Permit #2025050064

Permit Details

Status: COED

Parcel Id: 07-11-31-7032-00320-0150
CONDITIONED SPACE: 2400 sqft
GARAGE: 566 sqft
OPENED PORCH (WITH ROOF) : 350 sqft
Total Square Footage: 3316 sqft
Block: 00320
Subdivision: 7032 -
Job Phone: 386-283-2035
Location Address: 21 ROSEPETAL LN
Type: DU - DUPLEX
Issue Date: 06/05/2025
NOC: RECORDED
Applicant name: OLEG BELINSKIY
Owner: FLORIDAS BEST BUILDERS INC

Address

19 PINE CIRCLE DR

PALM COAST, FL 32164

Lot: 0150
Contracted Stated Job Value: ¤350,000.00
Job Description: DUPLEX
Type: CN

Contractor

FLORIDAS BEST BUILDERS INC
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE

PALM COAST, FL 32164

CBC1264760 (Exp: 08/31/2026) 386-283-2035

Sub Contractors

OLEG BELINSKIY
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE19

PALM COAST, FL 32167

CCC1325974 (Exp: 08/31/2026) 386-263-7906
TIMUR ISPARYAN
Status Location Address State License Number Phone Fax
ACTIVE

3665 SPRINK PARK ROAD

JACKSONVILLE , FL 32207

CMC1249968 (Exp: 08/31/2026) 904-245-1818 904-337-1910
SERGEY A VORONIN
Status Location Address State License Number Phone
ACTIVE

