Permit #2025041059

Permit Details

Status: COED

Parcel Id: 07-11-31-7030-00550-0370
CONDITIONED SPACE: 1908 sqft
GARAGE: 651 sqft
OPENED PORCH (WITH ROOF) : 182 sqft
OPENED PORCH (WITH ROOF) : 68 sqft
Total Square Footage: 2809 sqft
Block: 00550
Subdivision: -
Job Phone: 407-476-8195
Location Address: 2 RANSHIRE LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 10/24/2025
NOC: RECORDED
Applicant name: CARLETTE RENE WITTE
Owner: INB BFS LLC

Address

3670 MAGUIRE BOULEVARD

ORLANDO, FL 32803

Address

SUITE 220

ORLANDO, FL 32803

Lot: 0370
Contracted Stated Job Value: ¤175,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

INNOVATIVE NATIONWIDE BUILDERS INC
Status Location Address State License Number Phone
ACTIVE

3670 MAGUIRE BLVD #220

,

CRC1330026 (Exp: 08/31/2026) 855-694-6634

Sub Contractors

TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733
ANTHONY OKEITH FENNELL
Status Location Address State License Number Phone
ACTIVE

217 N. WESTMONTE DR, SUITE 1007

ALTAMONTE SPRINGS, FL 32714

EC13011194 (Exp: 08/31/2026) 407-404-4000
HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
JASON LEE JAMES
Status Location Address State License Number Phone
ACTIVE

