I want to search for...

Permit #2025041101

Permit Details

Status: COED

Parcel Id: 07-11-31-7023-00220-0310
CONDITIONED SPACE: 1681 sqft
GARAGE: 458 sqft
OPENED PORCH (WITH ROOF) : 274 sqft
Total Square Footage: 2413 sqft
Block: 00220
Subdivision: -
Job Phone: 352-433-8382
Location Address: 43 WHITTINGHAM LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 05/08/2025
NOC: RECORDED
Applicant name: ALFREDO E SCHEER
Owner: ESTELA LIVING LLC

Address

2601 S BAYSHORE DR

MIAMI, FL 33133

Lot: 0310
Contracted Stated Job Value: ¤175,000.00
Job Description: Single Family Residence
Type: CN

Contractor

ESTELA LIVING LLC
Status Location Address State License Number Phone
ACTIVE

237 S. DIXIE HWY, 4TH FLOOR

CORAL GABLES, FL 33133

CGC1534535 (Exp: 08/31/2026) 352-433-8382

Sub Contractors

JOSEPH HORATIO STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PARKWAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2026) 877-906-1113
JOSEPH H STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PKWY

SANFORD, FL 32771

CAC043953 (Exp: 08/31/2026) 877-906-1113
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 01/27/2026 FINAL APPROVED MKRASKI
BLD - BUILDING FINAL 12/18/2025 Disapproved -FEE REQUIRED MKRASKI
Note: 1. Stone missing around front exterior garage lights 2. Seal around 2'' conduits above meter main at soffit 3. Seal exterior penitration at Cat5 4. ODU whip can not emerge from grade liquid tight can not be used within 3' in areas subject to damage 5. Remove trash and extera building materials in garage 6. No hot water in home 7. T stat is not working, a/c not running 8. T stat wire in AHU closet must be sealed at ceiling penitration 9. 2 heater stickers are marked on unit with 2 differnt size breakers, remove the one not being used 10. E-cals do not match equipment installed 11. Tub and shower valves and sponts need to be sealed at tile 12. Master bedroom exhaust fan (toilet) not working
BLD - BUILDING FINAL 12/09/2025 CANCELLED BY APPLICANT MKRASKI
U-CROSS CONNECTION 12/09/2025 APPROVED BWRIGHT
WALL SHEATHING 12/09/2025 APPROVED MKRASKI
Note:
U -UTILITY RESIDENTIAL FINAL 12/09/2025 FINAL APPROVED BWRIGHT
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/03/2025 APPROVED TPOLACEK
Note: 11/14/2025 - PREVIOUS INSPECTION NOTES 11-14-25 TPOLACEK*** CULVERT INV ELEVATIONS MUST BE SHOWN ON FINAL SURVEY, THERE NEEDS TO BE MORE ELEVATION SHOTS ACROSS THE REAR OF THE STRUCTURE AT 10' OFF TO DETERMINE THE FALL, APPROVED SITE PLAN SHOWS PL,B,FL FINAL SURVEY DOES NOT SHOW PROPERTY LINE ELEVATIONS AT ALL AND IT DOES NOT INDICATE A BERM OR FLOW LINE. FRONT SWALE IS TO FLOW LEFT TO RIGHT FINAL SURVEY INDICATES A .22 RISE FROM LEFT PROPERTY LINE TO MIDDLE OF SWALE.
ROW FIELD SURVEY /GRADING CERTIFICATION 12/03/2025 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - STORMWATER FINAL 12/03/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - FINAL APRON (AFTER POUR) 12/03/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/14/2025 Disapproved - NO FEE TPOLACEK
Note: 11-14-25 TPOLACEK*** CULVERT INV ELEVATIONS MUST BE SHOWN ON FINAL SURVEY, THERE NEEDS TO BE MORE ELEVATION SHOTS ACROSS THE REAR OF THE STRUCTURE AT 10' OFF TO DETERMINE THE FALL, APPROVED SITE PLAN SHOWS PL,B,FL FINAL SURVEY DOES NOT SHOW PROPERTY LINE ELEVATIONS AT ALL AND IT DOES NOT INDICATE A BERM OR FLOW LINE. FRONT SWALE IS TO FLOW LEFT TO RIGHT FINAL SURVEY INDICATES A .22 RISE FROM LEFT PROPERTY LINE TO MIDDLE OF SWALE.
ROW- PRE-APRON (PRE-POUR) 10/16/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR.
