Permit #2025041301
Permit Details
Status: COED
| Parcel Id: 07-11-31-7058-00600-0210 |
| CONDITIONED SPACE: 2526 sqft |
| GARAGE: 711 sqft |
| OPENED PORCH (WITH ROOF) : 368 sqft |
| Total Square Footage: 3605 sqft |
| Block: 00600 |
| Subdivision: - |
| Job Phone: 386-931-5741 |
| Location Address: 16 SELBORNE PATH |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 05/14/2025 |
| NOC: RECORDED |
| Applicant name: MICHAEL MARINO HANSEN |
| Owner: RBI HOMES |
|
Address PO BOX1347 FLAGLER BEACH, FL 32136 |
| Lot: 0210 |
| Contracted Stated Job Value: ¤341,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
RBI HOMES
| Status | Location Address | State License Number | Phone |
| ACTIVE |
PO BOX 1347 PALM COAST, FL 32137 |
RB29003877 (Exp: 08/31/2027) | 386-585-4097 |
Sub Contractors
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
ARTHUR J PASCOE
| Status | Location Address | State License Number | Phone |
| ACTIVE |
PO BOX 730007 ORMOND BEACH, FL 32174 |
EC13007168 (Exp: 08/31/2026) | 386-547-6439 |
GARY LLOYD SHEFFIELD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
PO BOX 912 PALM COAST, FL 32164 |
CAC1820539 (Exp: 08/31/2026) | 386-264-0550 |
MICHAEL MARINO HANSEN
| Status | Location Address | State License Number | Phone |
| ACTIVE |
10 WHITTINGTON PALM COAST, FL 32137 |
RC29027845 (Exp: 08/31/2027) | 386-585-4097 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 03/11/2026 | APPROVED | CVANSTRAHLEN |
| Note: 3/10/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection. #1-Electrical panel not mark as required ( number are of order , do not match order ) #2-Not water pressure on master bathroom right side faucet #3- Seal up sotfit , high voltage wire conduit penetration by meter/main FBC EC TABLE R402.4.1.1-5. Seal up soffit penetrations for electrical mast #4-Breakers need to be labeled in meter/main NEC 408.4 #5-Wall and ceiling penetrations in garage need to be sealed FBC 402.5.1.1 ( iron rod AH pan support ) #6-Porta-potty need to be removed -FBC [A]107.4 #7-FBC-R . 302.6 seal all garage penetration , wall and ceiling ( low voltage wire AHU Plenum conduit )( seal around plenum box #8-P2804.6.1-14-requires water heater temperature and pressure (T&P) relief valve discharge pipes to be made of approved materials (copper, CPVC, galvanized steel), maintain the same diameter as the valve outlet, and flow by gravity. The pipe must terminate 2–6 inches above the floor | |||
| BLD - BUILDING FINAL | 03/10/2026 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: Please fix items before next inspection. #1-Electrical panel not mark as required ( number are of order , do not match order ) #2-Not water pressure on master bathroom right side faucet #3- Seal up sotfit , high voltage wire conduit penetration by meter/main FBC EC TABLE R402.4.1.1-5. Seal up soffit penetrations for electrical mast #4-Breakers need to be labeled in meter/main NEC 408.4 #5-Wall and ceiling penetrations in garage need to be sealed FBC 402.5.1.1 ( iron rod AH pan support ) #6-Porta-potty need to be removed -FBC [A]107.4 #7-FBC-R . 302.6 seal all garage penetration , wall and ceiling ( low voltage wire AHU Plenum conduit )( seal around plenum box #8-P2804.6.1-14-requires water heater temperature and pressure (T&P) relief valve discharge pipes to be made of approved materials (copper, CPVC, galvanized steel), maintain the same diameter as the valve outlet, and flow by gravity. The pipe must terminate 2–6 inches above the floor | |||
