I want to search for...

Permit #2025040954

Permit Details

Status: COED

Parcel Id: 07-11-31-7035-01300-0050
CONDITIONED SPACE: 1809 sqft
GARAGE: 406 sqft
OPENED PORCH (WITH ROOF) : 33 sqft
Total Square Footage: 2248 sqft
Block: 01300
Subdivision: -
Job Phone: 239-571-5325
Location Address: 8 BIRD TREE PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 07/10/2025
NOC: RECORDED
Applicant name: RYAN SCOTT DAVIS
Owner: SYNERGY HOMES LLC

Address

581 NW MERCANTILE PLACE

PORT SAINT LUCIE, FL 34986

Address

106

PORT SAINT LUCIE, FL 34986

Lot: 0050
Contracted Stated Job Value: ¤200,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

SYNERGY HOMES, LLC
Status Location Address State License Number
ACTIVE

1 HARGROVE GRADE, SUITE B1

PALM COAST, FL 32137

CBC1254289 (Exp: 08/31/2026)

Sub Contractors

TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733
HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
MICHAEL FRANK MORELLO
Status Location Address State License Number Phone Fax
ACTIVE

2 HARGROVE GRADE

PALM COAST, FL 32164

CAC1819466 (Exp: 08/31/2026) 386-445-5023 386-446-4614

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 01/26/2026 FINAL APPROVED JSTEWART
Note: 1/23/2026 - PREVIOUS INSPECTION NOTES 1. Please seal tub spout to wall. FBCR P2705.1 2. Spare Bath left lav Flow of Hot water is reversed. FBCR P2722.2 / FPBC 607.4 ( hot water to the Left/ Mixing valve as indicated on fixture).
BLD - BUILDING FINAL 01/23/2026 Disapproved - NO FEE JSTEWART
Note: 1. Please seal tub spout to wall. FBCR P2705.1 2. Spare Bath left lav Flow of Hot water is reversed. FBCR P2722.2 / FPBC 607.4 ( hot water to the Left/ Mixing valve as indicated on fixture).
ROW - STORMWATER FINAL 01/23/2026 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 12/17/2025 - PREVIOUS INSPECTION NOTES 12-17-25 TPOLACEK*** COMMNETS NOT ADDRESSED PLEASE READ PREVIOUS COMMENTS 12/15/2025 - PREVIOUS INSPECTION NOTES 12-15-25 TPOLACEK*** BUILDER NEEDS TO SOD ALL BARE DISTURBED GROUND IN VACANT LOT TO THE LEFT. THERE IS SOME TRASH IN THE VACANT ALONG PROPERTY LINE AS WELL
ROW - STORMWATER FINAL 12/17/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 12-17-25 TPOLACEK*** COMMNETS NOT ADDRESSED PLEASE READ PREVIOUS COMMENTS 12/15/2025 - PREVIOUS INSPECTION NOTES 12-15-25 TPOLACEK*** BUILDER NEEDS TO SOD ALL BARE DISTURBED GROUND IN VACANT LOT TO THE LEFT. THERE IS SOME TRASH IN THE VACANT ALONG PROPERTY LINE AS WELL
U -UTILITY RESIDENTIAL FINAL 12/15/2025 FINAL APPROVED BWRIGHT
Note: Inspector Notes from Inspection 9035 No IRR, No CC
ROW - FINAL APRON (AFTER POUR) 12/15/2025 APPROVED TPOLACEK
Note: PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE, AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - STORMWATER FINAL 12/15/2025 Disapproved - NO FEE TPOLACEK
Note: 12-15-25 TPOLACEK*** BUILDER NEEDS TO SOD ALL BARE DISTURBED GROUND IN VACANT LOT TO THE LEFT. THERE IS SOME TRASH IN THE VACANT ALONG PROPERTY LINE AS WELL
ELECTRIC - EARLY POWER 11/19/2025 APPROVED - AS NOTED MCONTRYMAN
Note: 11/19/25 Email sent to FPL
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/14/2025 APPROVED EMADISON
ROW FIELD SURVEY /GRADING CERTIFICATION 11/14/2025 APPROVED EMADISON
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
GRAVITY SEWER TEST 11/05/2025 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
SEWER TIE IN 11/05/2025 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
ROW- PRE-APRON (PRE-POUR) 10/31/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR.
PEP TANK INSTALLATION REQUEST 10/16/2025 APPROVED CBOWERMASTER
