I want to search for...

Permit #2025041102

Permit Details

Status: COED

Parcel Id: 07-11-31-7034-01220-0020
CONDITIONED SPACE: 2332 sqft
GARAGE: 508 sqft
OPENED PORCH (WITH ROOF) : 259 sqft
Total Square Footage: 3099 sqft
Block: 01220
Subdivision: -
Job Phone: 352-433-8382
Location Address: 5 EDMOND PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/02/2025
NOC: RECORDED
Applicant name: ALFREDO E SCHEER
Owner: ESTELA LIVING LLC

Address

2601 SOUTH BAYSHORE DRIVE

COCONUT GROVE, FL 33133

Address

18TH FLOOR

COCONUT GROVE, FL 33133

Lot: 0020
Contracted Stated Job Value: ¤200,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

ESTELA LIVING LLC
Status Location Address State License Number Phone
ACTIVE

237 S. DIXIE HWY, 4TH FLOOR

CORAL GABLES, FL 33133

CGC1534535 (Exp: 08/31/2026) 352-433-8382

Sub Contractors

JOSEPH HORATIO STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PARKWAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2026) 877-906-1113
JOSEPH H STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PKWY

SANFORD, FL 32771

CAC043953 (Exp: 08/31/2026) 877-906-1113
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 01/30/2026 FINAL APPROVED MCONTRYMAN
Note: Inspector Notes from Inspection 2490 11/14/25 Energy calcs show a 6" range vent being installed and going through the roof. Please revise, and have approved, energy calcs, if omitting this vent by final Inspector Notes from Inspection 2320 Ecalcs were not approved at time of this inspection. Check HVAC layout on insulation. Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 11/7/2025 2:26:09 PM *** 11/7/25: APPROVED AS NOTED. 1). Installed ductwork does not match the Duct layout shown on the Energy Calcs. Revision required. FBC [A]107.4 NOTE: TEMPORARY CULVERT PIPE HAS BEEN REMOVED HOWEVER SWALE HAS BEEN CONDITIONED TO ALLOW FREE FLOW OF WATER THROUGH THE SWALE. SWALE WILL NEED TO TO BE MAINTAINED TO REMAIN IN IT'S CURRENT CONDITION THROUGHOUT THE BUILD PROCESS UNTIL FINAL GRADE IS COMPLETED. Inspector Notes from Inspection 2460 11/5/25 1. Clean all truss's of debris per manufacturer spec 2. Silt needs repair. FBC 3307.1 3. Temporary culvert needs to be replaced to allow for free flow of water through the swale. FBC 3303.5 Make all repairs before next inspection
U -UTILITY RESIDENTIAL FINAL 01/30/2026 FINAL APPROVED BHAINES
Note: Inspector Notes from Inspection 9035 No CC, No IRR
ROW - DRAINAGE 01/29/2026 APPROVED FSLADISH
Note: 1/15/2026 - PREVIOUS INSPECTION NOTES 01-15-26 TPOLACEK*** NO CHANGES TO SITE CONDITIONS. WILL REWTURN TOMORROW FOR FOLLOW UP 1/14/2026 - PREVIOUS INSPECTION NOTES 1/14/26 BUILDER IS REQUIRED TO REPAIR/REPLACE/RESET SILT FENCE. YOU ARE REQUIRED TO MOVE PORTA JOHN ONTO YOUR SITE. SEE PHOTO FOR REFERENCE. SEEING HOW THIS PERMIT HAS HAD SEVERAL PRIOR DRAINGE INSPECTIONS YOU ARE REQUIRED TO MAKE CORRECTIONS IMMEDIATELY. WILL BE BACK FOR COMLIANCE REINSPECTION ON 1/15/26 ________________________________________________________________________________________________________________________________ 10/21/2025 - PREVIOUS INSPECTION NOTES 10/21/25 YOUR CULVERT PIPE IS CRUSHED AND FULL OF DEBRIS. THE SWALE IS FULL OF DEEP RUTS AND IS NOT FLOWING. YOUR SILT FENCE NEEDS REPAIR. YOUR PORTA POTTY IS IN THE COPC ROW. PLEASE MAKE CORRECTIONS. SEE PHOTO FOR REFERENCE. Inspector Notes from Inspection 9470 9/16/25 SPOKE WITH DOUG CM ON 9/15/25 WHO INDICATED HE HAD BEEN OUT OF TOWN ON VACATION THE PREVIOUS WEEK. HE INDICATED HE WAS HEADING TO 5 EDMOND TO MEET UP WITH EARL GRADER TO BRING SITE INTO COMPLIANCE. I TOLD HIM THAT I WOULD HOLD OFF ON MY DRAINAGE INSPECTION UNTIL TODAY 9/16/25 AS A COURTESY. UPON WALKING SITE I HAVE DETERMINED THAT AT THE TIME OF THIS INSPECTION THEY ARE IN COMPLIANCE WITH COPC STANDARDS. I WILL CONTINUE TO MONITOR THIS SITE THROUGHOUT THE CONSTRUTION PROCESS FOR CONTINUED COMPLIANCE. APPROVING AS NOTED. ________________________________________________________________________________________________________________________ 9/12/2025 - PREVIOUS INSPECTION NOTES 9/12/25 NO CHANGES AT THE TIME OF THIS DRAINAGE INSPECTION. A PERMIT INSPECTION HOLD HAS BEEN PLACED ON THIS PERMIT. WILL BE BACK ON 9/15 FOR RECOMPLIANCE INSPECTION AT WHICH TIME A STOP WORK ORDER MAY BE PLACED ON THIS PERMIT. 9/11/2025 - PREVIOUS INSPECTION NOTES 9/11/25 NOTHING HAS CHANGED AT THE TIME OF THIS INSPECTION. PLEASE SEE PREVIOUS INSPECTION NOTES AND UPDATED PHOTO FROM 9/11/25. COMPLIANCE REINSPECTION 9/12/25. 9/9/2025 - PREVIOUS INSPECTION NOTES 1) THE SILT FENCE IS INSTALLED INCORRECTLY ALL SILT FENCE NEED TO BE BURIED 4" SO SOIL NOT GO UNDER SILT FENCE. ALSO THE SILT FENCE IS DOWN ON THE LEFT SIDE OF PROPERTY. 2) FRON LAST NIGHTS RAIN SILT AND SEDIMENT HAS WASHED IN TO DRAINAGE SYSTEM NEED TO CLEAR ALL AREAS SO WATER CAN FLOW CORRECTLY 3) ALL TRASH AND CONSTRCTION DEBRIS NEEDS TO BE PICK UP AND PUT IN DUMPSTER. ------------------------------------------------------------------------------------------ 9/8/2025 - PREVIOUS INSPECTION NOTES YOU STILL NEED TO DO THE FOLLOWING NEED TO INSTALL SILT FENCE ACROSSED THE FRONT OF THE PROPERTY AND INSTALL SILT FENCE ON SITE NOW TO CITY STANDARDS BY TRENCHING SILT FENCE IN AT A MINIMUM 4". ------------------------------------------------------------------------------------------- 9/3/2025 - PREVIOUS INSPECTION NOTES 1) NEED TO INSTALL SILT FENCE ACROSSED THE FRONT OF THE PROPERTY AND INSTALL SILT FENCE ON SITE NOW TO CITY STANDARDS BY TRENCHING SILT FENCE IN AT A MINIMUM 4". 2) NEED TO CLEAN ALL DIRT AND SEDIMENT OUT OF THE ROAD SIDE SWALE AND CREATE A ENTERANCE FOR YOUR SITE WITH A TEMP. CULVERT. YOU WILL HAVE 5 DAY TO CORRECT ALL ISSUE OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT.
