I want to search for...
Permit #2025050344
Permit Details
Status: COED
| Parcel Id: 03-12-31-1125-00000-0410 |
| CONDITIONED SPACE: 2394 sqft |
| GARAGE: 502 sqft |
| OPENED PORCH (WITH ROOF) : 43 sqft |
| OPENED PORCH (WITH ROOF) : 176 sqft |
| Total Square Footage: 3115 sqft |
| Subdivision: 2112 - COLBERT LANDINGS PH 1 |
| Job Phone: 813-917-1689 |
| Location Address: 31 ARMOYAN DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 05/15/2025 |
| NOC: RECORDED |
| Applicant name: SCOTT EVAN KEUNING |
| Owner: TAYLOR MORRISON OF FLORIDA INC |
|
Address 1275 W GRANADA BLVD ORMOND BEACH, FL 32174 |
|
Address SUITE 3B ORMOND BEACH, FL 32174 |
| Lot: 41 |
| Contracted Stated Job Value: ¤183,103.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
TAYLOR MORRISON OF FLORIDA INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
7785 BAY MEADOWS WAY, SUITE 105 JACKSONVILLE, FL 32256 |
CBC1265083 (Exp: 08/31/2026) | 813-917-1689 |
Sub Contractors
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PKWY SANFORD, FL 32771 |
CAC043953 (Exp: 08/31/2026) | 877-906-1113 |
JOSEPH HORATIO STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PARKWAY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2026) | 877-906-1113 |
BENJAMIN MICHAEL RAY
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
6310 MABLETON PKWY JACKSONVILLE, FL 32216 |
SUITE 1000 MABLETON, GA 30126 |
CFC1428415 (Exp: 08/31/2026) | 904-861-5421 | 904-861-5426 |
CHASE RANDOLPH MASSEY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
10048 103RD ST JACKSONVILLE, FL 32210 |
CCC1332486 (Exp: 08/31/2026) | 904-248-1133 |
Inspection History
| Type | Request Date | Result | Inspector |
| U-CROSS CONNECTION | 10/31/2025 | APPROVED - AS NOTED | BHAINES |
| Note: No CC, IRR using potable water, IRR meter in place | |||
| ROW - FINAL APRON (AFTER POUR) | 10/31/2025 | APPROVED | FSLADISH |
| Note: 10/31/25 . AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW - STORMWATER FINAL | 10/31/2025 | APPROVED | FSLADISH |
| Note: 10/31/25 . AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. NOTING THAT BUILDER IS RESPONSIBLE FOR MISSING CONCRETE IN CURB AND GUTTER BEFORE TURNING OVER TO HOA. | |||
| U -UTILITY RESIDENTIAL FINAL | 10/31/2025 | FINAL APPROVED | BHAINES |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 10/30/2025 | APPROVED | FSLADISH |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 10/30/2025 | APPROVED | FSLADISH |
| Note: 10/30/25 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| BLD - BUILDING FINAL | 10/23/2025 | FINAL APPROVED | BTAYLOR |
| ELECTRIC - EARLY POWER | 09/26/2025 | APPROVED - AS NOTED | BTAYLOR |
| Note: 9-26-25 1. Emailed FPL at 10:13. Inspector Notes from Inspection 2200 7-2-25 1. Emailed FPL at 10:41. | |||
| LATH/BRICK/ WATER BARRIER | 09/04/2025 | APPROVED | BTAYLOR |
| ROW- PRE-APRON (PRE-POUR) | 08/26/2025 | APPROVED | FSLADISH |
| Note: 8/26/25 BUILDER REFER TO CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. . IF FIBERGLASS OPTION IS USED, BUILDER REQUIRED TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED DOCUMENTATION OF THE (FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK SITE FOR ANY STANDING WATER. ALSO VERIFY PIPE ELEVATION HAS NOT CHANGED. AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| GRAVITY SEWER TEST | 08/20/2025 | APPROVED | MCONTRYMAN |
| SEWER TIE IN | 08/20/2025 | APPROVED | MCONTRYMAN |
| INSULATION | 07/24/2025 | APPROVED | MCONTRYMAN |
| ALL ROUGH | 07/17/2025 | APPROVED | BTAYLOR |
| LATH/BRICK/ WATER BARRIER | 07/16/2025 | APPROVED | BTAYLOR |
| ROOF VALLEY & METAL | 07/09/2025 | APPROVED | BTAYLOR |
