Permit #2025050333
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7063-00240-0180 |
| Total Square Footage: 1886 sqft |
| Block: 00240 |
| Subdivision: 7063 - |
| Job Phone: 407-912-8154 |
| Location Address: 17 ZINZENDORF PL |
| Type: BIA - BUILDING INTERIOR EXTERIOR ALTERATION |
| Issue Date: 05/28/2025 |
| NOC: RECORDED |
| Applicant name: JUAN CARLOS HENAO-ARISTIZABAL |
| Owner: ELMORE LESLIE |
|
Address 17 ZINZENDORF PLACE PALM COAST, FL 32164 |
| Lot: 0180 |
| Contracted Stated Job Value: ¤180,000.00 |
| Job Description: Renovation from fire damage |
| Type: CN |
Contractor
QUEST ROOFING & CONSTRUCTION, LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
69 CARRIAGE CREEK WAY ORMOND BEACH, FL 32174 |
CGC1525988 (Exp: 08/31/2026) | 407-912-8154 |
Sub Contractors
FERNANDO MEZA SR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
457 CHELSEA PLACE AVE ORMOND BEACH, FL 32174 |
EC13003906 (Exp: 08/31/2026) | 386-241-5211 |
JUAN CARLOS GONZALEZ
| Status | Location Address | State License Number |
| ACTIVE |
1328 COUNTY ROAD 308 CRESCENT CITY, FL 32112 |
RF11067806 (Exp: 08/31/2027) |
MICHAEL FRANK MORELLO
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2 HARGROVE GRADE PALM COAST, FL 32164 |
CAC1819466 (Exp: 08/31/2026) | 386-445-5023 | 386-446-4614 |
JUAN CARLOS HENAO-ARISTIZABAL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
69 CARRIAGE CREEK WAY ORMOND BEACH, FL 32174 |
CCC1331523 (Exp: 08/31/2026) | 407-912-8154 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 10/09/2025 | FINAL APPROVED | CVANSTRAHLEN |
| Note: 10/2/2025 - PREVIOUS INSPECTION NOTES 10/2/25: 1). Portable toilet needs to be removed from site for final inspection. FBC [A] 110.3(6) 2). No Energy Calcs on site for inspection. FBC [A]107.3.1 3). Installed equipment does not match model numbers listed on the submitted Energy Calcs. A revision is required updating equipment model numbers. Must be approved prior to scheduling re-inspection. FBC [A]107.4 4). Missing Final Termite Certificate. FBC-R105.11 5). Missing final insulation certificate posted in attic. (or on site). FBC EC R303.1.1.2 6). Range will not fully engage into anti-tip bracket due to plug/cord. Cord is extremely pinched and will require correction to protect from physical damage. FBCR M1901.2 / NEC-400.12(7). 7). Master bathroom toilet is not flushing properly and guest bathroom toilet is gurgling when sink is dumped. Check main drain, vent lines and/or Pep Tank. FBC-P2705.1(4) 8). Missing exterior light outside of master bathroom exterior door. 210.70(A)(2)(2). *** NOTES ADDED BY RSIMS 9/18/2025 10:28:55 AM *** 9/18/25: Must be complete prior to Building Final Inspection. 1). The kitchen island outlets need to be moved to the left and right ends since the counter overhang exceeds 6" past the support base. [NEC-210.52(C)(3)(3)]. FPL emailed to release power. | |||
| BLD - BUILDING FINAL | 10/02/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 10/2/2025 10:40:45 AM *** 10/2/25: 1). Portable toilet needs to be removed from site for final inspection. FBC [A] 110.3(6) 2). No Energy Calcs on site for inspection. FBC [A]107.3.1 3). Installed equipment does not match model numbers listed on the submitted Energy Calcs. A revision is required updating equipment model numbers. Must be approved prior to scheduling re-inspection. FBC [A]107.4 4). Missing Final Termite Certificate. FBC-R105.11 5). Missing final insulation certificate posted in attic. (or on site). FBC EC R303.1.1.2 6). Range will not fully engage into anti-tip bracket due to plug/cord. Cord is extremely pinched and will require correction to protect from physical damage. FBCR M1901.2 / NEC-400.12(7). 7). Master bathroom toilet is not flushing properly and guest bathroom toilet is gurgling when sink is dumped. Check main drain, vent lines and/or Pep Tank. FBC-P2705.1(4) 8). Missing exterior light outside of master bathroom exterior door. 210.70(A)(2)(2). *** NOTES ADDED BY RSIMS 9/18/2025 10:28:55 AM *** 9/18/25: Must be complete prior to Building Final Inspection. 1). The kitchen island outlets need to be moved to the left and right ends since the counter overhang exceeds 6" past the support base. [NEC-210.52(C)(3)(3)]. FPL emailed to release power. | |||