ELECTRIC - EARLY POWER 10/01/2025 APPROVED - AS NOTED MKRASKI
Note: Emailed FPL @ 2:40pm
ROW - DRAINAGE 10/01/2025 APPROVED TPOLACEK
Note: 10-01-25 TPOLACEK*** GRADER IS ON SITE APPROVING AS NOTED. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/30/2025 - PREVIOUS INSPECTION NOTES 09-30-25 TPOLACEK*** NO CHANGES AND MORE SEDIMENT HAS WASHED INTO SWALE. NEXT INSPECTION 10-01-25 PHOTO ATTACHED +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/29/2025 - PREVIOUS INSPECTION NOTES 09-29-25 TPOLACEK**** NO CHANGES. BUILDER MUST CLEAR SWALE OF ALL WASHED OUT SEDIMENT AND OPEN SWALE. SILT FENCE IS DESIGNED TO KEEP SITE FROM WASHING INTO STORMWATER SYSTEM. THUS WAS DISCUSSED IN PERSON AND NO CHANGES HAVE BEEN MADE. PERMIT IS NOW PLACED ON HOLD UNTIL CONDITIONS ARE CORRECTED. 9/24/2025 - PREVIOUS INSPECTION NOTES 09-24-25 TPOLACEK*** SILT FENCE ALONG FRONT IS STILL NOT INSTALLED AS REQUIRED. SILT FENCE AROUND THE BACK IS FALLING DOWN AND NEEDS TO BE REESTABLISHED. BUILDER HAS 3 DAYS UNTIL PERMIT IS PLACED ON HOLD. 9/17/2025 - PREVIOUS INSPECTION NOTES TPOLACEK*** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day.
ROW - DRAINAGE 09/30/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 09-30-25 TPOLACEK*** NO CHANGES AND MORE SEDIMENT HAS WASHED INTO SWALE. NEXT INSPECTION 10-01-25 PHOTO ATTACHED +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/29/2025 - PREVIOUS INSPECTION NOTES 09-29-25 TPOLACEK**** NO CHANGES. BUILDER MUST CLEAR SWALE OF ALL WASHED OUT SEDIMENT AND OPEN SWALE. SILT FENCE IS DESIGNED TO KEEP SITE FROM WASHING INTO STORMWATER SYSTEM. THUS WAS DISCUSSED IN PERSON AND NO CHANGES HAVE BEEN MADE. PERMIT IS NOW PLACED ON HOLD UNTIL CONDITIONS ARE CORRECTED. 9/24/2025 - PREVIOUS INSPECTION NOTES 09-24-25 TPOLACEK*** SILT FENCE ALONG FRONT IS STILL NOT INSTALLED AS REQUIRED. SILT FENCE AROUND THE BACK IS FALLING DOWN AND NEEDS TO BE REESTABLISHED. BUILDER HAS 3 DAYS UNTIL PERMIT IS PLACED ON HOLD. 9/17/2025 - PREVIOUS INSPECTION NOTES TPOLACEK*** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day.
ROW - DRAINAGE 09/29/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 09-29-25 TPOLACEK**** NO CHANGES. BUILDER MUST CLEAR SWALE OF ALL WASHED OUT SEDIMENT AND OPEN SWALE. SILT FENCE IS DESIGNED TO KEEP SITE FROM WASHING INTO STORMWATER SYSTEM. THUS WAS DISCUSSED IN PERSON AND NO CHANGES HAVE BEEN MADE. PERMIT IS NOW PLACED ON HOLD UNTIL CONDITIONS ARE CORRECTED. 9/24/2025 - PREVIOUS INSPECTION NOTES 09-24-25 TPOLACEK*** SILT FENCE ALONG FRONT IS STILL NOT INSTALLED AS REQUIRED. SILT FENCE AROUND THE BACK IS FALLING DOWN AND NEEDS TO BE REESTABLISHED. BUILDER HAS 3 DAYS UNTIL PERMIT IS PLACED ON HOLD. 9/17/2025 - PREVIOUS INSPECTION NOTES TPOLACEK*** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day.
ROW - DRAINAGE 09/24/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 09-24-25 TPOLACEK*** SILT FENCE ALONG FRONT IS STILL NOT INSTALLED AS REQUIRED. SILT FENCE AROUND THE BACK IS FALLING DOWN AND NEEDS TO BE REESTABLISHED. BUILDER HAS 3 DAYS UNTIL PERMIT IS PLACED ON HOLD. 9/17/2025 - PREVIOUS INSPECTION NOTES TPOLACEK*** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day.
GRAVITY SEWER TEST 09/24/2025 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
SEWER TIE IN 09/24/2025 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2075 THIS WAS A VIRTUAL INSPECTION THIS WAS A VIRTUAL INSPECTION
ROW - DRAINAGE 09/17/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: TPOLACEK*** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day.