7631 SEVERN

JACKSONVILLE, FL 32224

EC13011326 (Exp: 08/31/2026) 360-798-2819
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 01/12/2026 APPROVED CVANSTRAHLEN
Note: 1/6/2026 - PREVIOUS INSPECTION NOTES Inspection was completed on 01/05/26 Please fix items before next inspection #1-Seal open slot on main mater panel for A & B side #2-Seal sotfit penetration on main meter panel conduit #3-MIssing light bolb on attic on A & B side #4-Seal dryer box framing bottom trim ,( letf side ) #5-FBC [A] 107.4-MECHANICAL EQUIPMENT DOES NOT MATCH ENERGY CALCS ( AH Unit )for A & B sides #6-Insulation certificated need company name , signature and date #7-FBCR 318-TERMITE TREATMENT OR NOTICE OF INTENT FOR BORACARE Code for lock box - 1980
ROW - FINAL INSPECTION 01/12/2026 APPROVED FSLADISH
Note: 1/12/25 REQUIRED CORRECTIONS COMPLETED AT THE TIME OF THIS INSPECTION. . AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ________________________________________________________________________________________________________________________________ 1/6/2026 - PREVIOUS INSPECTION NOTES 1/6/26 DUE TO THE ENTIRE COPC CD PLUS SYSTEM BEING DOWN YESTERDAY AND SPEAKING WITH CM ABOUT REQUIRED CORRECTIONS NEEDED, I AM DISAPPROVING THIS INSPECTION WITHOUT A FEE AS IT WAS ALREADY IN THE SYSTEM PREVIOUS TO THE OUTAGE AND MEETING ON SITE. BUILDER REQUIRED TO REGLUE AND RESET PAVER ON LEFT SIDE DRIVEWAY APRON WING AT ROAD EDGE AND CLEAN ALL DIRT AND SEDIMENT OUT OF CULVERT PIPE, ESPECIALLY RIGHT SIDE BEFORE ROW FINAL PASSAGE. PHOTO FOR REFERENCE.
U -UTILITY RESIDENTIAL FINAL 01/05/2026 FINAL APPROVED BHAINES
ROW - FINAL INSPECTION 01/05/2026 Disapproved - NO FEE FSLADISH
Note: 1/6/26 DUE TO THE ENTIRE COPC CD PLUS SYSTEM BEING DOWN YESTERDAY AND SPEAKING WITH CM ABOUT REQUIRED CORRECTIONS NEEDED, I AM DISAPPROVING THIS INSPECTION WITHOUT A FEE AS IT WAS ALREADY IN THE SYSTEM PREVIOUS TO THE OUTAGE AND MEETING ON SITE. BUILDER REQUIRED TO REGLUE AND RESET PAVER ON LEFT SIDE DRIVEWAY APRON WING AT ROAD EDGE AND CLEAN ALL DIRT AND SEDIMENT OUT OF CULVERT PIPE, ESPECIALLY RIGHT SIDE BEFORE ROW FINAL PASSAGE. PHOTO FOR REFERENCE.
U-CROSS CONNECTION 01/05/2026 APPROVED - AS NOTED BHAINES
Note: No CC, No IRR
BLD - BUILDING FINAL 01/05/2026 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Inspection was completed on 01/05/26 Please fix items before next inspection #1-Seal open slot on main mater panel for A & B side #2-Seal sotfit penetration on main meter panel conduit #3-MIssing light bolb on attic on A & B side #4-Seal dryer box framing bottom trim ,( letf side ) #5-FBC [A] 107.4-MECHANICAL EQUIPMENT DOES NOT MATCH ENERGY CALCS ( AH Unit )for A & B sides #6-Insulation certificated need company name , signature and date #7-FBCR 318-TERMITE TREATMENT OR NOTICE OF INTENT FOR BORACARE Code for lock box - 1980
ROW - FINAL APRON (AFTER POUR) 01/05/2026 APPROVED - AS NOTED FSLADISH
Note: 1/6/26 I AM APPROVING THIS INSPECTION AS NOTED THAT YOU HAVE A LOOSE PAVER ON THE LEFT SIDE DRIVEWAY APRON THAT NEEDS TO BE REGLUED AND SET. I WILL HOLD IT UP ON THE ROW FINAL INSPECTION.
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/26/2025 APPROVED TPOLACEK
Note: 11/14/2025 - PREVIOUS INSPECTION NOTES 11-14-25 TPOLACEK** FINAL SURVEY INDICATES THE CULVERT IS PITCHED AGAINST THE FLOW BY .04 PLEASE HAVE CULVERT ELEVATION RESHOT TO CONFIRM
ROW FIELD SURVEY /GRADING CERTIFICATION 11/26/2025 APPROVED - AS NOTED TPOLACEK
Note: 11-26-25 TPOLACEK*** BEFORE ROW FINAL WILL BE APPROVED THERE IS TRASH BEHIND PROPERTY THAT MUST BE REMOVED. APPROVING FIELD AS NOTED Lot Grading Permit Requirements (Improved Properties) Sec 300.03 F4-A / V-22 Sec 300.03 F4-The Stormwater Final Inspection will include visual inspection of the site and adjacent properties for debris, proper clean up and repair to damaged terrain. Bare earth on the site or surrounding properties must be sodded, or seeded with pine straw cover, to prevent soil erosion. Bare earth and damage to any City roadside swales, drainage ditches, canals or other drainage conveyances must be graded to the proper elevation and sodded to prevent soil erosion. Road damage in the area of construction is also attributable to the Permittee, unless a preconstruction inspection has previously documented the damage 1 Road Damage must be seen before construction starts Sec 300.01 E2/ Sec 300.03 F1 Sec 300.01 E2 A pre-lot clearing inspection for road damage may be requested, if necessary, by calling inspector for you area. If an inspection has not been requested the builder will be responsible for all road damage and debris at the time of the final inspection.
