Permit #2025041137

Permit Details

Status: ISSUED

Parcel Id: 07-11-31-1090-000C0-0000
Block: 000C0
Subdivision: 1228 - SOUTHWEST QUADRANT
Job Phone: 386-264-3189
Location Address: 160 CYPRESS POINT PKWY
Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION
Issue Date: 05/18/2026
NOC: RECORDED
Applicant name: WILLIAM PIERCE STOUGHTON
Owner: Q BILLETTE, LLC

Address

160 CYPRESS POINT PKWY

PALM COAST, FL 32164

Lot: 0000
Contracted Stated Job Value: ¤185,000.00
Job Description: Unit C111 & C 112 Remodel - CUE NOTE BILLIARD ROOM
Type: CN

Contractor

STOUGHTON & DURAN CUSTOM HOMES LLC
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 1478

BUNNELL, FL 32110

CGC047560 (Exp: 08/31/2026) 386-627-8993 866-576-9888

Sub Contractors

MOISES MERINO DIAZ
Status Location Address State License Number Phone
ACTIVE

3104 ORANOLE ROAD

ORLANDO, FL 32810

CAC1820980 (Exp: 08/31/2026) 407-225-3149
MARK JOHN LUTCZA
Status Location Address State License Number Phone
ACTIVE

26 ROYAL LEAF LANE

PALM COAST, FL 32164

EC13005145 (Exp: 08/31/2026) 386-586-0770
JEFFREY TROY SABAKA
Status Location Address State License Number Phone Fax
ACTIVE

2191 DEERWOOD ACRES DR

ST AUGUSTINE, FL 32084

CFC1427439 (Exp: 08/31/2026) 904-838-2218 904-819-0965

Inspection History

Type Request Date Result Inspector
PLUMBING 2ND ROUGH
PLUMBING FINAL
HVAC ROUGH
HVAC FINAL
ELECTRIC 2ND ROUGH
ELECTRIC FINAL
GAS ROUGH
GAS FINAL
LATH/BRICK/WATER BARRIER
LINTEL
FRAMING
FIREWALL FINAL
FIREWALL PENETRATIONS
FIREWALL DRYWALL NAILING
ABOVE CEILING
WALL SHEATHING
INSULATION
STOREFRONT
BUILDING FINAL
FIRE FINAL
U - UTILITY COMMERCIAL FINAL

