I want to search for...

Permit #2025041133

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7014-00020-1650
Block: 00020
Subdivision: -
Job Phone: 386-693-4884
Location Address: 3 COLLINGDALE CT
Type: DK - DOCK
Issue Date: 04/22/2025
NOC: RECORDED
Applicant name: JOHN D GOBLER
Owner: LEWANDOWSKI FRED A & DIANE L LEWANDOWSKI H&W LIFE

Address

3 COLLINGDALE COURT

PALM COAST, FL 32137

Lot: 1650
Contracted Stated Job Value: ¤6,000.00
Job Description: DOCK REPAIR REF#2024050854
Type: CN
Original Permit #: 2024050854

Contractor

MARITIME CONSTRUCTION INC
Status Location Address State License Number Phone Fax
ACTIVE

P.O. BOX 2014

FLAGLER BEACH, FL 32136

CBC1254215 (Exp: 08/31/2026) 386-693-4884 386-693-4897

Inspection History

Type Request Date Result Inspector
FINAL - BUILDING MISC 10/24/2025 FINAL APPROVED HCAMACHO
Note: 4/23/2025 - PREVIOUS INSPECTION NOTES 1. Dock repair not done according to plans submitted. Missing 2x8 cap beams on several areas. (Marked) 2. There is an extra part of the boat slip that was repaired that is not shown on the plans or site plan. Please revise plans to show all parts of the dock. (Marked)
FINAL - BUILDING MISC 04/23/2025 Disapproved - NO FEE HCAMACHO
Note: 1. Dock repair not done according to plans submitted. Missing 2x8 cap beams on several areas. (Marked) 2. There is an extra part of the boat slip that was repaired that is not shown on the plans or site plan. Please revise plans to show all parts of the dock. (Marked)

