Permit #2025050389

Permit Details

Status: COED

Parcel Id: 07-11-31-7023-00220-0320
CONDITIONED SPACE: 1312 sqft
GARAGE: 433 sqft
OPENED PORCH (WITH ROOF) : 16 sqft
Total Square Footage: 1761 sqft
Block: 00220
Subdivision: 7023 -
Job Phone: 352-433-8382
Location Address: 41 WHITTINGHAM LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 05/27/2025
NOC: RECORDED
Applicant name: ALFREDO E SCHEER
Owner: ESTELA SPECS 6 LLC

Address

2601 SOUTH BAYSHORE DRIVE

MIAMI, FL 33133

Address

18TH FLOOR

MIAMI, FL 33133

Lot: 0320
Contracted Stated Job Value: ¤145,000.00
Job Description: Single Family Residence
Type: CN

Contractor

ESTELA LIVING LLC
Status Location Address State License Number Phone
ACTIVE

237 S. DIXIE HWY, 4TH FLOOR

CORAL GABLES, FL 33133

CGC1534535 (Exp: 08/31/2026) 352-433-8382

Sub Contractors

JOSEPH HORATIO STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PARKWAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2026) 877-906-1113
JOSEPH HORATIO STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PARKWAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2026) 877-906-1113
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)