| ROW - STORMWATER FINAL | 03/09/2026 | APPROVED | FSLADISH |
| Note: 3/9/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. _________________________________________________________________________________________________________________________________ 3/6/2026 - PREVIOUS INSPECTION NOTES 3/6/26 BUILDER IS REQUIRED TO REMOVE TEMPORARY CULVERT PIPE AND SOD ANY BARE DISTURBED AREAS UNDERNEATH PIPE ON THE RIGHT SIDE VACANT FRONT SWALE BEFORE ROW FINAL PASSAGE. SEE PHOTO FOR REFERENCE. _____________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 3/4/26 BUILDER WILL NEED TO RELOCATE TREE ON REAR LEFT SIDE AS IT IS IN THE REAR DRAINAGE CONVEYANCE AND MAINTAIN POSITIVE DRAINAGE FLOW. APPROVING THIS FIELD SURVEY AS A COURTESY SO BUILDER MAY MOVE FORWARD WITH INSPECTIONS BUT REQUIRED CORRECTION WILL NEED TO BE COMPLETED BEFORE ROW FINAL PASSAGE. _______________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 3/4/26 REAR SWALE DOES NOT HAVE REQUIRED 3 TENTHS BUT UPON WALKING PROPERTY DETERMINED DUE TO SITE SPECIFIC CONDITIONS DRAINAGE WORKS. APPROVING AS NOTED. BUILDER WILL NEED TO RELOCATE TREE ON REAR LEFT SIDE AS IT IS IN THE REAR DRAINAGE CONVEYANCE AND MAINTAIN POSITIVE DRAINAGE. | |||
| U -UTILITY RESIDENTIAL FINAL | 03/06/2026 | FINAL APPROVED | BWRIGHT |
| ROW - STORMWATER FINAL | 03/06/2026 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 3/6/26 BUILDER IS REQUIRED TO REMOVE TEMPORARY CULVERT PIPE AND SOD ANY BARE DISTURBED AREAS UNDERNEATH PIPE ON THE RIGHT SIDE VACANT FRONT SWALE BEFORE ROW FINAL PASSAGE. SEE PHOTO FOR REFERENCE. _____________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 3/4/26 BUILDER WILL NEED TO RELOCATE TREE ON REAR LEFT SIDE AS IT IS IN THE REAR DRAINAGE CONVEYANCE AND MAINTAIN POSITIVE DRAINAGE FLOW. APPROVING THIS FIELD SURVEY AS A COURTESY SO BUILDER MAY MOVE FORWARD WITH INSPECTIONS BUT REQUIRED CORRECTION WILL NEED TO BE COMPLETED BEFORE ROW FINAL PASSAGE. _______________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 3/4/26 REAR SWALE DOES NOT HAVE REQUIRED 3 TENTHS BUT UPON WALKING PROPERTY DETERMINED DUE TO SITE SPECIFIC CONDITIONS DRAINAGE WORKS. APPROVING AS NOTED. BUILDER WILL NEED TO RELOCATE TREE ON REAR LEFT SIDE AS IT IS IN THE REAR DRAINAGE CONVEYANCE AND MAINTAIN POSITIVE DRAINAGE. | |||
| ROW - FINAL APRON (AFTER POUR) | 03/06/2026 | APPROVED | FSLADISH |
| Note: 3/6/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ______________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 3/4/26 BUILDER WILL NEED TO RELOCATE TREE ON REAR LEFT SIDE AS IT IS IN THE REAR DRAINAGE CONVEYANCE AND MAINTAIN POSITIVE DRAINAGE FLOW. APPROVING THIS FIELD SURVEY AS A COURTESY SO BUILDER MAY MOVE FORWARD WITH INSPECTIONS BUT REQUIRED CORRECTION WILL NEED TO BE COMPLETED BEFORE ROW FINAL PASSAGE. _______________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 3/4/26 REAR SWALE DOES NOT HAVE REQUIRED 3 TENTHS BUT UPON WALKING PROPERTY DETERMINED DUE TO SITE SPECIFIC CONDITIONS DRAINAGE WORKS. APPROVING AS NOTED. BUILDER WILL NEED TO RELOCATE TREE ON REAR LEFT SIDE AS IT IS IN THE REAR DRAINAGE CONVEYANCE AND MAINTAIN POSITIVE DRAINAGE. | |||
| U-CROSS CONNECTION | 03/06/2026 | APPROVED | BWRIGHT |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 03/05/2026 | APPROVED - AS NOTED | FSLADISH |
