I want to search for...
Permit #2025041282
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7013-00190-0370 |
| Block: 00190 |
| Subdivision: 7013 - |
| Location Address: 68 BRUNSWICK LN |
| Type: ME - MECHANICAL |
| Issue Date: 04/25/2025 |
| NOC: Unknown |
| Applicant name: DANIEL GOULDNER |
| Owner: LAWRENCE MAXINE |
|
Address 68 BRUNSWICK LANE PALM COAST, FL 32137 |
| Lot: 0370 |
| Contracted Stated Job Value: ¤5,800.00 |
| Job Description: HVAC CO LIKE FOR LIKE REF#2024061053 |
| Type: CN |
| Original Permit #: 2024061053 |
Contractor
DUCTDIVERS LLC
| Status | Location Address | State License Number |
| ACTIVE |
400 OLD HAW CREEK RD BUNNELL, FL 32110 |
CAC1818907 (Exp: 08/31/2026) |
Inspection History
| Type | Request Date | Result | Inspector |
| HVAC FINAL | 06/10/2025 | FINAL APPROVED | PKNAPIK |
| Note: Via virtual insection. All notes from previous inspection corrected. Kinked line was replaced in its entirety. 10/22/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 10/22/2024 12:18:23 PM *** 1. Please seal wall inside AHU stand at Liquid lines, exposed wall insulation and wall cavity. 2. Please seal the outside of AHU stand at liquid lines. 3. Please seal exterior wall Penetration at Liquid lines. 4. Please replace/repair suction line where kinked at exterior penetration over 50%. Note: Please do not seal the exterior penetration until inspection of kinked suction line is approved. please make repairs and have a tech onsite at time of inspection then tech can seal exterior penetration. | |||
| HVAC FINAL | 10/22/2024 | Disapproved - NO FEE | JSTEWART |
| Note: *** NOTES ADDED BY JSTEWART 10/22/2024 12:18:23 PM *** 1. Please seal wall inside AHU stand at Liquid lines, exposed wall insulation and wall cavity. 2. Please seal the outside of AHU stand at liquid lines. 3. Please seal exterior wall Penetration at Liquid lines. 4. Please replace/repair suction line where kinked at exterior penetration over 50%. Note: Please do not seal the exterior penetration until inspection of kinked suction line is approved. please make repairs and have a tech onsite at time of inspection then tech can seal exterior penetration. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 10% | (¤9.00) | 04/25/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 04/25/2025 |
| INSPECTION - MECHANICAL | ¤60.00 | 04/25/2025 |
| SURCHARGE FS 533.721 | ¤2.00 | 04/25/2025 |
| SURCHARGE - FS 468.631 | ¤2.00 | 04/25/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤85.00 |