I want to search for...

Permit #2025050368

Permit Details

Status: INSPECT

Parcel Id: 07-11-31-7025-00520-0200
Block: 00520
Subdivision: 7025 -
Job Phone: 386-264-8099
Location Address: 2 PAULINE PL
Type: AL - ALUMINUM SCREEN STRUCTURE
Issue Date: 01/26/2026
NOC: RECORDED
Applicant name: CHAD W HENDERSON
Owner: REED RODNEY & SUZANNE CONAWAY H&W

Address

2 PAULINE PLACE

PALM COAST, FL 0

Lot: 0200
Contracted Stated Job Value: ¤12,226.50
Job Description: SCREEN ENCLOSURE ON EXISTING DECK
Type: CN

Contractor

QUALITY 1ST ALUMINUM LLC
Status Location Address Phone
ACTIVE

27 FERNON LN

PALM COAST, FL 32137

386-275-8889

Inspection History

Type Request Date Result Inspector
FINAL - BUILDING MISC 02/05/2026 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 2/5/2026 10:50:40 AM *** 2/5/26: 1). Left side of cage: front cable is excessively loose. back cable is excessively loose and cleat is missing an anchor. FBC-[A] 107.4 2). Right side of cage: cable is loose. Check all. FBC-[A] 107.4 3). Enclosure needs to be properly grounded/bonded. A ground wire runs to the clamp on the pool pump but the pool pump is not ground/bonded. NEC -250.4(A)(4) / 250.109 NOTE: There is a ground rod available to use for proper grounding/bonding at the back side of the enclosure. NEC -250.4(A)(4) / 250.109
FINAL - BUILDING MISC
Note: 2/5/2026 - PREVIOUS INSPECTION NOTES 2/5/26: 1). Left side of cage: front cable is excessively loose. back cable is excessively loose and cleat is missing an anchor. FBC-[A] 107.4 2). Right side of cage: cable is loose. Check all. FBC-[A] 107.4 3). Enclosure needs to be properly grounded/bonded. A ground wire runs to the clamp on the pool pump but the pool pump is not ground/bonded. NEC -250.4(A)(4) / 250.109 NOTE: There is a ground rod available to use for proper grounding/bonding at the back side of the enclosure. NEC -250.4(A)(4) / 250.109

Review History

Department Status Date In Date Out
ZON COMPLETE 05/20/2025 05/20/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 05/20/2025 05/22/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BFLOOD COMPLETE 05/08/2025 05/15/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD HOLD 05/08/2025 05/15/2025
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM No evidence of proper footer to support enclosure.
ZON HOLD 05/08/2025 05/08/2025
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM This site plan is not for this property. The City does not have one on file for this propertyl Please get a copy from the homeowner in order to submit the correct site plan (survey). The legal for 2 Pauline Place is 07-11-31-7025-00520-0200 but the survey (site plan) submtted was for 07-11-317025-00560-0200. It's a different block....and the lot is on Panorama Drive, not Pauline Place.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 10% (¤12.25) 01/26/2026
INSPECTION - ALUMINUM ENCLOSU ¤60.00 01/26/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 01/26/2026
PLAN REVIEW - MISC 32.50 ¤32.50 01/26/2026
SURCHARGE FS 533.721 ¤2.00 01/26/2026
SURCHARGE - FS 468.631 ¤2.00 01/26/2026
SITE PLAN 15 ¤15.00 01/26/2026
ADJUSTMENT 10% ¤12.25 01/21/2026
SURCHARGE - FS 468.631 ¤2.00 01/21/2026
SITE PLAN 15 ¤15.00 01/21/2026
SITE PLAN 15 (¤15.00) 01/21/2026
SURCHARGE - FS 468.631 (¤2.00) 01/21/2026
SURCHARGE FS 533.721 ¤2.00 01/21/2026
SURCHARGE FS 533.721 (¤2.00) 01/21/2026
INSPECTION - ALUMINUM ENCLOSU (¤60.00) 01/21/2026
INSPECTION - ALUMINUM ENCLOSU ¤60.00 01/21/2026
PLAN REVIEW - MISC 32.50 ¤32.50 01/21/2026
PLAN REVIEW - MISC 32.50 (¤32.50) 01/21/2026
ADJUSTMENT 10% (¤12.25) 01/21/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 01/21/2026
ADMINISTRATIVE RESIDENTIAL (¤30.00) 01/21/2026
REINSPECTION RESIDENTIAL ¤40.00
Fees Total Due: ¤40.00 Total Paid: ¤129.25