| Note: 3/4/26 REAR SWALE DOES NOT HAVE REQUIRED 3 TENTHS BUT UPON WALKING PROPERTY DETERMINED DUE TO SITE SPECIFIC CONDITIONS DRAINAGE WORKS. APPROVING AS NOTED. BUILDER WILL NEED TO RELOCATE TREE ON REAR LEFT SIDE AS IT IS IN THE REAR DRAINAGE CONVEYANCE AND MAINTAIN POSITIVE DRAINAGE. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 03/05/2026 | APPROVED - AS NOTED | FSLADISH |
| Note: 3/4/26 BUILDER WILL NEED TO RELOCATE TREE ON REAR LEFT SIDE AS IT IS IN THE REAR DRAINAGE CONVEYANCE AND MAINTAIN POSITIVE DRAINAGE FLOW. APPROVING THIS FIELD SURVEY AS A COURTESY SO BUILDER MAY MOVE FORWARD WITH INSPECTIONS BUT REQUIRED CORRECTION WILL NEED TO BE COMPLETED BEFORE ROW FINAL PASSAGE. _______________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 3/4/26 REAR SWALE DOES NOT HAVE REQUIRED 3 TENTHS BUT UPON WALKING PROPERTY DETERMINED DUE TO SITE SPECIFIC CONDITIONS DRAINAGE WORKS. APPROVING AS NOTED. BUILDER WILL NEED TO RELOCATE TREE ON REAR LEFT SIDE AS IT IS IN THE REAR DRAINAGE CONVEYANCE AND MAINTAIN POSITIVE DRAINAGE. | |||
| ELECTRIC - EARLY POWER | 01/16/2026 | APPROVED | CVANSTRAHLEN |
| Note: 1/15/2026 - PREVIOUS INSPECTION NOTES 1/15/26 1. Need surge protection in Meter/Main NEC 230.67 2. Need address posted FBCR 319.1 | |||
| ELECTRIC - EARLY POWER | 01/15/2026 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 1/15/26 1. Need surge protection in Meter/Main NEC 230.67 2. Need address posted FBCR 319.1 | |||
| ROW- PRE-APRON (PRE-POUR) | 01/13/2026 | APPROVED | FSLADISH |
| Note: 1/13/26 PIPE INVERTS ARE GOOD AT THIS INSPECTION. BUILDER REFER TO CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. . IF FIBERGLASS OPTION IS USED, BUILDER REQUIRED TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK SITE FOR ANY STANDING WATER. ALSO VERIFY PIPE ELEVATION HAS NOT CHANGED. NO EXPANSION JOINTS ALLOWED, AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. Inspector Notes from Inspection 9470 JIM AND CONTRACTOR ON SITE FIXING ALL AREAS PASSING AS NOTED THAT THIS IS BEING WORKED ON AT THE TIME OF THE INSPECTION -------------------------------------------------------------------------------------- 9/8/25=I RECEIVED A COMPLAINT THAT THE BUILDER IS BLOCKING THE FRONT SWALE. PLEASE CHECK AND TAKE ANY NECESSARY ACTION TO FIX THE DRAINAGE. PER GBERTOLA 9/8/2025 - PREVIOUS INSPECTION NOTES STILL NEED TO DO THE FOLLOWING 1) NEED TO INSTALL SILT FENCE ACROSSED THE FRONT 2) DUE TO THE RAIN OVER WEEKEND THERE IS NOW SILT IN THE SWALE THAT WHY THE SILT FENCE ACROSSED THE FRONT IS REQUIRED. ------------------------------------------------------------------------ 9/5/2025 - PREVIOUS INSPECTION NOTES 9/5/25 YOU ARE REQUIRED TO CONTINUE THE SILT FENCE ACROSS THE FRONT OF PROPERTY ON BOTH SIDES OF DRIVEWAY CONSTRUCTION ENTRANCE. YOU NEED TO REPAIR/REST TO STANDARD SILT FENCE ON THE RIGHT SIDE PROPERTY LINE. WILL BE BACK FOR A COMPLIANCE REINSPECTION ON 9/8/25 SWALE OPEN AND 9/3/2025 - PREVIOUS INSPECTION NOTES 1) NEED TO OPEN ROAD SIDE SWALE SO WATER CAN FLOW TO OUTFALL. 2) NEED TO CLEAN ALL TRASH AND CONSTRUCTION DEBRIS AND PLACE IN DUMPSTER. 3) NEED TO INSTALL SILT FENCE ACROSSED THE FRONT SO ON SEDIMENT WILL WASH IN TO THE SWALE AGAIN. YOU WILL HAVE 5 DAYS TO CORRECT ALL ISSUES OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT. | |||
| SEWER TIE IN | 01/06/2026 | APPROVED | MCONTRYMAN |
| Note: 12/30/2025 - PREVIOUS INSPECTION NOTES 12-30-25 1. Hole is filled in can not see connection. | |||