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/14/2025 Disapproved - NO FEE TPOLACEK
Note: 11-14-25 TPOLACEK** FINAL SURVEY INDICATES THE CULVERT IS PITCHED AGAINST THE FLOW BY .04 PLEASE HAVE CULVERT ELEVATION RESHOT TO CONFIRM
ELECTRIC - EARLY POWER 11/06/2025 APPROVED CVANSTRAHLEN
Note: 11/5/2025 - PREVIOUS INSPECTION NOTES House is locked. Need access for inspection FRC110.1
ELECTRIC - EARLY POWER 11/05/2025 Disapproved -FEE REQUIRED KSANDOE
Note: House is locked. Need access for inspection FRC110.1
ROW- PRE-APRON (PRE-POUR) 10/21/2025 APPROVED TPOLACEK
Note: 10-21-25 POLACEK*** READY TO LAY PAVERS, AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 10/17/2025 - PREVIOUS INSPECTION NOTES AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON, SIDEWALK AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS Inspector Notes from Inspection 9470 09-03-25 TPOLACEK** BUILDER MUST MAINTAIN SITE THROUGHOUT THE ENTIRE BUILD. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/2/2025 - PREVIOUS INSPECTION NOTES 9/2/25 YOU ARE REQUIRED TO HAVE SILT FENCE ACROSS THE FRONT OF SITE ON EITHER SIDE OF THE CONSTRUCTION ENTRANCE. YOU WILL BE GIVEN UNTIL 9/3/25 TO ADD SILT FENCE AS REQUIRED PER COPC RESIDENTIAL DRIVEWAY CONSTRUCTION ENTRANCE STANDARDS. __________________________________________________________________________________________________________________________ 8/29/2025 - PREVIOUS INSPECTION NOTES 08/29/25 TPOLACEK*** SITE CONDITIONS REMAIN UNCHANGED. BUILDER WILL NEED TO MAKE CORRECTION BY TUESDAY OF THERE WILL BE A STOP WORK ORDER PLACED ON SITE. =+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 8/28/2025 - PREVIOUS INSPECTION NOTES SPOKE WITH AUSTIN AND WILL GIVE AN ADDITIONAL DAY TO MAKE CORRECTIONS 8/27/2025 - PREVIOUS INSPECTION NOTES 08/27/25 TPOLACEK**** PERMIT IS PLACED ON HOLD UNTIL ILLICIT DISCHARGE OF CONCRETE IS REMOVED. =+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 8/26/2025 - PREVIOUS INSPECTION NOTES 08/26/25 TPOLACEK *** BUILDER MUST REMOVE OVER POUR CONCRETE FROM SITE, THIS IS AN ILLICIT DISCHARGE AND MAY CONTAMINATE THE STORMWATER SYSTEM YOU WILL HAVE 24 TO REMOVE CONCRETE. BUILDER WILL HAVE 7 DAYS TO REESTABLISH TEMPORARY PIPE AND INSTALL RESIDENTIAL CONSTRUCTION ENTRANCE. *** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day.
ROW- PAVER RESTRAINTS 10/17/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON, SIDEWALK AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS
ROW- PRE-APRON (PRE-POUR) 10/17/2025 PARTIALLY APPROVED TPOLACEK
Note: AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON, SIDEWALK AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS Inspector Notes from Inspection 9470 09-03-25 TPOLACEK** BUILDER MUST MAINTAIN SITE THROUGHOUT THE ENTIRE BUILD. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/2/2025 - PREVIOUS INSPECTION NOTES 9/2/25 YOU ARE REQUIRED TO HAVE SILT FENCE ACROSS THE FRONT OF SITE ON EITHER SIDE OF THE CONSTRUCTION ENTRANCE. YOU WILL BE GIVEN UNTIL 9/3/25 TO ADD SILT FENCE AS REQUIRED PER COPC RESIDENTIAL DRIVEWAY CONSTRUCTION ENTRANCE STANDARDS. __________________________________________________________________________________________________________________________ 8/29/2025 - PREVIOUS INSPECTION NOTES 08/29/25 TPOLACEK*** SITE CONDITIONS REMAIN UNCHANGED. BUILDER WILL NEED TO MAKE CORRECTION BY TUESDAY OF THERE WILL BE A STOP WORK ORDER PLACED ON SITE. =+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 8/28/2025 - PREVIOUS INSPECTION