ROW - STORMWATER FINAL 01/29/2026 APPROVED FSLADISH
Note: 1/29/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - FINAL APRON (AFTER POUR) 01/29/2026 APPROVED FSLADISH
Note: 1/29/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/29/2026 APPROVED - AS NOTED FSLADISH
Note: 1/29/26 SURVEY STILL SHOWS CULVERT PIPE OUT OF TOLERANCE TO THE COPC SWALE PLAN DIAGRAM. I WENT OIT AND SHOT THE CULVERT PIPE ENDS AND THE ELEVATION IS 25.46 FLAT, WITHIN THE 1 TENTH TOLERANCE WE ALLOW. I AM APPROVING THIS SURVEY INSPECTION AS NOTED. ________________________________________________________________________________________________________________________________ 1/27/2026 - PREVIOUS INSPECTION NOTES 1/27/26 SPOKE TO DOUG CM ON SITE AND SHOWED HIM THE CULVERT ELEVATIONS ON THE FINAL SURVEY SHOW THE CULVERT PIPE OUT OF TOLERANCE TO THE SWALE PLAN DIAGRAM. PLEASE RECHECK/SHOOT PIPE ELEVATION. ROADSIDE SWALE AND CULVERT SET WITHIN 0.10 Section 300.01 C(3) V-17 3) The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow, nor shall it be sloped more than 0.10 of a foot in thedirection of the drainage flow
ROW FIELD SURVEY /GRADING CERTIFICATION 01/29/2026 APPROVED FSLADISH
Note: 1/29/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. Inspector Notes from Inspection 9463 1/29/26 SURVEY STILL SHOWS CULVERT PIPE OUT OF TOLERANCE TO THE COPC SWALE PLAN DIAGRAM. I WENT OIT AND SHOT THE CULVERT PIPE ENDS AND THE ELEVATION IS 25.46 FLAT, WITHIN THE 1 TENTH TOLERANCE WE ALLOW. I AM APPROVING THIS SURVEY INSPECTION AS NOTED. ________________________________________________________________________________________________________________________________ 1/27/2026 - PREVIOUS INSPECTION NOTES 1/27/26 SPOKE TO DOUG CM ON SITE AND SHOWED HIM THE CULVERT ELEVATIONS ON THE FINAL SURVEY SHOW THE CULVERT PIPE OUT OF TOLERANCE TO THE SWALE PLAN DIAGRAM. PLEASE RECHECK/SHOOT PIPE ELEVATION. ROADSIDE SWALE AND CULVERT SET WITHIN 0.10 Section 300.01 C(3) V-17 3) The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow, nor shall it be sloped more than 0.10 of a foot in thedirection of the drainage flow
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/27/2026 Disapproved - NO FEE FSLADISH
Note: 1/27/26 SPOKE TO DOUG CM ON SITE AND SHOWED HIM THE CULVERT ELEVATIONS ON THE FINAL SURVEY SHOW THE CULVERT PIPE OUT OF TOLERANCE TO THE SWALE PLAN DIAGRAM. PLEASE RECHECK/SHOOT PIPE ELEVATION. ROADSIDE SWALE AND CULVERT SET WITHIN 0.10 Section 300.01 C(3) V-17 3) The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow, nor shall it be sloped more than 0.10 of a foot in thedirection of the drainage flow
ROW- PRE-APRON (PRE-POUR) 01/15/2026 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. 1/14/2026 - PREVIOUS INSPECTION NOTES 1/14/26 THIS SITE IS NOT READY FOR A PREPOUR INSPECTION AT THIS TIME. PHOTO FOR REFERENCE. NOT READY FOR INSPECTION/REINSPECTIONS FEES. Sec. 900.09 F V-67 Sec. 900.09-F Permittee shall be charged an additional fee for each re-inspection required should permittee call for an inspection and NOT be prepared for the requested inspection.
ROW - DRAINAGE 01/15/2026 Disapproved -FEE REQUIRED TPOLACEK
Note: 01-15-26 TPOLACEK*** NO CHANGES TO SITE CONDITIONS. WILL REWTURN TOMORROW FOR FOLLOW UP 1/14/2026 - PREVIOUS INSPECTION NOTES 1/14/26 BUILDER IS REQUIRED TO REPAIR/REPLACE/RESET SILT FENCE. YOU ARE REQUIRED TO MOVE PORTA JOHN ONTO YOUR SITE. SEE PHOTO FOR REFERENCE. SEEING HOW THIS PERMIT HAS HAD SEVERAL PRIOR DRAINGE INSPECTIONS YOU ARE REQUIRED TO MAKE CORRECTIONS IMMEDIATELY. WILL BE BACK FOR COMLIANCE REINSPECTION ON 1/15/26 ________________________________________________________________________________________________________________________________ 10/21/2025 - PREVIOUS INSPECTION NOTES 10/21/25 YOUR CULVERT PIPE IS CRUSHED AND FULL OF DEBRIS. THE SWALE IS FULL OF DEEP RUTS AND IS NOT FLOWING. YOUR SILT FENCE NEEDS REPAIR. YOUR PORTA POTTY IS IN THE COPC ROW. PLEASE MAKE CORRECTIONS. SEE PHOTO FOR REFERENCE. Inspector Notes from Inspection 9470 9/16/25 SPOKE WITH DOUG CM ON 9/15/25 WHO INDICATED HE HAD BEEN OUT OF TOWN ON VACATION THE PREVIOUS WEEK. HE INDICATED HE WAS HEADING TO 5 EDMOND TO MEET UP WITH EARL GRADER TO BRING SITE INTO COMPLIANCE. I TOLD HIM THAT I WOULD HOLD OFF ON MY DRAINAGE INSPECTION UNTIL TODAY 9/16/25 AS A COURTESY. UPON WALKING SITE I HAVE DETERMINED THAT AT THE TIME OF THIS INSPECTION THEY ARE IN COMPLIANCE WITH COPC STANDARDS. I WILL CONTINUE TO MONITOR THIS SITE THROUGHOUT THE CONSTRUTION PROCESS FOR CONTINUED COMPLIANCE. APPROVING AS NOTED. ________________________________________________________________________________________________________________________ 9/12/2025 - PREVIOUS INSPECTION NOTES 9/12/25 NO CHANGES AT THE TIME OF THIS DRAINAGE INSPECTION. A PERMIT INSPECTION HOLD HAS BEEN PLACED ON THIS PERMIT. WILL BE BACK ON 9/15 FOR RECOMPLIANCE INSPECTION AT WHICH TIME A STOP WORK ORDER MAY BE PLACED ON THIS PERMIT. 9/11/2025 - PREVIOUS INSPECTION NOTES 9/11/25 NOTHING HAS CHANGED AT THE TIME OF THIS INSPECTION. PLEASE SEE PREVIOUS INSPECTION NOTES AND UPDATED PHOTO FROM 9/11/25. COMPLIANCE REINSPECTION 9/12/25. 9/9/2025 - PREVIOUS INSPECTION NOTES 1) THE SILT FENCE IS INSTALLED INCORRECTLY ALL SILT FENCE NEED TO BE BURIED 4" SO SOIL NOT GO UNDER SILT FENCE. ALSO THE SILT FENCE IS DOWN ON THE LEFT SIDE OF PROPERTY. 