I want to search for...
Permit #2025041101
Permit Details
Status: COED
| Parcel Id: 07-11-31-7023-00220-0310 |
| CONDITIONED SPACE: 1681 sqft |
| GARAGE: 458 sqft |
| OPENED PORCH (WITH ROOF) : 274 sqft |
| Total Square Footage: 2413 sqft |
| Block: 00220 |
| Subdivision: - |
| Job Phone: 352-433-8382 |
| Location Address: 43 WHITTINGHAM LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 05/08/2025 |
| NOC: RECORDED |
| Applicant name: ALFREDO E SCHEER |
| Owner: ESTELA LIVING LLC |
|
Address 2601 S BAYSHORE DR MIAMI, FL 33133 |
| Lot: 0310 |
| Contracted Stated Job Value: ¤175,000.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
ESTELA LIVING LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
237 S. DIXIE HWY, 4TH FLOOR CORAL GABLES, FL 33133 |
CGC1534535 (Exp: 08/31/2026) | 352-433-8382 |
Sub Contractors
JOSEPH HORATIO STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PARKWAY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2026) | 877-906-1113 |
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PKWY SANFORD, FL 32771 |
CAC043953 (Exp: 08/31/2026) | 877-906-1113 |
DUSTIN L ESTEP
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2041 N HIAWASSEE RD APOPKA, FL 32703 |
CCC1330971 (Exp: 08/31/2026) | 407-702-0206 | 352-988-6629 |
JUAN CARLOS GONZALEZ
| Status | Location Address | State License Number |
| ACTIVE |
1328 COUNTY ROAD 308 CRESCENT CITY, FL 32112 |
RF11067806 (Exp: 08/31/2027) |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 01/27/2026 | FINAL APPROVED | MKRASKI |
| BLD - BUILDING FINAL | 12/18/2025 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 1. Stone missing around front exterior garage lights 2. Seal around 2'' conduits above meter main at soffit 3. Seal exterior penitration at Cat5 4. ODU whip can not emerge from grade liquid tight can not be used within 3' in areas subject to damage 5. Remove trash and extera building materials in garage 6. No hot water in home 7. T stat is not working, a/c not running 8. T stat wire in AHU closet must be sealed at ceiling penitration 9. 2 heater stickers are marked on unit with 2 differnt size breakers, remove the one not being used 10. E-cals do not match equipment installed 11. Tub and shower valves and sponts need to be sealed at tile 12. Master bedroom exhaust fan (toilet) not working | |||
| BLD - BUILDING FINAL | 12/09/2025 | CANCELLED BY APPLICANT | MKRASKI |
| U-CROSS CONNECTION | 12/09/2025 | APPROVED | BWRIGHT |
| WALL SHEATHING | 12/09/2025 | APPROVED | MKRASKI |
| Note: | |||
| U -UTILITY RESIDENTIAL FINAL | 12/09/2025 | FINAL APPROVED | BWRIGHT |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/03/2025 | APPROVED | TPOLACEK |
| Note: 11/14/2025 - PREVIOUS INSPECTION NOTES 11-14-25 TPOLACEK*** CULVERT INV ELEVATIONS MUST BE SHOWN ON FINAL SURVEY, THERE NEEDS TO BE MORE ELEVATION SHOTS ACROSS THE REAR OF THE STRUCTURE AT 10' OFF TO DETERMINE THE FALL, APPROVED SITE PLAN SHOWS PL,B,FL FINAL SURVEY DOES NOT SHOW PROPERTY LINE ELEVATIONS AT ALL AND IT DOES NOT INDICATE A BERM OR FLOW LINE. FRONT SWALE IS TO FLOW LEFT TO RIGHT FINAL SURVEY INDICATES A .22 RISE FROM LEFT PROPERTY LINE TO MIDDLE OF SWALE. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 12/03/2025 | APPROVED | TPOLACEK |
| Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - STORMWATER FINAL | 12/03/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - FINAL APRON (AFTER POUR) | 12/03/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 11/14/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 11-14-25 TPOLACEK*** CULVERT INV ELEVATIONS MUST BE SHOWN ON FINAL SURVEY, THERE NEEDS TO BE MORE ELEVATION SHOTS ACROSS THE REAR OF THE STRUCTURE AT 10' OFF TO DETERMINE THE FALL, APPROVED SITE PLAN SHOWS PL,B,FL FINAL SURVEY DOES NOT SHOW PROPERTY LINE ELEVATIONS AT ALL AND IT DOES NOT INDICATE A BERM OR FLOW LINE. FRONT SWALE IS TO FLOW LEFT TO RIGHT FINAL SURVEY INDICATES A .22 RISE FROM LEFT PROPERTY LINE TO MIDDLE OF SWALE. | |||