INSULATION 10/07/2025 APPROVED FWILLIS
Note: 10/6/2025 - PREVIOUS INSPECTION NOTES 10/6/25 - CANCELLED AS REQUESTED. PLEASE DISREGARD EARLIER INSPECTION AND NOTES. 10/6/2025 - PREVIOUS INSPECTION NOTES 10/6/25 - ON SITE 10:15A NO INSULATION INSTALLED, NO FIRE CAULKING. WORKERS ON SITE JUST STARTING. 10/3/2025 - PREVIOUS INSPECTION NOTES 10/3/25 1. No insulation is installed. Please only schedule inspections when the site is ready
INSULATION 10/06/2025 Disapproved -FEE REQUIRED FWILLIS
Note: 10/6/25 - ON SITE 10:15A NO INSULATION INSTALLED, NO FIRE CAULKING. WORKERS ON SITE JUST STARTING. 10/3/2025 - PREVIOUS INSPECTION NOTES 10/3/25 1. No insulation is installed. Please only schedule inspections when the site is ready
INSULATION 10/06/2025 CANCELLED BY APPLICANT FWILLIS
Note: 10/6/25 - CANCELLED AS REQUESTED. PLEASE DISREGARD EARLIER INSPECTION AND NOTES. 10/6/2025 - PREVIOUS INSPECTION NOTES 10/6/25 - ON SITE 10:15A NO INSULATION INSTALLED, NO FIRE CAULKING. WORKERS ON SITE JUST STARTING. 10/3/2025 - PREVIOUS INSPECTION NOTES 10/3/25 1. No insulation is installed. Please only schedule inspections when the site is ready
INSULATION 10/03/2025 Disapproved -FEE REQUIRED MCONTRYMAN
Note: 10/3/25 1. No insulation is installed. Please only schedule inspections when the site is ready
ALL ROUGH 10/01/2025 APPROVED MCONTRYMAN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/30/2025 APPROVED JSTEWART
Note: 9/19/2025 - PREVIOUS INSPECTION NOTES Interior Non bearing walls are framed at 24" OC, approved plans call for 16" OC. Please frame walls to plan, or submit a revision for 24" OC. Per page 9.0DTL (Detail #8). 9/16/2025 - PREVIOUS INSPECTION NOTES MULTIPLE TRADES WORKING THROUGHOUT, ELECTRICIANS, PLUMBERS, WINDOW INSTALLERS. MULTIPLE TRIP HAZARDS ON THE FLOOR TOOLS AND PRODUCTS. SAFETY 101.3 REASONABLE REQUIREMENT FOR SAFETY.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/19/2025 Disapproved - NO FEE JSTEWART
Note: Interior Non bearing walls are framed at 24" OC, approved plans call for 16" OC. Please frame walls to plan, or submit a revision for 24" OC. Per page 9.0DTL (Detail #8). 9/16/2025 - PREVIOUS INSPECTION NOTES MULTIPLE TRADES WORKING THROUGHOUT, ELECTRICIANS, PLUMBERS, WINDOW INSTALLERS. MULTIPLE TRIP HAZARDS ON THE FLOOR TOOLS AND PRODUCTS. SAFETY 101.3 REASONABLE REQUIREMENT FOR SAFETY.
LATH/BRICK/ WATER BARRIER 09/19/2025 APPROVED JSTEWART
WALL SHEATHING 09/16/2025 APPROVED FWILLIS
Note: Exterior Gables
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/16/2025 Disapproved - NO FEE FWILLIS
Note: MULTIPLE TRADES WORKING THROUGHOUT, ELECTRICIANS, PLUMBERS, WINDOW INSTALLERS. MULTIPLE TRIP HAZARDS ON THE FLOOR TOOLS AND PRODUCTS. SAFETY 101.3 REASONABLE REQUIREMENT FOR SAFETY.
ROOF VALLEY & METAL 09/16/2025 APPROVED FWILLIS
TIE BEAM / LINTEL 09/04/2025 APPROVED JSTEWART
U-CROSS CONNECTION 09/04/2025 APPROVED - AS NOTED BWRIGHT
Note: No IRR, No CC
FORMBOARD SURVEY (OFFICE USE ONLY) 08/28/2025 APPROVED PFLANAGAN
MONOLITHIC SLAB 08/28/2025 APPROVED FWILLIS
Note: 8/27/2025 - PREVIOUS INSPECTION NOTES MISSING UFER GROUND .NEC..250.52(3)
MONOLITHIC SLAB 08/27/2025 Disapproved -FEE REQUIRED FWILLIS
Note: MISSING UFER GROUND .NEC..250.52(3)
PLUMBING 1ST ROUGH UNDERGROUND 08/25/2025 APPROVED MGIBSON
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 08/18/2025 APPROVED PKNAPIK
WATER METER INSTALLATION REQUEST 08/01/2025 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
BLD COMPLETE 09/25/2025 09/26/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SW1 COMPLETE 08/26/2025 08/28/2025