NOTES SPOKE WITH AUSTIN AND WILL GIVE AN ADDITIONAL DAY TO MAKE CORRECTIONS 8/27/2025 - PREVIOUS INSPECTION NOTES 08/27/25 TPOLACEK**** PERMIT IS PLACED ON HOLD UNTIL ILLICIT DISCHARGE OF CONCRETE IS REMOVED. =+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 8/26/2025 - PREVIOUS INSPECTION NOTES 08/26/25 TPOLACEK *** BUILDER MUST REMOVE OVER POUR CONCRETE FROM SITE, THIS IS AN ILLICIT DISCHARGE AND MAY CONTAMINATE THE STORMWATER SYSTEM YOU WILL HAVE 24 TO REMOVE CONCRETE. BUILDER WILL HAVE 7 DAYS TO REESTABLISH TEMPORARY PIPE AND INSTALL RESIDENTIAL CONSTRUCTION ENTRANCE. *** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day.
INSULATION 09/15/2025 APPROVED CVANSTRAHLEN
GRAVITY SEWER TEST 09/15/2025 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2060 THIS WASA VIRTUAL INSPECTION FBC-3303.5 SWALE BLOCKED BY PORTABLE
SEWER TIE IN 09/15/2025 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2060 THIS WAS A VIRTUAL INSPECTION FBC-3303.5 SWALE BLOCKED BY PORTABLE
LATH/BRICK/ WATER BARRIER 09/09/2025 APPROVED CVANSTRAHLEN
ALL ROUGH 09/09/2025 APPROVED CVANSTRAHLEN
ALL ROUGH 09/04/2025 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Please fix items before next inspection #1-FBC [A]107.4-DUCT LAYOUT DOES NOT MATCH ENERGY CALCS ( side B) #2-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE ( side A & B ) #3- Bathrooms Exhausted fans for unit A & B need @ points of security by unit and flex #4-FBCR 609.1-GAP AT WINDOW/DOOR REVEAL TOO LARGE > 1/4 " PER MANUFACTURERS SPECS ( back door on SIde A / Back and front door on Side B)
ROW - DRAINAGE 09/03/2025 APPROVED - AS NOTED TPOLACEK
Note: 09-03-25 TPOLACEK** BUILDER MUST MAINTAIN SITE THROUGHOUT THE ENTIRE BUILD. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/2/2025 - PREVIOUS INSPECTION NOTES 9/2/25 YOU ARE REQUIRED TO HAVE SILT FENCE ACROSS THE FRONT OF SITE ON EITHER SIDE OF THE CONSTRUCTION ENTRANCE. YOU WILL BE GIVEN UNTIL 9/3/25 TO ADD SILT FENCE AS REQUIRED PER COPC RESIDENTIAL DRIVEWAY CONSTRUCTION ENTRANCE STANDARDS. __________________________________________________________________________________________________________________________ 8/29/2025 - PREVIOUS INSPECTION NOTES 08/29/25 TPOLACEK*** SITE CONDITIONS REMAIN UNCHANGED. BUILDER WILL NEED TO MAKE CORRECTION BY TUESDAY OF THERE WILL BE A STOP WORK ORDER PLACED ON SITE. =+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 8/28/2025 - PREVIOUS INSPECTION NOTES SPOKE WITH AUSTIN AND WILL GIVE AN ADDITIONAL DAY TO MAKE CORRECTIONS 8/27/2025 - PREVIOUS INSPECTION NOTES 08/27/25 TPOLACEK**** PERMIT IS PLACED ON HOLD UNTIL ILLICIT DISCHARGE OF CONCRETE IS REMOVED. =+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 8/26/2025 - PREVIOUS INSPECTION NOTES 08/26/25 TPOLACEK *** BUILDER MUST REMOVE OVER POUR CONCRETE FROM SITE, THIS IS AN ILLICIT DISCHARGE AND MAY CONTAMINATE THE STORMWATER SYSTEM YOU WILL HAVE 24 TO REMOVE CONCRETE. BUILDER WILL HAVE 7 DAYS TO REESTABLISH TEMPORARY PIPE AND INSTALL RESIDENTIAL CONSTRUCTION ENTRANCE. *** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day.
ROW - DRAINAGE 09/02/2025 Disapproved -FEE REQUIRED FSLADISH
Note: 9/2/25 YOU ARE REQUIRED TO HAVE SILT FENCE ACROSS THE FRONT OF SITE ON EITHER SIDE OF THE CONSTRUCTION ENTRANCE. YOU WILL BE GIVEN UNTIL 9/3/25 TO ADD SILT FENCE AS REQUIRED PER COPC RESIDENTIAL DRIVEWAY CONSTRUCTION ENTRANCE STANDARDS. NEXT COMPLIANCE REINSPECTION 9/3/25. __________________________________________________________________________________________________________________________ 8/29/2025 - PREVIOUS INSPECTION NOTES 08/29/25 TPOLACEK*** SITE CONDITIONS REMAIN UNCHANGED. BUILDER WILL NEED TO MAKE CORRECTION BY TUESDAY OF THERE WILL BE A STOP WORK ORDER PLACED ON SITE. =+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 8/28/2025 - PREVIOUS INSPECTION NOTES SPOKE WITH AUSTIN AND WILL GIVE AN ADDITIONAL DAY TO MAKE CORRECTIONS 8/27/2025 - PREVIOUS INSPECTION NOTES 08/27/25 TPOLACEK**** PERMIT IS PLACED ON HOLD UNTIL ILLICIT DISCHARGE OF CONCRETE IS REMOVED. =+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 8/26/2025 - PREVIOUS INSPECTION NOTES 08/26/25 TPOLACEK *** BUILDER MUST REMOVE OVER POUR CONCRETE FROM SITE, THIS IS AN ILLICIT DISCHARGE AND MAY CONTAMINATE THE STORMWATER SYSTEM YOU WILL HAVE 24 TO REMOVE CONCRETE. BUILDER WILL HAVE 7 DAYS TO REESTABLISH TEMPORARY PIPE AND INSTALL RESIDENTIAL CONSTRUCTION ENTRANCE. *** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day.
