I want to search for...
Permit #2025041124
Permit Details
Status: COED
| Parcel Id: 07-11-31-7033-00340-0320 |
| CONDITIONED SPACE: 1809 sqft |
| GARAGE: 406 sqft |
| OPENED PORCH (WITH ROOF) : 33 sqft |
| Total Square Footage: 2248 sqft |
| Block: 00340 |
| Subdivision: - |
| Job Phone: 239-571-5325 |
| Location Address: 27 RED BIRCH LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 05/16/2025 |
| NOC: RECORDED |
| Applicant name: RYAN SCOTT DAVIS |
| Owner: SYNERGY HOMES LLC |
|
Address 581 NW MERCANTILE PLACE PORT SAINT LUCIE, FL 34986 |
|
Address 106 PORT SAINT LUCIE, FL 34986 |
| Lot: 0320 |
| Contracted Stated Job Value: ¤200,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
SYNERGY HOMES, LLC
| Status | Location Address | State License Number |
| ACTIVE |
1 HARGROVE GRADE, SUITE B1 PALM COAST, FL 32137 |
CBC1254289 (Exp: 08/31/2026) |
Sub Contractors
TERRY BRICE DICKERSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4300 ST JOHN'S PARKWAY ALPHARETTA, GA 30009 |
CCC1326209 (Exp: 08/31/2026) | 407-548-6733 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
MICHAEL FRANK MORELLO
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2 HARGROVE GRADE PALM COAST, FL 32164 |
CAC1819466 (Exp: 08/31/2026) | 386-445-5023 | 386-446-4614 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 10/30/2025 | CANCELLED BY APPLICANT | WEB |
| BLD - BUILDING FINAL | 10/30/2025 | FINAL APPROVED | JSTEWART |
| U -UTILITY RESIDENTIAL FINAL | 10/30/2025 | FINAL APPROVED | BWRIGHT |
| Note: Inspector Notes from Inspection 9035 no irr-no cc | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 10/29/2025 | APPROVED | TPOLACEK |
| Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 10/28/2025 - PREVIOUS INSPECTION NOTES 10-28-25 TPOLACEK** BUILDER REQUESTED TO CANCEL FOR TODAYS INSPECTION 10/24/2025 - PREVIOUS INSPECTION NOTES 10-24-25 TPOLACEK*** LEFT SIDE PROPERTY LINE ABOUT 10' BEHIND THE METER TO THE FRONT SWALE NEEDS TO BE LOWERED TO ALLOW THE DRAINAGE TO REACH THE FRONT SWALE. RIGHT SIDE OF CULVERT NEEDS SOD TO MATCH GRADE AS THIS AREA IS BARE AND A LITTLE HIGH. | |||
| ROW - STORMWATER FINAL | 10/29/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - FINAL APRON (AFTER POUR) | 10/29/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 10/28/2025 | CANCELLED BY APPLICANT | TPOLACEK |
| Note: 10-28-25 TPOLACEK** BUILDER REQUESTED TO CANCEL FOR TODAYS INSPECTION 10/24/2025 - PREVIOUS INSPECTION NOTES 10-24-25 TPOLACEK*** LEFT SIDE PROPERTY LINE ABOUT 10' BEHIND THE METER TO THE FRONT SWALE NEEDS TO BE LOWERED TO ALLOW THE DRAINAGE TO REACH THE FRONT SWALE. RIGHT SIDE OF CULVERT NEEDS SOD TO MATCH GRADE AS THIS AREA IS BARE AND A LITTLE HIGH. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 10/24/2025 | APPROVED | TPOLACEK |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 10/24/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 10-24-25 TPOLACEK*** LEFT SIDE PROPERTY LINE ABOUT 10' BEHIND THE METER TO THE FRONT SWALE NEEDS TO BE LOWERED TO ALLOW THE DRAINAGE TO REACH THE FRONT SWALE. RIGHT SIDE OF CULVERT NEEDS SOD TO MATCH GRADE AS THIS AREA IS BARE AND A LITTLE HIGH. | |||
| GRAVITY SEWER TEST | 09/09/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION 9/8/2025 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2060 DUE TO RAIN UNCOVER PIPE FOR INSPECTION SWALE BLOCKED FBC3303.5 | |||
| SEWER TIE IN | 09/09/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION 9/8/2025 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2060 UNCOVER CONNECTION SWALE BLOCKED FBC3303.5 | |||
| ELECTRIC - EARLY POWER | 09/09/2025 | APPROVED | CVANSTRAHLEN |