PEP TANK INSTALLATION REQUEST 09/02/2025 APPROVED CBOWERMASTER
LATH/BRICK/ WATER BARRIER 08/15/2025 APPROVED MCONTRYMAN
Note: Inspector Notes from Inspection 2490 *** NOTES ADDED BY RSIMS 8/14/2025 9:31:19 AM *** 8/13/25: NOTE: plywood overframing has been cut back to allow access for blown in insulation. Please make sure that cardboard baffles remain 1" minimum away from roof sheathing. FBC-R806.3 8/12/2025 - PREVIOUS INSPECTION NOTES 8/12/25 1. Batts required in areas that do not have enough space to have proper depth of blown in insulation (hips, rooms with over framing that is not accessiable)
INSULATION 08/14/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 8/14/2025 9:31:19 AM *** 8/13/25: NOTE: plywood overframing has been cut back to allow access for blown in insulation. Please make sure that cardboard baffles remain 1" minimum away from roof sheathing. FBC-R806.3 8/12/2025 - PREVIOUS INSPECTION NOTES 8/12/25 1. Batts required in areas that do not have enough space to have proper depth of blown in insulation (hips, rooms with over framing that is not accessiable)
INSULATION 08/12/2025 Disapproved - NO FEE MKRASKI
Note: *** NOTES ADDED BY MKRASKI 8/12/2025 10:49:15 AM *** ***Added wall sheathing inspection for removed wall sheathing at front entry knee wall*** 8/12/25 1. Batts required in areas that do not have enough space to have proper depth of blown in insulation (hips, rooms with over framing that is not accessiable)
ALL ROUGH 08/08/2025 APPROVED - AS NOTED MCONTRYMAN
Note: 8/8/25 1. No product approvals on site. Will check at insulation FBC(A) 107.3.1 --All other areas are good on inspection 8/7/2025 - PREVIOUS INSPECTION NOTES 8/7/25 Item #1 has not been repired per previous inspection, make all repairs before calling in for re-inspection a full all rough inspection is required once repair is made 7/28/25 1. Can not see double top plate or t/p to truss strap/screw per S-7 "A" for front entry knee walls (side walls) per plan 2. Truss A8 1 of 7 missing engineering per engineering packet Check at all rough 7/9/25 1. Please clean job box and have a clean set with Building Dept. stamp of approval plans with all engineering on site for inspection FBC 107.3.1 2. Knee wall at front entry walls not per detail S7-A and B FBC (A)107.4 3. Plans call for 2 HTS24s on truus's A and A15, HTS20s installed FBC (A)107.4 4. Missed wet set truss straps not installed per manufacturer specs (5) in a row. A letter will be required for repair. Have letter approved by Building Dept. before re-inspection FBC (A)107.4 5. Front porch straps not per detail S-5 FBC (A)107.4 6. No load bearing wall to wood frame wall connection detail FBC (A)107.4 7. Load bearing wall to truss connection missing SDWC screws FBC (A)107.4 8. Note on plans calls out front girder truss to have a 2-2x4 built up post. Girder lays out over CMU wall, a revision will be required FBC (A)107.4 9. Truss engineering was not looked at, the set onsite did not have Building Dept. stamp of approval FBC 107.3.1
ALL ROUGH 08/07/2025 Disapproved -FEE REQUIRED MKRASKI