2) FRON LAST NIGHTS RAIN SILT AND SEDIMENT HAS WASHED IN TO DRAINAGE SYSTEM NEED TO CLEAR ALL AREAS SO WATER CAN FLOW CORRECTLY 3) ALL TRASH AND CONSTRCTION DEBRIS NEEDS TO BE PICK UP AND PUT IN DUMPSTER. ------------------------------------------------------------------------------------------ 9/8/2025 - PREVIOUS INSPECTION NOTES YOU STILL NEED TO DO THE FOLLOWING NEED TO INSTALL SILT FENCE ACROSSED THE FRONT OF THE PROPERTY AND INSTALL SILT FENCE ON SITE NOW TO CITY STANDARDS BY TRENCHING SILT FENCE IN AT A MINIMUM 4". ------------------------------------------------------------------------------------------- 9/3/2025 - PREVIOUS INSPECTION NOTES 1) NEED TO INSTALL SILT FENCE ACROSSED THE FRONT OF THE PROPERTY AND INSTALL SILT FENCE ON SITE NOW TO CITY STANDARDS BY TRENCHING SILT FENCE IN AT A MINIMUM 4". 2) NEED TO CLEAN ALL DIRT AND SEDIMENT OUT OF THE ROAD SIDE SWALE AND CREATE A ENTERANCE FOR YOUR SITE WITH A TEMP. CULVERT. YOU WILL HAVE 5 DAY TO CORRECT ALL ISSUE OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT.
ROW - DRAINAGE 01/14/2026 Disapproved -FEE REQUIRED FSLADISH
Note: 1/14/26 BUILDER IS REQUIRED TO REPAIR/REPLACE/RESET SILT FENCE. YOU ARE REQUIRED TO MOVE PORTA JOHN ONTO YOUR SITE. SEE PHOTO FOR REFERENCE. SEEING HOW THIS PERMIT HAS HAD SEVERAL PRIOR DRAINGE INSPECTIONS YOU ARE REQUIRED TO MAKE CORRECTIONS IMMEDIATELY. WILL BE BACK FOR COMLIANCE REINSPECTION ON 1/15/26 ________________________________________________________________________________________________________________________________ 10/21/2025 - PREVIOUS INSPECTION NOTES 10/21/25 YOUR CULVERT PIPE IS CRUSHED AND FULL OF DEBRIS. THE SWALE IS FULL OF DEEP RUTS AND IS NOT FLOWING. YOUR SILT FENCE NEEDS REPAIR. YOUR PORTA POTTY IS IN THE COPC ROW. PLEASE MAKE CORRECTIONS. SEE PHOTO FOR REFERENCE. Inspector Notes from Inspection 9470 9/16/25 SPOKE WITH DOUG CM ON 9/15/25 WHO INDICATED HE HAD BEEN OUT OF TOWN ON VACATION THE PREVIOUS WEEK. HE INDICATED HE WAS HEADING TO 5 EDMOND TO MEET UP WITH EARL GRADER TO BRING SITE INTO COMPLIANCE. I TOLD HIM THAT I WOULD HOLD OFF ON MY DRAINAGE INSPECTION UNTIL TODAY 9/16/25 AS A COURTESY. UPON WALKING SITE I HAVE DETERMINED THAT AT THE TIME OF THIS INSPECTION THEY ARE IN COMPLIANCE WITH COPC STANDARDS. I WILL CONTINUE TO MONITOR THIS SITE THROUGHOUT THE CONSTRUTION PROCESS FOR CONTINUED COMPLIANCE. APPROVING AS NOTED. ________________________________________________________________________________________________________________________ 9/12/2025 - PREVIOUS INSPECTION NOTES 9/12/25 NO CHANGES AT THE TIME OF THIS DRAINAGE INSPECTION. A PERMIT INSPECTION HOLD HAS BEEN PLACED ON THIS PERMIT. WILL BE BACK ON 9/15 FOR RECOMPLIANCE INSPECTION AT WHICH TIME A STOP WORK ORDER MAY BE PLACED ON THIS PERMIT. 9/11/2025 - PREVIOUS INSPECTION NOTES 9/11/25 NOTHING HAS CHANGED AT THE TIME OF THIS INSPECTION. PLEASE SEE PREVIOUS INSPECTION NOTES AND UPDATED PHOTO FROM 9/11/25. COMPLIANCE REINSPECTION 9/12/25. 9/9/2025 - PREVIOUS INSPECTION NOTES 1) THE SILT FENCE IS INSTALLED INCORRECTLY ALL SILT FENCE NEED TO BE BURIED 4" SO SOIL NOT GO UNDER SILT FENCE. ALSO THE SILT FENCE IS DOWN ON THE LEFT SIDE OF PROPERTY. 2) FRON LAST NIGHTS RAIN SILT AND SEDIMENT HAS WASHED IN TO DRAINAGE SYSTEM NEED TO CLEAR ALL AREAS SO WATER CAN FLOW CORRECTLY 3) ALL TRASH AND CONSTRCTION DEBRIS NEEDS TO BE PICK UP AND PUT IN DUMPSTER. ------------------------------------------------------------------------------------------ 9/8/2025 - PREVIOUS INSPECTION NOTES YOU STILL NEED TO DO THE FOLLOWING NEED TO INSTALL SILT FENCE ACROSSED THE FRONT OF THE PROPERTY AND INSTALL SILT FENCE ON SITE NOW TO CITY STANDARDS BY TRENCHING SILT FENCE IN AT A MINIMUM 4". ------------------------------------------------------------------------------------------- 9/3/2025 - PREVIOUS INSPECTION NOTES 1) NEED TO INSTALL SILT FENCE ACROSSED THE FRONT OF THE PROPERTY AND INSTALL SILT FENCE ON SITE NOW TO CITY STANDARDS BY TRENCHING SILT FENCE IN AT A MINIMUM 4". 2) NEED TO CLEAN ALL DIRT AND SEDIMENT OUT OF THE ROAD SIDE SWALE AND CREATE A ENTERANCE FOR YOUR SITE WITH A TEMP. CULVERT. YOU WILL HAVE 5 DAY TO CORRECT ALL ISSUE OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT.
ROW- PRE-APRON (PRE-POUR) 01/14/2026 Disapproved -FEE REQUIRED FSLADISH
Note: 1/14/26 THIS SITE IS NOT READY FOR A PREPOUR INSPECTION AT THIS TIME. PHOTO FOR REFERENCE. NOT READY FOR INSPECTION/REINSPECTIONS FEES. Sec. 900.09 F V-67 Sec. 900.09-F Permittee shall be charged an additional fee for each re-inspection required should permittee call for an inspection and NOT be prepared for the requested inspection.
GRAVITY SEWER TEST 01/12/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 1/12/2026 8:33:00 AM *** 1/9/2026 - PREVIOUS INSPECTION NOTES 1/9/26: NO CHANGE FROM PREVIOUS INSPECTION. 1/7/2026 - PREVIOUS INSPECTION NOTES 1/7/25: 1). Drain pipe needs to be exposed to check pitch. (FPC - Table 704.1) / (FRBC - table P3105.1) 2). First cleanout pipe needs to be filled to the top (at a minimum) for inspection. P2503.4 Building sewer testing. 1/6/2026 - PREVIOUS INSPECTION NOTES 1/6/26 1. No head pressure test on sewer line 10/20/25 SPOKE WITH PLUMBER NOT EVEN SECOND ROUGH HAS BEEN COMPLETED YET, PEP TANK REQUEST NOT APPROVED WATER SERVICE NOT RAN YET