ROW - DRAINAGE 08/29/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 08/29/25 TPOLACEK*** SITE CONDITIONS REMAIN UNCHANGED. BUILDER WILL NEED TO MAKE CORRECTION BY TUESDAY OF THERE WILL BE A STOP WORK ORDER PLACED ON SITE. =+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 8/28/2025 - PREVIOUS INSPECTION NOTES SPOKE WITH AUSTIN AND WILL GIVE AN ADDITIONAL DAY TO MAKE CORRECTIONS 8/27/2025 - PREVIOUS INSPECTION NOTES 08/27/25 TPOLACEK**** PERMIT IS PLACED ON HOLD UNTIL ILLICIT DISCHARGE OF CONCRETE IS REMOVED. =+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 8/26/2025 - PREVIOUS INSPECTION NOTES 08/26/25 TPOLACEK *** BUILDER MUST REMOVE OVER POUR CONCRETE FROM SITE, THIS IS AN ILLICIT DISCHARGE AND MAY CONTAMINATE THE STORMWATER SYSTEM YOU WILL HAVE 24 TO REMOVE CONCRETE. BUILDER WILL HAVE 7 DAYS TO REESTABLISH TEMPORARY PIPE AND INSTALL RESIDENTIAL CONSTRUCTION ENTRANCE. *** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day.
ROW - DRAINAGE 08/28/2025 Disapproved - NO FEE TPOLACEK
Note: SPOKE WITH AUSTIN AND WILL GIVE AN ADDITIONAL DAY TO MAKE CORRECTIONS 8/27/2025 - PREVIOUS INSPECTION NOTES 08/27/25 TPOLACEK**** PERMIT IS PLACED ON HOLD UNTIL ILLICIT DISCHARGE OF CONCRETE IS REMOVED. =+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 8/26/2025 - PREVIOUS INSPECTION NOTES 08/26/25 TPOLACEK *** BUILDER MUST REMOVE OVER POUR CONCRETE FROM SITE, THIS IS AN ILLICIT DISCHARGE AND MAY CONTAMINATE THE STORMWATER SYSTEM YOU WILL HAVE 24 TO REMOVE CONCRETE. BUILDER WILL HAVE 7 DAYS TO REESTABLISH TEMPORARY PIPE AND INSTALL RESIDENTIAL CONSTRUCTION ENTRANCE. *** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day.
ROW - DRAINAGE 08/27/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 08/27/25 TPOLACEK**** PERMIT IS PLACED ON HOLD UNTIL ILLICIT DISCHARGE OF CONCRETE IS REMOVED. =+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 8/26/2025 - PREVIOUS INSPECTION NOTES 08/26/25 TPOLACEK *** BUILDER MUST REMOVE OVER POUR CONCRETE FROM SITE, THIS IS AN ILLICIT DISCHARGE AND MAY CONTAMINATE THE STORMWATER SYSTEM YOU WILL HAVE 24 TO REMOVE CONCRETE. BUILDER WILL HAVE 7 DAYS TO REESTABLISH TEMPORARY PIPE AND INSTALL RESIDENTIAL CONSTRUCTION ENTRANCE. *** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day.
ROW - DRAINAGE 08/26/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 08/26/25 TPOLACEK *** BUILDER MUST REMOVE OVER POUR CONCRETE FROM SITE, THIS IS AN ILLICIT DISCHARGE AND MAY CONTAMINATE THE STORMWATER SYSTEM YOU WILL HAVE 24 TO REMOVE CONCRETE. BUILDER WILL HAVE 7 DAYS TO REESTABLISH TEMPORARY PIPE AND INSTALL RESIDENTIAL CONSTRUCTION ENTRANCE. *** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day.
FIREWALL FINAL 08/19/2025 APPROVED CVANSTRAHLEN
ROOF VALLEY & METAL 08/15/2025 APPROVED CVANSTRAHLEN
Note:
ROOF VALLEY & METAL 08/13/2025 Disapproved -FEE REQUIRED MKRASKI
Note: 1. Remove silt fence from swale to allow water to flow freely. FBC 3303.5 2. Per manufacture specs and roofing worksheet, entire deck must be cover with 2 layer of synthetic underlayment, first run of underlayment at drip edge is only one layer.
FIREWALL DRYWALL NAILING 08/12/2025 APPROVED CVANSTRAHLEN
WALL SHEATHING 08/06/2025 APPROVED CVANSTRAHLEN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/06/2025 APPROVED CVANSTRAHLEN
FIREWALL FRAMING 08/06/2025 APPROVED CVANSTRAHLEN
TIE BEAM / LINTEL 07/22/2025 APPROVED CVANSTRAHLEN
MONOLITHIC SLAB 07/03/2025 APPROVED CVANSTRAHLEN
PLUMBING 1ST ROUGH UNDERGROUND 07/01/2025 APPROVED - AS NOTED MGIBSON
Note: FBC-3303.5 SWALE BLOCKED BY PORTABLE
FORMBOARD SURVEY (OFFICE USE ONLY) 07/01/2025 APPROVED RRICKS