Note: 8/7/25 Item #1 has not been repired per previous inspection, make all repairs before calling in for re-inspection a full all rough inspection is required once repair is made 7/28/25 1. Can not see double top plate or t/p to truss strap/screw per S-7 "A" for front entry knee walls (side walls) per plan 2. Truss A8 1 of 7 missing engineering per engineering packet Check at all rough 7/9/25 1. Please clean job box and have a clean set with Building Dept. stamp of approval plans with all engineering on site for inspection FBC 107.3.1 2. Knee wall at front entry walls not per detail S7-A and B FBC (A)107.4 3. Plans call for 2 HTS24s on truus's A and A15, HTS20s installed FBC (A)107.4 4. Missed wet set truss straps not installed per manufacturer specs (5) in a row. A letter will be required for repair. Have letter approved by Building Dept. before re-inspection FBC (A)107.4 5. Front porch straps not per detail S-5 FBC (A)107.4 6. No load bearing wall to wood frame wall connection detail FBC (A)107.4 7. Load bearing wall to truss connection missing SDWC screws FBC (A)107.4 8. Note on plans calls out front girder truss to have a 2-2x4 built up post. Girder lays out over CMU wall, a revision will be required FBC (A)107.4 9. Truss engineering was not looked at, the set onsite did not have Building Dept. stamp of approval FBC 107.3.1
ALL ROUGH 08/01/2025 CANCELLED BY APPLICANT MKRASKI
Note: Inspector Notes from Inspection 2460 7/28/25 1. Can not see double top plate or t/p to truss strap/screw per S-7 "A" for front entry knee walls (side walls) per plan 2. Truss A8 1 of 7 missing engineering per engineering packet Check at all rough 7/9/25 1. Please clean job box and have a clean set with Building Dept. stamp of approval plans with all engineering on site for inspection FBC 107.3.1 2. Knee wall at front entry walls not per detail S7-A and B FBC (A)107.4 3. Plans call for 2 HTS24s on truus's A and A15, HTS20s installed FBC (A)107.4 4. Missed wet set truss straps not installed per manufacturer specs (5) in a row. A letter will be required for repair. Have letter approved by Building Dept. before re-inspection FBC (A)107.4 5. Front porch straps not per detail S-5 FBC (A)107.4 6. No load bearing wall to wood frame wall connection detail FBC (A)107.4 7. Load bearing wall to truss connection missing SDWC screws FBC (A)107.4 8. Note on plans calls out front girder truss to have a 2-2x4 built up post. Girder lays out over CMU wall, a revision will be required FBC (A)107.4 9. Truss engineering was not looked at, the set onsite did not have Building Dept. stamp of approval FBC 107.3.1
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/28/2025 APPROVED - AS NOTED MKRASKI
Note: 7/28/25 1. Can not see double top plate or t/p to truss strap/screw per S-7 "A" for front entry knee walls (side walls) per plan 2. Truss A8 1 of 7 missing engineering per engineering packet Check at all rough 7/9/25 1. Please clean job box and have a clean set with Building Dept. stamp of approval plans with all engineering on site for inspection FBC 107.3.1 2. Knee wall at front entry walls not per detail S7-A and B FBC (A)107.4 3. Plans call for 2 HTS24s on truus's A and A15, HTS20s installed FBC (A)107.4 4. Missed wet set truss straps not installed per manufacturer specs (5) in a row. A letter will be required for repair. Have letter approved by Building Dept. before re-inspection FBC (A)107.4 5. Front porch straps not per detail S-5 FBC (A)107.4 6. No load bearing wall to wood frame wall connection detail FBC (A)107.4 7. Load bearing wall to truss connection missing SDWC screws FBC (A)107.4 8. Note on plans calls out front girder truss to have a 2-2x4 built up post. Girder lays out over CMU wall, a revision will be required FBC (A)107.4 9. Truss engineering was not looked at, the set onsite did not have Building Dept. stamp of approval FBC 107.3.1