217 N WESTMONTE DR SUITE 1007

ALTAMONTE SPRINGS, FL 32714

CAC1820196 (Exp: 08/31/2026) 407-404-4000

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 06/09/2026 FINAL APPROVED MCONTRYMAN
Note: 6/3/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-NEC 331.30- SECURING & SUPPORTING ( tug outlet ) #2-Missing PEP tank breaker #3-M1502.4.7 Exhaust duct required. Where space for a clothes dryer is provided, an exhaust duct system shall be installed. Where the clothes dryer is not installed at the time of occupancy the exhaust duct shall be capped or plugged in the space in which it originates and identified and marked “future use. #4-Slidding door do not lock on one off the sides #5-car garage motor not connected to power for small garage door ( can't test ) #6-FBC-R . 302.6 seal all garage penetration ( holes ), wall and ceiling #7-Missing attic light #8-Missing insulation certificated
U -UTILITY RESIDENTIAL FINAL 06/09/2026 APPROVED - AS NOTED TLOWE
Note: 6/5/2026 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 9035 No CC, No IRR pep tank stone broken Pep not working
ROW - STORMWATER FINAL 06/05/2026 APPROVED FSLADISH
Note: 6/5/26 CULVERT CLEAR AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ________________________________________________________________________________________________________________________________ 5/29/2026 - PREVIOUS INSPECTION NOTES CULVERT MUST BE CLEAN OF SEDIMENT APPROVING AFTER POUR AND HOLDING STORMWATER FINAL
U -UTILITY RESIDENTIAL FINAL 06/05/2026 Disapproved - NO FEE TLOWE
Note: Inspector Notes from Inspection 9035 No CC, No IRR Pep not working
BLD - BUILDING FINAL 06/03/2026 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: *** NOTES ADDED BY CVANSTRAHLEN 6/3/2026 2:28:46 PM *** #9- NEC 331.30-SECURING & SUPPORTING ( Conduit for ground wire under miter box ) Please fix items before next inspection #1-NEC 331.30- SECURING & SUPPORTING ( tug outlet ) #2-Missing PEP tank breaker #3-M1502.4.7 Exhaust duct required. Where space for a clothes dryer is provided, an exhaust duct system shall be installed. Where the clothes dryer is not installed at the time of occupancy the exhaust duct shall be capped or plugged in the space in which it originates and identified and marked “future use. #4-Slidding door do not lock on one off the sides #5-car garage motor not connected to power for small garage door ( can't test ) #6-FBC-R . 302.6 seal all garage penetration ( holes ), wall and ceiling #7-Missing attic light #8-Missing insulation certificated
U-CROSS CONNECTION 05/29/2026 APPROVED - AS NOTED BHAINES
Note: No CC, No IRR
ROW - FINAL APRON (AFTER POUR) 05/29/2026 APPROVED - AS NOTED TPOLACEK
Note: CULVERT MUST BE CLEAN OF SEDIMENT APPROVING AFTER POUR AND HOLDING STORMWATER FINAL
ROW - STORMWATER FINAL 05/29/2026 Disapproved - NO FEE TPOLACEK
Note: CULVERT MUST BE CLEAN OF SEDIMENT APPROVING AFTER POUR AND HOLDING STORMWATER FINAL
U -UTILITY RESIDENTIAL FINAL 05/26/2026 Disapproved - NO FEE BHAINES
Note: No power to pep tank
ROW - STORMWATER FINAL 05/26/2026 CANCELLED BY APPLICANT WEB
ROW - FINAL APRON (AFTER POUR) 05/26/2026 CANCELLED BY APPLICANT WEB
ROW- FINAL SURVEY/GRADING CERTIFICATION 05/20/2026 APPROVED FSLADISH
Note: 5/20/26 BASED ON THE ENGINEER SIGNED AND SEALED LGADC MEETING THE COPC MINIMUM REQUIREMENTS AT THE TIME OF THIS INSPECTION, I AM APPROVING THIS DOCUMENT. Effective 3/25/26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certification for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types.
ROW FIELD SURVEY /GRADING CERTIFICATION 05/20/2026 CANCELLED BY INSPECTOR FSLADISH
Note: 5/20/26 Effective 3/25/26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certification for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types.
ROW- PRE-APRON (PRE-POUR) 04/17/2026 APPROVED FSLADISH
Note: 4/17/26 PIPE INVERT IS GOOD AT TIME OF THIS INSPECTION. BUILDER REFER TO CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED. DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR BEFORE POURING. . IF FIBERGLASS OPTION IS USED, BUILDER REQUIRED TO USE 3000 PSI CONCRETE AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN, BUILDER SHOULD DOUBLE CHECK SITE FOR ANY STANDING WATER AND VERIFY PIPE ELEVATION HAS NOT CHANGED. NO EXPANSION JOINTS ALLOWED, AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR.
ELECTRIC - EARLY POWER 04/10/2026 APPROVED HCAMACHO
GRAVITY SEWER TEST 04/09/2026 APPROVED CVANSTRAHLEN
SEWER TIE IN 04/09/2026 APPROVED CVANSTRAHLEN
INSULATION 03/16/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/16/2026 4:25:14 PM *** Approved 3/12/2026 - PREVIOUS INSPECTION NOTES Items from previous inspection not been resolved #1-E-cals missing ducts lay-out Item #2 is not fix #3- dryer ven metal duct seams need to be seal per manufacture espec Inspector Notes from Inspection 2420 Please fix items before next inspection #1-Missing E-cals #2-NEC-200.6 (B)-Side 4 AWG or large an isulated grounded conductor shall be identified ( electrical main panel) 3/3/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-Plumbing not completed FBC [A]107.4-NOT READY - WORK INCOMPLETE required a full inspectio