SEWER TIE IN 01/12/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 1/12/2026 8:32:45 AM *** 1/9/2026 - PREVIOUS INSPECTION NOTES 1/9/26: NO CHANGE FROM PREVIOUS INSPECTION. 1). Drain pipe needs to be exposed to check pitch. (FPC - Table 704.1) / (FRBC - table P3105.1) (and connection to Pep Tank as stated previously). 2). First cleanout pipe needs to be filled to the top (at a minimum) for inspection. P2503.4 Building sewer testing. 1/7/2026 - PREVIOUS INSPECTION NOTES 1/7/26: 1). Drain pipe needs to be exposed to check pitch. (FPC - Table 704.1) / (FRBC - table P3105.1) 2). First cleanout pipe needs to be filled to the top (at a minimum) for inspection. P2503.4 Building sewer testing. 1/6/2026 - PREVIOUS INSPECTION NOTES 1/6/26 1. Cant see connection to pep tank
GRAVITY SEWER TEST 01/09/2026 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 1/9/2026 1:16:25 PM *** 1/9/26: NO CHANGE FROM PREVIOUS INSPECTION. 1/7/2026 - PREVIOUS INSPECTION NOTES 1/7/25: 1). Drain pipe needs to be exposed to check pitch. (FPC - Table 704.1) / (FRBC - table P3105.1) 2). First cleanout pipe needs to be filled to the top (at a minimum) for inspection. P2503.4 Building sewer testing. 1/6/2026 - PREVIOUS INSPECTION NOTES 1/6/26 1. No head pressure test on sewer line 10/20/25 SPOKE WITH PLUMBER NOT EVEN SECOND ROUGH HAS BEEN COMPLETED YET, PEP TANK REQUEST NOT APPROVED WATER SERVICE NOT RAN YET
SEWER TIE IN 01/09/2026 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 1/9/2026 1:18:05 PM *** 1/9/26: NO CHANGE FROM PREVIOUS INSPECTION. 1). Drain pipe needs to be exposed to check pitch. (FPC - Table 704.1) / (FRBC - table P3105.1) (and connection to Pep Tank as stated previously). 2). First cleanout pipe needs to be filled to the top (at a minimum) for inspection. P2503.4 Building sewer testing. 1/7/2026 - PREVIOUS INSPECTION NOTES 1/7/26: 1). Drain pipe needs to be exposed to check pitch. (FPC - Table 704.1) / (FRBC - table P3105.1) 2). First cleanout pipe needs to be filled to the top (at a minimum) for inspection. P2503.4 Building sewer testing. 1/6/2026 - PREVIOUS INSPECTION NOTES 1/6/26 1. Cant see connection to pep tank
SEWER TIE IN 01/07/2026 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 1/7/2026 1:29:19 PM *** 1/7/26: 1). Drain pipe needs to be exposed to check pitch. (FPC - Table 704.1) / (FRBC - table P3105.1) 2). First cleanout pipe needs to be filled to the top (at a minimum) for inspection. P2503.4 Building sewer testing. 1/6/2026 - PREVIOUS INSPECTION NOTES 1/6/26 1. Cant see connection to pep tank
GRAVITY SEWER TEST 01/07/2026 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 1/7/2026 1:28:08 PM *** 1/7/25: 1). Drain pipe needs to be exposed to check pitch. (FPC - Table 704.1) / (FRBC - table P3105.1) 2). First cleanout pipe needs to be filled to the top (at a minimum) for inspection. P2503.4 Building sewer testing. 1/6/2026 - PREVIOUS INSPECTION NOTES 1/6/26 1. No head pressure test on sewer line 10/20/25 SPOKE WITH PLUMBER NOT EVEN SECOND ROUGH HAS BEEN COMPLETED YET, PEP TANK REQUEST NOT APPROVED WATER SERVICE NOT RAN YET
GRAVITY SEWER TEST 01/06/2026 Disapproved - NO FEE MKRASKI
Note: 1/6/26 1. No head pressure test on sewer line 10/20/25 SPOKE WITH PLUMBER NOT EVEN SECOND ROUGH HAS BEEN COMPLETED YET, PEP TANK REQUEST NOT APPROVED WATER SERVICE NOT RAN YET
SEWER TIE IN 01/06/2026 Disapproved - NO FEE MKRASKI
Note: 1/6/26 1. Cant see connection to pep tank
U-CROSS CONNECTION 01/06/2026 APPROVED - AS NOTED BHAINES
Note: No CC, No IRR
ELECTRIC - EARLY POWER 12/22/2025 APPROVED CVANSTRAHLEN
PEP TANK INSTALLATION REQUEST 12/09/2025 APPROVED CBOWERMASTER
INSULATION 11/14/2025 APPROVED - AS NOTED MCONTRYMAN
Note: 11/14/25 Energy calcs show a 6" range vent being installed and going through the roof. Please revise, and have approved, energy calcs, if omitting this vent by final Inspector Notes from Inspection 2320 Ecalcs were not approved at time of this inspection. Check HVAC layout on insulation. Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 11/7/2025 2:26:09 PM *** 11/7/25: APPROVED AS NOTED. 1). Installed ductwork does not match the Duct layout shown on the Energy Calcs. Revision required. FBC [A]107.4 NOTE: TEMPORARY CULVERT PIPE HAS BEEN REMOVED HOWEVER SWALE HAS BEEN CONDITIONED TO ALLOW FREE FLOW OF WATER THROUGH THE SWALE. SWALE WILL NEED TO TO BE MAINTAINED TO REMAIN IN IT'S CURRENT CONDITION THROUGHOUT THE BUILD PROCESS UNTIL FINAL GRADE IS COMPLETED. Inspector Notes from Inspection 2460 11/5/25 1. Clean all truss's of debris per manufacturer spec 2. Silt needs repair. FBC 3307.1 3. Temporary culvert needs to be replaced to allow for free flow of water through the swale. FBC 3303.5 Make all repairs before next inspection
LATH/BRICK/ WATER BARRIER 11/12/2025 APPROVED - AS NOTED PKNAPIK
Note: Ecalcs were not approved at time of this inspection. Check HVAC layout on insulation. Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 11/7/2025 2:26:09 PM *** 11/7/25: APPROVED AS NOTED. 1). Installed ductwork does not match the Duct layout shown on the Energy Calcs. Revision required. FBC [A]107.4 NOTE: TEMPORARY CULVERT PIPE HAS BEEN REMOVED HOWEVER SWALE HAS BEEN CONDITIONED TO ALLOW FREE FLOW OF WATER THROUGH THE SWALE. SWALE WILL NEED TO TO BE MAINTAINED TO REMAIN IN IT'S CURRENT CONDITION THROUGHOUT THE BUILD PROCESS UNTIL FINAL GRADE IS COMPLETED. Inspector Notes from Inspection 2460 11/5/25 1. Clean all truss's of debris per manufacturer spec 2. Silt needs repair. FBC 3307.1 3. Temporary culvert needs to be replaced to allow for free flow of water through the swale. FBC 3303.5 Make all repairs before next inspection
