406 sqft |
| OPENED PORCH (WITH ROOF) : 33 sqft |
| Total Square Footage: 2248 sqft |
| Block: 01300 |
| Subdivision: - |
| Job Phone: 239-571-5325 |
| Location Address: 8 BIRD TREE PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 07/10/2025 |
| NOC: RECORDED |
| Applicant name: RYAN SCOTT DAVIS |
| Owner: SYNERGY HOMES LLC |
|
Address 581 NW MERCANTILE PLACE PORT SAINT LUCIE, FL 34986 |
|
Address 106 PORT SAINT LUCIE, FL 34986 |
| Lot: 0050 |
| Contracted Stated Job Value: ¤200,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
SYNERGY HOMES, LLC
| Status | Location Address | State License Number |
| ACTIVE |
1 HARGROVE GRADE, SUITE B1 PALM COAST, FL 32137 |
CBC1254289 (Exp: 08/31/2026) |
Sub Contractors
TERRY BRICE DICKERSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4300 ST JOHN'S PARKWAY ALPHARETTA, GA 30009 |
CCC1326209 (Exp: 08/31/2026) | 407-548-6733 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
MICHAEL FRANK MORELLO
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2 HARGROVE GRADE PALM COAST, FL 32164 |
CAC1819466 (Exp: 08/31/2026) | 386-445-5023 | 386-446-4614 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 01/26/2026 | FINAL APPROVED | JSTEWART |
| Note: 1/23/2026 - PREVIOUS INSPECTION NOTES 1. Please seal tub spout to wall. FBCR P2705.1 2. Spare Bath left lav Flow of Hot water is reversed. FBCR P2722.2 / FPBC 607.4 ( hot water to the Left/ Mixing valve as indicated on fixture). | |||
| BLD - BUILDING FINAL | 01/23/2026 | Disapproved - NO FEE | JSTEWART |
| Note: 1. Please seal tub spout to wall. FBCR P2705.1 2. Spare Bath left lav Flow of Hot water is reversed. FBCR P2722.2 / FPBC 607.4 ( hot water to the Left/ Mixing valve as indicated on fixture). | |||
| ROW - STORMWATER FINAL | 01/23/2026 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 12/17/2025 - PREVIOUS INSPECTION NOTES 12-17-25 TPOLACEK*** COMMNETS NOT ADDRESSED PLEASE READ PREVIOUS COMMENTS 12/15/2025 - PREVIOUS INSPECTION NOTES 12-15-25 TPOLACEK*** BUILDER NEEDS TO SOD ALL BARE DISTURBED GROUND IN VACANT LOT TO THE LEFT. THERE IS SOME TRASH IN THE VACANT ALONG PROPERTY LINE AS WELL | |||
| ROW - STORMWATER FINAL | 12/17/2025 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 12-17-25 TPOLACEK*** COMMNETS NOT ADDRESSED PLEASE READ PREVIOUS COMMENTS 12/15/2025 - PREVIOUS INSPECTION NOTES 12-15-25 TPOLACEK*** BUILDER NEEDS TO SOD ALL BARE DISTURBED GROUND IN VACANT LOT TO THE LEFT. THERE IS SOME TRASH IN THE VACANT ALONG PROPERTY LINE AS WELL | |||
| U -UTILITY RESIDENTIAL FINAL | 12/15/2025 | FINAL APPROVED | BWRIGHT |
| Note: Inspector Notes from Inspection 9035 No IRR, No CC | |||
| ROW - FINAL APRON (AFTER POUR) | 12/15/2025 | APPROVED | TPOLACEK |
| Note: PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE, AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - STORMWATER FINAL | 12/15/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 12-15-25 TPOLACEK*** BUILDER NEEDS TO SOD ALL BARE DISTURBED GROUND IN VACANT LOT TO THE LEFT. THERE IS SOME TRASH IN THE VACANT ALONG PROPERTY LINE AS WELL | |||
| ELECTRIC - EARLY POWER | 11/19/2025 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 11/19/25 Email sent to FPL | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 11/14/2025 | APPROVED | EMADISON |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 11/14/2025 | APPROVED | EMADISON |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| GRAVITY SEWER TEST | 11/05/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| SEWER TIE IN | 11/05/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| ROW- PRE-APRON (PRE-POUR) | 10/31/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. | |||
| PEP TANK INSTALLATION REQUEST | 10/16/2025 | APPROVED | CBOWERMASTER |
| INSULATION | 10/07/2025 | APPROVED | FWILLIS |