| SEWER TIE IN | 09/08/2025 | Disapproved - NO FEE | MGIBSON |
| Note: Inspector Notes from Inspection 2060 UNCOVER CONNECTION SWALE BLOCKED FBC3303.5 | |||
| GRAVITY SEWER TEST | 09/08/2025 | Disapproved - NO FEE | MGIBSON |
| Note: Inspector Notes from Inspection 2060 DUE TO RAIN UNCOVER PIPE FOR INSPECTION SWALE BLOCKED FBC3303.5 | |||
| ROW- PRE-APRON (PRE-POUR) | 09/05/2025 | APPROVED - AS NOTED | TPOLACEK |
| Note: 09-05-25 TPOLACEK**** BUILDER MUST REMOVE WATER FROM POUR AREA REESTABLISH FOOTERS BEFORE POURING AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. 9/3/2025 - PREVIOUS INSPECTION NOTES 09-03-25 TPOLACEK** SITE IS NOT READY FOR INSPECTION POUR AREA IS SOFT AND FOOTERS ARE WASHED IN HOLDING WATER. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 8/28/2025 - PREVIOUS INSPECTION NOTES TPOLACEK*** RECIEVED TEXT FROM CM ASKING TO CANCEL INSPECTION ++++++++++++++++++++++++++++++++++++++++++++++++++++++ 8/27/2025 - PREVIOUS INSPECTION NOTES 08/27/25 TPOLACEK*** RECIEVED TEXT FROM CM ASKING TO CANCEL INSPECTION | |||
| ROW- PRE-APRON (PRE-POUR) | 09/03/2025 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 09-03-25 TPOLACEK** SITE IS NOT READY FOR INSPECTION POUR AREA IS SOFT AND FOOTERS ARE WASHED IN HOLDING WATER. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 8/28/2025 - PREVIOUS INSPECTION NOTES TPOLACEK*** RECIEVED TEXT FROM CM ASKING TO CANCEL INSPECTION ++++++++++++++++++++++++++++++++++++++++++++++++++++++ 8/27/2025 - PREVIOUS INSPECTION NOTES 08/27/25 TPOLACEK*** RECIEVED TEXT FROM CM ASKING TO CANCEL INSPECTION | |||
| ROW- PRE-APRON (PRE-POUR) | 08/28/2025 | CANCELLED BY APPLICANT | TPOLACEK |
| Note: TPOLACEK*** RECIEVED TEXT FROM CM ASKING TO CANCEL INSPECTION ++++++++++++++++++++++++++++++++++++++++++++++++++++++ 8/27/2025 - PREVIOUS INSPECTION NOTES 08/27/25 TPOLACEK*** RECIEVED TEXT FROM CM ASKING TO CANCEL INSPECTION | |||
| ROW- PRE-APRON (PRE-POUR) | 08/27/2025 | CANCELLED BY APPLICANT | TPOLACEK |
| Note: 08/27/25 TPOLACEK*** RECIEVED TEXT FROM CM ASKING TO CANCEL INSPECTION | |||
| PEP TANK INSTALLATION REQUEST | 08/22/2025 | APPROVED | CBOWERMASTER |
| INSULATION | 08/22/2025 | APPROVED | CVANSTRAHLEN |
| Note: 8/21/2025 - PREVIOUS INSPECTION NOTES not ready | |||
| INSULATION | 08/21/2025 | Disapproved - NO FEE | CVANSTRAHLEN |
| Note: not ready | |||
| LATH/BRICK/ WATER BARRIER | 08/20/2025 | APPROVED - AS NOTED | CVANSTRAHLEN |
| Note: Previous items still pending Inspector Notes from Inspection 2420 Please fix items before next inspection #1- missing Fl approval sheet #2-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW | |||
| ALL ROUGH | 08/19/2025 | APPROVED - AS NOTED | CVANSTRAHLEN |
| Note: Please fix items before next inspection #1- missing Fl approval sheet #2-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW | |||
| ALL ROUGH | 08/14/2025 | CANCELLED BY APPLICANT | WEB |
| WALL SHEATHING | 08/12/2025 | CANCELLED BY INSPECTOR | CVANSTRAHLEN |
| Note: | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/12/2025 | APPROVED | CVANSTRAHLEN |
| Note: | |||
| ROOF VALLEY & METAL | 08/12/2025 | APPROVED | CVANSTRAHLEN |
| Note: | |||
| FORMBOARD SURVEY (OFFICE USE ONLY) | 08/11/2025 | APPROVED | RRICKS |
| TIE BEAM / LINTEL | 07/31/2025 | APPROVED - AS NOTED | CVANSTRAHLEN |
| Note: #-FBC 3303.5-SWALE CLEAR ( please moved porta potty of swale ) #-Trusses in place , not mitek pack or delivery sheet to confirm date of delivery | |||
| U-CROSS CONNECTION | 07/30/2025 | APPROVED - AS NOTED | LFITZGERALD |
| Note: no irr-no cc | |||
| MONOLITHIC SLAB | 07/22/2025 | APPROVED | CVANSTRAHLEN |