| ROW- PRE-APRON (PRE-POUR) | 10/16/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. | |||
| ELECTRIC - EARLY POWER | 10/01/2025 | APPROVED - AS NOTED | MKRASKI |
| Note: Emailed FPL @ 2:40pm | |||
| ROW - DRAINAGE | 10/01/2025 | APPROVED | TPOLACEK |
| Note: 10-01-25 TPOLACEK*** GRADER IS ON SITE APPROVING AS NOTED. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/30/2025 - PREVIOUS INSPECTION NOTES 09-30-25 TPOLACEK*** NO CHANGES AND MORE SEDIMENT HAS WASHED INTO SWALE. NEXT INSPECTION 10-01-25 PHOTO ATTACHED +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/29/2025 - PREVIOUS INSPECTION NOTES 09-29-25 TPOLACEK**** NO CHANGES. BUILDER MUST CLEAR SWALE OF ALL WASHED OUT SEDIMENT AND OPEN SWALE. SILT FENCE IS DESIGNED TO KEEP SITE FROM WASHING INTO STORMWATER SYSTEM. THUS WAS DISCUSSED IN PERSON AND NO CHANGES HAVE BEEN MADE. PERMIT IS NOW PLACED ON HOLD UNTIL CONDITIONS ARE CORRECTED. 9/24/2025 - PREVIOUS INSPECTION NOTES 09-24-25 TPOLACEK*** SILT FENCE ALONG FRONT IS STILL NOT INSTALLED AS REQUIRED. SILT FENCE AROUND THE BACK IS FALLING DOWN AND NEEDS TO BE REESTABLISHED. BUILDER HAS 3 DAYS UNTIL PERMIT IS PLACED ON HOLD. 9/17/2025 - PREVIOUS INSPECTION NOTES TPOLACEK*** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day. | |||
| ROW - DRAINAGE | 09/30/2025 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 09-30-25 TPOLACEK*** NO CHANGES AND MORE SEDIMENT HAS WASHED INTO SWALE. NEXT INSPECTION 10-01-25 PHOTO ATTACHED +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/29/2025 - PREVIOUS INSPECTION NOTES 09-29-25 TPOLACEK**** NO CHANGES. BUILDER MUST CLEAR SWALE OF ALL WASHED OUT SEDIMENT AND OPEN SWALE. SILT FENCE IS DESIGNED TO KEEP SITE FROM WASHING INTO STORMWATER SYSTEM. THUS WAS DISCUSSED IN PERSON AND NO CHANGES HAVE BEEN MADE. PERMIT IS NOW PLACED ON HOLD UNTIL CONDITIONS ARE CORRECTED. 9/24/2025 - PREVIOUS INSPECTION NOTES 09-24-25 TPOLACEK*** SILT FENCE ALONG FRONT IS STILL NOT INSTALLED AS REQUIRED. SILT FENCE AROUND THE BACK IS FALLING DOWN AND NEEDS TO BE REESTABLISHED. BUILDER HAS 3 DAYS UNTIL PERMIT IS PLACED ON HOLD. 9/17/2025 - PREVIOUS INSPECTION NOTES TPOLACEK*** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day. | |||
| ROW - DRAINAGE | 09/29/2025 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 09-29-25 TPOLACEK**** NO CHANGES. BUILDER MUST CLEAR SWALE OF ALL WASHED OUT SEDIMENT AND OPEN SWALE. SILT FENCE IS DESIGNED TO KEEP SITE FROM WASHING INTO STORMWATER SYSTEM. THUS WAS DISCUSSED IN PERSON AND NO CHANGES HAVE BEEN MADE. PERMIT IS NOW PLACED ON HOLD UNTIL CONDITIONS ARE CORRECTED. 9/24/2025 - PREVIOUS INSPECTION NOTES 09-24-25 TPOLACEK*** SILT FENCE ALONG FRONT IS STILL NOT INSTALLED AS REQUIRED. SILT FENCE AROUND THE BACK IS FALLING DOWN AND NEEDS TO BE REESTABLISHED. BUILDER HAS 3 DAYS UNTIL PERMIT IS PLACED ON HOLD. 9/17/2025 - PREVIOUS INSPECTION NOTES TPOLACEK*** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day. | |||
| ROW - DRAINAGE | 09/24/2025 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 09-24-25 TPOLACEK*** SILT FENCE ALONG FRONT IS STILL NOT INSTALLED AS REQUIRED. SILT FENCE AROUND THE BACK IS FALLING DOWN AND NEEDS TO BE REESTABLISHED. BUILDER HAS 3 DAYS UNTIL PERMIT IS PLACED ON HOLD. 9/17/2025 - PREVIOUS INSPECTION NOTES TPOLACEK*** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day. | |||
| GRAVITY SEWER TEST | 09/24/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| SEWER TIE IN | 09/24/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: Inspector Notes from Inspection 2075 THIS WAS A VIRTUAL INSPECTION THIS WAS A VIRTUAL INSPECTION | |||
