Permit #2025041137
Permit Details
Status: ISSUED
| Parcel Id: 07-11-31-1090-000C0-0000 |
| Block: 000C0 |
| Subdivision: 1228 - SOUTHWEST QUADRANT |
| Job Phone: 386-264-3189 |
| Location Address: 160 CYPRESS POINT PKWY |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 05/18/2026 |
| NOC: RECORDED |
| Applicant name: WILLIAM PIERCE STOUGHTON |
| Owner: Q BILLETTE, LLC |
|
Address 160 CYPRESS POINT PKWY PALM COAST, FL 32164 |
| Lot: 0000 |
| Contracted Stated Job Value: ¤185,000.00 |
| Job Description: Unit C111 & C 112 Remodel - CUE NOTE BILLIARD ROOM |
| Type: CN |
Contractor
STOUGHTON & DURAN CUSTOM HOMES LLC
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 1478 BUNNELL, FL 32110 |
CGC047560 (Exp: 08/31/2026) | 386-627-8993 | 866-576-9888 |
Sub Contractors
MOISES MERINO DIAZ
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3104 ORANOLE ROAD ORLANDO, FL 32810 |
CAC1820980 (Exp: 08/31/2026) | 407-225-3149 |
MARK JOHN LUTCZA
| Status | Location Address | State License Number | Phone |
| ACTIVE |
26 ROYAL LEAF LANE PALM COAST, FL 32164 |
EC13005145 (Exp: 08/31/2026) | 386-586-0770 |
JEFFREY TROY SABAKA
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2191 DEERWOOD ACRES DR ST AUGUSTINE, FL 32084 |
CFC1427439 (Exp: 08/31/2026) | 904-838-2218 | 904-819-0965 |
Inspection History
| Type | Request Date | Result | Inspector |
| PLUMBING 2ND ROUGH | |||
| PLUMBING FINAL | |||
| HVAC ROUGH | |||
| HVAC FINAL | |||
| ELECTRIC 2ND ROUGH | |||
| ELECTRIC FINAL | |||
| GAS ROUGH | |||
| GAS FINAL | |||
| LATH/BRICK/WATER BARRIER | |||
| LINTEL | |||
| FRAMING | |||
| FIREWALL FINAL | |||
| FIREWALL PENETRATIONS | |||
| FIREWALL DRYWALL NAILING | |||
| ABOVE CEILING | |||
| WALL SHEATHING | |||
| INSULATION | |||
| STOREFRONT | |||
| BUILDING FINAL | |||
| FIRE FINAL | |||
| U - UTILITY COMMERCIAL FINAL |
Review History
| Department | Status | Date In | Date Out |
| PLUM | COMPLETE | 05/15/2026 | 05/18/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| PLUM | HOLD | 05/07/2026 | 05/07/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM ALL COMMENTS FROM FBC PLUMBING, FBC EXISTING BUILDING, AND FBC ACCESSIBILITY 2023. RESUBMITTED PLAN PAGES NEED TO BE CLOUDED AND MUST HAVE A REPONSE LETTER FROM THE ENGINEER SIGNED AND SEALED 1. OK 2. OK 3. OK 4. OK REPEAT COMMENT: 5. Revise minimum plumbing facilities table. Use Nightclub, bars, taverns in table assembly 403.1. Provide correct number of bathrooms per table. Current occupant load for amont of bathrooms would be 240. | |||
| ELEC | COMPLETE | 05/07/2026 | 05/11/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 04/30/2026 | 05/05/2026 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit updated electrical plan | |||
| FI1 | COMPLETE | 04/30/2026 | 05/05/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| PLUM | HOLD | 04/30/2026 | 05/05/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM ALL COMMENTS FROM FBC PLUMBING, FBC EXISTING BUILDING, AND FBC ACCESSIBILITY 2023. RESUBMITTED PLAN PAGES NEED TO BE CLOUDED AND MUST HAVE A REPONSE LETTER FROM THE ENGINEER SIGNED AND SEALED 1. OK 2. OK 3. OK 4. OK REPEAT COMMENT: 5. Revise minimum plumbing facilities table. Use Nightclub, bars, taverns in table assembly 403.1. Provide correct number of bathrooms per table. Current occupant load for amont of bathrooms would be 240. | |||
| BLD | COMPLETE | 04/30/2026 | 05/05/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 04/30/2026 | 05/05/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 04/28/2026 | 04/28/2026 |
| Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM RENAME TO 1.PDF, 2.PDF, ... | |||
| ELEC | HOLD | 03/05/2026 | 03/06/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Spoke to contractor | |||
| FI1 | HOLD | 03/05/2026 | 03/06/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Spoke to contractor | |||
| MECH | HOLD | 03/05/2026 | 03/06/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Spoke to contractor | |||