| MONOLITHIC SLAB | 07/21/2025 | Disapproved - NO FEE | CVANSTRAHLEN |
| Note: Please fix item before next inspection #1-FBCR 318-TERMITE TREATMENT OR NOTICE OF INTENT FOR BORACARE | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 07/18/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: SWALE BLOCKED FBC3303.5 | |||
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 07/10/2025 | APPROVED | JMUNSON |
| WATER METER INSTALLATION REQUEST | 06/27/2025 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| RSI | COMPLETE | 07/14/2025 | 07/17/2025 |
| Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/14/2025 | 07/14/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 07/10/2025 | 07/10/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 05/08/2025 | 05/15/2025 |
| Note: Released By: RODNEY RICKS - (386)986-2001 - RRICKS@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 05/08/2025 | 05/08/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/08/2025 | 05/08/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM No zoning changes only stormwater | |||
| BADMIN | COMPLETE | 04/22/2025 | 04/28/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/22/2025 | 04/28/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 04/22/2025 | 04/30/2025 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 04/22/2025 | 04/28/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 04/22/2025 | 04/22/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 04/22/2025 | 04/24/2025 |
| LOCATE | COMPLETE | 04/22/2025 | 04/29/2025 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 04/22/2025 | 04/25/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 04/22/2025 | 04/30/2025 |
| Note: Held By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM The proposed berm on the left side is not needed. | |||
| ZON | COMPLETE | 04/22/2025 | 04/23/2025 |
| Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 04/22/2025 | 05/08/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| SW ENG REINSPECTION 30 | ¤30.00 | 10/31/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 05/16/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 05/16/2025 |
| WATER METER W/ TAP | ¤2,326.93 | 05/16/2025 |
| SEWER CREDIT | (¤580.42) | 05/16/2025 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 05/16/2025 |
| WASTEWATER PERM REVIEW | ¤25.00 | 05/16/2025 |
| SEWER CAPITAL FACILITY | ¤3,930.70 | 05/16/2025 |
| WATER CAPITAL FACILITY FEE | ¤3,496.74 | 05/16/2025 |
| WATER PERMIT REVIEW | ¤25.00 | 05/16/2025 |
| WATER MAIN EXTENSION IMPACT | ¤854.40 | 05/16/2025 |
| SITE PLAN 30 | ¤30.00 | 05/16/2025 |
| WATER- TURN ON | ¤50.00 | 05/16/2025 |
| ADJUSTMENT 10% | (¤120.20) | 05/16/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 05/16/2025 |
| INSPECTION - RESIDENTIAL | ¤913.00 | 05/16/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤258.96 | 05/16/2025 |
| FC IMPACT FEE EMS | ¤62.00 | 05/16/2025 |
| IMPACT FEE FIRE | ¤434.51 | 05/16/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 05/16/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 05/16/2025 |
| IMPACT FEE PARKS | ¤1,828.01 | 05/16/2025 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 05/16/2025 |
| IMPACT FEE TRANSPORTATION | ¤1,916.00 | 05/16/2025 |
| PEP TANK INSTALL | ¤756.74 | 05/16/2025 |
| WASTEWATER MAIN EXTENSION IMPA | ¤2,189.82 | 05/16/2025 |
| SURCHARGE FS 533.721 | ¤10.82 | 05/16/2025 |
| SURCHARGE - FS 468.631 | ¤16.23 | 05/16/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 05/16/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 05/16/2025 |
| SW ENG PRE APRON | ¤30.00 | 05/16/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤24,850.24 |