INSULATION 03/12/2026 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Items from previous inspection not been resolved #1-E-cals missing ducts lay-out Item #2 is not fix #3- dryer ven metal duct seams need to be seal per manufacture espec Inspector Notes from Inspection 2420 Please fix items before next inspection #1-Missing E-cals #2-NEC-200.6 (B)-Side 4 AWG or large an isulated grounded conductor shall be identified ( electrical main panel) 3/3/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-Plumbing not completed FBC [A]107.4-NOT READY - WORK INCOMPLETE required a full inspectio
PEP TANK INSTALLATION REQUEST 03/09/2026 APPROVED ISANDERSON
ALL ROUGH 03/05/2026 APPROVED - AS NOTED CVANSTRAHLEN
Note: Please fix items before next inspection #1-Missing E-cals #2-NEC-200.6 (B)-Side 4 AWG or large an isulated grounded conductor shall be identified ( electrical main panel) 3/3/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-Plumbing not completed FBC [A]107.4-NOT READY - WORK INCOMPLETE required a full inspectio
ELECTRIC-TUG 03/03/2026 APPROVED CVANSTRAHLEN
Note: 2/27/2026 - PREVIOUS INSPECTION NOTES 2-27-26 1. Breakers are not labeled. 2. Protective pipe is SCH40 and it needs to be SCH80.
ALL ROUGH 03/03/2026 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Please fix items before next inspection #1-Plumbing not completed FBC [A]107.4-NOT READY - WORK INCOMPLETE required a full inspectio
ELECTRIC-TUG 02/27/2026 Disapproved - NO FEE BTAYLOR
Note: 2-27-26 1. Breakers are not labeled. 2. Protective pipe is SCH40 and it needs to be SCH80.
LATH/BRICK/ WATER BARRIER 02/27/2026 APPROVED BTAYLOR
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/20/2026 APPROVED CVANSTRAHLEN
ROOF VALLEY & METAL 02/20/2026 APPROVED CVANSTRAHLEN
ROOF SHEATHING 02/17/2026 APPROVED CVANSTRAHLEN
WALL SHEATHING 02/17/2026 APPROVED CVANSTRAHLEN
FORMBOARD SURVEY (OFFICE USE ONLY) 02/13/2026 APPROVED AMOBLEY
ROW - DRAINAGE 02/13/2026 APPROVED PFLANAGAN
Note: CORRECTION MADE -------------------------------------------------------------------------- 12/4/2025 - PREVIOUS INSPECTION NOTES 12-4-25 TPOLACEK*** BUILDER NEEDS TO REMOVE PORTA POTTY FROM SWALE, SILT FENCE ACROSS LEFT SIDE LEAVING 20' CONSTRUCTION ENTRANCE AS SHOWN IN RESIDENTIAL CONSTRUCTION DIAGRAM ATTACHED AS PHOTO. 12/1/2025 - PREVIOUS INSPECTION NOTES 12-1-25 TPOLACEK*** SITE STILL HAS NO SILT FENCE AS REQUIRED. 3 DAYS TO COMPLY. 11/24/2025 - PREVIOUS INSPECTION NOTES TPOLACEK*** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 5 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day.
ROW - EROSION CONTROL / INLET PROTE/SILT FENCE 02/11/2026 CANCELLED BY INSPECTOR JMYERS
Note: 2/12/26 BUILDER CALLED, SCHEDULED WRONG INSPECTION INTENDED FOR ROW-DRAINAGE INSPECTION.
TIE BEAM / LINTEL 02/03/2026 APPROVED CVANSTRAHLEN
Note: 1/30/2026 - PREVIOUS INSPECTION NOTES 1/30/26: 1). Dowel / down rods do not meet the minimum clearance (2" from face of block and/or 3/4: from inside of block) as required. (FBC-R606.3.4) Spray painted orange. 3 locations at the front entry.
TIE BEAM / LINTEL 01/30/2026 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 1/30/2026 1:07:14 PM *** 1/30/26: 1). Dowel / down rods do not meet the minimum clearance (2" from face of block and/or 3/4: from inside of block) as required. (FBC-R606.3.4) Spray painted orange. 3 locations at the front entry.
MONOLITHIC SLAB 01/22/2026 APPROVED CVANSTRAHLEN
PLUMBING 1ST ROUGH UNDERGROUND 01/15/2026 APPROVED CVANSTRAHLEN
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 01/14/2026 APPROVED PKNAPIK
ROW - DRAINAGE 12/04/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 12-4-25 TPOLACEK*** BUILDER NEEDS TO REMOVE PORTA POTTY FROM SWALE, SILT FENCE ACROSS LEFT SIDE LEAVING 20' CONSTRUCTION ENTRANCE AS SHOWN IN RESIDENTIAL CONSTRUCTION DIAGRAM ATTACHED AS PHOTO. 12/1/2025 - PREVIOUS INSPECTION NOTES 12-1-25 TPOLACEK*** SITE STILL HAS NO SILT FENCE AS REQUIRED. 3 DAYS TO COMPLY. 11/24/2025 - PREVIOUS INSPECTION NOTES TPOLACEK*** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 5 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day.
ROW - DRAINAGE 11/30/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 12-1-25 TPOLACEK*** SITE STILL HAS NO SILT FENCE AS REQUIRED. 3 DAYS TO COMPLY. 11/24/2025 - PREVIOUS INSPECTION NOTES TPOLACEK*** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 5 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day.
WATER METER INSTALLATION REQUEST 11/25/2025 APPROVED BVITALE
ROW - DRAINAGE 11/24/2025 Disapproved - NO FEE TPOLACEK
Note: TPOLACEK*** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 5 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day.