Review History

Department Status Date In Date Out
PLUM COMPLETE 05/15/2026 05/18/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
PLUM HOLD 05/07/2026 05/07/2026
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM ALL COMMENTS FROM FBC PLUMBING, FBC EXISTING BUILDING, AND FBC ACCESSIBILITY 2023. RESUBMITTED PLAN PAGES NEED TO BE CLOUDED AND MUST HAVE A REPONSE LETTER FROM THE ENGINEER SIGNED AND SEALED 1. OK 2. OK 3. OK 4. OK REPEAT COMMENT: 5. Revise minimum plumbing facilities table. Use Nightclub, bars, taverns in table assembly 403.1. Provide correct number of bathrooms per table. Current occupant load for amont of bathrooms would be 240.
ELEC COMPLETE 05/07/2026 05/11/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC HOLD 04/30/2026 05/05/2026
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit updated electrical plan
FI1 COMPLETE 04/30/2026 05/05/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
PLUM HOLD 04/30/2026 05/05/2026
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM ALL COMMENTS FROM FBC PLUMBING, FBC EXISTING BUILDING, AND FBC ACCESSIBILITY 2023. RESUBMITTED PLAN PAGES NEED TO BE CLOUDED AND MUST HAVE A REPONSE LETTER FROM THE ENGINEER SIGNED AND SEALED 1. OK 2. OK 3. OK 4. OK REPEAT COMMENT: 5. Revise minimum plumbing facilities table. Use Nightclub, bars, taverns in table assembly 403.1. Provide correct number of bathrooms per table. Current occupant load for amont of bathrooms would be 240.
BLD COMPLETE 04/30/2026 05/05/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH COMPLETE 04/30/2026 05/05/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN INFORMATION 04/28/2026 04/28/2026
Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM RENAME TO 1.PDF, 2.PDF, ...
ELEC HOLD 03/05/2026 03/06/2026
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Spoke to contractor
FI1 HOLD 03/05/2026 03/06/2026
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Spoke to contractor
MECH HOLD 03/05/2026 03/06/2026
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Spoke to contractor
PLUM HOLD 03/05/2026 03/06/2026
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Spoke to contractor
BLD HOLD 03/05/2026 03/06/2026
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Spoke to contractor
MECH HOLD 03/03/2026 03/04/2026
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM ALL COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING, FLORIDA BUILDING CODE-EXISTING BUILDING, FLORIDA BUILDING CODE-MECHANICAL AND FLORIDA BUILDING CODE -ENERGY CONSERVATION. RESUBMITTED PLAN PAGES NEED TO BE CLOUDED AND MUST HAVE A REPONSE LETTER FROM THE ENGINEER SIGNED AND SEALED NO REVIEW COMPLETED HVAC, REFRIGERATION AND HOOD SYSTEM INSTALLED UNDER PREVIOUS PERMIT WAS NEVER INSPECTED. THEY WILL NEED TO CONFORM TO 2023 FBC 1.ok REPEAT COMMENT: 2. Provide Heatload Calculation per C403.2.1 FBC Energy Conservation 2023 3. ok 4. ok REPEAT COMMENT: 5. Update equipment schedule to show current available equipment 6. ok 7. ok 8. ok NEW COMMENT: All plan sheets need to be uploaded separately and each sheet needs to have a verifiable digital signature
BLD HOLD 03/03/2026 03/04/2026
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM NO REVIEW COMPLETED. All plan sheets need to be uploaded separately and have a verifiable digital signature
PLUM HOLD 03/03/2026 03/04/2026
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM NO REVIEW COMPLETED ALL COMMENTS FROM FBC PLUMBING, FBC EXISTING BUILDING, AND FBC ACCESSIBILITY 2023. RESUBMITTED PLAN PAGES NEED TO BE CLOUDED AND MUST HAVE A REPONSE LETTER FROM THE ENGINEER SIGNED AND SEALED 1. OK 2. OK 3. OK 4. OK REPEAT COMMENT: 5. Revise minimum plumbing facilities table. Use Nightclub, bars, taverns in table assembly 403.1. Provide correct number of bathrooms per table. Label men and womans on plans. Based on potty parity in 403.1.3 you need 7 womens w.c. to 5 men ( NO ARCHITECTURAL LETTER OR PLANS UPLOADED)
ELEC HOLD 03/03/2026 03/03/2026
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. All outlets including 240 volt must be GFCI protected in all areas mentioned in NEC 2020 210.8 (B) 2. Kitchen is not existing and never was permitted. Needs to be included in your drawings.
FI1 HOLD 03/03/2026 03/03/2026
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit a life safety plan that includes travel distance to all exits, fire extinguishers, etc. 2. Kitchen was not permitted needs to be included in your plans.