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 06/30/2025 APPROVED JMUNSON
WATER METER INSTALLATION REQUEST 06/13/2025 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 01/06/2026 01/07/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 09/29/2025 09/29/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/16/2025 09/17/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
SW1 COMPLETE 09/16/2025 09/17/2025
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 09/16/2025 09/17/2025
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please turn in original agreement
MECH COMPLETE 09/08/2025 09/08/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 09/04/2025 09/05/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Duct layout is missing returns in bedrooms
SW1 COMPLETE 07/14/2025 07/15/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 07/14/2025 07/14/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/01/2025 07/01/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 07/01/2025 07/01/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BADMIN INFORMATION 06/27/2025 06/27/2025
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Please repload under the correct document type - geo tech certification and rename your file the same.
BLD COMPLETE 06/27/2025 06/30/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SW1 COMPLETE 05/30/2025 06/02/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 05/30/2025 06/02/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ZON COMPLETE 05/30/2025 05/30/2025
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
SW1 HOLD 05/27/2025 05/29/2025
Note: Held By: RODNEY RICKS - (386)986-2001 - RRICKS@PALMCOASTGOV.COM Missing proposed flow elevations on the left side of the property near the front
ENGIN1 COMPLETE 05/27/2025 05/28/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ZON COMPLETE 05/27/2025 05/27/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ZON COMPLETE 05/12/2025 05/12/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SW1 HOLD 05/12/2025 05/15/2025
Note: Held By: RODNEY RICKS - (386)986-2001 - RRICKS@PALMCOASTGOV.COM 1- Berm shall be at the 5' easement to minimize impact to reserved parcel. 2- Base on the elevations on the right and left property lines the berm is not needed on either side.
BLD COMPLETE 05/12/2025 05/19/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
ENGIN1 COMPLETE 05/12/2025 05/13/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
SWALE COMPLETE 05/02/2025 05/22/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
BADMIN COMPLETE 05/01/2025 05/08/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD HOLD 05/01/2025 05/08/2025
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. Plan sheet 2 has "Upper tennant firewall detail" - calls for draftstop in attic and 5/8 type X on ceilings. Plan sheet 3 has Exception 2 in a box stating the same.. Also on PS 3 you have firewall detail utilizing detail U338. Which one are you using? If going with 5/8 type X on ceilings, remove U338 refrence off plans. If using U338 detail, please include the detail drawing as you did for the U905 detail.
CUSVC COMPLETE 05/01/2025 05/08/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 05/01/2025 05/05/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 05/01/2025 05/02/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 05/01/2025 05/02/2025
LOCATE COMPLETE 05/01/2025 05/06/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 05/01/2025 05/02/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 05/01/2025 05/07/2025
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM 1) BENCHMARK NEEDS TO BE IN A POWER POLE OR A FIRE HYDRANT OR MANHOLE PER CITY CODE 300.01 B(9) 2) THE BERM IS NOT NEEDED ON THE SIDE OF THE LOT DUE TO THE PROPERTY LINE ELEVATIONS 3) THE BERM IN THE BACK CAN NOT BE MORE THEN 5' OFF THE BACK PROPERTY LINE DUE TO THE 2:1 SLOPE FOR THE RESERVE PARCEL.
ZON HOLD 05/01/2025 05/02/2025
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Driveways must be a minimum 16ft on each side so driveway should total 32ft in width

