Permit #2025050333

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7063-00240-0180
Total Square Footage: 1886 sqft
Block: 00240
Subdivision: 7063 -
Job Phone: 407-912-8154
Location Address: 17 ZINZENDORF PL
Type: BIA - BUILDING INTERIOR EXTERIOR ALTERATION
Issue Date: 05/28/2025
NOC: RECORDED
Applicant name: JUAN CARLOS HENAO-ARISTIZABAL
Owner: ELMORE LESLIE

Address

17 ZINZENDORF PLACE

PALM COAST, FL 32164

Lot: 0180
Contracted Stated Job Value: ¤180,000.00
Job Description: Renovation from fire damage
Type: CN

Contractor

QUEST ROOFING & CONSTRUCTION, LLC
Status Location Address State License Number Phone
ACTIVE

69 CARRIAGE CREEK WAY

ORMOND BEACH, FL 32174

CGC1525988 (Exp: 08/31/2026) 407-912-8154

Sub Contractors

FERNANDO MEZA SR
Status Location Address State License Number Phone
ACTIVE

457 CHELSEA PLACE AVE

ORMOND BEACH, FL 32174

EC13003906 (Exp: 08/31/2026) 386-241-5211
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)
MICHAEL FRANK MORELLO
Status Location Address State License Number Phone Fax
ACTIVE

2 HARGROVE GRADE

PALM COAST, FL 32164

CAC1819466 (Exp: 08/31/2026) 386-445-5023 386-446-4614
JUAN CARLOS HENAO-ARISTIZABAL
Status Location Address State License Number Phone
ACTIVE

