I want to search for...

Permit #2025041282

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7013-00190-0370
Block: 00190
Subdivision: 7013 -
Location Address: 68 BRUNSWICK LN
Type: ME - MECHANICAL
Issue Date: 04/25/2025
NOC: Unknown
Applicant name: DANIEL GOULDNER
Owner: LAWRENCE MAXINE

Address

68 BRUNSWICK LANE

PALM COAST, FL 32137

Lot: 0370
Contracted Stated Job Value: ¤5,800.00
Job Description: HVAC CO LIKE FOR LIKE REF#2024061053
Type: CN
Original Permit #: 2024061053

Contractor

DUCTDIVERS LLC
Status Location Address State License Number
ACTIVE

400 OLD HAW CREEK RD

BUNNELL, FL 32110

CAC1818907 (Exp: 08/31/2026)

Inspection History

Type Request Date Result Inspector
HVAC FINAL 06/10/2025 FINAL APPROVED PKNAPIK
Note: Via virtual insection. All notes from previous inspection corrected. Kinked line was replaced in its entirety. 10/22/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 10/22/2024 12:18:23 PM *** 1. Please seal wall inside AHU stand at Liquid lines, exposed wall insulation and wall cavity. 2. Please seal the outside of AHU stand at liquid lines. 3. Please seal exterior wall Penetration at Liquid lines. 4. Please replace/repair suction line where kinked at exterior penetration over 50%. Note: Please do not seal the exterior penetration until inspection of kinked suction line is approved. please make repairs and have a tech onsite at time of inspection then tech can seal exterior penetration.
HVAC FINAL 10/22/2024 Disapproved - NO FEE JSTEWART
Note: *** NOTES ADDED BY JSTEWART 10/22/2024 12:18:23 PM *** 1. Please seal wall inside AHU stand at Liquid lines, exposed wall insulation and wall cavity. 2. Please seal the outside of AHU stand at liquid lines. 3. Please seal exterior wall Penetration at Liquid lines. 4. Please replace/repair suction line where kinked at exterior penetration over 50%. Note: Please do not seal the exterior penetration until inspection of kinked suction line is approved. please make repairs and have a tech onsite at time of inspection then tech can seal exterior penetration.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 10% (¤9.00) 04/25/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/25/2025
INSPECTION - MECHANICAL ¤60.00 04/25/2025
SURCHARGE FS 533.721 ¤2.00 04/25/2025
SURCHARGE - FS 468.631 ¤2.00 04/25/2025
Fees Total Due: ¤0.00 Total Paid: ¤85.00