BLD HOLD 02/23/2026 03/02/2026
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM NEED TO UPLOAD NEW ARCHITECTURAL PLANS
ELEC HOLD 02/23/2026 03/03/2026
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. All outlets including 240 volt must be GFCI protected in all areas mentioned in NEC 2020 210.8 (B) 2. Kitchen is not existing and never was permitted. Needs to be included in your drawings.
FI1 HOLD 02/23/2026 03/03/2026
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit a life safety plan that includes travel distance to all exits, fire extinguishers, etc. 2. Kitchen was not permitted needs to be included in your plans.
MECH HOLD 02/23/2026 03/02/2026
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM THIS THE CORRECT REVIEW. PREVIOUS HAD AN ERROR. ALL COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING, FLORIDA BUILDING CODE-EXISTING BUILDING, FLORIDA BUILDING CODE-MECHANICAL AND FLORIDA BUILDING CODE -ENERGY CONSERVATION. RESUBMITTED PLAN PAGES NEED TO BE CLOUDED AND MUST HAVE A REPONSE LETTER FROM THE ENGINEER SIGNED AND SEALED NO LETTER SUBMITTED HVAC, REFRIGERATION AND HOOD SYSTEM INSTALLED UNDER PREVIOUS PERMIT WAS NEVER INSPECTED. THEY WILL NEED TO CONFORM TO 2023 FBC 1.ok REPEAT COMMENT: 2. Provide Heatload Calculation per C403.2.1 FBC Energy Conservation 2023 3. ok 4. ok REPEAT COMMENT: 5. Update equipment schedule to show current available equipment 6. ok 7. ok 8. ok
UD2 COMPLETE 02/23/2026 02/23/2026
Note: Released By: DAN LEMONCELLO - -
PLUM HOLD 02/23/2026 03/02/2026
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM ALL COMMENTS FROM FBC PLUMBING, FBC EXISTING BUILDING, AND FBC ACCESSIBILITY 2023. RESUBMITTED PLAN PAGES NEED TO BE CLOUDED AND MUST HAVE A REPONSE LETTER FROM THE ENGINEER SIGNED AND SEALED 1. OK 2. OK 3. OK 4. OK REPEAT COMMENT: 5. Revise minimum plumbing facilities table. Use Nightclub, bars, taverns in table assembly 403.1. Provide correct number of bathrooms per table. Label men and womans on plans. Based on potty parity in 403.1.3 you need 7 womens w.c. to 5 men ( NO ARCHITECTURAL LETTER OR PLANS UPLOADED)
MECH HOLD 02/23/2026 03/02/2026
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM ALL COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING, FLORIDA BUILDING CODE-EXISTING BUILDING, FLORIDA BUILDING CODE-MECHANICAL AND FLORIDA BUILDING CODE -ENERGY CONSERVATION. RESUBMITTED PLAN PAGES NEED TO BE CLOUDED AND MUST HAVE A REPONSE LETTER FROM THE ENGINEER SIGNED AND SEALED NO LETTER SUBMITTED HVAC, REFRIGERATION AND HOOD SYSTEM INSTALLED UNDER PREVIOUS PERMIT WAS NEVER INSPECTED. THEY WILL NEED TO CONFORM TO 2023 FBC REPEAT COMMENT: 1. Provide Energy Calculations per C407 FBC Energy Conservation 2023 REPEAT COMMENT: 2. Provide Heatload Calculation per C403.2.1 FBC Energy Conservation 2023 3. ok 4. ok REPEAT COMMENT: 5. Update equipment schedule to show current available equipment 6. ok 7. ok 8. ok
BLD HOLD 02/11/2026 02/23/2026
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM NO REVIEW COMPLETED. PLAN PAGES NEED TO BE UPLOADED SEPARATELY NOT IN GROUPS COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE (FBC), FLORIDA BUILDING CODE-EXISTING BUILDING, FLORIDA BUILDING CODE-ACCESSIBILITY (FBCA), FLORIDA STATUTES (F.S.), FLORIDA ADMINISTRATIVE CODE (F.A.C.) AND AUTHORITY HAVING JURISDICTION (A.H.J.). 1. Plans need to reference FBC Building, FBC Existing Building and FBC Accessibility 2023 2. Provide code analysis. Show construction type, egress capacity and requirements, wind loads ,design loads, etc... 107.3.5 FBC Building 3. Provide accessible bar area, Show approach dimensions, counter height and knee and toe clearance 902.1-902.3/904.4/ 306 FBC Accessibility 2023 4. Provide construction details of stage and ramp. Include material type, spacing , attachment details, live and dead loads, etc...107.3.5 FBC Building 2023 5. Provide note or details showing accessible seating for booths 902.2, 902.3, 306 FCB Accessibility 2023
UD2 HOLD 02/11/2026 02/11/2026
Note: Held By: DAN LEMONCELLO - - 1) answer all the questions asked on previous HOLD from 5/6/2025. 2) grease interceptor sizing needs to be recalculated according to FBC 2023 formula. Could require a larger capacity for grease waste 3) For questions, contact Utility Wastewater Pretreatment Inspector Dan Lemoncello @ llemoncello@palmcoastgov.com or (386)286-2011.
FI1 HOLD 02/11/2026 02/23/2026
