I want to search for...

Permit #2025041277

Permit Details

Status: COED

Parcel Id: 07-11-31-7065-00320-0080
CONDITIONED SPACE: 1809 sqft
GARAGE: 406 sqft
OPENED PORCH (WITH ROOF) : 33 sqft
Total Square Footage: 2248 sqft
Block: 00320
Subdivision: -
Job Phone: 239-571-5325
Location Address: 22 KAYWOOD PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 05/14/2025
NOC: RECORDED
Applicant name: RYAN SCOTT DAVIS
Owner: SYNERGY HOMES LLC

Address

581 NW MERCANTILE PL

PORT SAINT LUCIE, FL 34986

Address

SUITE 106

PORT SAINT LUCIE, FL 34986

Lot: 0080
Contracted Stated Job Value: ¤200,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

SYNERGY HOMES, LLC
Status Location Address State License Number
ACTIVE

1 HARGROVE GRADE, SUITE B1

PALM COAST, FL 32137

CBC1254289 (Exp: 08/31/2026)

Sub Contractors

MICHAEL FRANK MORELLO
Status Location Address State License Number Phone Fax
ACTIVE

2 HARGROVE GRADE

PALM COAST, FL 32164

CAC1819466 (Exp: 08/31/2026) 386-445-5023 386-446-4614
HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 11/18/2025 FINAL APPROVED CVANSTRAHLEN
Note: 11/17/2025 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-electrical breakers for AH and AC do not match what mechanical equitment required #2-dish water is connected byut not working #3-Share bathroom , left sink pull for water restrainer is not working properly #4-MIssing weather stripping ( front door ) #5- not hot water on faucets 11/13/2025 - PREVIOUS INSPECTION NOTES
ROW - FINAL APRON (AFTER POUR) 11/18/2025 APPROVED FSLADISH
Note: 11/18/25 AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ______________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 11/14/25 I AM CONDUCTING THIS FIELD SURVEY AS A COURTESY. YOU ARE REQUIRED TO HAVE AN ADDRESS EASILY VISIBLE AND/OR A DOC BOX ON SITE. YOU WILL BE REQUIRED TO HAVE ADDRESS CLEARLY VISIBLE BEFORE ROW FINAL PASSAGE. THE ADDRESS MUST BE POSTED AND VISIBLE TO INSPECTORS Florida Building Code-;. Building Section 501.2 THE ADDRESS MUST BE POSTED AND VISIBLE TO INSPECTORS.  IF THE ADDRESS IS NOT VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS, AND A REINSPECTION FEE WILL BE ISSUED.  Florida Building Code-;. Building Section 501.2 . AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - STORMWATER FINAL 11/18/2025 APPROVED FSLADISH
Note: 11/18/25 AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 11/14/25 I AM CONDUCTING THIS FIELD SURVEY AS A COURTESY. YOU ARE REQUIRED TO HAVE AN ADDRESS EASILY VISIBLE AND/OR A DOC BOX ON SITE. YOU WILL BE REQUIRED TO HAVE ADDRESS CLEARLY VISIBLE BEFORE ROW FINAL PASSAGE. THE ADDRESS MUST BE POSTED AND VISIBLE TO INSPECTORS Florida Building Code-;. Building Section 501.2 THE ADDRESS MUST BE POSTED AND VISIBLE TO INSPECTORS.  IF THE ADDRESS IS NOT VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS, AND A REINSPECTION FEE WILL BE ISSUED.  Florida Building Code-;. Building Section 501.2 . AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
U -UTILITY RESIDENTIAL FINAL 11/18/2025 FINAL APPROVED BHAINES
Note: Inspector Notes from Inspection 9035 No IRR, No CC
BLD - BUILDING FINAL 11/17/2025 Disapproved - NO FEE CVANSTRAHLEN
Note: Please fix items before next inspection #1-electrical breakers for AH and AC do not match what mechanical equitment required #2-dish water is connected byut not working #3-Share bathroom , left sink pull for water restrainer is not working properly #4-MIssing weather stripping ( front door ) #5- not hot water on faucets 11/13/2025 - PREVIOUS INSPECTION NOTES