ALL ROUGH 11/07/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 11/7/2025 2:26:09 PM *** 11/7/25: APPROVED AS NOTED. 1). Installed ductwork does not match the Duct layout shown on the Energy Calcs. Revision required. FBC [A]107.4 NOTE: TEMPORARY CULVERT PIPE HAS BEEN REMOVED HOWEVER SWALE HAS BEEN CONDITIONED TO ALLOW FREE FLOW OF WATER THROUGH THE SWALE. SWALE WILL NEED TO TO BE MAINTAINED TO REMAIN IN IT'S CURRENT CONDITION THROUGHOUT THE BUILD PROCESS UNTIL FINAL GRADE IS COMPLETED. Inspector Notes from Inspection 2460 11/5/25 1. Clean all truss's of debris per manufacturer spec 2. Silt needs repair. FBC 3307.1 3. Temporary culvert needs to be replaced to allow for free flow of water through the swale. FBC 3303.5 Make all repairs before next inspection
WALL SHEATHING 11/05/2025 APPROVED - AS NOTED MKRASKI
Note: 11/5/25 1). Silt fence needs to be repaired and maintained.FBC 3307.1 2). Temporary culvert pipe needs to be repaired and swale corrected to allow free flow of water through the swale. FBC 3303.5 Make BOTH repairs before next inspection to avoid fees
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/05/2025 APPROVED - AS NOTED MKRASKI
Note: 11/5/25 1. Clean all truss's of debris per manufacturer spec 2. Silt needs repair. FBC 3307.1 3. Temporary culvert needs to be replaced to allow for free flow of water through the swale. FBC 3303.5 Make all repairs before next inspection
WALL SHEATHING 10/29/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 10/29/2025 8:34:26 AM *** ALSO PORTABLE TOILET NEEDS TO BE MOVED OUT OF THE SWALE AND ONTO SITE PROPERTY TO ALLOW FREE FLOW OF WATWER THROUGH THE SWALE. FBC 3303.5 *** NOTES ADDED BY RSIMS 10/29/2025 8:31:01 AM *** Inspector Notes from Inspection 2467 *** NOTES ADDED BY RSIMS 10/20/2025 11:12:54 AM *** 10/28/25: PREVIOUS NOTES NOT RESOLVED AS REQUIRED. 10/20/25: Approved as noted. All corrections need to be complete prior any additional inspections being completed/approved. 1). Silt fence needs to be repaired and maintained.FBC 3307.1 2). Temporary culvert pipe needs to be repaired and swale corrected to allow free flow of water through the swale. FBC 3303.5
ROW - DRAINAGE 10/21/2025 Disapproved -FEE REQUIRED FSLADISH
Note: 10/21/25 YOUR CULVERT PIPE IS CRUSHED AND FULL OF DEBRIS. THE SWALE IS FULL OF DEEP RUTS AND IS NOT FLOWING. YOUR SILT FENCE NEEDS REPAIR. YOUR PORTA POTTY IS IN THE COPC ROW. PLEASE MAKE CORRECTIONS. SEE PHOTO FOR REFERENCE. Inspector Notes from Inspection 9470 9/16/25 SPOKE WITH DOUG CM ON 9/15/25 WHO INDICATED HE HAD BEEN OUT OF TOWN ON VACATION THE PREVIOUS WEEK. HE INDICATED HE WAS HEADING TO 5 EDMOND TO MEET UP WITH EARL GRADER TO BRING SITE INTO COMPLIANCE. I TOLD HIM THAT I WOULD HOLD OFF ON MY DRAINAGE INSPECTION UNTIL TODAY 9/16/25 AS A COURTESY. UPON WALKING SITE I HAVE DETERMINED THAT AT THE TIME OF THIS INSPECTION THEY ARE IN COMPLIANCE WITH COPC STANDARDS. I WILL CONTINUE TO MONITOR THIS SITE THROUGHOUT THE CONSTRUTION PROCESS FOR CONTINUED COMPLIANCE. APPROVING AS NOTED. ________________________________________________________________________________________________________________________ 9/12/2025 - PREVIOUS INSPECTION NOTES 9/12/25 NO CHANGES AT THE TIME OF THIS DRAINAGE INSPECTION. A PERMIT INSPECTION HOLD HAS BEEN PLACED ON THIS PERMIT. WILL BE BACK ON 9/15 FOR RECOMPLIANCE INSPECTION AT WHICH TIME A STOP WORK ORDER MAY BE PLACED ON THIS PERMIT. 9/11/2025 - PREVIOUS INSPECTION NOTES 9/11/25 NOTHING HAS CHANGED AT THE TIME OF THIS INSPECTION. PLEASE SEE PREVIOUS INSPECTION NOTES AND UPDATED PHOTO FROM 9/11/25. COMPLIANCE REINSPECTION 9/12/25. 9/9/2025 - PREVIOUS INSPECTION NOTES 1) THE SILT FENCE IS INSTALLED INCORRECTLY ALL SILT FENCE NEED TO BE BURIED 4" SO SOIL NOT GO UNDER SILT FENCE. ALSO THE SILT FENCE IS DOWN ON THE LEFT SIDE OF PROPERTY. 2) FRON LAST NIGHTS RAIN SILT AND SEDIMENT HAS WASHED IN TO DRAINAGE SYSTEM NEED TO CLEAR ALL AREAS SO WATER CAN FLOW CORRECTLY 3) ALL TRASH AND CONSTRCTION DEBRIS NEEDS TO BE PICK UP AND PUT IN DUMPSTER. ------------------------------------------------------------------------------------------ 9/8/2025 - PREVIOUS INSPECTION NOTES YOU STILL NEED TO DO THE FOLLOWING NEED TO INSTALL SILT FENCE ACROSSED THE FRONT OF THE PROPERTY AND INSTALL SILT FENCE ON SITE NOW TO CITY STANDARDS BY TRENCHING SILT FENCE IN AT A MINIMUM 4". ------------------------------------------------------------------------------------------- 9/3/2025 - PREVIOUS INSPECTION NOTES 1) NEED TO INSTALL SILT FENCE ACROSSED THE FRONT OF THE PROPERTY AND INSTALL SILT FENCE ON SITE NOW TO CITY STANDARDS BY TRENCHING SILT FENCE IN AT A MINIMUM 4". 2) NEED TO CLEAN ALL DIRT AND SEDIMENT OUT OF THE ROAD SIDE SWALE AND CREATE A ENTERANCE FOR YOUR SITE WITH A TEMP. CULVERT. YOU WILL HAVE 5 DAY TO CORRECT ALL ISSUE OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT.
ROOF SHEATHING 10/20/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 10/20/2025 11:09:59 AM *** 10/20/25: This inspection added to check Roof Sheathing that was unable to be inspected during the first 2460 (RS/B/T/DC) inspection. Roof sheathing bump checked and approved.
ROOF VALLEY & METAL 10/20/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 10/20/2025 11:12:54 AM *** 10/20/25: Approved as noted. All corrections need to be complete prior any additional inspections being completed/approved. 1). Silt fence needs to be repaired and maintained.FBC 3307.1 2). Temporary culvert pipe needs to be repaired and swale corrected to allow free flow of water through the swale. FBC 3303.5
GRAVITY SEWER TEST 10/20/2025 Disapproved - NO FEE MGIBSON
Note: Inspector Notes from Inspection 2060 SPOKE WITH PLUMBER NOT EVEN SECOND ROUGH HAS BEEN COMPLETED YET, PEP TANK REQUEST NOT APPROVED WATER SERVICE NOT RAN YET