| PLUM | HOLD | 03/05/2026 | 03/06/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Spoke to contractor | |||
| BLD | HOLD | 03/05/2026 | 03/06/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Spoke to contractor | |||
| MECH | HOLD | 03/03/2026 | 03/04/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM ALL COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING, FLORIDA BUILDING CODE-EXISTING BUILDING, FLORIDA BUILDING CODE-MECHANICAL AND FLORIDA BUILDING CODE -ENERGY CONSERVATION. RESUBMITTED PLAN PAGES NEED TO BE CLOUDED AND MUST HAVE A REPONSE LETTER FROM THE ENGINEER SIGNED AND SEALED NO REVIEW COMPLETED HVAC, REFRIGERATION AND HOOD SYSTEM INSTALLED UNDER PREVIOUS PERMIT WAS NEVER INSPECTED. THEY WILL NEED TO CONFORM TO 2023 FBC 1.ok REPEAT COMMENT: 2. Provide Heatload Calculation per C403.2.1 FBC Energy Conservation 2023 3. ok 4. ok REPEAT COMMENT: 5. Update equipment schedule to show current available equipment 6. ok 7. ok 8. ok NEW COMMENT: All plan sheets need to be uploaded separately and each sheet needs to have a verifiable digital signature | |||
| BLD | HOLD | 03/03/2026 | 03/04/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM NO REVIEW COMPLETED. All plan sheets need to be uploaded separately and have a verifiable digital signature | |||
| PLUM | HOLD | 03/03/2026 | 03/04/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM NO REVIEW COMPLETED ALL COMMENTS FROM FBC PLUMBING, FBC EXISTING BUILDING, AND FBC ACCESSIBILITY 2023. RESUBMITTED PLAN PAGES NEED TO BE CLOUDED AND MUST HAVE A REPONSE LETTER FROM THE ENGINEER SIGNED AND SEALED 1. OK 2. OK 3. OK 4. OK REPEAT COMMENT: 5. Revise minimum plumbing facilities table. Use Nightclub, bars, taverns in table assembly 403.1. Provide correct number of bathrooms per table. Label men and womans on plans. Based on potty parity in 403.1.3 you need 7 womens w.c. to 5 men ( NO ARCHITECTURAL LETTER OR PLANS UPLOADED) | |||
| ELEC | HOLD | 03/03/2026 | 03/03/2026 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. All outlets including 240 volt must be GFCI protected in all areas mentioned in NEC 2020 210.8 (B) 2. Kitchen is not existing and never was permitted. Needs to be included in your drawings. | |||
| FI1 | HOLD | 03/03/2026 | 03/03/2026 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit a life safety plan that includes travel distance to all exits, fire extinguishers, etc. 2. Kitchen was not permitted needs to be included in your plans. | |||
| BLD | HOLD | 02/23/2026 | 03/02/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM NEED TO UPLOAD NEW ARCHITECTURAL PLANS | |||
| ELEC | HOLD | 02/23/2026 | 03/03/2026 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. All outlets including 240 volt must be GFCI protected in all areas mentioned in NEC 2020 210.8 (B) 2. Kitchen is not existing and never was permitted. Needs to be included in your drawings. | |||
| FI1 | HOLD | 02/23/2026 | 03/03/2026 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit a life safety plan that includes travel distance to all exits, fire extinguishers, etc. 2. Kitchen was not permitted needs to be included in your plans. | |||
| MECH | HOLD | 02/23/2026 | 03/02/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM THIS THE CORRECT REVIEW. PREVIOUS HAD AN ERROR. ALL COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING, FLORIDA BUILDING CODE-EXISTING BUILDING, FLORIDA BUILDING CODE-MECHANICAL AND FLORIDA BUILDING CODE -ENERGY CONSERVATION. RESUBMITTED PLAN PAGES NEED TO BE CLOUDED AND MUST HAVE A REPONSE LETTER FROM THE ENGINEER SIGNED AND SEALED NO LETTER SUBMITTED HVAC, REFRIGERATION AND HOOD SYSTEM INSTALLED UNDER PREVIOUS PERMIT WAS NEVER INSPECTED. THEY WILL NEED TO CONFORM TO 2023 FBC 1.ok REPEAT COMMENT: 2. Provide Heatload Calculation per C403.2.1 FBC Energy Conservation 2023 3. ok 4. ok REPEAT COMMENT: 5. Update equipment schedule to show current available equipment 6. ok 7. ok 8. ok | |||
| UD2 | COMPLETE | 02/23/2026 | 02/23/2026 |
| Note: Released By: DAN LEMONCELLO - - | |||