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/14/2025 APPROVED FSLADISH
ROW FIELD SURVEY /GRADING CERTIFICATION 11/14/2025 APPROVED - AS NOTED FSLADISH
Note: 11/14/25 I AM CONDUCTING THIS FIELD SURVEY AS A COURTESY. YOU ARE REQUIRED TO HAVE AN ADDRESS EASILY VISIBLE AND/OR A DOC BOX ON SITE. YOU WILL BE REQUIRED TO HAVE ADDRESS CLEARLY VISIBLE BEFORE ROW FINAL PASSAGE. THE ADDRESS MUST BE POSTED AND VISIBLE TO INSPECTORS Florida Building Code-;. Building Section 501.2 THE ADDRESS MUST BE POSTED AND VISIBLE TO INSPECTORS.  IF THE ADDRESS IS NOT VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS, AND A REINSPECTION FEE WILL BE ISSUED.  Florida Building Code-;. Building Section 501.2 . AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
BLD - BUILDING FINAL 11/13/2025 CANCELLED BY APPLICANT BTAYLOR
ROW- PRE-APRON (PRE-POUR) 10/31/2025 APPROVED FSLADISH
Note: 10/31/25 CULVERT PIPE IS WITHIN COPC SWALE DIAGRAM TOLERANCE AT THE TIME OF THIS INSPECTION. BUILDER REFER TO CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. . IF FIBERGLASS OPTION IS USED, BUILDER REQUIRED TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK SITE FOR ANY STANDING WATER. ALSO VERIFY PIPE ELEVATION HAS NOT CHANGED. NO EXPANSION JOINTS ALLOWED, THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. AT THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. New inspection due to canceled inspection 9/17/2025 - PREVIOUS INSPECTION NOTES 9/17/25 CULVERT PIPE IS OUT OF TOLERANCE TO THE SWALE PLAN DIAGRAM AT THE TIME OF THIS INSPECTION. POUR AREA IS STILL VERY WET AS WELL. ROADSIDE SWALE AND CULVERT SET WITHIN 0.10 Section 300.01 C(3) V-17 3) The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow, nor shall it be sloped more than 0.10 of a foot in thedirection of the drainage flow __________________________________________________________________________________________________________________________ 9/16/2025 - PREVIOUS INSPECTION NOTES 9/16/25 THIS SITE IS TOO WET AND SOFT TO CONDUCT A PREPOUR INSPECTION AT THIS TIME. SEE PHOTO FOR REFERENCE. __________________________________________________________________________________________________________________________ 9/8/2025 - PREVIOUS INSPECTION NOTES THIS IS NOT READY FOR INSPECTION. THERE ARE NO FORMS ON SITE AND THE CULVERT IS UNDER WATER AT THIS TIME OF THE INSPECTION 9:06AM
ROW- PRE-APRON (PRE-POUR) 09/26/2025 CANCELLED BY APPLICANT WEB
Note: 9/17/2025 - PREVIOUS INSPECTION NOTES 9/17/25 CULVERT PIPE IS OUT OF TOLERANCE TO THE SWALE PLAN DIAGRAM AT THE TIME OF THIS INSPECTION. POUR AREA IS STILL VERY WET AS WELL. ROADSIDE SWALE AND CULVERT SET WITHIN 0.10 Section 300.01 C(3) V-17 3) The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow, nor shall it be sloped more than 0.10 of a foot in thedirection of the drainage flow __________________________________________________________________________________________________________________________ 9/16/2025 - PREVIOUS INSPECTION NOTES 9/16/25 THIS SITE IS TOO WET AND SOFT TO CONDUCT A PREPOUR INSPECTION AT THIS TIME. SEE PHOTO FOR REFERENCE. __________________________________________________________________________________________________________________________ 9/8/2025 - PREVIOUS INSPECTION NOTES THIS IS NOT READY FOR INSPECTION. THERE ARE NO FORMS ON SITE AND THE CULVERT IS UNDER WATER AT THIS TIME OF THE INSPECTION 9:06AM
GRAVITY SEWER TEST 09/22/2025 APPROVED MGIBSON
SEWER TIE IN 09/22/2025 APPROVED MGIBSON
ELECTRIC - EARLY POWER 09/17/2025 APPROVED - AS NOTED BTAYLOR