| ROW - DRAINAGE | 09/17/2025 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: TPOLACEK*** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day. | |||
| PEP TANK INSTALLATION REQUEST | 09/02/2025 | APPROVED | CBOWERMASTER |
| LATH/BRICK/ WATER BARRIER | 08/15/2025 | APPROVED | MCONTRYMAN |
| Note: Inspector Notes from Inspection 2490 *** NOTES ADDED BY RSIMS 8/14/2025 9:31:19 AM *** 8/13/25: NOTE: plywood overframing has been cut back to allow access for blown in insulation. Please make sure that cardboard baffles remain 1" minimum away from roof sheathing. FBC-R806.3 8/12/2025 - PREVIOUS INSPECTION NOTES 8/12/25 1. Batts required in areas that do not have enough space to have proper depth of blown in insulation (hips, rooms with over framing that is not accessiable) | |||
| INSULATION | 08/14/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 8/14/2025 9:31:19 AM *** 8/13/25: NOTE: plywood overframing has been cut back to allow access for blown in insulation. Please make sure that cardboard baffles remain 1" minimum away from roof sheathing. FBC-R806.3 8/12/2025 - PREVIOUS INSPECTION NOTES 8/12/25 1. Batts required in areas that do not have enough space to have proper depth of blown in insulation (hips, rooms with over framing that is not accessiable) | |||
| INSULATION | 08/12/2025 | Disapproved - NO FEE | MKRASKI |
| Note: *** NOTES ADDED BY MKRASKI 8/12/2025 10:49:15 AM *** ***Added wall sheathing inspection for removed wall sheathing at front entry knee wall*** 8/12/25 1. Batts required in areas that do not have enough space to have proper depth of blown in insulation (hips, rooms with over framing that is not accessiable) | |||
| ALL ROUGH | 08/08/2025 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 8/8/25 1. No product approvals on site. Will check at insulation FBC(A) 107.3.1 --All other areas are good on inspection 8/7/2025 - PREVIOUS INSPECTION NOTES 8/7/25 Item #1 has not been repired per previous inspection, make all repairs before calling in for re-inspection a full all rough inspection is required once repair is made 7/28/25 1. Can not see double top plate or t/p to truss strap/screw per S-7 "A" for front entry knee walls (side walls) per plan 2. Truss A8 1 of 7 missing engineering per engineering packet Check at all rough 7/9/25 1. Please clean job box and have a clean set with Building Dept. stamp of approval plans with all engineering on site for inspection FBC 107.3.1 2. Knee wall at front entry walls not per detail S7-A and B FBC (A)107.4 3. Plans call for 2 HTS24s on truus's A and A15, HTS20s installed FBC (A)107.4 4. Missed wet set truss straps not installed per manufacturer specs (5) in a row. A letter will be required for repair. Have letter approved by Building Dept. before re-inspection FBC (A)107.4 5. Front porch straps not per detail S-5 FBC (A)107.4 6. No load bearing wall to wood frame wall connection detail FBC (A)107.4 7. Load bearing wall to truss connection missing SDWC screws FBC (A)107.4 8. Note on plans calls out front girder truss to have a 2-2x4 built up post. Girder lays out over CMU wall, a revision will be required FBC (A)107.4 9. Truss engineering was not looked at, the set onsite did not have Building Dept. stamp of approval FBC 107.3.1 | |||