| GRAVITY SEWER TEST | 01/06/2026 | APPROVED | MCONTRYMAN |
| Note: 12/30/2025 - PREVIOUS INSPECTION NOTES 12-30-25 1. No water in test pipe. | |||
| SEWER TIE IN | 12/30/2025 | Disapproved - NO FEE | BTAYLOR |
| Note: 12-30-25 1. Hole is filled in can not see connection. | |||
| GRAVITY SEWER TEST | 12/30/2025 | Disapproved - NO FEE | BTAYLOR |
| Note: 12-30-25 1. No water in test pipe. | |||
| LATH/BRICK/ WATER BARRIER | 12/02/2025 | APPROVED | BTAYLOR |
| Note: 12/1/2025 - PREVIOUS INSPECTION NOTES 12-1-25 1. Outdoor shower area needs to have lath over it. | |||
| LATH/BRICK/ WATER BARRIER | 12/01/2025 | Disapproved - NO FEE | BTAYLOR |
| Note: 12-1-25 1. Outdoor shower area needs to have lath over it. | |||
| INSULATION | 11/20/2025 | APPROVED | BTAYLOR |
| Note: 11/18/2025 - PREVIOUS INSPECTION NOTES 11/18/25 1. Missing fire foam in wire areas in laundry room 2. Missing block foam board around SGD 3. Missing foam sealeant around SGD 4. Front right bath fan vent was moved and the old hole in sheathing needs to be sealed up 5. Where bath fan vent was moved, it is just stubbed through the roof with no vent connector. The old vent connector is still in place as well 6. All holes in garage need to be sealed Inspector Notes from Inspection 2420 Please fix items before next inspection #1-Please have a legible print of the E-cals duct work layout , showing size of duct , rooms | |||
| INSULATION | 11/18/2025 | Disapproved -FEE REQUIRED | MCONTRYMAN |
| Note: 11/18/25 1. Missing fire foam in wire areas in laundry room 2. Missing block foam board around SGD 3. Missing foam sealeant around SGD 4. Front right bath fan vent was moved and the old hole in sheathing needs to be sealed up 5. Where bath fan vent was moved, it is just stubbed through the roof with no vent connector. The old vent connector is still in place as well 6. All holes in garage need to be sealed Inspector Notes from Inspection 2420 Please fix items before next inspection #1-Please have a legible print of the E-cals duct work layout , showing size of duct , rooms | |||
| ALL ROUGH | 11/12/2025 | APPROVED - AS NOTED | CVANSTRAHLEN |
| Note: Please fix items before next inspection #1-Please have a legible print of the E-cals duct work layout , showing size of duct , rooms | |||
| ROOF VALLEY & METAL | 10/15/2025 | APPROVED | BTAYLOR |
| Note: 9/30/2025 - PREVIOUS INSPECTION NOTES 9-30-25 1. Drip edge is not installed properly on the left side of the garage due to facia board not being cut. | |||
| ROOF VALLEY & METAL | 09/30/2025 | Disapproved - NO FEE | BTAYLOR |
| Note: 9-30-25 1. Drip edge is not installed properly on the left side of the garage due to facia board not being cut. | |||
| WALL SHEATHING | 09/22/2025 | APPROVED | BTAYLOR |
| Note: Inspector Notes from Inspection 2460 9/19/25 1. Missing HTT4/MGT at top of beam to truss in Bedroom 4, per framing plan | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/19/2025 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 9/19/25 1. Missing HTT4/MGT at top of beam to truss in Bedroom 4, per framing plan | |||
| ROW - DRAINAGE | 09/09/2025 | APPROVED - AS NOTED | PFLANAGAN |