| ELECTRIC - EARLY POWER | 09/18/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 9/18/2025 10:28:55 AM *** 9/18/25: Must be complete prior to Building Final Inspection. 1). The kitchen island outlets need to be moved to the left and right ends since the counter overhang exceeds 6" past the support base. [NEC-210.52(C)(3)(3)]. FPL emailed to release power. | |||
| INSULATION | 07/29/2025 | APPROVED | MCONTRYMAN |
| Note: 7/28/2025 - PREVIOUS INSPECTION NOTES 7/28/25 1. Seal up around ceiling in closet by Utility room FBCR 302.11 2. Seal up all wall penetrations in garage FBC EC TABLE R402.4.1.1 3. Missing fire foam above electrical panel in garage FBCR 302.11 | |||
| INSULATION | 07/28/2025 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 7/28/25 1. Seal up around ceiling in closet by Utility room FBCR 302.11 2. Seal up all wall penetrations in garage FBC EC TABLE R402.4.1.1 3. Missing fire foam above electrical panel in garage FBCR 302.11 | |||
| ROOF VALLEY & METAL | 07/23/2025 | CANCELLED BY INSPECTOR | CVANSTRAHLEN |
| Note: do not need inspection , contractor have a roofing permit for this address | |||
| LATH/BRICK/ WATER BARRIER | 07/23/2025 | APPROVED | CVANSTRAHLEN |
| Note: Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 6/30/2025 2:16:36 PM *** 6/30/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Back side top piece of roof sheathing adjacent to bathroom plumbing wall still needs to be replaced per plan requirements. FBC [A]107.4 (all roof sheathing attached to affected trusses). 2). Valley strapping on both sides of house is missing. Needs to be complete for continuous load path. FBC [A]107.4 3). Need portable toilet on site. FBC P311.1 | |||
| ALL ROUGH | 07/23/2025 | APPROVED | CVANSTRAHLEN |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/01/2025 | CANCELLED BY APPLICANT | WEB |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/30/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 6/30/2025 2:16:36 PM *** 6/30/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Back side top piece of roof sheathing adjacent to bathroom plumbing wall still needs to be replaced per plan requirements. FBC [A]107.4 (all roof sheathing attached to affected trusses). 2). Valley strapping on both sides of house is missing. Needs to be complete for continuous load path. FBC [A]107.4 3). Need portable toilet on site. FBC P311.1 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/27/2025 | CANCELLED BY APPLICANT | WEB |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 10/02/2025 | 10/06/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 05/20/2025 | 05/23/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/12/2025 | 05/12/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| PLUM | COMPLETE | 05/12/2025 | 05/14/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 05/12/2025 | 05/19/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 05/12/2025 | 05/19/2025 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit a riser diagram that includes all wire sizes and breaker sizes. Also must include the surge protectors and outside disconnects. NEC 2020 230.67, 230.85 | |||
| BLD | HOLD | 05/08/2025 | 05/12/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM upload missing plan pages and a scope of work | |||
| ELEC | HOLD | 05/08/2025 | 05/12/2025 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit electrical plan and scope of work. | |||
| MECH | COMPLETE | 05/08/2025 | 05/12/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| PLUM | HOLD | 05/08/2025 | 05/12/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide scope of work | |||
| ZON | HOLD | 05/08/2025 | 05/09/2025 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please be specific on what repairs are being done. Any exterior work needs to match existing and plans must state that. Only plan submitted was an elevation page. If changing colors please submit a color sheet. If changing layout of home please submit a site plan showing where the changes are being made with dimensions and setbacks. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 10/08/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 10/08/2025 |
| SURCHARGE FS 533.721 | ¤5.99 | 05/28/2025 |
| SURCHARGE - FS 468.631 | ¤8.98 | 05/28/2025 |
| SITE PLAN 30 | ¤30.00 | 05/28/2025 |
| ADJUSTMENT 10% | (¤66.54) | 05/28/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 05/28/2025 |
| INSPECTION - RESIDENTIAL | ¤495.00 | 05/28/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤140.40 | 05/28/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤716.33 |