| ALL ROUGH | 08/07/2025 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 8/7/25 Item #1 has not been repired per previous inspection, make all repairs before calling in for re-inspection a full all rough inspection is required once repair is made 7/28/25 1. Can not see double top plate or t/p to truss strap/screw per S-7 "A" for front entry knee walls (side walls) per plan 2. Truss A8 1 of 7 missing engineering per engineering packet Check at all rough 7/9/25 1. Please clean job box and have a clean set with Building Dept. stamp of approval plans with all engineering on site for inspection FBC 107.3.1 2. Knee wall at front entry walls not per detail S7-A and B FBC (A)107.4 3. Plans call for 2 HTS24s on truus's A and A15, HTS20s installed FBC (A)107.4 4. Missed wet set truss straps not installed per manufacturer specs (5) in a row. A letter will be required for repair. Have letter approved by Building Dept. before re-inspection FBC (A)107.4 5. Front porch straps not per detail S-5 FBC (A)107.4 6. No load bearing wall to wood frame wall connection detail FBC (A)107.4 7. Load bearing wall to truss connection missing SDWC screws FBC (A)107.4 8. Note on plans calls out front girder truss to have a 2-2x4 built up post. Girder lays out over CMU wall, a revision will be required FBC (A)107.4 9. Truss engineering was not looked at, the set onsite did not have Building Dept. stamp of approval FBC 107.3.1 | |||
| ALL ROUGH | 08/01/2025 | CANCELLED BY APPLICANT | MKRASKI |
| Note: Inspector Notes from Inspection 2460 7/28/25 1. Can not see double top plate or t/p to truss strap/screw per S-7 "A" for front entry knee walls (side walls) per plan 2. Truss A8 1 of 7 missing engineering per engineering packet Check at all rough 7/9/25 1. Please clean job box and have a clean set with Building Dept. stamp of approval plans with all engineering on site for inspection FBC 107.3.1 2. Knee wall at front entry walls not per detail S7-A and B FBC (A)107.4 3. Plans call for 2 HTS24s on truus's A and A15, HTS20s installed FBC (A)107.4 4. Missed wet set truss straps not installed per manufacturer specs (5) in a row. A letter will be required for repair. Have letter approved by Building Dept. before re-inspection FBC (A)107.4 5. Front porch straps not per detail S-5 FBC (A)107.4 6. No load bearing wall to wood frame wall connection detail FBC (A)107.4 7. Load bearing wall to truss connection missing SDWC screws FBC (A)107.4 8. Note on plans calls out front girder truss to have a 2-2x4 built up post. Girder lays out over CMU wall, a revision will be required FBC (A)107.4 9. Truss engineering was not looked at, the set onsite did not have Building Dept. stamp of approval FBC 107.3.1 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/28/2025 | APPROVED - AS NOTED | MKRASKI |
| Note: 7/28/25 1. Can not see double top plate or t/p to truss strap/screw per S-7 "A" for front entry knee walls (side walls) per plan 2. Truss A8 1 of 7 missing engineering per engineering packet Check at all rough 7/9/25 1. Please clean job box and have a clean set with Building Dept. stamp of approval plans with all engineering on site for inspection FBC 107.3.1 2. Knee wall at front entry walls not per detail S7-A and B FBC (A)107.4 3. Plans call for 2 HTS24s on truus's A and A15, HTS20s installed FBC (A)107.4 4. Missed wet set truss straps not installed per manufacturer specs (5) in a row. A letter will be required for repair. Have letter approved by Building Dept. before re-inspection FBC (A)107.4 5. Front porch straps not per detail S-5 FBC (A)107.4 6. No load bearing wall to wood frame wall connection detail FBC (A)107.4 7. Load bearing wall to truss connection missing SDWC screws FBC (A)107.4 8. Note on plans calls out front girder truss to have a 2-2x4 built up post. Girder lays out over CMU wall, a revision will be required FBC (A)107.4 9. Truss engineering was not looked at, the set onsite did not have Building Dept. stamp of approval FBC 107.3.1 | |||
| ROOF VALLEY & METAL | 07/16/2025 | APPROVED | MKRASKI |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/15/2025 | CANCELLED BY APPLICANT | MKRASKI |