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/17/2025 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 10/17/2025 10:47:54 AM *** 10/17/25: 1). Could not bump check roof sheathing due to contractors on roof installing underlayment. FBC[A]-110.1 2). Truss A10 first in the series has a broken web that requires MiTek repair. FBC [A]107.4 3). Truss packet has two A9 pages that show different bracing/engineering requirements. Revision required. FBC [A]107.4 4). Silt needs repair. FBC 3307.1 5). Swale needs to be cleared and a temporary culvert pipe installed to allow for free flow of water through the swale. FBC 3303.5
TIE BEAM / LINTEL 10/09/2025 APPROVED CVANSTRAHLEN
Note: 10/3/2025 - PREVIOUS INSPECTION NOTES 10-3-25 1. All drills are too shallow. 2. All drills pulled out.
TIE BEAM / LINTEL 10/06/2025 Disapproved - NO FEE CVANSTRAHLEN
Note: Please fix items before next inspection #1- fix 1 on the right side and 1 on the back rebars too shallow #2- lumber is been delivery and place in the swale , please clear up the swale 10/3/2025 - PREVIOUS INSPECTION NOTES 10-3-25 1. All drills are too shallow. 2. All drills pulled out.
TIE BEAM / LINTEL 10/03/2025 Disapproved -FEE REQUIRED BTAYLOR
Note: 10-3-25 1. All drills are too shallow. 2. All drills pulled out.
WATER METER INSTALLATION REQUEST 10/01/2025 APPROVED CBOWERMASTER
MONOLITHIC SLAB 09/24/2025 APPROVED MCONTRYMAN
Note: New inspection due to canceled inspection 9/17/2025 - PREVIOUS INSPECTION NOTES 9-17-25 1. Footers have cave in's along left side of the house and back right corner. 2. Shower on left side of house needs rebar wrapped around the shower form. All are circled on plans.
MONOLITHIC SLAB 09/19/2025 CANCELLED BY APPLICANT WEB
Note: 9/17/2025 - PREVIOUS INSPECTION NOTES 9-17-25 1. Footers have cave in's along left side of the house and back right corner. 2. Shower on left side of house needs rebar wrapped around the shower form. All are circled on plans.
MONOLITHIC SLAB 09/17/2025 Disapproved - NO FEE BTAYLOR
Note: 9-17-25 1. Footers have cave in's along left side of the house and back right corner. 2. Shower on left side of house needs rebar wrapped around the shower form. All are circled on plans.
FORMBOARD SURVEY (OFFICE USE ONLY) 09/17/2025 APPROVED RRICKS
ROW - DRAINAGE 09/15/2025 APPROVED - AS NOTED FSLADISH
Note: 9/16/25 SPOKE WITH DOUG CM ON 9/15/25 WHO INDICATED HE HAD BEEN OUT OF TOWN ON VACATION THE PREVIOUS WEEK. HE INDICATED HE WAS HEADING TO 5 EDMOND TO MEET UP WITH EARL GRADER TO BRING SITE INTO COMPLIANCE. I TOLD HIM THAT I WOULD HOLD OFF ON MY DRAINAGE INSPECTION UNTIL TODAY 9/16/25 AS A COURTESY. UPON WALKING SITE I HAVE DETERMINED THAT AT THE TIME OF THIS INSPECTION THEY ARE IN COMPLIANCE WITH COPC STANDARDS. I WILL CONTINUE TO MONITOR THIS SITE THROUGHOUT THE CONSTRUTION PROCESS FOR CONTINUED COMPLIANCE. APPROVING AS NOTED. ________________________________________________________________________________________________________________________ 9/12/2025 - PREVIOUS INSPECTION NOTES 9/12/25 NO CHANGES AT THE TIME OF THIS DRAINAGE INSPECTION. A PERMIT INSPECTION HOLD HAS BEEN PLACED ON THIS PERMIT. WILL BE BACK ON 9/15 FOR RECOMPLIANCE INSPECTION AT WHICH TIME A STOP WORK ORDER MAY BE PLACED ON THIS PERMIT. 9/11/2025 - PREVIOUS INSPECTION NOTES 9/11/25 NOTHING HAS CHANGED AT THE TIME OF THIS INSPECTION. PLEASE SEE PREVIOUS INSPECTION NOTES AND UPDATED PHOTO FROM 9/11/25. COMPLIANCE REINSPECTION 9/12/25. 9/9/2025 - PREVIOUS INSPECTION NOTES 1) THE SILT FENCE IS INSTALLED INCORRECTLY ALL SILT FENCE NEED TO BE BURIED 4" SO SOIL NOT GO UNDER SILT FENCE. ALSO THE SILT FENCE IS DOWN ON THE LEFT SIDE OF PROPERTY. 2) FRON LAST NIGHTS RAIN SILT AND SEDIMENT HAS WASHED IN TO DRAINAGE SYSTEM NEED TO CLEAR ALL AREAS SO WATER CAN FLOW CORRECTLY 3) ALL TRASH AND CONSTRCTION DEBRIS NEEDS TO BE PICK UP AND PUT IN DUMPSTER. ------------------------------------------------------------------------------------------ 9/8/2025 - PREVIOUS INSPECTION NOTES YOU STILL NEED TO DO THE FOLLOWING NEED TO INSTALL SILT FENCE ACROSSED THE FRONT OF THE PROPERTY AND INSTALL SILT FENCE ON SITE NOW TO CITY STANDARDS BY TRENCHING SILT FENCE IN AT A MINIMUM 4". ------------------------------------------------------------------------------------------- 9/3/2025 - PREVIOUS INSPECTION NOTES 1) NEED TO INSTALL SILT FENCE ACROSSED THE FRONT OF THE PROPERTY AND INSTALL SILT FENCE ON SITE NOW TO CITY STANDARDS BY TRENCHING SILT FENCE IN AT A MINIMUM 4". 2) NEED TO CLEAN ALL DIRT AND SEDIMENT OUT OF THE ROAD SIDE SWALE AND CREATE A ENTERANCE FOR YOUR SITE WITH A TEMP. CULVERT. YOU WILL HAVE 5 DAY TO CORRECT ALL ISSUE OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT.
ROW - DRAINAGE 09/12/2025 Disapproved -FEE REQUIRED FSLADISH