| PLUM | HOLD | 02/23/2026 | 03/02/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM ALL COMMENTS FROM FBC PLUMBING, FBC EXISTING BUILDING, AND FBC ACCESSIBILITY 2023. RESUBMITTED PLAN PAGES NEED TO BE CLOUDED AND MUST HAVE A REPONSE LETTER FROM THE ENGINEER SIGNED AND SEALED 1. OK 2. OK 3. OK 4. OK REPEAT COMMENT: 5. Revise minimum plumbing facilities table. Use Nightclub, bars, taverns in table assembly 403.1. Provide correct number of bathrooms per table. Label men and womans on plans. Based on potty parity in 403.1.3 you need 7 womens w.c. to 5 men ( NO ARCHITECTURAL LETTER OR PLANS UPLOADED) | |||
| MECH | HOLD | 02/23/2026 | 03/02/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM ALL COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING, FLORIDA BUILDING CODE-EXISTING BUILDING, FLORIDA BUILDING CODE-MECHANICAL AND FLORIDA BUILDING CODE -ENERGY CONSERVATION. RESUBMITTED PLAN PAGES NEED TO BE CLOUDED AND MUST HAVE A REPONSE LETTER FROM THE ENGINEER SIGNED AND SEALED NO LETTER SUBMITTED HVAC, REFRIGERATION AND HOOD SYSTEM INSTALLED UNDER PREVIOUS PERMIT WAS NEVER INSPECTED. THEY WILL NEED TO CONFORM TO 2023 FBC REPEAT COMMENT: 1. Provide Energy Calculations per C407 FBC Energy Conservation 2023 REPEAT COMMENT: 2. Provide Heatload Calculation per C403.2.1 FBC Energy Conservation 2023 3. ok 4. ok REPEAT COMMENT: 5. Update equipment schedule to show current available equipment 6. ok 7. ok 8. ok | |||
| BLD | HOLD | 02/11/2026 | 02/23/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM NO REVIEW COMPLETED. PLAN PAGES NEED TO BE UPLOADED SEPARATELY NOT IN GROUPS COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE (FBC), FLORIDA BUILDING CODE-EXISTING BUILDING, FLORIDA BUILDING CODE-ACCESSIBILITY (FBCA), FLORIDA STATUTES (F.S.), FLORIDA ADMINISTRATIVE CODE (F.A.C.) AND AUTHORITY HAVING JURISDICTION (A.H.J.). 1. Plans need to reference FBC Building, FBC Existing Building and FBC Accessibility 2023 2. Provide code analysis. Show construction type, egress capacity and requirements, wind loads ,design loads, etc... 107.3.5 FBC Building 3. Provide accessible bar area, Show approach dimensions, counter height and knee and toe clearance 902.1-902.3/904.4/ 306 FBC Accessibility 2023 4. Provide construction details of stage and ramp. Include material type, spacing , attachment details, live and dead loads, etc...107.3.5 FBC Building 2023 5. Provide note or details showing accessible seating for booths 902.2, 902.3, 306 FCB Accessibility 2023 | |||
| UD2 | HOLD | 02/11/2026 | 02/11/2026 |
| Note: Held By: DAN LEMONCELLO - - 1) answer all the questions asked on previous HOLD from 5/6/2025. 2) grease interceptor sizing needs to be recalculated according to FBC 2023 formula. Could require a larger capacity for grease waste 3) For questions, contact Utility Wastewater Pretreatment Inspector Dan Lemoncello @ llemoncello@palmcoastgov.com or (386)286-2011. | |||
| FI1 | HOLD | 02/11/2026 | 02/23/2026 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM NO REVIEW COMPLETED. PLAN PAGES NEED TO BE UPLOADED SEPARATELY NOT IN GROUPS 1. Submit a life safety plan tht includes travel distanceto all exits, fire extiuguishers, etc. | |||
| ELEC | HOLD | 02/11/2026 | 02/23/2026 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM NO REVIEW COMPLETED. PLAN PAGES NEED TO BE UPLOADED SEPARATELY NOT IN GROUPS 1. All outlets including 240 volt must be GFCI protected in all areas mentioned in NEC 2020 210.8 (B) | |||