69 CARRIAGE CREEK WAY

ORMOND BEACH, FL 32174

CCC1331523 (Exp: 08/31/2026) 407-912-8154

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 10/09/2025 FINAL APPROVED CVANSTRAHLEN
Note: 10/2/2025 - PREVIOUS INSPECTION NOTES 10/2/25: 1). Portable toilet needs to be removed from site for final inspection. FBC [A] 110.3(6) 2). No Energy Calcs on site for inspection. FBC [A]107.3.1 3). Installed equipment does not match model numbers listed on the submitted Energy Calcs. A revision is required updating equipment model numbers. Must be approved prior to scheduling re-inspection. FBC [A]107.4 4). Missing Final Termite Certificate. FBC-R105.11 5). Missing final insulation certificate posted in attic. (or on site). FBC EC R303.1.1.2 6). Range will not fully engage into anti-tip bracket due to plug/cord. Cord is extremely pinched and will require correction to protect from physical damage. FBCR M1901.2 / NEC-400.12(7). 7). Master bathroom toilet is not flushing properly and guest bathroom toilet is gurgling when sink is dumped. Check main drain, vent lines and/or Pep Tank. FBC-P2705.1(4) 8). Missing exterior light outside of master bathroom exterior door. 210.70(A)(2)(2). *** NOTES ADDED BY RSIMS 9/18/2025 10:28:55 AM *** 9/18/25: Must be complete prior to Building Final Inspection. 1). The kitchen island outlets need to be moved to the left and right ends since the counter overhang exceeds 6" past the support base. [NEC-210.52(C)(3)(3)]. FPL emailed to release power.
BLD - BUILDING FINAL 10/02/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 10/2/2025 10:40:45 AM *** 10/2/25: 1). Portable toilet needs to be removed from site for final inspection. FBC [A] 110.3(6) 2). No Energy Calcs on site for inspection. FBC [A]107.3.1 3). Installed equipment does not match model numbers listed on the submitted Energy Calcs. A revision is required updating equipment model numbers. Must be approved prior to scheduling re-inspection. FBC [A]107.4 4). Missing Final Termite Certificate. FBC-R105.11 5). Missing final insulation certificate posted in attic. (or on site). FBC EC R303.1.1.2 6). Range will not fully engage into anti-tip bracket due to plug/cord. Cord is extremely pinched and will require correction to protect from physical damage. FBCR M1901.2 / NEC-400.12(7). 7). Master bathroom toilet is not flushing properly and guest bathroom toilet is gurgling when sink is dumped. Check main drain, vent lines and/or Pep Tank. FBC-P2705.1(4) 8). Missing exterior light outside of master bathroom exterior door. 210.70(A)(2)(2). *** NOTES ADDED BY RSIMS 9/18/2025 10:28:55 AM *** 9/18/25: Must be complete prior to Building Final Inspection. 1). The kitchen island outlets need to be moved to the left and right ends since the counter overhang exceeds 6" past the support base. [NEC-210.52(C)(3)(3)]. FPL emailed to release power.
ELECTRIC - EARLY POWER 09/18/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 9/18/2025 10:28:55 AM *** 9/18/25: Must be complete prior to Building Final Inspection. 1). The kitchen island outlets need to be moved to the left and right ends since the counter overhang exceeds 6" past the support base. [NEC-210.52(C)(3)(3)]. FPL emailed to release power.
INSULATION 07/29/2025 APPROVED MCONTRYMAN
Note: 7/28/2025 - PREVIOUS INSPECTION NOTES 7/28/25 1. Seal up around ceiling in closet by Utility room FBCR 302.11 2. Seal up all wall penetrations in garage FBC EC TABLE R402.4.1.1 3. Missing fire foam above electrical panel in garage FBCR 302.11
INSULATION 07/28/2025 Disapproved - NO FEE MCONTRYMAN
Note: 7/28/25 1. Seal up around ceiling in closet by Utility room FBCR 302.11 2. Seal up all wall penetrations in garage FBC EC TABLE R402.4.1.1 3. Missing fire foam above electrical panel in garage FBCR 302.11
ROOF VALLEY & METAL 07/23/2025 CANCELLED BY INSPECTOR CVANSTRAHLEN
Note: do not need inspection , contractor have a roofing permit for this address
LATH/BRICK/ WATER BARRIER 07/23/2025 APPROVED CVANSTRAHLEN
Note: Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 6/30/2025 2:16:36 PM *** 6/30/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Back side top piece of roof sheathing adjacent to bathroom plumbing wall still needs to be replaced per plan requirements. FBC [A]107.4 (all roof sheathing attached to affected trusses). 2). Valley strapping on both sides of house is missing. Needs to be complete for continuous load path. FBC [A]107.4 3). Need portable toilet on site. FBC P311.1
ALL ROUGH 07/23/2025 APPROVED CVANSTRAHLEN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/01/2025 CANCELLED BY APPLICANT WEB
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/30/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 6/30/2025 2:16:36 PM *** 6/30/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Back side top piece of roof sheathing adjacent to bathroom plumbing wall still needs to be replaced per plan requirements. FBC [A]107.4 (all roof sheathing attached to affected trusses). 2). Valley strapping on both sides of house is missing. Needs to be complete for continuous load path. FBC [A]107.4 3). Need portable toilet on site. FBC P311.1
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/27/2025 CANCELLED BY APPLICANT WEB

Review History

Department Status Date In Date Out
MECH COMPLETE 10/02/2025 10/06/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC COMPLETE 05/20/2025 05/23/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 05/12/2025 05/12/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
PLUM COMPLETE 05/12/2025 05/14/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 05/12/2025 05/19/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
ELEC HOLD 05/12/2025 05/19/2025
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit a riser diagram that includes all wire sizes and breaker sizes. Also must include the surge protectors and outside disconnects. NEC 2020 230.67, 230.85
BLD HOLD 05/08/2025 05/12/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM upload missing plan pages and a scope of work
ELEC HOLD 05/08/2025 05/12/2025
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit electrical plan and scope of work.
MECH COMPLETE 05/08/2025 05/12/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
PLUM HOLD 05/08/2025 05/12/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide scope of work
ZON HOLD 05/08/2025 05/09/2025
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please be specific on what repairs are being done. Any exterior work needs to match existing and plans must state that. Only plan submitted was an elevation page. If changing colors please submit a color sheet. If changing layout of home please submit a site plan showing where the changes are being made with dimensions and setbacks.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 10/08/2025
REINSPECTION RESIDENTIAL ¤40.00 10/08/2025
SURCHARGE FS 533.721 ¤5.99 05/28/2025
SURCHARGE - FS 468.631 ¤8.98 05/28/2025
SITE PLAN 30 ¤30.00 05/28/2025
ADJUSTMENT 10% (¤66.54) 05/28/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 05/28/2025
INSPECTION - RESIDENTIAL ¤495.00 05/28/2025
PLAN REVIEW - RESIDENTIAL ¤140.40 05/28/2025
Fees Total Due: ¤0.00 Total Paid: ¤716.33