| Note: Inspector Notes from Inspection 2460 6-27-25 1. Bearing block on truss A01 needs to be vertical not horizontal. | |||
| ELECTRIC-TUG | 07/02/2025 | APPROVED - AS NOTED | BTAYLOR |
| Note: 7-2-25 1. Emailed FPL at 10:41. | |||
| WALL SHEATHING | 06/27/2025 | APPROVED | BTAYLOR |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/27/2025 | APPROVED - AS NOTED | BTAYLOR |
| Note: 6-27-25 1. Bearing block on truss A01 needs to be vertical not horizontal. | |||
| MONOLITHIC SLAB | 06/10/2025 | APPROVED | BTAYLOR |
| Note: 6/6/2025 - PREVIOUS INSPECTION NOTES 6-6-25 1. Due to rain footers need to redug to give the clearance for the rebar. | |||
| MONOLITHIC SLAB | 06/06/2025 | Disapproved - NO FEE | BTAYLOR |
| Note: 6-6-25 1. Due to rain footers need to redug to give the clearance for the rebar. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 06/04/2025 | APPROVED | MGIBSON |
| Note: 5/30/2025 - PREVIOUS INSPECTION NOTES FBCR-P-2503.5 HEAD TEST NOT HOLDING | |||
| FORMBOARD SURVEY (OFFICE USE ONLY) | 06/02/2025 | APPROVED | RRICKS |
| PLUMBING 1ST ROUGH UNDERGROUND | 05/30/2025 | Disapproved -FEE REQUIRED | MGIBSON |
| Note: FBCR-P-2503.5 HEAD TEST NOT HOLDING | |||
| WATER METER INSTALLATION REQUEST | 05/30/2025 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 05/30/2025 | 06/02/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/30/2025 | 05/30/2025 |
| Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM | |||
| URB | COMPLETE | 05/12/2025 | 05/15/2025 |
| Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 05/08/2025 | 05/15/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 05/08/2025 | 05/15/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 05/08/2025 | 05/14/2025 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM Meter already installed, no additional fees owed at this time. | |||
| ELEC | COMPLETE | 05/08/2025 | 05/12/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 05/08/2025 | 05/08/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 05/08/2025 | 05/12/2025 |
| LOCATE | COMPLETE | 05/08/2025 | 05/13/2025 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 05/08/2025 | 05/12/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 05/08/2025 | 05/14/2025 |
| Note: Released By: RODNEY RICKS - (386)986-2001 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/08/2025 | 05/12/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 10/31/2025 |
| FC IMPACT FEE EMS | ¤62.00 | 05/15/2025 |
| IMPACT FEE FIRE | ¤434.51 | 05/15/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 05/15/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 05/15/2025 |
| IMPACT FEE PARKS | ¤1,828.01 | 05/15/2025 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 05/15/2025 |
| IMPACT FEE TRANSPORTATION | ¤3,502.00 | 05/15/2025 |
| SURCHARGE FS 533.721 | ¤14.50 | 05/15/2025 |
| SURCHARGE - FS 468.631 | ¤21.75 | 05/15/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 05/15/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 05/15/2025 |
| SW ENG PRE APRON | ¤30.00 | 05/15/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 05/15/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 05/15/2025 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 05/15/2025 |
| WASTEWATER PERM REVIEW | ¤25.00 | 05/15/2025 |
| WATER PERMIT REVIEW | ¤25.00 | 05/15/2025 |
| SITE PLAN 30 | ¤30.00 | 05/15/2025 |
| ADJUSTMENT 10% | (¤161.14) | 05/15/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 05/15/2025 |
| INSPECTION - RESIDENTIAL | ¤1,232.00 | 05/15/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤349.44 | 05/15/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤13,799.07 |