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 08/26/2025 08/26/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 08/18/2025 08/18/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 07/10/2025 07/10/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 07/10/2025 07/10/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 07/10/2025 07/10/2025
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
SW1 COMPLETE 05/14/2025 05/19/2025
Note: Released By: RODNEY RICKS - (386)986-2001 - RRICKS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 05/14/2025 05/14/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ZON COMPLETE 05/14/2025 05/14/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM No zoning changes only stormwater
SW1 HOLD 05/02/2025 05/07/2025
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO HAVE EXISTING ELEVATIONS ON ALL ADJACENT LOTS AND THEY CAN NOT BE ESTIMATED 10' INSIDE THE LOTS.
ENGIN1 COMPLETE 05/02/2025 05/02/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ZON COMPLETE 05/02/2025 05/02/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BADMIN COMPLETE 04/17/2025 04/24/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 04/17/2025 04/24/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 04/17/2025 04/24/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 04/17/2025 04/21/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/17/2025 04/17/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 04/17/2025 04/22/2025
LOCATE COMPLETE 04/17/2025 04/23/2025
Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM
MECH COMPLETE 04/17/2025 04/23/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 04/17/2025 04/25/2025
Note: Held By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM Common swales are preferred when applicable. Please revise site plan with common swale between this lot and lot 4 which is vacant. Note: Lot 3 FFE is 25.97' so there will be no issues with lot 4 in the future when lot 4 is improved if the FFE for this lot is increased.
ZON COMPLETE 04/17/2025 04/18/2025
Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM
SWALE COMPLETE 04/17/2025 04/25/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
RSI REINSPECTION 1 ¤35.00 01/23/2026
REINSPECTION RESIDENTIAL ¤40.00 01/23/2026
REINSPECTION RESIDENTIAL ¤40.00 01/23/2026
FC IMPACT FEE EMS ¤62.00 07/10/2025
IMPACT FEE FIRE ¤434.51 07/10/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 07/10/2025
FC IMPACT FEE LIBRARY ¤268.00 07/10/2025
IMPACT FEE PARKS ¤1,828.01 07/10/2025
IMPACT FEE SCHOOL ¤5,450.00 07/10/2025
IMPACT FEE TRANSPORTATION ¤1,916.00 07/10/2025
PEP TANK INSTALL ¤756.74 07/10/2025
WATER- TURN ON ¤50.00 07/10/2025
ADJUSTMENT 10% (¤120.20) 07/10/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 07/10/2025
INSPECTION - RESIDENTIAL ¤913.00 07/10/2025
PLAN REVIEW - RESIDENTIAL ¤258.96 07/10/2025
WASTEWATER MAIN EXTENSION IMPA ¤2,189.82 07/10/2025
SURCHARGE FS 533.721 ¤10.82 07/10/2025
SURCHARGE - FS 468.631 ¤16.23 07/10/2025
SW ENG - FOUNDATION SURVEY ¤20.00 07/10/2025
SW ENG INSPECTION 80 ¤80.00 07/10/2025
SW ENG PRE APRON ¤30.00 07/10/2025
SW ENG - REVIEW 20 ¤20.00 07/10/2025
SW ENG RES REVIEW 200 ¤200.00 07/10/2025
WATER METER W/ TAP ¤2,326.93 07/10/2025
SEWER CREDIT (¤1,466.00) 07/10/2025
WASTEWATER PERM INSPECTION ¤80.00 07/10/2025
WASTEWATER PERM REVIEW ¤25.00 07/10/2025
SEWER CAPITAL FACILITY ¤3,930.70 07/10/2025
WATER CAPITAL FACILITY FEE ¤3,496.74 07/10/2025
WATER PERMIT REVIEW ¤25.00 07/10/2025
WATER MAIN EXTENSION IMPACT ¤854.40 07/10/2025
SITE PLAN 30 ¤30.00 07/10/2025
Fees Total Due: ¤0.00 Total Paid: ¤24,049.66