Inspection History

Type Request Date Result Inspector
ROW - STORMWATER FINAL 02/19/2026 APPROVED FSLADISH
Note: 2/19/26 REQUIRED CORRECTION COMPLETED AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. _____________________________________________________________________________________________________________________________ 2/17/2026 - PREVIOUS INSPECTION NOTES 2/17/26 AREA INDICATED BY PREVIOUS INSPECTOR STILL DOES NOT HAVE POSITUVE LEFT TO RIGHT FLOW IN THE SWALE IT IS HIGH WHERE I HAVE OUTLINED IT IN PAINT. THIS AREA NEEDS TO COME DOWN AND MATCH GRADE ON BOTH SIDES. DRAINAGE WILL CURRENTLY SIT AT LEFT SIDE PROPERTY LINE DUE TO ELEVATION DIFFERENCE. PLEASE MAKE CORRECTION TO POSITIVE FLOWABLE GRADE. SEE PHOTO FOR REFERENCE. 2/3/2026 - PREVIOUS INSPECTION NOTES ** LEFT SIDE ROAD SIDE SWALE DRAINAGE IS INCONSISTANT NEED TO M,ATCH GRADE AT PROPERTY LINE AND HAVE POSITIVE FALL FROM LEFT TO RIGHT ** NOTE PINK PAINT FOR AREA NEEDING TO BE FIXED
ROW - STORMWATER FINAL 02/17/2026 Disapproved -FEE REQUIRED FSLADISH
Note: 2/17/26 AREA INDICATED BY PREVIOUS INSPECTOR STILL DOES NOT HAVE POSITUVE LEFT TO RIGHT FLOW IN THE SWALE IT IS HIGH WHERE I HAVE OUTLINED IT IN PAINT. THIS AREA NEEDS TO COME DOWN AND MATCH GRADE ON BOTH SIDES. DRAINAGE WILL CURRENTLY SIT AT LEFT SIDE PROPERTY LINE DUE TO ELEVATION DIFFERENCE. PLEASE MAKE CORRECTION TO POSITIVE FLOWABLE GRADE. SEE PHOTO FOR REFERENCE. 2/3/2026 - PREVIOUS INSPECTION NOTES ** LEFT SIDE ROAD SIDE SWALE DRAINAGE IS INCONSISTANT NEED TO M,ATCH GRADE AT PROPERTY LINE AND HAVE POSITIVE FALL FROM LEFT TO RIGHT ** NOTE PINK PAINT FOR AREA NEEDING TO BE FIXED
ROW - STORMWATER FINAL 02/03/2026 Disapproved - NO FEE EMADISON
Note: ** LEFT SIDE ROAD SIDE SWALE DRAINAGE IS INCONSISTANT NEED TO M,ATCH GRADE AT PROPERTY LINE AND HAVE POSITIVE FALL FROM LEFT TO RIGHT ** NOTE PINK PAINT FOR AREA NEEDING TO BE FIXED
U -UTILITY RESIDENTIAL FINAL 02/03/2026 FINAL APPROVED BWRIGHT
Note: Inspector Notes from Inspection 9035 NO IRR/ NO CC
ROW - FINAL APRON (AFTER POUR) 02/03/2026 APPROVED EMADISON
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW FIELD SURVEY /GRADING CERTIFICATION 02/02/2026 APPROVED FSLADISH
Note: 2/2/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
BLD - BUILDING FINAL 01/30/2026 FINAL APPROVED MKRASKI
BLD - BUILDING FINAL 01/27/2026 Disapproved - NO FEE MKRASKI
Note: 1/27/26 1. W/P cover for ufer ground by meter main does not seal to wall 2. Spare tub does not drain 3. Master bathroom vanity sink does not drain
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/14/2026 APPROVED FSLADISH
Note: 1/12/2026 - PREVIOUS INSPECTION NOTES 1/12/26 PLEASE READ PREVIOUS NOTES. YOU DO NOT MEET THE FLORIDA BUILDING CODE REQUIRED 6" FALL OF THE REAR OF THE STUCTURE IN THE FIRST 10 FEET. Drainage from the structure is to be a 6-inch (5%) Residential, Chapter 4, R401.3 "Drainage from the structure is to be a 6-inch (5%) minimum slope for the first 10 FT. E.Florida Building Code, Residential, Chapter 4, R401.3" SEE PHOTO FOR REFERENCE. 12/3/2025 - PREVIOUS INSPECTION NOTES 12-3-25 TPOLACEK*** FINAL SURVEY INDICATES THE DRAINAGE OFF THER ESAR OF THE STRUCTURE DOES NOT MEET REQUIRMENTS. THERE MUST BE A MINIMUM OF 6" OF FALL IN THE FIRST 10' FINAL SUREVY SHOWS .07. RIGHT SIDE PROPERTY LINE INDICATES DRAINAGE WILL FLOW ACROSS PROPERTY LINE ONTO ADJOINING PROPERTY. 11/14/2025 - PREVIOUS INSPECTION NOTES 11-14-25 TPOLACEK*** FINAL SURVEY DOES NOT INDICATE CULVERT INV ELEVATION, THERE ARE NOT ENOUGH PROPERTY LINE SHOTS, THERE ARE NOT THE REQUIRED SHOTS AROUND STRUCTURE, THERE ARE NOT THE REQUIRED ELEVATION SHOTS THROUGHOUT THE ENTIRE PROPERTY.
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/12/2026 Disapproved -FEE REQUIRED FSLADISH
Note: 1/12/26 PLEASE READ PREVIOUS NOTES. YOU DO NOT MEET THE FLORIDA BUILDING CODE REQUIRED 6" FALL OF THE REAR OF THE STUCTURE IN THE FIRST 10 FEET. Drainage from the structure is to be a 6-inch (5%) Residential, Chapter 4, R401.3 "Drainage from the structure is to be a 6-inch (5%) minimum slope for the first 10 FT. E.Florida Building Code, Residential, Chapter 4, R401.3" SEE PHOTO FOR REFERENCE. 12/3/2025 - PREVIOUS INSPECTION NOTES 12-3-25 TPOLACEK*** FINAL SURVEY INDICATES THE DRAINAGE OFF THER ESAR OF THE STRUCTURE DOES NOT MEET REQUIRMENTS. THERE MUST BE A MINIMUM OF 6" OF FALL IN THE FIRST 10' FINAL SUREVY SHOWS .07. RIGHT SIDE PROPERTY LINE INDICATES DRAINAGE WILL FLOW ACROSS PROPERTY LINE ONTO ADJOINING PROPERTY. 11/14/2025 - PREVIOUS INSPECTION NOTES 11-14-25 TPOLACEK*** FINAL SURVEY DOES NOT INDICATE CULVERT INV ELEVATION, THERE ARE NOT ENOUGH PROPERTY LINE SHOTS, THERE ARE NOT THE REQUIRED SHOTS AROUND STRUCTURE, THERE ARE NOT THE REQUIRED ELEVATION SHOTS THROUGHOUT THE ENTIRE PROPERTY.