| Note: JIM AND CONTRACTOR ON SITE FIXING ALL AREAS PASSING AS NOTED THAT THIS IS BEING WORKED ON AT THE TIME OF THE INSPECTION -------------------------------------------------------------------------------------- 9/8/25=I RECEIVED A COMPLAINT THAT THE BUILDER IS BLOCKING THE FRONT SWALE. PLEASE CHECK AND TAKE ANY NECESSARY ACTION TO FIX THE DRAINAGE. PER GBERTOLA 9/8/2025 - PREVIOUS INSPECTION NOTES STILL NEED TO DO THE FOLLOWING 1) NEED TO INSTALL SILT FENCE ACROSSED THE FRONT 2) DUE TO THE RAIN OVER WEEKEND THERE IS NOW SILT IN THE SWALE THAT WHY THE SILT FENCE ACROSSED THE FRONT IS REQUIRED. ------------------------------------------------------------------------ 9/5/2025 - PREVIOUS INSPECTION NOTES 9/5/25 YOU ARE REQUIRED TO CONTINUE THE SILT FENCE ACROSS THE FRONT OF PROPERTY ON BOTH SIDES OF DRIVEWAY CONSTRUCTION ENTRANCE. YOU NEED TO REPAIR/REST TO STANDARD SILT FENCE ON THE RIGHT SIDE PROPERTY LINE. WILL BE BACK FOR A COMPLIANCE REINSPECTION ON 9/8/25 SWALE OPEN AND 9/3/2025 - PREVIOUS INSPECTION NOTES 1) NEED TO OPEN ROAD SIDE SWALE SO WATER CAN FLOW TO OUTFALL. 2) NEED TO CLEAN ALL TRASH AND CONSTRUCTION DEBRIS AND PLACE IN DUMPSTER. 3) NEED TO INSTALL SILT FENCE ACROSSED THE FRONT SO ON SEDIMENT WILL WASH IN TO THE SWALE AGAIN. YOU WILL HAVE 5 DAYS TO CORRECT ALL ISSUES OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT. | |||
| ROW - DRAINAGE | 09/08/2025 | Disapproved - NO FEE | FSLADISH |
| Note: 9/5/25 YOU ARE REQUIRED TO CONTINUE THE SILT FENCE ACROSS THE FRONT OF PROPERTY ON BOTH SIDES OF DRIVEWAY CONSTRUCTION ENTRANCE. YOU NEED TO REPAIR/REST TO STANDARD SILT FENCE ON THE RIGHT SIDE PROPERTY LINE. WILL BE BACK FOR A COMPLIANCE REINSPECTION ON 9/8/25 SWALE OPEN AND 9/3/2025 - PREVIOUS INSPECTION NOTES 1) NEED TO OPEN ROAD SIDE SWALE SO WATER CAN FLOW TO OUTFALL. 2) NEED TO CLEAN ALL TRASH AND CONSTRUCTION DEBRIS AND PLACE IN DUMPSTER. 3) NEED TO INSTALL SILT FENCE ACROSSED THE FRONT SO ON SEDIMENT WILL WASH IN TO THE SWALE AGAIN. YOU WILL HAVE 5 DAYS TO CORRECT ALL ISSUES OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT. | |||
| ROW - DRAINAGE | 09/08/2025 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: STILL NEED TO DO THE FOLLOWING 1) NEED TO INSTALL SILT FENCE ACROSSED THE FRONT 2) DUE TO THE RAIN OVER WEEKEND THERE IS NOW SILT IN THE SWALE THAT WHY THE SILT FENCE ACROSSED THE FRONT IS REQUIRED. ------------------------------------------------------------------------ 9/5/2025 - PREVIOUS INSPECTION NOTES 9/5/25 YOU ARE REQUIRED TO CONTINUE THE SILT FENCE ACROSS THE FRONT OF PROPERTY ON BOTH SIDES OF DRIVEWAY CONSTRUCTION ENTRANCE. YOU NEED TO REPAIR/REST TO STANDARD SILT FENCE ON THE RIGHT SIDE PROPERTY LINE. WILL BE BACK FOR A COMPLIANCE REINSPECTION ON 9/8/25 SWALE OPEN AND 9/3/2025 - PREVIOUS INSPECTION NOTES 1) NEED TO OPEN ROAD SIDE SWALE SO WATER CAN FLOW TO OUTFALL. 2) NEED TO CLEAN ALL TRASH AND CONSTRUCTION DEBRIS AND PLACE IN DUMPSTER. 3) NEED TO INSTALL SILT FENCE ACROSSED THE FRONT SO ON SEDIMENT WILL WASH IN TO THE SWALE AGAIN. YOU WILL HAVE 5 DAYS TO CORRECT ALL ISSUES OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT. | |||
| ROW - DRAINAGE | 09/03/2025 | Disapproved - NO FEE | PFLANAGAN |
| Note: 1) NEED TO OPEN ROAD SIDE SWALE SO WATER CAN FLOW TO OUTFALL. 2) NEED TO CLEAN ALL TRASH AND CONSTRUCTION DEBRIS AND PLACE IN DUMPSTER. 3) NEED TO INSTALL SILT FENCE ACROSSED THE FRONT SO ON SEDIMENT WILL WASH IN TO THE SWALE AGAIN. YOU WILL HAVE 5 DAYS TO CORRECT ALL ISSUES OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT. | |||
| TIE BEAM / LINTEL | 08/22/2025 | APPROVED | KSANDOE |