ROOF VALLEY & METAL 07/16/2025 APPROVED MKRASKI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/15/2025 CANCELLED BY APPLICANT MKRASKI
Note: 7/15/25 Canceled via text 7/9/25 1. Please clean job box and have a clean set with Building Dept. stamp of approval plans with all engineering on site for inspection FBC 107.3.1 2. Knee wall at front entry walls not per detail S7-A and B FBC (A)107.4 3. Plans call for 2 HTS24s on truus's A and A15, HTS20s installed FBC (A)107.4 4. Missed wet set truss straps not installed per manufacturer specs (5) in a row. A letter will be required for repair. Have letter approved by Building Dept. before re-inspection FBC (A)107.4 5. Front porch straps not per detail S-5 FBC (A)107.4 6. No load bearing wall to wood frame wall connection detail FBC (A)107.4 7. Load bearing wall to truss connection missing SDWC screws FBC (A)107.4 8. Note on plans calls out front girder truss to have a 2-2x4 built up post. Girder lays out over CMU wall, a revision will be required FBC (A)107.4 9. Truss engineering was not looked at, the set onsite did not have Building Dept. stamp of approval FBC 107.3.1
ROOF VALLEY & METAL 07/15/2025 CANCELLED BY APPLICANT MKRASKI
Note: 7/15/25 Canceled via text
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/09/2025 Disapproved -FEE REQUIRED MKRASKI
Note: 1. Please clean job box and have a clean set with Building Dept. stamp of approval plans with all engineering on site for inspection FBC 107.3.1 2. Knee wall at front entry walls not per detail S7-A and B FBC (A)107.4 3. Plans call for 2 HTS24s on truus's A and A15, HTS20s installed FBC (A)107.4 4. Missed wet set truss straps not installed per manufacturer specs (5) in a row. A letter will be required for repair. Have letter approved by Building Dept. before re-inspection FBC (A)107.4 5. Front porch straps not per detail S-5 FBC (A)107.4 6. No load bearing wall to wood frame wall connection detail FBC (A)107.4 7. Load bearing wall to truss connection missing SDWC screws FBC (A)107.4 8. Note on plans calls out front girder truss to have a 2-2x4 built up post. Girder lays out over CMU wall, a revision will be required FBC (A)107.4 9. Truss engineering was not looked at, the set onsite did not have Building Dept. stamp of approval FBC 107.3.1
WALL SHEATHING 07/09/2025 APPROVED MKRASKI
TIE BEAM / LINTEL 06/26/2025 APPROVED MKRASKI
TIE BEAM / LINTEL 06/24/2025 Disapproved -FEE REQUIRED MCONTRYMAN
Note: 6/24/25 1. Sill joints exceed 1/2" max FBCR 606.3.1 2. Front right sill is cut to fit, no mortar on left side, and also exceeds 1/2" max joints FBCR 606.3.1 3. Stress crack already in block on left side 6/20/2025 - PREVIOUS INSPECTION NOTES 1. Bed joints on window sills exceed 1/2'' allowable max, check all FBCR 606.3.1
TIE BEAM / LINTEL 06/20/2025 Disapproved - NO FEE MKRASKI
Note: 1. Bed joints on window sills exceed 1/2'' allowable max, check all FBCR 606.3.1
TIE BEAM / LINTEL 06/18/2025 CANCELLED BY APPLICANT RSIMS
Note: *** NOTES ADDED BY RSIMS 6/18/2025 8:58:08 AM *** 6/18/25: Cancelled by Applicant via text at @ 08:56
MONOLITHIC SLAB 06/10/2025 APPROVED FWILLIS
FORMBOARD SURVEY (OFFICE USE ONLY) 06/06/2025 APPROVED TDOAK
PLUMBING 1ST ROUGH UNDERGROUND 06/06/2025 APPROVED MGIBSON
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 06/05/2025 APPROVED JMUNSON
WATER METER INSTALLATION REQUEST 05/23/2025 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 01/23/2026 01/26/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 01/16/2026 01/20/2026