Note: 9-17-25 1. Emailed FPL at 1:38.
ROW- PRE-APRON (PRE-POUR) 09/17/2025 Disapproved -FEE REQUIRED FSLADISH
Note: 9/17/25 CULVERT PIPE IS OUT OF TOLERANCE TO THE SWALE PLAN DIAGRAM AT THE TIME OF THIS INSPECTION. POUR AREA IS STILL VERY WET AS WELL. ROADSIDE SWALE AND CULVERT SET WITHIN 0.10 Section 300.01 C(3) V-17 3) The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow, nor shall it be sloped more than 0.10 of a foot in thedirection of the drainage flow __________________________________________________________________________________________________________________________ 9/16/2025 - PREVIOUS INSPECTION NOTES 9/16/25 THIS SITE IS TOO WET AND SOFT TO CONDUCT A PREPOUR INSPECTION AT THIS TIME. SEE PHOTO FOR REFERENCE. __________________________________________________________________________________________________________________________ 9/8/2025 - PREVIOUS INSPECTION NOTES THIS IS NOT READY FOR INSPECTION. THERE ARE NO FORMS ON SITE AND THE CULVERT IS UNDER WATER AT THIS TIME OF THE INSPECTION 9:06AM
ROW- PRE-APRON (PRE-POUR) 09/16/2025 Disapproved -FEE REQUIRED FSLADISH
Note: 9/16/25 THIS SITE IS TOO WET AND SOFT TO CONDUCT A PREPOUR INSPECTION AT THIS TIME. SEE PHOTO FOR REFERENCE. __________________________________________________________________________________________________________________________ 9/8/2025 - PREVIOUS INSPECTION NOTES THIS IS NOT READY FOR INSPECTION. THERE ARE NO FORMS ON SITE AND THE CULVERT IS UNDER WATER AT THIS TIME OF THE INSPECTION 9:06AM
ROW- PRE-APRON (PRE-POUR) 09/08/2025 Disapproved -FEE REQUIRED PFLANAGAN
Note: THIS IS NOT READY FOR INSPECTION. THERE ARE NO FORMS ON SITE AND THE CULVERT IS UNDER WATER AT THIS TIME OF THE INSPECTION 9:06AM
PEP TANK INSTALLATION REQUEST 09/08/2025 APPROVED CBOWERMASTER
INSULATION 08/29/2025 APPROVED BTAYLOR
Note: 8/28/2025 - PREVIOUS INSPECTION NOTES 8/28/25 Nothing has been completed. Insulation is not even all installed either at time of inspection Plumbing vent roof boot flashing need to be install prior to insulation. Note: 4th (now 5th) Request to Please move portable toilet from swale. FBC 3303.5 If not completed prior to next inspection, Inspection will not be approved. Inspector Notes from Inspection 2420 *** NOTES ADDED BY JSTEWART 8/25/2025 2:42:08 PM *** Plumbing vent roof boot flashing need to be install prior to insulation. Note: 4th Request to Please move portable toilet from swale. FBC 3303.5 If not completed prior to next inspection, Inspection will not be approved. 8/22/2025 - PREVIOUS INSPECTION NOTES 8/21/2025 - PREVIOUS INSPECTION NOTES 8/21/25: NOT READY! INCOMPLETE PLUMBING. 1). Please move portable toilet from swale. FBC 3303.5
LATH/BRICK/ WATER BARRIER 08/29/2025 APPROVED BTAYLOR
Note: 8/28/2025 - PREVIOUS INSPECTION NOTES 8/28/25 Nothing has been completed Plumbing vent roof boot flashing need to be install prior to insulation. Note: 4th (now 5th) Request to Please move portable toilet from swale. FBC 3303.5 If not completed prior to next inspection, Inspection will not be approved. Inspector Notes from Inspection 2420 *** NOTES ADDED BY JSTEWART 8/25/2025 2:42:08 PM *** Plumbing vent roof boot flashing need to be install prior to insulation. Note: 4th Request to Please move portable toilet from swale. FBC 3303.5 If not completed prior to next inspection, Inspection will not be approved. 8/22/2025 - PREVIOUS INSPECTION NOTES 8/21/2025 - PREVIOUS INSPECTION NOTES 8/21/25: NOT READY! INCOMPLETE PLUMBING. 1). Please move portable toilet from swale. FBC 3303.5