Note: 9/12/25 NO CHANGES AT THE TIME OF THIS DRAINAGE INSPECTION. A PERMIT INSPECTION HOLD HAS BEEN PLACED ON THIS PERMIT. WILL BE BACK ON 9/15 FOR RECOMPLIANCE INSPECTION AT WHICH TIME A STOP WORK ORDER MAY BE PLACED ON THIS PERMIT. 9/11/2025 - PREVIOUS INSPECTION NOTES 9/11/25 NOTHING HAS CHANGED AT THE TIME OF THIS INSPECTION. PLEASE SEE PREVIOUS INSPECTION NOTES AND UPDATED PHOTO FROM 9/11/25. COMPLIANCE REINSPECTION 9/12/25. 9/9/2025 - PREVIOUS INSPECTION NOTES 1) THE SILT FENCE IS INSTALLED INCORRECTLY ALL SILT FENCE NEED TO BE BURIED 4" SO SOIL NOT GO UNDER SILT FENCE. ALSO THE SILT FENCE IS DOWN ON THE LEFT SIDE OF PROPERTY. 2) FRON LAST NIGHTS RAIN SILT AND SEDIMENT HAS WASHED IN TO DRAINAGE SYSTEM NEED TO CLEAR ALL AREAS SO WATER CAN FLOW CORRECTLY 3) ALL TRASH AND CONSTRCTION DEBRIS NEEDS TO BE PICK UP AND PUT IN DUMPSTER. ------------------------------------------------------------------------------------------ 9/8/2025 - PREVIOUS INSPECTION NOTES YOU STILL NEED TO DO THE FOLLOWING NEED TO INSTALL SILT FENCE ACROSSED THE FRONT OF THE PROPERTY AND INSTALL SILT FENCE ON SITE NOW TO CITY STANDARDS BY TRENCHING SILT FENCE IN AT A MINIMUM 4". ------------------------------------------------------------------------------------------- 9/3/2025 - PREVIOUS INSPECTION NOTES 1) NEED TO INSTALL SILT FENCE ACROSSED THE FRONT OF THE PROPERTY AND INSTALL SILT FENCE ON SITE NOW TO CITY STANDARDS BY TRENCHING SILT FENCE IN AT A MINIMUM 4". 2) NEED TO CLEAN ALL DIRT AND SEDIMENT OUT OF THE ROAD SIDE SWALE AND CREATE A ENTERANCE FOR YOUR SITE WITH A TEMP. CULVERT. YOU WILL HAVE 5 DAY TO CORRECT ALL ISSUE OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT.
ROW - DRAINAGE 09/10/2025 Disapproved -FEE REQUIRED FSLADISH
Note: 9/11/25 NOTHING HAS CHANGED AT THE TIME OF THIS INSPECTION. PLEASE SEE PREVIOUS INSPECTION NOTES AND UPDATED PHOTO FROM 9/11/25. COMPLIANCE REINSPECTION 9/12/25. 9/9/2025 - PREVIOUS INSPECTION NOTES 1) THE SILT FENCE IS INSTALLED INCORRECTLY ALL SILT FENCE NEED TO BE BURIED 4" SO SOIL NOT GO UNDER SILT FENCE. ALSO THE SILT FENCE IS DOWN ON THE LEFT SIDE OF PROPERTY. 2) FRON LAST NIGHTS RAIN SILT AND SEDIMENT HAS WASHED IN TO DRAINAGE SYSTEM NEED TO CLEAR ALL AREAS SO WATER CAN FLOW CORRECTLY 3) ALL TRASH AND CONSTRCTION DEBRIS NEEDS TO BE PICK UP AND PUT IN DUMPSTER. ------------------------------------------------------------------------------------------ 9/8/2025 - PREVIOUS INSPECTION NOTES YOU STILL NEED TO DO THE FOLLOWING NEED TO INSTALL SILT FENCE ACROSSED THE FRONT OF THE PROPERTY AND INSTALL SILT FENCE ON SITE NOW TO CITY STANDARDS BY TRENCHING SILT FENCE IN AT A MINIMUM 4". ------------------------------------------------------------------------------------------- 9/3/2025 - PREVIOUS INSPECTION NOTES 1) NEED TO INSTALL SILT FENCE ACROSSED THE FRONT OF THE PROPERTY AND INSTALL SILT FENCE ON SITE NOW TO CITY STANDARDS BY TRENCHING SILT FENCE IN AT A MINIMUM 4". 2) NEED TO CLEAN ALL DIRT AND SEDIMENT OUT OF THE ROAD SIDE SWALE AND CREATE A ENTERANCE FOR YOUR SITE WITH A TEMP. CULVERT. YOU WILL HAVE 5 DAY TO CORRECT ALL ISSUE OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT.
ROW - DRAINAGE 09/09/2025 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) THE SILT FENCE IS INSTALLED INCORRECTLY ALL SILT FENCE NEED TO BE BURIED 4" SO SOIL NOT GO UNDER SILT FENCE. ALSO THE SILT FENCE IS DOWN ON THE LEFT SIDE OF PROPERTY. 2) FRON LAST NIGHTS RAIN SILT AND SEDIMENT HAS WASHED IN TO DRAINAGE SYSTEM NEED TO CLEAR ALL AREAS SO WATER CAN FLOW CORRECTLY 3) ALL TRASH AND CONSTRCTION DEBRIS NEEDS TO BE PICK UP AND PUT IN DUMPSTER. ------------------------------------------------------------------------------------------ 9/8/2025 - PREVIOUS INSPECTION NOTES YOU STILL NEED TO DO THE FOLLOWING NEED TO INSTALL SILT FENCE ACROSSED THE FRONT OF THE PROPERTY AND INSTALL SILT FENCE ON SITE NOW TO CITY STANDARDS BY TRENCHING SILT FENCE IN AT A MINIMUM 4". ------------------------------------------------------------------------------------------- 9/3/2025 - PREVIOUS INSPECTION NOTES 1) NEED TO INSTALL SILT FENCE ACROSSED THE FRONT OF THE PROPERTY AND INSTALL SILT FENCE ON SITE NOW TO CITY STANDARDS BY TRENCHING SILT FENCE IN AT A MINIMUM 4". 2) NEED TO CLEAN ALL DIRT AND SEDIMENT OUT OF THE ROAD SIDE SWALE AND CREATE A ENTERANCE FOR YOUR SITE WITH A TEMP. CULVERT. YOU WILL HAVE 5 DAY TO CORRECT ALL ISSUE OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT.
PLUMBING 1ST ROUGH UNDERGROUND 09/09/2025 APPROVED - AS NOTED MGIBSON
Note: WATER SERVICE NOT RAN YET
ROW - DRAINAGE 09/08/2025 Disapproved -FEE REQUIRED PFLANAGAN
Note: YOU STILL NEED TO DO THE FOLLOWING NEED TO INSTALL SILT FENCE ACROSSED THE FRONT OF THE PROPERTY AND INSTALL SILT FENCE ON SITE NOW TO CITY STANDARDS BY TRENCHING SILT FENCE IN AT A MINIMUM 4". ------------------------------------------------------------------------------------------- 9/3/2025 - PREVIOUS INSPECTION NOTES 1) NEED TO INSTALL SILT FENCE ACROSSED THE FRONT OF THE PROPERTY AND INSTALL SILT FENCE ON SITE NOW TO CITY STANDARDS BY TRENCHING SILT FENCE IN AT A MINIMUM 4". 2) NEED TO CLEAN ALL DIRT AND SEDIMENT OUT OF THE ROAD SIDE SWALE AND CREATE A ENTERANCE FOR YOUR SITE WITH A TEMP. CULVERT. YOU WILL HAVE 5 DAY TO CORRECT ALL ISSUE OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT.
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 09/04/2025 APPROVED PKNAPIK
ROW- PROJECT STATUS 09/03/2025 Status Check PFLANAGAN
Note: MET WITH RESIDENT ABOUT FFE AND FILL ON THE LOT. TOLD HIM THAT THE SITE PLAN SHOWED THAT THE FFE IS .55 HIGHER THEN HIS AND THAT WE WILL NOT KNOW TILL FORM BOARD SURVEY TO SEE IF FORMS ARE UP TO CITY TECH. MANUAL STANDARDS. ------------------------------------------------------------------------------------------------- resident at 7 edmond pl states that house is to high please reach out to talk with resident.
ROW - DRAINAGE 09/03/2025 Disapproved - NO FEE PFLANAGAN
Note: 1) NEED TO INSTALL SILT FENCE ACROSSED THE FRONT OF THE PROPERTY AND INSTALL SILT FENCE ON SITE NOW TO CITY STANDARDS BY TRENCHING SILT FENCE IN AT A MINIMUM 4". 2) NEED TO CLEAN ALL DIRT AND SEDIMENT OUT OF THE ROAD SIDE SWALE AND CREATE A ENTERANCE FOR YOUR SITE WITH A TEMP. CULVERT. YOU WILL HAVE 5 DAY TO CORRECT ALL ISSUE OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT.