| MECH | HOLD | 02/11/2026 | 02/23/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM NO REVIEW COMPLETED. PLAN PAGES NEED TO BE UPLOADED SEPARATELY NOT IN GROUPS ALL COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING, FLORIDA BUILDING CODE-EXISTING BUILDING, FLORIDA BUILDING CODE-MECHANICAL AND FLORIDA BUILDING CODE -ENERGY CONSERVATION. RESUBMITTED PLAN PAGES NEED TO BE CLOUDED AND MUST HAVE A REPONSE LETTER FROM THE ENGINEER SIGNED AND SEALED 1. Provide Energy Calculations per C407 FBC Energy Conservation 2023 2. Provide Heatload Calculation per C403.2.1 FBC Energy Conservation 2023 3. Provide condensate termination details for walk in cooler/AC unit. Cannot run into sanitary sewer system per Palm Coast Municiple Code Section 49-104 (12) 4. Provide Ventilation calculation per Table 403.3.1.1 from 2023 code cycle. Use bars and cocktail lounge for correct calculation. show formula. FBC Mechanical 2023 5. Update equipment schedule to show current available equipment 6. Hood will need to be on a separate permit 7. Walk in cooler to be on separte permit 8. Hood exhaust fan need to extend beyond building to have clearance away from openings into building and combustible awning. (Can be part of the hood permit. Just an FYI) | |||
| PLUM | HOLD | 02/11/2026 | 02/23/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM NO REVIEW COMPLETED. PLAN PAGES NEED TO BE UPLOADED SEPARATELY NOT IN GROUPS ALL COMMENTS FROM FBC PLUMBING, FBC EXISTING BUILDING, AND FBC ACCESSIBILITY 2023. RESUBMITTED PLAN PAGES NEED TO BE CLOUDED AND MUST HAVE A REPONSE LETTER FROM THE ENGINEER SIGNED AND SEALED 1. Plan page P001. Update code year under Plumbing general notes. to 2023 2. Provide backflow device schedule. List various backflow devices, manufacturer, model and applicable design standard they must conform to for each device type. Section 608. Table 608.1. Backflow preventer required at hose-bibbs, janitor sink, ice-maker, and any other water utilizing appliance connected to the water system including any not shown in the plans (e.g. coffee maker or soda machine with direct water supply connection). 3. Provide plumbing supply riser diagram on separate plan page. 107.2.1 4. Provide sanitary riser diagram on separate plan page. .107.2.1 5. Revise minimum plumbing facilities table. Use Nightclub, bars, taverns in table assembly 403.1. Provide correct number of bathrooms per table. Label men and womans on plans. Based on potty parity in 403.1.3 you need 7 womens w.c. to 5 men | |||
| BLD | HOLD | 02/11/2026 | 02/23/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM NO REVIEW COMPLETED. PLAN PAGES NEED TO BE UPLOADED SEPARATELY NOT IN GROUPS | |||
| BADMIN | INFORMATION | 01/26/2026 | 01/26/2026 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM A 30 day extension is to be granted. There will not be any more extensions granted and this will be come a code enforcement case. The orginal permit expired quite some time ago. It has not been resolved. This permit was applied for in April and has already been extended once. | |||
| BLD | HOLD | 04/22/2025 | 05/06/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE (FBC), FLORIDA BUILDING CODE-EXISTING BUILDING, FLORIDA BUILDING CODE-ACCESSIBILITY (FBCA), FLORIDA STATUTES (F.S.), FLORIDA ADMINISTRATIVE CODE (F.A.C.) AND AUTHORITY HAVING JURISDICTION (A.H.J.). 1. Plans need to reference FBC Building, FBC Existing Building and FBC Accessibility 2023 2. Provide code analysis. Show construction type, egress capacity and requirements, wind loads ,design loads, etc... 107.3.5 FBC Building 3. Provide accessible bar area, Show approach dimensions, counter height and knee and toe clearance 902.1-902.3/904.4/ 306 FBC Accessibility 2023 4. Provide construction details of stage and ramp. Include material type, spacing , attachment details, live and dead loads, etc...107.3.5 FBC Building 2023 5. Provide note or details showing accessible seating for booths 902.2, 902.3, 306 FCB Accessibility 2023 | |||
| DSD | COMPLETE | 04/22/2025 | 04/25/2025 |
| Note: Released By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 04/22/2025 | 05/05/2025 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. All outlets including 240 volt must be GFCI protected in all areas mentioned in NEC 2020 210.8 (B) | |||
| FI1 | HOLD | 04/22/2025 | 05/05/2025 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit a life safety plan tht includes travel distanceto all exits, fire extiuguishers, etc. 2. FFPC 8th edition7.2.2.3.1.2 Each stair, platform, and landing, not including handrails and existing stairs, in buildings required in this Code to be of Type I or Type II construction shall be of noncombustible material throughout. | |||