LATH/BRICK/ WATER BARRIER 08/28/2025 Disapproved - NO FEE MCONTRYMAN
Note: 8/28/25 Nothing has been completed Plumbing vent roof boot flashing need to be install prior to insulation. Note: 4th (now 5th) Request to Please move portable toilet from swale. FBC 3303.5 If not completed prior to next inspection, Inspection will not be approved. Inspector Notes from Inspection 2420 *** NOTES ADDED BY JSTEWART 8/25/2025 2:42:08 PM *** Plumbing vent roof boot flashing need to be install prior to insulation. Note: 4th Request to Please move portable toilet from swale. FBC 3303.5 If not completed prior to next inspection, Inspection will not be approved. 8/22/2025 - PREVIOUS INSPECTION NOTES 8/21/2025 - PREVIOUS INSPECTION NOTES 8/21/25: NOT READY! INCOMPLETE PLUMBING. 1). Please move portable toilet from swale. FBC 3303.5
INSULATION 08/28/2025 Disapproved -FEE REQUIRED MCONTRYMAN
Note: 8/28/25 Nothing has been completed. Insulation is not even all installed either at time of inspection Plumbing vent roof boot flashing need to be install prior to insulation. Note: 4th (now 5th) Request to Please move portable toilet from swale. FBC 3303.5 If not completed prior to next inspection, Inspection will not be approved. Inspector Notes from Inspection 2420 *** NOTES ADDED BY JSTEWART 8/25/2025 2:42:08 PM *** Plumbing vent roof boot flashing need to be install prior to insulation. Note: 4th Request to Please move portable toilet from swale. FBC 3303.5 If not completed prior to next inspection, Inspection will not be approved. 8/22/2025 - PREVIOUS INSPECTION NOTES 8/21/2025 - PREVIOUS INSPECTION NOTES 8/21/25: NOT READY! INCOMPLETE PLUMBING. 1). Please move portable toilet from swale. FBC 3303.5
ALL ROUGH 08/25/2025 APPROVED - AS NOTED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 8/25/2025 2:42:08 PM *** Plumbing vent roof boot flashing need to be install prior to insulation. Note: 4th Request to Please move portable toilet from swale. FBC 3303.5 If not completed prior to next inspection, Inspection will not be approved. 8/22/2025 - PREVIOUS INSPECTION NOTES 8/21/2025 - PREVIOUS INSPECTION NOTES 8/21/25: NOT READY! INCOMPLETE PLUMBING. 1). Please move portable toilet from swale. FBC 3303.5
ALL ROUGH 08/22/2025 CANCELLED BY APPLICANT KSANDOE
Note: 8/21/2025 - PREVIOUS INSPECTION NOTES 8/21/25: NOT READY! INCOMPLETE PLUMBING. 1). Please move portable toilet from swale. FBC 3303.5
LATH/BRICK/ WATER BARRIER 08/22/2025 Disapproved -FEE REQUIRED KSANDOE
Note: Not ready for inspection. No work completed
ALL ROUGH 08/21/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 8/21/2025 3:47:59 PM *** 8/21/25: NOT READY! INCOMPLETE PLUMBING. 1). Please move portable toilet from swale. FBC 3303.5
ROOF VALLEY & METAL 08/15/2025 APPROVED BTAYLOR
WALL SHEATHING 08/14/2025 CANCELLED BY INSPECTOR CVANSTRAHLEN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/14/2025 APPROVED - AS NOTED CVANSTRAHLEN
Note: Please fix item before next inspection #1-FBC 3303.5-SWALE CLEAR ( moved porta potty from swale )
U-CROSS CONNECTION 08/12/2025 APPROVED - AS NOTED BWRIGHT
Note: No IRR, No CC
TIE BEAM / LINTEL 08/05/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 8/5/2025 10:33:31 AM ***
MONOLITHIC SLAB 07/29/2025 APPROVED MCONTRYMAN
Note: 7/25/2025 - PREVIOUS INSPECTION NOTES 7-25-25 1. Footer by vent pipes does not have 3" of clearance between dirt and rebar. 2. Footer by ground wire and A/C chase needs to be cleaned out.
MONOLITHIC SLAB 07/25/2025 Disapproved - NO FEE BTAYLOR