| Note: 8/21/2025 - PREVIOUS INSPECTION NOTES 8/21/25 1. Multiple window sills exceed mortar joint thickness (highlighted on plans) FBCR 606.3.1 2. Bed joints of bottom row of some blocks need to be tuck pointed (some highlighted on plans) 3. Right side window sill needs to be cleaned up of mortar and the slab chipped out to be flush (highlighted on plans) 4. Entry wall to house has several blocks that exceed mortar joint spacing FBCR 606.3.1 | |||
| TIE BEAM / LINTEL | 08/21/2025 | Disapproved -FEE REQUIRED | MCONTRYMAN |
| Note: 8/21/25 1. Multiple window sills exceed mortar joint thickness (highlighted on plans) FBCR 606.3.1 2. Bed joints of bottom row of some blocks need to be tuck pointed (some highlighted on plans) 3. Right side window sill needs to be cleaned up of mortar and the slab chipped out to be flush (highlighted on plans) 4. Entry wall to house has several blocks that exceed mortar joint spacing FBCR 606.3.1 | |||
| MONOLITHIC SLAB | 08/06/2025 | APPROVED | BTAYLOR |
| Note: 8/5/2025 - PREVIOUS INSPECTION NOTES PLEASE FIX ITEM BEFORE NEXT INSPECTION #1-FBC 3303.5-SWALE CLEAR ( MOVED PORTA POTTY ) #2-FBCR 318-TERMITE TREATMENT OR NOTICE OF INTENT FOR BORACARE #3-FBC R404.1.3.3.7.4 -REBAR NEEDS CLEARANCE FROM SOIL ( IN SOME AREAS WALL CAVE IN TO FOOTING ) | |||
| MONOLITHIC SLAB | 08/05/2025 | Disapproved - NO FEE | CVANSTRAHLEN |
| Note: PLEASE FIX ITEM BEFORE NEXT INSPECTION #1-FBC 3303.5-SWALE CLEAR ( MOVED PORTA POTTY ) #2-FBCR 318-TERMITE TREATMENT OR NOTICE OF INTENT FOR BORACARE #3-FBC R404.1.3.3.7.4 -REBAR NEEDS CLEARANCE FROM SOIL ( IN SOME AREAS WALL CAVE IN TO FOOTING ) | |||
| FORMBOARD SURVEY (OFFICE USE ONLY) | 07/23/2025 | APPROVED | RRICKS |
| PLUMBING 1ST ROUGH UNDERGROUND | 07/16/2025 | APPROVED | JSTEWART |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 07/02/2025 | APPROVED | JMUNSON |
| WATER METER INSTALLATION REQUEST | 06/26/2025 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 03/03/2026 | 03/04/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 03/03/2026 | 03/04/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 03/03/2026 | 03/04/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/03/2026 | 03/04/2026 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Zoning does not approve pools on house permits. | |||
| BLD | COMPLETE | 08/14/2025 | 08/19/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 08/13/2025 | 08/14/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/13/2025 | 08/13/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 07/23/2025 | 07/23/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/23/2025 | 07/23/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 07/16/2025 | 07/23/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 07/16/2025 | 07/16/2025 |
| Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM SITE PLAN/FORMBOARD SURVEYS CAN NOT BE SUBMITTED SIMULTANEOUSLY FOR REVIEW | |||
| SW1 | COMPLETE | 07/16/2025 | 07/23/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/16/2025 | 07/16/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ENGIN1 | HOLD | 07/14/2025 | 07/15/2025 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM The dimensions on the left side of the home does not match with the site plan. Please formboard survey to match site plan or submit a revised site plan for approval. | |||
| ZON | COMPLETE | 07/14/2025 | 07/14/2025 |
| Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 07/01/2025 | 07/02/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 05/07/2025 | 05/07/2025 |
| Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM REMOVE 'REVISED' FROM FILE NAME. | |||
| BLD | COMPLETE | 05/07/2025 | 05/12/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BADMIN | HOLD | 04/24/2025 | 04/30/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Truss plan packet cover sheet or first page needs include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal) | |||
| BLD | HOLD | 04/24/2025 | 04/30/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. Design criteria need to reference 2023 building code. 2. No soil bearing pressure reference for foundation in plans. | |||
| CUSVC | COMPLETE | 04/24/2025 | 04/29/2025 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 04/24/2025 | 04/28/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 04/24/2025 | 04/24/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 04/24/2025 | 04/25/2025 |
| LOCATE | COMPLETE | 04/24/2025 | 04/24/2025 |
| Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 04/24/2025 | 04/28/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 04/24/2025 | 05/01/2025 |
| Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/24/2025 | 04/25/2025 |
| Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 04/24/2025 | 05/12/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 03/10/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/10/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/10/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/10/2026 |
| CONTRACTOR CHANGE | ¤20.00 | 03/10/2026 |
| RSI REINSPECTION 1 | ¤35.00 | 03/10/2026 |
| SW ENG - INSPECTION 20 | ¤20.00 | 03/10/2026 |
| SW ENG - INSPECTION 20 | ¤20.00 | 03/10/2026 |
| SW ENG - INSPECTION 20 | ¤20.00 | 03/10/2026 |
| SW ENG - INSPECTION 20 | ¤20.00 | 03/10/2026 |
| SW ENG INSPECTION 80 | ¤80.00 | 05/14/2025 |
| SW ENG PRE APRON | ¤30.00 | 05/14/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 05/14/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 05/14/2025 |
| WATER METER W/ TAP | ¤2,326.93 | 05/14/2025 |
| SEWER CREDIT | (¤860.00) | 05/14/2025 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 05/14/2025 |
| WASTEWATER PERM REVIEW | ¤25.00 | 05/14/2025 |
| SEWER CAPITAL FACILITY | ¤3,930.70 | 05/14/2025 |
| WATER CAPITAL FACILITY FEE | ¤3,496.74 | 05/14/2025 |
| WATER PERMIT INSPECTION | ¤40.00 | 05/14/2025 |
| WATER PERMIT REVIEW | ¤25.00 | 05/14/2025 |
| WATER MAIN EXTENSION IMPACT | ¤854.40 | 05/14/2025 |
| SITE PLAN 30 | ¤30.00 | 05/14/2025 |
| WASTEWATER MAIN EXTENSION IMPA | ¤2,189.82 | 05/14/2025 |
| SURCHARGE FS 533.721 | ¤15.93 | 05/14/2025 |
| SURCHARGE - FS 468.631 | ¤23.90 | 05/14/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 05/14/2025 |
| WATER-METER | ¤965.03 | 05/14/2025 |
| WATER- TURN ON | ¤50.00 | 05/14/2025 |
| WATER- TURN ON | ¤50.00 | 05/14/2025 |
| ADJUSTMENT 10% | (¤177.03) | 05/14/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 05/14/2025 |
| INSPECTION - RESIDENTIAL | ¤1,355.75 | 05/14/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤384.54 | 05/14/2025 |
| FC IMPACT FEE EMS | ¤62.00 | 05/14/2025 |
| IMPACT FEE FIRE | ¤434.51 | 05/14/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 05/14/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 05/14/2025 |
| IMPACT FEE PARKS | ¤1,828.01 | 05/14/2025 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 05/14/2025 |
| IMPACT FEE TRANSPORTATION | ¤1,916.00 | 05/14/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤25,650.73 |