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 01/09/2026
REINSPECTION RESIDENTIAL ¤40.00 01/06/2026
REINSPECTION RESIDENTIAL ¤40.00 01/06/2026
REINSPECTION RESIDENTIAL ¤40.00 01/06/2026
RECORDING FEE REIMBURSE DOC ¤52.50 01/06/2026
REINSPECTION RESIDENTIAL ¤40.00 09/02/2025
SW ENG - INSPECTION 20 ¤20.00 09/02/2025
SW ENG - INSPECTION 20 ¤20.00 09/02/2025
SW ENG - INSPECTION 20 ¤20.00 09/02/2025
SW ENG - INSPECTION 20 ¤20.00 09/02/2025
SW ENG - INSPECTION 20 ¤20.00 09/02/2025
SW ENG - INSPECTION 20 ¤20.00 09/02/2025
SW ENG INSPECTION 80 ¤80.00 06/05/2025
SW ENG PRE APRON ¤30.00 06/05/2025
SW ENG - REVIEW 20 ¤20.00 06/05/2025
SW ENG RES REVIEW 200 ¤200.00 06/05/2025
WATER METER W/ TAP ¤4,653.86 06/05/2025
SEWER CREDIT (¤2,294.00) 06/05/2025
WASTEWATER PERM INSPECTION ¤80.00 06/05/2025
WASTEWATER PERM REVIEW ¤100.00 06/05/2025
SEWER CAPITAL FACILITY ¤8,830.00 06/05/2025
WATER CAPITAL FACILITY FEE ¤7,580.98 06/05/2025
WATER PERMIT INSPECTION ¤80.00 06/05/2025
WATER MAIN EXTENSION IMPACT ¤1,834.54 06/05/2025
SITE PLAN 30 ¤30.00 06/05/2025
WATER- TURN ON ¤100.00 06/05/2025
ADJUSTMENT 10% (¤166.09) 06/05/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 06/05/2025
INSPECTION - RESIDENTIAL ¤1,270.50 06/05/2025
PLAN REVIEW - RESIDENTIAL ¤360.36 06/05/2025
IMPACT FEE TRANSPORTATION ¤2,974.00 06/05/2025
WASTEWATER MAIN EXTENSION IMPA ¤4,770.00 06/05/2025
SURCHARGE FS 533.721 ¤14.95 06/05/2025
SURCHARGE - FS 468.631 ¤22.42 06/05/2025
SW ENG - FOUNDATION SURVEY ¤20.00 06/05/2025
FC IMPACT FEE EMS ¤124.00 06/05/2025
IMPACT FEE FIRE ¤869.02 06/05/2025
FC IMPACT FEE LAW ENFORCEMENT ¤436.00 06/05/2025
FC IMPACT FEE LIBRARY ¤536.00 06/05/2025
IMPACT FEE PARKS ¤3,656.02 06/05/2025
IMPACT FEE SCHOOL ¤10,900.00 06/05/2025
Fees Total Due: ¤0.00 Total Paid: ¤47,507.56