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM NO REVIEW COMPLETED. PLAN PAGES NEED TO BE UPLOADED SEPARATELY NOT IN GROUPS 1. Submit a life safety plan tht includes travel distanceto all exits, fire extiuguishers, etc.
ELEC HOLD 02/11/2026 02/23/2026
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM NO REVIEW COMPLETED. PLAN PAGES NEED TO BE UPLOADED SEPARATELY NOT IN GROUPS 1. All outlets including 240 volt must be GFCI protected in all areas mentioned in NEC 2020 210.8 (B)
MECH HOLD 02/11/2026 02/23/2026
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM NO REVIEW COMPLETED. PLAN PAGES NEED TO BE UPLOADED SEPARATELY NOT IN GROUPS ALL COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING, FLORIDA BUILDING CODE-EXISTING BUILDING, FLORIDA BUILDING CODE-MECHANICAL AND FLORIDA BUILDING CODE -ENERGY CONSERVATION. RESUBMITTED PLAN PAGES NEED TO BE CLOUDED AND MUST HAVE A REPONSE LETTER FROM THE ENGINEER SIGNED AND SEALED 1. Provide Energy Calculations per C407 FBC Energy Conservation 2023 2. Provide Heatload Calculation per C403.2.1 FBC Energy Conservation 2023 3. Provide condensate termination details for walk in cooler/AC unit. Cannot run into sanitary sewer system per Palm Coast Municiple Code Section 49-104 (12) 4. Provide Ventilation calculation per Table 403.3.1.1 from 2023 code cycle. Use bars and cocktail lounge for correct calculation. show formula. FBC Mechanical 2023 5. Update equipment schedule to show current available equipment 6. Hood will need to be on a separate permit 7. Walk in cooler to be on separte permit 8. Hood exhaust fan need to extend beyond building to have clearance away from openings into building and combustible awning. (Can be part of the hood permit. Just an FYI)
PLUM HOLD 02/11/2026 02/23/2026
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM NO REVIEW COMPLETED. PLAN PAGES NEED TO BE UPLOADED SEPARATELY NOT IN GROUPS ALL COMMENTS FROM FBC PLUMBING, FBC EXISTING BUILDING, AND FBC ACCESSIBILITY 2023. RESUBMITTED PLAN PAGES NEED TO BE CLOUDED AND MUST HAVE A REPONSE LETTER FROM THE ENGINEER SIGNED AND SEALED 1. Plan page P001. Update code year under Plumbing general notes. to 2023 2. Provide backflow device schedule. List various backflow devices, manufacturer, model and applicable design standard they must conform to for each device type. Section 608. Table 608.1. Backflow preventer required at hose-bibbs, janitor sink, ice-maker, and any other water utilizing appliance connected to the water system including any not shown in the plans (e.g. coffee maker or soda machine with direct water supply connection). 3. Provide plumbing supply riser diagram on separate plan page. 107.2.1 4. Provide sanitary riser diagram on separate plan page. .107.2.1 5. Revise minimum plumbing facilities table. Use Nightclub, bars, taverns in table assembly 403.1. Provide correct number of bathrooms per table. Label men and womans on plans. Based on potty parity in 403.1.3 you need 7 womens w.c. to 5 men
BLD HOLD 02/11/2026 02/23/2026
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM NO REVIEW COMPLETED. PLAN PAGES NEED TO BE UPLOADED SEPARATELY NOT IN GROUPS
BADMIN INFORMATION 01/26/2026 01/26/2026
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM A 30 day extension is to be granted. There will not be any more extensions granted and this will be come a code enforcement case. The orginal permit expired quite some time ago. It has not been resolved. This permit was applied for in April and has already been extended once.
BLD HOLD 04/22/2025 05/06/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE (FBC), FLORIDA BUILDING CODE-EXISTING BUILDING, FLORIDA BUILDING CODE-ACCESSIBILITY (FBCA), FLORIDA STATUTES (F.S.), FLORIDA ADMINISTRATIVE CODE (F.A.C.) AND AUTHORITY HAVING JURISDICTION (A.H.J.). 1. Plans need to reference FBC Building, FBC Existing Building and FBC Accessibility 2023 2. Provide code analysis. Show construction type, egress capacity and requirements, wind loads ,design loads, etc... 107.3.5 FBC Building 3. Provide accessible bar area, Show approach dimensions, counter height and knee and toe clearance 902.1-902.3/904.4/ 306 FBC Accessibility 2023 4. Provide construction details of stage and ramp. Include material type, spacing , attachment details, live and dead loads, etc...107.3.5 FBC Building 2023 5. Provide note or details showing accessible seating for booths 902.2, 902.3, 306 FCB Accessibility 2023