| MECH | HOLD | 04/22/2025 | 05/06/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM ALL COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING, FLORIDA BUILDING CODE-EXISTING BUILDING, FLORIDA BUILDING CODE-MECHANICAL AND FLORIDA BUILDING CODE -ENERGY CONSERVATION. RESUBMITTED PLAN PAGES NEED TO BE CLOUDED AND MUST HAVE A REPONSE LETTER FROM THE ENGINEER SIGNED AND SEALED 1. Provide Energy Calculations per C407 FBC Energy Conservation 2023 2. Provide Heatload Calculation per C403.2.1 FBC Energy Conservation 2023 3. Provide condensate termination details for walk in cooler/AC unit. Cannot run into sanitary sewer system per Palm Coast Municiple Code Section 49-104 (12) 4. Provide Ventilation calculation per Table 403.3.1.1 from 2023 code cycle. Use bars and cocktail lounge for correct calculation. show formula. FBC Mechanical 2023 5. Update equipment schedule to show current available equipment 6. Hood will need to be on a separate permit 7. Walk in cooler to be on separte permit 8. Hood exhaust fan need to extend beyond building to have clearance away from openings into building and combustible awning. (Can be part of the hood permit. Just an FYI) | |||
| PLUM | HOLD | 04/22/2025 | 05/06/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM ALL COMMENTS FROM FBC PLUMBING, FBC EXISTING BUILDING, AND FBC ACCESSIBILITY 2023. RESUBMITTED PLAN PAGES NEED TO BE CLOUDED AND MUST HAVE A REPONSE LETTER FROM THE ENGINEER SIGNED AND SEALED 1. Plan page P001. Update code year under Plumbing general notes. to 2023 2. Provide backflow device schedule. List various backflow devices, manufacturer, model and applicable design standard they must conform to for each device type. Section 608. Table 608.1. Backflow preventer required at hose-bibbs, janitor sink, ice-maker, and any other water utilizing appliance connected to the water system including any not shown in the plans (e.g. coffee maker or soda machine with direct water supply connection). 3. Provide plumbing supply riser diagram on separate plan page. 107.2.1 4. Provide sanitary riser diagram on separate plan page. .107.2.1 5. Revise minimum plumbing facilities table. Use Nightclub, bars, taverns in table assembly 403.1. Provide correct number of bathrooms per table. Label men and womans on plans. Based on potty parity in 403.1.3 you need 7 womens w.c. to 5 men | |||
| UD1 | COMPLETE | 04/22/2025 | 04/29/2025 |
| Note: Released By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM | |||
| UD2 | HOLD | 04/22/2025 | 04/29/2025 |
| Note: Held By: DAN LEMONCELLO - - 1) Please provide total number of seats for business, including existing. 2) Please provide menu and details of food items served 3) Please provide details if meals will be plated or baskets 4) A new calculation must be performed for Grease interceptor sizing, once I receive the above information. 5) A separate permit is required for new/added grease interceptors. 6) Contact Dan Lemoncello, Utility Pretreatment Inspector for questions at llemoncello@palmcoastgov.com or (386) 286-2011 7) Cue Note is currently connected to a 1050 gallon grease interceptor. With new sizing calculations, this could require increased capacity. **(there are (2) 1250 gallon grease interceptors in a series already in place, just outside the current interceptor that have never been used) | |||
| GAS | COMPLETE | 04/22/2025 | 04/28/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 10% | (¤164.28) | 05/18/2026 |
| ADMINISTRATIVE - COMMERCIAL | ¤75.00 | 05/18/2026 |
| INSPECTION COMMERCIAL | ¤1,295.00 | 05/18/2026 |
| INSPECTION - FIRE COMMERCIAL | ¤60.00 | 05/18/2026 |
| PLAN REVIEW - COMMERCIAL | ¤212.75 | 05/18/2026 |
| SURCHARGE FS 533.721 | ¤14.78 | 05/18/2026 |
| SURCHARGE - FS 468.631 | ¤22.18 | 05/18/2026 |
| SITE PLAN 30 | ¤30.00 | 05/18/2026 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤1,545.43 |