Review History

Department Status Date In Date Out
MECH COMPLETE 02/20/2026 02/23/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH COMPLETE 02/11/2026 02/13/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 01/12/2026 01/14/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD HOLD 01/09/2026 01/12/2026
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Please provide Final building pad certification letter. 2ND REQUEST
SW1 COMPLETE 01/09/2026 01/12/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 01/09/2026 01/09/2026
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD HOLD 01/06/2026 01/06/2026
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Please provide Final building pad certification letter.
MECH COMPLETE 11/05/2025 11/06/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN COMPLETE 04/21/2025 04/25/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 04/21/2025 04/25/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 04/21/2025 04/29/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 04/21/2025 04/25/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/21/2025 04/21/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 04/21/2025 04/24/2025
LOCATE COMPLETE 04/21/2025 04/29/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 04/21/2025 04/24/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 04/21/2025 04/28/2025
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 04/21/2025 04/22/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SWALE COMPLETE 04/21/2025 05/08/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 06/04/2026
CONTRACTOR CHANGE ¤20.00 05/27/2026
PLAN REVIEW - REVISION ¤32.50 05/27/2026
PLAN REVIEW - REVISION ¤32.50 05/27/2026
REINSPECTION RESIDENTIAL ¤40.00 05/27/2026
REINSPECTION RESIDENTIAL ¤40.00 05/27/2026
RSI REINSPECTION 1 ¤35.00 05/27/2026
RSI REINSPECTION 1 ¤35.00 05/27/2026
RSI REINSPECTION 1 ¤35.00 05/27/2026
RSI REINSPECTION 1 ¤35.00 05/27/2026
WASTEWATER MAIN EXTENSION IMPA ¤2,189.82 10/24/2025
SURCHARGE FS 533.721 ¤12.28 10/24/2025
SURCHARGE - FS 468.631 ¤18.42 10/24/2025
SW ENG - FOUNDATION SURVEY ¤20.00 10/24/2025
SW ENG INSPECTION 80 ¤80.00 10/24/2025
SW ENG PRE APRON ¤30.00 10/24/2025
SW ENG - REVIEW 20 ¤20.00 10/24/2025
SW ENG RES REVIEW 200 ¤200.00 10/24/2025
WATER METER W/ TAP ¤2,326.93 10/24/2025
WASTEWATER PERM INSPECTION ¤80.00 10/24/2025
WASTEWATER PERM REVIEW ¤25.00 10/24/2025
SEWER CAPITAL FACILITY ¤3,930.70 10/24/2025
WATER CAPITAL FACILITY FEE ¤3,496.74 10/24/2025
WATER PERMIT REVIEW ¤25.00 10/24/2025
WATER MAIN EXTENSION IMPACT ¤854.40 10/24/2025
SITE PLAN 30 ¤30.00 10/24/2025
WATER- TURN ON ¤50.00 10/24/2025
ADJUSTMENT 10% (¤136.43) 10/24/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 10/24/2025
INSPECTION - RESIDENTIAL ¤1,039.50 10/24/2025
PLAN REVIEW - RESIDENTIAL ¤294.84 10/24/2025
FC IMPACT FEE EMS ¤62.00 10/24/2025
IMPACT FEE FIRE ¤434.51 10/24/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 10/24/2025
FC IMPACT FEE LIBRARY ¤268.00 10/24/2025
IMPACT FEE PARKS ¤1,828.01 10/24/2025
IMPACT FEE SCHOOL ¤5,450.00 10/24/2025
IMPACT FEE TRANSPORTATION ¤1,916.00 10/24/2025
PEP TANK INSTALL ¤756.74 10/24/2025
Fees Total Due: ¤0.00 Total Paid: ¤25,895.46