Note: 7-25-25 1. Footer by vent pipes does not have 3" of clearance between dirt and rebar. 2. Footer by ground wire and A/C chase needs to be cleaned out.
PLUMBING 1ST ROUGH UNDERGROUND 07/23/2025 APPROVED CVANSTRAHLEN
Note: *** NOTES ADDED BY CVANSTRAHLEN 7/23/2025 12:33:09 PM *** FBC 3303.5-SWALE CLEAR ( please removed porta potty from swale )
FORMBOARD SURVEY (OFFICE USE ONLY) 07/21/2025 APPROVED - AS NOTED GBERTOLA
Note: Formboard Pass
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 07/17/2025 APPROVED JMUNSON
WATER METER INSTALLATION REQUEST 06/27/2025 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
SW1 COMPLETE 07/21/2025 07/21/2025
Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM Formboard Pass
ZON COMPLETE 07/21/2025 07/21/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BADMIN COMPLETE 07/17/2025 07/17/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SW1 COMPLETE 05/05/2025 05/08/2025
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ENGIN1 COMPLETE 05/05/2025 05/06/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ZON COMPLETE 05/05/2025 05/05/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
SWALE COMPLETE 04/25/2025 05/21/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
BADMIN COMPLETE 04/24/2025 04/29/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 04/24/2025 04/29/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 04/24/2025 04/30/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 04/24/2025 04/28/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/24/2025 04/25/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 04/24/2025 04/25/2025
LOCATE COMPLETE 04/24/2025 04/29/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 04/24/2025 04/28/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 04/24/2025 05/01/2025
Note: Held By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM No elevation depticted for the on benchmark on the PP. Please revise with elevation.
ZON COMPLETE 04/24/2025 04/25/2025
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 11/18/2025
REINSPECTION RESIDENTIAL ¤40.00 11/18/2025
REINSPECTION RESIDENTIAL ¤40.00 11/18/2025
SW ENG REINSPECTION 30 ¤30.00 11/18/2025
SW ENG REINSPECTION 30 ¤30.00 11/18/2025
SW ENG REINSPECTION 30 ¤30.00 11/18/2025
SW ENG - REVIEW 20 ¤20.00 05/14/2025
SW ENG RES REVIEW 200 ¤200.00 05/14/2025
WATER METER W/ TAP ¤2,326.93 05/14/2025
SEWER CREDIT (¤850.00) 05/14/2025
WASTEWATER PERM INSPECTION ¤80.00 05/14/2025
WASTEWATER PERM REVIEW ¤25.00 05/14/2025
SEWER CAPITAL FACILITY ¤3,496.74 05/14/2025
SEWER CAPITAL FACILITY ¤3,930.70 05/14/2025
WATER PERMIT REVIEW ¤25.00 05/14/2025
WATER MAIN EXTENSION IMPACT ¤854.40 05/14/2025
SITE PLAN 30 ¤30.00 05/14/2025
WATER- TURN ON ¤50.00 05/14/2025
ADJUSTMENT 10% (¤120.20) 05/14/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 05/14/2025
INSPECTION - RESIDENTIAL ¤913.00 05/14/2025
PLAN REVIEW - RESIDENTIAL ¤258.96 05/14/2025
FC IMPACT FEE EMS ¤62.00 05/14/2025
IMPACT FEE FIRE ¤434.51 05/14/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 05/14/2025
FC IMPACT FEE LIBRARY ¤268.00 05/14/2025
IMPACT FEE PARKS ¤1,828.01 05/14/2025
IMPACT FEE SCHOOL ¤5,450.00 05/14/2025
IMPACT FEE TRANSPORTATION ¤1,916.00 05/14/2025
PEP TANK INSTALL ¤756.74 05/14/2025
WASTEWATER MAIN EXTENSION IMPA ¤2,189.82 05/14/2025
SURCHARGE FS 533.721 ¤10.82 05/14/2025
SURCHARGE - FS 468.631 ¤16.23 05/14/2025
SW ENG - FOUNDATION SURVEY ¤20.00 05/14/2025
SW ENG INSPECTION 80 ¤80.00 05/14/2025
SW ENG PRE APRON ¤30.00 05/14/2025
Fees Total Due: ¤0.00 Total Paid: ¤24,760.66