| Note: 7/15/25 Canceled via text 7/9/25 1. Please clean job box and have a clean set with Building Dept. stamp of approval plans with all engineering on site for inspection FBC 107.3.1 2. Knee wall at front entry walls not per detail S7-A and B FBC (A)107.4 3. Plans call for 2 HTS24s on truus's A and A15, HTS20s installed FBC (A)107.4 4. Missed wet set truss straps not installed per manufacturer specs (5) in a row. A letter will be required for repair. Have letter approved by Building Dept. before re-inspection FBC (A)107.4 5. Front porch straps not per detail S-5 FBC (A)107.4 6. No load bearing wall to wood frame wall connection detail FBC (A)107.4 7. Load bearing wall to truss connection missing SDWC screws FBC (A)107.4 8. Note on plans calls out front girder truss to have a 2-2x4 built up post. Girder lays out over CMU wall, a revision will be required FBC (A)107.4 9. Truss engineering was not looked at, the set onsite did not have Building Dept. stamp of approval FBC 107.3.1 | |||
| ROOF VALLEY & METAL | 07/15/2025 | CANCELLED BY APPLICANT | MKRASKI |
| Note: 7/15/25 Canceled via text | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/09/2025 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 1. Please clean job box and have a clean set with Building Dept. stamp of approval plans with all engineering on site for inspection FBC 107.3.1 2. Knee wall at front entry walls not per detail S7-A and B FBC (A)107.4 3. Plans call for 2 HTS24s on truus's A and A15, HTS20s installed FBC (A)107.4 4. Missed wet set truss straps not installed per manufacturer specs (5) in a row. A letter will be required for repair. Have letter approved by Building Dept. before re-inspection FBC (A)107.4 5. Front porch straps not per detail S-5 FBC (A)107.4 6. No load bearing wall to wood frame wall connection detail FBC (A)107.4 7. Load bearing wall to truss connection missing SDWC screws FBC (A)107.4 8. Note on plans calls out front girder truss to have a 2-2x4 built up post. Girder lays out over CMU wall, a revision will be required FBC (A)107.4 9. Truss engineering was not looked at, the set onsite did not have Building Dept. stamp of approval FBC 107.3.1 | |||
| WALL SHEATHING | 07/09/2025 | APPROVED | MKRASKI |
| TIE BEAM / LINTEL | 06/26/2025 | APPROVED | MKRASKI |
| TIE BEAM / LINTEL | 06/24/2025 | Disapproved -FEE REQUIRED | MCONTRYMAN |
| Note: 6/24/25 1. Sill joints exceed 1/2" max FBCR 606.3.1 2. Front right sill is cut to fit, no mortar on left side, and also exceeds 1/2" max joints FBCR 606.3.1 3. Stress crack already in block on left side 6/20/2025 - PREVIOUS INSPECTION NOTES 1. Bed joints on window sills exceed 1/2'' allowable max, check all FBCR 606.3.1 | |||
| TIE BEAM / LINTEL | 06/20/2025 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Bed joints on window sills exceed 1/2'' allowable max, check all FBCR 606.3.1 | |||
| TIE BEAM / LINTEL | 06/18/2025 | CANCELLED BY APPLICANT | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 6/18/2025 8:58:08 AM *** 6/18/25: Cancelled by Applicant via text at @ 08:56 | |||
| MONOLITHIC SLAB | 06/10/2025 | APPROVED | FWILLIS |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 06/06/2025 | APPROVED | TDOAK |
| PLUMBING 1ST ROUGH UNDERGROUND | 06/06/2025 | APPROVED | MGIBSON |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 06/05/2025 | APPROVED | JMUNSON |
| WATER METER INSTALLATION REQUEST | 05/23/2025 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 01/23/2026 | 01/26/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 01/16/2026 | 01/20/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Design location on Heatload needs to be Daytona Beach | |||
| BLD | COMPLETE | 07/25/2025 | 07/28/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 06/06/2025 | 06/06/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 06/06/2025 | 06/06/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | HOLD | 06/04/2025 | 06/04/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Please provide initial Geotech report. | |||