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Design location on Heatload needs to be Daytona Beach
BLD COMPLETE 07/25/2025 07/28/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/06/2025 06/06/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 06/06/2025 06/06/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD HOLD 06/04/2025 06/04/2025
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Please provide initial Geotech report.
BLD COMPLETE 06/04/2025 06/05/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 05/02/2025 05/02/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
SW1 COMPLETE 05/02/2025 05/08/2025
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 05/02/2025 05/02/2025
Note: Released By: NICOLE DIMATTINA - - NDIMATTINA@PALMCOASTGOV.COM no zoning changes
SWALE COMPLETE 05/02/2025 05/27/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
BADMIN COMPLETE 04/21/2025 04/25/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 04/21/2025 04/25/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 04/21/2025 04/30/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 04/21/2025 04/25/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 HOLD 04/21/2025 04/22/2025
Note: Held By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM Include the proposed FFE on the site plan.
GAS CANCEL 04/21/2025 04/24/2025
LOCATE COMPLETE 04/21/2025 04/29/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 04/21/2025 04/24/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 04/21/2025 04/24/2025
Note: Held By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM -Please indicate the proposed FFE of this house. - There is a flat spot in the middle of the back yard. There shall positve fall every 20' - positive fall is considered 0.1' every 20' minimum.
ZON COMPLETE 04/21/2025 04/23/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 02/24/2026
REINSPECTION RESIDENTIAL ¤40.00 02/24/2026
REINSPECTION RESIDENTIAL ¤40.00 02/24/2026
REINSPECTION RESIDENTIAL ¤40.00 02/24/2026
REINSPECTION RESIDENTIAL ¤40.00 02/24/2026
SW ENG - INSPECTION 20 ¤20.00 02/24/2026
SW ENG - INSPECTION 20 ¤20.00 02/24/2026
SW ENG - INSPECTION 20 ¤20.00 02/24/2026
SW ENG - INSPECTION 20 ¤20.00 02/24/2026
SW ENG - INSPECTION 20 ¤20.00 02/24/2026
SW ENG INSPECTION 80 ¤80.00 05/08/2025
SW ENG PRE APRON ¤30.00 05/08/2025
SW ENG - REVIEW 20 ¤20.00 05/08/2025
SW ENG RES REVIEW 200 ¤200.00 05/08/2025
WATER METER W/ TAP ¤2,326.93 05/08/2025
SEWER CREDIT (¤1,147.00) 05/08/2025
WASTEWATER PERM INSPECTION ¤80.00 05/08/2025
WASTEWATER PERM REVIEW ¤25.00 05/08/2025
SEWER CAPITAL FACILITY ¤3,930.70 05/08/2025
WATER CAPITAL FACILITY FEE ¤3,496.74 05/08/2025
WATER PERMIT REVIEW ¤25.00 05/08/2025
WATER MAIN EXTENSION IMPACT ¤854.40 05/08/2025
SITE PLAN 30 ¤30.00 05/08/2025
FC IMPACT FEE EMS ¤62.00 05/08/2025
IMPACT FEE FIRE ¤434.51 05/08/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 05/08/2025
FC IMPACT FEE LIBRARY ¤268.00 05/08/2025
IMPACT FEE PARKS ¤1,828.01 05/08/2025
IMPACT FEE SCHOOL ¤5,450.00 05/08/2025
IMPACT FEE TRANSPORTATION ¤1,916.00 05/08/2025
PEP TANK INSTALL ¤756.74 05/08/2025
WASTEWATER MAIN EXTENSION IMPA ¤2,189.82 05/08/2025
SURCHARGE FS 533.721 ¤10.72 05/08/2025
SURCHARGE - FS 468.631 ¤16.08 05/08/2025
SW ENG - FOUNDATION SURVEY ¤20.00 05/08/2025
WATER- TURN ON ¤50.00 05/08/2025
ADJUSTMENT 10% (¤119.14) 05/08/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 05/08/2025
INSPECTION - RESIDENTIAL ¤904.75 05/08/2025
PLAN REVIEW - RESIDENTIAL ¤256.62 05/08/2025
Fees Total Due: ¤0.00 Total Paid: ¤24,536.38