DSD COMPLETE 04/22/2025 04/25/2025
Note: Released By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM
ELEC HOLD 04/22/2025 05/05/2025
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. All outlets including 240 volt must be GFCI protected in all areas mentioned in NEC 2020 210.8 (B)
FI1 HOLD 04/22/2025 05/05/2025
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit a life safety plan tht includes travel distanceto all exits, fire extiuguishers, etc. 2. FFPC 8th edition7.2.2.3.1.2 Each stair, platform, and landing, not including handrails and existing stairs, in buildings required in this Code to be of Type I or Type II construction shall be of noncombustible material throughout.
MECH HOLD 04/22/2025 05/06/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM ALL COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING, FLORIDA BUILDING CODE-EXISTING BUILDING, FLORIDA BUILDING CODE-MECHANICAL AND FLORIDA BUILDING CODE -ENERGY CONSERVATION. RESUBMITTED PLAN PAGES NEED TO BE CLOUDED AND MUST HAVE A REPONSE LETTER FROM THE ENGINEER SIGNED AND SEALED 1. Provide Energy Calculations per C407 FBC Energy Conservation 2023 2. Provide Heatload Calculation per C403.2.1 FBC Energy Conservation 2023 3. Provide condensate termination details for walk in cooler/AC unit. Cannot run into sanitary sewer system per Palm Coast Municiple Code Section 49-104 (12) 4. Provide Ventilation calculation per Table 403.3.1.1 from 2023 code cycle. Use bars and cocktail lounge for correct calculation. show formula. FBC Mechanical 2023 5. Update equipment schedule to show current available equipment 6. Hood will need to be on a separate permit 7. Walk in cooler to be on separte permit 8. Hood exhaust fan need to extend beyond building to have clearance away from openings into building and combustible awning. (Can be part of the hood permit. Just an FYI)
PLUM HOLD 04/22/2025 05/06/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM ALL COMMENTS FROM FBC PLUMBING, FBC EXISTING BUILDING, AND FBC ACCESSIBILITY 2023. RESUBMITTED PLAN PAGES NEED TO BE CLOUDED AND MUST HAVE A REPONSE LETTER FROM THE ENGINEER SIGNED AND SEALED 1. Plan page P001. Update code year under Plumbing general notes. to 2023 2. Provide backflow device schedule. List various backflow devices, manufacturer, model and applicable design standard they must conform to for each device type. Section 608. Table 608.1. Backflow preventer required at hose-bibbs, janitor sink, ice-maker, and any other water utilizing appliance connected to the water system including any not shown in the plans (e.g. coffee maker or soda machine with direct water supply connection). 3. Provide plumbing supply riser diagram on separate plan page. 107.2.1 4. Provide sanitary riser diagram on separate plan page. .107.2.1 5. Revise minimum plumbing facilities table. Use Nightclub, bars, taverns in table assembly 403.1. Provide correct number of bathrooms per table. Label men and womans on plans. Based on potty parity in 403.1.3 you need 7 womens w.c. to 5 men
UD1 COMPLETE 04/22/2025 04/29/2025
Note: Released By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM
UD2 HOLD 04/22/2025 04/29/2025
Note: Held By: DAN LEMONCELLO - - 1) Please provide total number of seats for business, including existing. 2) Please provide menu and details of food items served 3) Please provide details if meals will be plated or baskets 4) A new calculation must be performed for Grease interceptor sizing, once I receive the above information. 5) A separate permit is required for new/added grease interceptors. 6) Contact Dan Lemoncello, Utility Pretreatment Inspector for questions at llemoncello@palmcoastgov.com or (386) 286-2011 7) Cue Note is currently connected to a 1050 gallon grease interceptor. With new sizing calculations, this could require increased capacity. **(there are (2) 1250 gallon grease interceptors in a series already in place, just outside the current interceptor that have never been used)
GAS COMPLETE 04/22/2025 04/28/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 10% (¤164.28) 05/18/2026
ADMINISTRATIVE - COMMERCIAL ¤75.00 05/18/2026
INSPECTION COMMERCIAL ¤1,295.00 05/18/2026
INSPECTION - FIRE COMMERCIAL ¤60.00 05/18/2026
PLAN REVIEW - COMMERCIAL ¤212.75 05/18/2026
SURCHARGE FS 533.721 ¤14.78 05/18/2026
SURCHARGE - FS 468.631 ¤22.18 05/18/2026
SITE PLAN 30 ¤30.00 05/18/2026
Fees Total Due: ¤0.00 Total Paid: ¤1,545.43