| BLD | COMPLETE | 06/04/2025 | 06/05/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 05/02/2025 | 05/02/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 05/02/2025 | 05/08/2025 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/02/2025 | 05/02/2025 |
| Note: Released By: NICOLE DIMATTINA - - NDIMATTINA@PALMCOASTGOV.COM no zoning changes | |||
| SWALE | COMPLETE | 05/02/2025 | 05/27/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 04/21/2025 | 04/25/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/21/2025 | 04/25/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 04/21/2025 | 04/30/2025 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 04/21/2025 | 04/25/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | HOLD | 04/21/2025 | 04/22/2025 |
| Note: Held By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM Include the proposed FFE on the site plan. | |||
| GAS | CANCEL | 04/21/2025 | 04/24/2025 |
| LOCATE | COMPLETE | 04/21/2025 | 04/29/2025 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 04/21/2025 | 04/24/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 04/21/2025 | 04/24/2025 |
| Note: Held By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM -Please indicate the proposed FFE of this house. - There is a flat spot in the middle of the back yard. There shall positve fall every 20' - positive fall is considered 0.1' every 20' minimum. | |||
| ZON | COMPLETE | 04/21/2025 | 04/23/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 02/24/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/24/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/24/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/24/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/24/2026 |
| SW ENG - INSPECTION 20 | ¤20.00 | 02/24/2026 |
| SW ENG - INSPECTION 20 | ¤20.00 | 02/24/2026 |
| SW ENG - INSPECTION 20 | ¤20.00 | 02/24/2026 |
| SW ENG - INSPECTION 20 | ¤20.00 | 02/24/2026 |
| SW ENG - INSPECTION 20 | ¤20.00 | 02/24/2026 |
| SW ENG INSPECTION 80 | ¤80.00 | 05/08/2025 |
| SW ENG PRE APRON | ¤30.00 | 05/08/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 05/08/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 05/08/2025 |
| WATER METER W/ TAP | ¤2,326.93 | 05/08/2025 |
| SEWER CREDIT | (¤1,147.00) | 05/08/2025 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 05/08/2025 |
| WASTEWATER PERM REVIEW | ¤25.00 | 05/08/2025 |
| SEWER CAPITAL FACILITY | ¤3,930.70 | 05/08/2025 |
| WATER CAPITAL FACILITY FEE | ¤3,496.74 | 05/08/2025 |
| WATER PERMIT REVIEW | ¤25.00 | 05/08/2025 |
| WATER MAIN EXTENSION IMPACT | ¤854.40 | 05/08/2025 |
| SITE PLAN 30 | ¤30.00 | 05/08/2025 |
| FC IMPACT FEE EMS | ¤62.00 | 05/08/2025 |
| IMPACT FEE FIRE | ¤434.51 | 05/08/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 05/08/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 05/08/2025 |
| IMPACT FEE PARKS | ¤1,828.01 | 05/08/2025 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 05/08/2025 |
| IMPACT FEE TRANSPORTATION | ¤1,916.00 | 05/08/2025 |
| PEP TANK INSTALL | ¤756.74 | 05/08/2025 |
| WASTEWATER MAIN EXTENSION IMPA | ¤2,189.82 | 05/08/2025 |
| SURCHARGE FS 533.721 | ¤10.72 | 05/08/2025 |
| SURCHARGE - FS 468.631 | ¤16.08 | 05/08/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 05/08/2025 |
| WATER- TURN ON | ¤50.00 | 05/08/2025 |
| ADJUSTMENT 10% | (¤119.14) | 05/08/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 05/08/2025 |
| INSPECTION - RESIDENTIAL | ¤904.75 | 05/08/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤256.62 | 05/08/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤24,536.38 |