Review History

Department Status Date In Date Out
BLD COMPLETE 03/07/2025 03/10/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
ZON COMPLETE 06/27/2024 06/27/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 06/27/2024 06/28/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SW1 COMPLETE 06/27/2024 07/09/2024
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
BLD COMPLETE 06/21/2024 06/25/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON HOLD 06/21/2024 06/21/2024
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM REPEAT COMMENTS: 6/21/24 1. ORIGINAL AGREEMENT RECEIVED. 2. Please note that you must demonstrate that the proposed re-framing does not exceed 20' out and 20' over from both seawalls. (the one you are building on and the one with the shared corner - you will also see this demonstrated in the design standards I have emailed. 3. Please re-submit the site plan. You are STILL showing the dock in the wrong spot. The dock needs to be shown in the WATERBODY, not on land. YOU WILL SEE THE VERBIAGE COLLINGWOOD BASIN ON THE WATERBODY AREA OF THE SITE PLAN.
SW1 COMPLETE 06/21/2024 06/24/2024
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 06/13/2024 06/13/2024
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM REPEAT COMMENTS: 1. Please correct the parcel ID on page 1 of the License Agreement. Once corrected, please submit the original. UPDATE 6/13/24 - ORIGINAL AGREEMENT RECEIVED 2. I have emailed you the City of Palm Coast design standards for corner docks. What you have submitted does not meet the current Land Development Code. The maximum length allowed for a dock is 65% of the frontage, which is 37'. In order to not be in the 45 degree angle at the corner, your dock must be set back from the corner as far as the projection - for example, if you are building the left side of the dock at a dimension of 8', you will need to be 8' from the corner in order to meet the 45' angle requirement. Also, there is a 15' storm drainage easement on the right side and as you will see from the City's design standards, you can encroach up to 7.5' in that easement. Please also note that you must demonstrate that the proposed re-framing does not exceed 20' out and 20' over from both seawalls. (the one you are building on and the one with the shared corner - you will also see this demonstrated in the design standards I have emailed. I have also emailed you the previously approved dock layout. 3. Please re-submit the site plan. You are showing the dock in the wrong spot. The dock needs to be shown in the waterbody, not on land. You will also need to change the dimensions to meet all of the items described in #2 above so that the site plan mirrors the engineered drawings. Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM REPEAT COMMENTS: 1. Please correct the parcel ID on page 1 of the License Agreement. Once corrected, please submit the original. 2. I have emailed you the City of Palm Coast design standards for corner docks. What you have submitted does not meet the current Land Development Code. The maximum length allowed for a dock is 65% of the frontage, which is 37'. In order to not be in the 45 degree angle at the corner, your dock must be set back from the corner as far as the projection - for example, if you are building the left side of the dock at a dimension of 8', you will need to be 8' from the corner in order to meet the 45' angle requirement. Also, there is a 15' storm drainage easement on the right side and as you will see from the City's design standards, you can encroach up to 7.5' in that easement. Please also note that you must demonstrate that the proposed re-framing does not exceed 20' out and 20' over from both seawalls. (the one you are building on and the one with the shared corner - you will also see this demonstrated in the design standards I have emailed. I have also emailed you the previously approved dock layout. 3. Please re-submit the site plan. You are showing the dock in the wrong spot. The dock needs to be shown in the waterbody, not on land. You will also need to change the dimensions to meet all of the items described in #2 above so that the site plan mirrors the engineered drawings.
ZON HOLD 06/13/2024 06/13/2024
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM REPEAT COMMENTS: 1. Please correct the parcel ID on page 1 of the License Agreement. Once corrected, please submit the original. 2. I have emailed you the City of Palm Coast design standards for corner docks. What you have submitted does not meet the current Land Development Code. The maximum length allowed for a dock is 65% of the frontage, which is 37'. In order to not be in the 45 degree angle at the corner, your dock must be set back from the corner as far as the projection - for example, if you are building the left side of the dock at a dimension of 8', you will need to be 8' from the corner in order to meet the 45' angle requirement. Also, there is a 15' storm drainage easement on the right side and as you will see from the City's design standards, you can encroach up to 7.5' in that easement. Please also note that you must demonstrate that the proposed re-framing does not exceed 20' out and 20' over from both seawalls. (the one you are building on and the one with the shared corner - you will also see this demonstrated in the design standards I have emailed. I have also emailed you the previously approved dock layout. 3. Please re-submit the site plan. You are showing the dock in the wrong spot. The dock needs to be shown in the waterbody, not on land. You will also need to change the dimensions to meet all of the items described in #2 above so that the site plan mirrors the engineered drawings.
BLD HOLD 05/16/2024 05/22/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Answer zoning comments
ZON HOLD 05/16/2024 05/16/2024
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM 1. Please correct the parcel ID on page 1 of the License Agreeent. Once corrected, please submit the original. 2. I have emailed you the City of Palm Coast design standards for corner docks. What you have submitted does not meet the current Land Development Code. The maximum length allowed for a dock is 65% of the frontage, whch is 37'. In order to not be in the 45 degree angle at the corner, your dock must be set back from the corner as far as the projection - for example, if you are building the left side of the dock at a dimension of 8', you will need to be 8' from the corner in order to meet the 45' angle requirement. Also, there is a 15' storm drainage easement on the right side and as you will see from the City's design standards, you can encroach up to 7.5' in that easement. Please also note that you must demonstrate that the proposed re-framing does not exceed 20' out and 20' over from both seawalls. (the one you are building on and the one with the shared corner - you will also see this demonstrated in the design standards I have emailed. I have also emailed you the previously approved dock layout. 3. Please re-submit the site plan. You are showing the dock in the wrong spot. The dock needs to be shown in the waterbody, not on land. You will also need to change the dimensions to meet all of the items described in #2 above so that the site plan mirrors the engineered drawings.
SW1 COMPLETE 05/16/2024 05/28/2024
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM Will not affect Stormwater Drainage.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EXTENSION ¤40.00 10/23/2025
INSPECTION - RESIDENTIAL ¤60.00 04/22/2025
SURCHARGE FS 533.721 ¤2.00 04/22/2025
SURCHARGE - FS 468.631 ¤2.00 04/22/2025
SITE PLAN 30 ¤30.00 04/22/2025
ADJUSTMENT 10% (¤9.00) 04/22/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/22/2025
Fees Total Due: ¤0.00 Total Paid: ¤155.00