| Note: 10/6/2025 - PREVIOUS INSPECTION NOTES 10/6/25 - CANCELLED AS REQUESTED. PLEASE DISREGARD EARLIER INSPECTION AND NOTES. 10/6/2025 - PREVIOUS INSPECTION NOTES 10/6/25 - ON SITE 10:15A NO INSULATION INSTALLED, NO FIRE CAULKING. WORKERS ON SITE JUST STARTING. 10/3/2025 - PREVIOUS INSPECTION NOTES 10/3/25 1. No insulation is installed. Please only schedule inspections when the site is ready | |||
| INSULATION | 10/06/2025 | Disapproved -FEE REQUIRED | FWILLIS |
| Note: 10/6/25 - ON SITE 10:15A NO INSULATION INSTALLED, NO FIRE CAULKING. WORKERS ON SITE JUST STARTING. 10/3/2025 - PREVIOUS INSPECTION NOTES 10/3/25 1. No insulation is installed. Please only schedule inspections when the site is ready | |||
| INSULATION | 10/06/2025 | CANCELLED BY APPLICANT | FWILLIS |
| Note: 10/6/25 - CANCELLED AS REQUESTED. PLEASE DISREGARD EARLIER INSPECTION AND NOTES. 10/6/2025 - PREVIOUS INSPECTION NOTES 10/6/25 - ON SITE 10:15A NO INSULATION INSTALLED, NO FIRE CAULKING. WORKERS ON SITE JUST STARTING. 10/3/2025 - PREVIOUS INSPECTION NOTES 10/3/25 1. No insulation is installed. Please only schedule inspections when the site is ready | |||
| INSULATION | 10/03/2025 | Disapproved -FEE REQUIRED | MCONTRYMAN |
| Note: 10/3/25 1. No insulation is installed. Please only schedule inspections when the site is ready | |||
| ALL ROUGH | 10/01/2025 | APPROVED | MCONTRYMAN |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/30/2025 | APPROVED | JSTEWART |
| Note: 9/19/2025 - PREVIOUS INSPECTION NOTES Interior Non bearing walls are framed at 24" OC, approved plans call for 16" OC. Please frame walls to plan, or submit a revision for 24" OC. Per page 9.0DTL (Detail #8). 9/16/2025 - PREVIOUS INSPECTION NOTES MULTIPLE TRADES WORKING THROUGHOUT, ELECTRICIANS, PLUMBERS, WINDOW INSTALLERS. MULTIPLE TRIP HAZARDS ON THE FLOOR TOOLS AND PRODUCTS. SAFETY 101.3 REASONABLE REQUIREMENT FOR SAFETY. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/19/2025 | Disapproved - NO FEE | JSTEWART |
| Note: Interior Non bearing walls are framed at 24" OC, approved plans call for 16" OC. Please frame walls to plan, or submit a revision for 24" OC. Per page 9.0DTL (Detail #8). 9/16/2025 - PREVIOUS INSPECTION NOTES MULTIPLE TRADES WORKING THROUGHOUT, ELECTRICIANS, PLUMBERS, WINDOW INSTALLERS. MULTIPLE TRIP HAZARDS ON THE FLOOR TOOLS AND PRODUCTS. SAFETY 101.3 REASONABLE REQUIREMENT FOR SAFETY. | |||
| LATH/BRICK/ WATER BARRIER | 09/19/2025 | APPROVED | JSTEWART |
| WALL SHEATHING | 09/16/2025 | APPROVED | FWILLIS |
| Note: Exterior Gables | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/16/2025 | Disapproved - NO FEE | FWILLIS |
| Note: MULTIPLE TRADES WORKING THROUGHOUT, ELECTRICIANS, PLUMBERS, WINDOW INSTALLERS. MULTIPLE TRIP HAZARDS ON THE FLOOR TOOLS AND PRODUCTS. SAFETY 101.3 REASONABLE REQUIREMENT FOR SAFETY. | |||
| ROOF VALLEY & METAL | 09/16/2025 | APPROVED | FWILLIS |
| TIE BEAM / LINTEL | 09/04/2025 | APPROVED | JSTEWART |
| U-CROSS CONNECTION | 09/04/2025 | APPROVED - AS NOTED | BWRIGHT |
| Note: No IRR, No CC | |||
| FORMBOARD SURVEY (OFFICE USE ONLY) | 08/28/2025 | APPROVED | PFLANAGAN |
| MONOLITHIC SLAB | 08/28/2025 | APPROVED | FWILLIS |
| Note: 8/27/2025 - PREVIOUS INSPECTION NOTES MISSING UFER GROUND .NEC..250.52(3) | |||
| MONOLITHIC SLAB | 08/27/2025 | Disapproved -FEE REQUIRED | FWILLIS |
| Note: MISSING UFER GROUND .NEC..250.52(3) | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 08/25/2025 | APPROVED | MGIBSON |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 08/18/2025 | APPROVED | PKNAPIK |
| WATER METER INSTALLATION REQUEST | 08/01/2025 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 09/25/2025 | 09/26/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 08/26/2025 | 08/28/2025 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/26/2025 | 08/26/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 08/18/2025 | 08/18/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 07/10/2025 | 07/10/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 07/10/2025 | 07/10/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/10/2025 | 07/10/2025 |
| Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 05/14/2025 | 05/19/2025 |
| Note: Released By: RODNEY RICKS - (386)986-2001 - RRICKS@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 05/14/2025 | 05/14/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/14/2025 | 05/14/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM No zoning changes only stormwater | |||
| SW1 | HOLD | 05/02/2025 | 05/07/2025 |
| Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO HAVE EXISTING ELEVATIONS ON ALL ADJACENT LOTS AND THEY CAN NOT BE ESTIMATED 10' INSIDE THE LOTS. | |||
| ENGIN1 | COMPLETE | 05/02/2025 | 05/02/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/02/2025 | 05/02/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 04/17/2025 | 04/24/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/17/2025 | 04/24/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 04/17/2025 | 04/24/2025 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 04/17/2025 | 04/21/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 04/17/2025 | 04/17/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 04/17/2025 | 04/22/2025 |
| LOCATE | COMPLETE | 04/17/2025 | 04/23/2025 |
| Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 04/17/2025 | 04/23/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 04/17/2025 | 04/25/2025 |
| Note: Held By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM Common swales are preferred when applicable. Please revise site plan with common swale between this lot and lot 4 which is vacant. Note: Lot 3 FFE is 25.97' so there will be no issues with lot 4 in the future when lot 4 is improved if the FFE for this lot is increased. | |||
| ZON | COMPLETE | 04/17/2025 | 04/18/2025 |
| Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 04/17/2025 | 04/25/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| RSI REINSPECTION 1 | ¤35.00 | 01/23/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 01/23/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 01/23/2026 |
| FC IMPACT FEE EMS | ¤62.00 | 07/10/2025 |
| IMPACT FEE FIRE | ¤434.51 | 07/10/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 07/10/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 07/10/2025 |
| IMPACT FEE PARKS | ¤1,828.01 | 07/10/2025 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 07/10/2025 |
| IMPACT FEE TRANSPORTATION | ¤1,916.00 | 07/10/2025 |
| PEP TANK INSTALL | ¤756.74 | 07/10/2025 |
| WATER- TURN ON | ¤50.00 | 07/10/2025 |
| ADJUSTMENT 10% | (¤120.20) | 07/10/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 07/10/2025 |
| INSPECTION - RESIDENTIAL | ¤913.00 | 07/10/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤258.96 | 07/10/2025 |
| WASTEWATER MAIN EXTENSION IMPA | ¤2,189.82 | 07/10/2025 |
| SURCHARGE FS 533.721 | ¤10.82 | 07/10/2025 |
| SURCHARGE - FS 468.631 | ¤16.23 | 07/10/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 07/10/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 07/10/2025 |
| SW ENG PRE APRON | ¤30.00 | 07/10/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 07/10/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 07/10/2025 |
| WATER METER W/ TAP | ¤2,326.93 | 07/10/2025 |
| SEWER CREDIT | (¤1,466.00) | 07/10/2025 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 07/10/2025 |
| WASTEWATER PERM REVIEW | ¤25.00 | 07/10/2025 |
| SEWER CAPITAL FACILITY | ¤3,930.70 | 07/10/2025 |
| WATER CAPITAL FACILITY FEE | ¤3,496.74 | 07/10/2025 |
| WATER PERMIT REVIEW | ¤25.00 | 07/10/2025 |
| WATER MAIN EXTENSION IMPACT | ¤854.40 | 07/10/2025 |
| SITE PLAN 30 | ¤30.00 | 07/10/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤24,049.66 |