Review History

Department Status Date In Date Out
MECH COMPLETE 11/12/2025 11/12/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 10/23/2025 10/27/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SW1 COMPLETE 09/17/2025 09/17/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM ROW issues resolved.
SW1 HOLD 09/08/2025 09/08/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Formboard Survey approved but cannot be released until ROW- Drainage issues are resolved. Once drainage correctiosn are made and approved please email or call me so the formboard survey can be released.
SW1 COMPLETE 09/05/2025 09/08/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 09/05/2025 09/05/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 09/04/2025 09/04/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 08/11/2025 08/12/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SW1 COMPLETE 05/29/2025 06/02/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 05/29/2025 05/30/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ZON COMPLETE 05/29/2025 05/29/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SW1 HOLD 05/20/2025 05/28/2025
Note: Held By: RODNEY RICKS - (386)986-2001 - RRICKS@PALMCOASTGOV.COM Repeat comment: Please depeict the drainage swale on the left closer to the 5' easement. As of now the 4:1 slope is being exceed and does not meet COPC standards.
ENGIN1 COMPLETE 05/20/2025 05/20/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ZON COMPLETE 05/20/2025 05/20/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SW1 HOLD 05/13/2025 05/16/2025
Note: Held By: RODNEY RICKS - (386)986-2001 - RRICKS@PALMCOASTGOV.COM There shall be 6" of fall in first 10' of the home. Front right doesn't have a 6" fall and is depicted flat. Please indicated where the swale centerline is on the left side to ensure the 4:1 slope is not exceeded. There most be a minimum of 0.1' fall every 20'. On the right property line towards the front there is a flat spot going to the front yard swale. Please fee free to call if there are any questions or concerns.
ENGIN1 COMPLETE 05/13/2025 05/13/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ZON COMPLETE 05/13/2025 05/13/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SW1 HOLD 05/02/2025 05/08/2025
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM THE DRAINAGE ON THE RIGHT YOU NEED TO HAVE .30 FROM THE DRIANAGE PATTERN TO THE 10' OFF ELEVATIONS SO WATER WILL NOT IMPACT THE LOT TO THE RIGHT.
ZON COMPLETE 05/02/2025 05/02/2025
Note: Released By: NICOLE DIMATTINA - - NDIMATTINA@PALMCOASTGOV.COM NO ZONING CHANGES
ENGIN1 COMPLETE 05/02/2025 05/02/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
SWALE COMPLETE 04/22/2025 05/08/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
BADMIN COMPLETE 04/21/2025 04/25/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 04/21/2025 04/25/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 04/21/2025 04/30/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 04/21/2025 04/25/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/21/2025 04/22/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 04/21/2025 04/24/2025
LOCATE COMPLETE 04/21/2025 04/29/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 04/21/2025 04/24/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 04/21/2025 04/28/2025
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM PLEASE REVISE DRAINAGE PLAN TO MATCH THE ADJACENT LOTS DRAINAGE AS A "B" DRAINAGE. WHERE THE DRIANAGE SPLITS WHERE SOME GOES TO THE FRONT AND SOME GOES TO BACK.
ZON COMPLETE 04/21/2025 04/23/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 01/30/2026
REINSPECTION RESIDENTIAL ¤40.00 01/30/2026
REINSPECTION RESIDENTIAL ¤40.00 01/30/2026
REINSPECTION RESIDENTIAL ¤40.00 01/30/2026
REINSPECTION RESIDENTIAL ¤40.00 01/30/2026
REINSPECTION FEE ¤40.00 01/30/2026
REINSPECTION FEE ¤40.00 01/30/2026
RSI REINSPECTION 1 ¤35.00 01/30/2026
RSI REINSPECTION 1 ¤35.00 01/30/2026
RSI REINSPECTION 1 ¤35.00 01/30/2026
RSI REINSPECTION 1 ¤35.00 01/30/2026
RSI REINSPECTION 1 ¤35.00 01/30/2026
SW ENG - INSPECTION 20 ¤20.00 01/30/2026
SW ENG - INSPECTION 20 ¤20.00 01/30/2026
SW ENG - INSPECTION 20 ¤20.00 01/30/2026
SW ENG - INSPECTION 20 ¤20.00 01/30/2026
SW ENG - INSPECTION 20 ¤20.00 01/30/2026
SW ENG - INSPECTION 20 ¤20.00 01/30/2026
SW ENG INSPECTION 80 ¤80.00 06/02/2025
SW ENG PRE APRON ¤30.00 06/02/2025
SW ENG - REVIEW 20 ¤20.00 06/02/2025
SW ENG RES REVIEW 200 ¤200.00 06/02/2025
ADJUSTMENT 10% (¤158.67) 06/02/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 06/02/2025
INSPECTION - RESIDENTIAL ¤1,212.75 06/02/2025
PLAN REVIEW - RESIDENTIAL ¤343.98 06/02/2025
WASTEWATER PERM INSPECTION ¤80.00 06/02/2025
WASTEWATER PERM REVIEW ¤25.00 06/02/2025
FC IMPACT FEE EMS ¤62.00 06/02/2025
IMPACT FEE FIRE ¤434.51 06/02/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 06/02/2025
FC IMPACT FEE LIBRARY ¤268.00 06/02/2025
IMPACT FEE PARKS ¤1,828.01 06/02/2025
IMPACT FEE SCHOOL ¤5,450.00 06/02/2025
IMPACT FEE TRANSPORTATION ¤1,916.00 06/02/2025
SURCHARGE FS 533.721 ¤14.28 06/02/2025
SURCHARGE - FS 468.631 ¤21.42 06/02/2025
SW ENG - FOUNDATION SURVEY ¤20.00 06/02/2025
WATER PERMIT REVIEW ¤25.00 06/02/2025
SITE PLAN 30 ¤30.00 06/02/2025
WATER- TURN ON ¤50.00 05/15/2025
WATER MAIN EXTENSION IMPACT ¤854.40 05/15/2025
PEP TANK INSTALL ¤756.74 05/15/2025
WASTEWATER MAIN EXTENSION IMPA ¤2,189.82 05/15/2025
SEWER CAPITAL FACILITY ¤3,930.70 05/15/2025
WATER CAPITAL FACILITY FEE ¤3,496.74 05/15/2025
WATER METER W/ TAP ¤2,326.93 05/15/2025
SEWER CREDIT (¤1,466.00) 05/15/2025
Fees Total Due: ¤0.00 Total Paid: ¤24,857.11