BLD - BUILDING FINAL 12/09/2025 CANCELLED BY APPLICANT MKRASKI
U-CROSS CONNECTION 12/09/2025 APPROVED - AS NOTED BWRIGHT
Note: NO IRR/ NO CC
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/03/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 12-3-25 TPOLACEK*** FINAL SURVEY INDICATES THE DRAINAGE OFF THER ESAR OF THE STRUCTURE DOES NOT MEET REQUIRMENTS. THERE MUST BE A MINIMUM OF 6" OF FALL IN THE FIRST 10' FINAL SUREVY SHOWS .07. RIGHT SIDE PROPERTY LINE INDICATES DRAINAGE WILL FLOW ACROSS PROPERTY LINE ONTO ADJOINING PROPERTY. 11/14/2025 - PREVIOUS INSPECTION NOTES 11-14-25 TPOLACEK*** FINAL SURVEY DOES NOT INDICATE CULVERT INV ELEVATION, THERE ARE NOT ENOUGH PROPERTY LINE SHOTS, THERE ARE NOT THE REQUIRED SHOTS AROUND STRUCTURE, THERE ARE NOT THE REQUIRED ELEVATION SHOTS THROUGHOUT THE ENTIRE PROPERTY.
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/14/2025 Disapproved - NO FEE TPOLACEK
Note: 11-14-25 TPOLACEK*** FINAL SURVEY DOES NOT INDICATE CULVERT INV ELEVATION, THERE ARE NOT ENOUGH PROPERTY LINE SHOTS, THERE ARE NOT THE REQUIRED SHOTS AROUND STRUCTURE, THERE ARE NOT THE REQUIRED ELEVATION SHOTS THROUGHOUT THE ENTIRE PROPERTY.
ROW- PRE-APRON (PRE-POUR) 10/16/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. Inspector Notes from Inspection 9470 10-01-25 TPOLACEK*** GRADER IS ON SITE APPROVING AS NOTED. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/30/2025 - PREVIOUS INSPECTION NOTES 09-30-25 TPOLACEK*** NO CHANGES AND MORE SEDIMENT HAS WASHED INTO SWALE. NEXT INSPECTION 10-01-25 PHOTO ATTACHED ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/29/2025 - PREVIOUS INSPECTION NOTES 09-29-25 TPOLACEK**** NO CHANGES. BUILDER MUST CLEAR SWALE OF ALL WASHED OUT SEDIMENT AND OPEN SWALE. SILT FENCE IS DESIGNED TO KEEP SITE FROM WASHING INTO STORMWATER SYSTEM. THUS WAS DISCUSSED IN PERSON AND NO CHANGES HAVE BEEN MADE. PERMIT IS NOW PLACED ON HOLD UNTIL CONDITIONS ARE CORRECTED. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/24/2025 - PREVIOUS INSPECTION NOTES 09-24-25 TPOLACEK*** SILT FENCE ALONG FRONT IS STILL NOT INSTALLED AS REQUIRED. BUILDER HAS 3 DAYS UNTIL PERMIT IS PLACED ON HOLD. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/17/2025 - PREVIOUS INSPECTION NOTES TPOLACEK*** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day.
ROW - DRAINAGE 10/01/2025 APPROVED - AS NOTED TPOLACEK
Note: 10-01-25 TPOLACEK*** GRADER IS ON SITE APPROVING AS NOTED. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/30/2025 - PREVIOUS INSPECTION NOTES 09-30-25 TPOLACEK*** NO CHANGES AND MORE SEDIMENT HAS WASHED INTO SWALE. NEXT INSPECTION 10-01-25 PHOTO ATTACHED ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/29/2025 - PREVIOUS INSPECTION NOTES 09-29-25 TPOLACEK**** NO CHANGES. BUILDER MUST CLEAR SWALE OF ALL WASHED OUT SEDIMENT AND OPEN SWALE. SILT FENCE IS DESIGNED TO KEEP SITE FROM WASHING INTO STORMWATER SYSTEM. THUS WAS DISCUSSED IN PERSON AND NO CHANGES HAVE BEEN MADE. PERMIT IS NOW PLACED ON HOLD UNTIL CONDITIONS ARE CORRECTED. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/24/2025 - PREVIOUS INSPECTION NOTES 09-24-25 TPOLACEK*** SILT FENCE ALONG FRONT IS STILL NOT INSTALLED AS REQUIRED. BUILDER HAS 3 DAYS UNTIL PERMIT IS PLACED ON HOLD. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/17/2025 - PREVIOUS INSPECTION NOTES TPOLACEK*** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day.
ROW - DRAINAGE 09/30/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 09-30-25 TPOLACEK*** NO CHANGES AND MORE SEDIMENT HAS WASHED INTO SWALE. NEXT INSPECTION 10-01-25 PHOTO ATTACHED ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/29/2025 - PREVIOUS INSPECTION NOTES 09-29-25 TPOLACEK**** NO CHANGES. BUILDER MUST CLEAR SWALE OF ALL WASHED OUT SEDIMENT AND OPEN SWALE. SILT FENCE IS DESIGNED TO KEEP SITE FROM WASHING INTO STORMWATER SYSTEM. THUS WAS DISCUSSED IN PERSON AND NO CHANGES HAVE BEEN MADE. PERMIT IS NOW PLACED ON HOLD UNTIL CONDITIONS ARE CORRECTED. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/24/2025 - PREVIOUS INSPECTION NOTES 09-24-25 TPOLACEK*** SILT FENCE ALONG FRONT IS STILL NOT INSTALLED AS REQUIRED. BUILDER HAS 3 DAYS UNTIL PERMIT IS PLACED ON HOLD. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/17/2025 - PREVIOUS INSPECTION NOTES TPOLACEK*** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day.
ROW - DRAINAGE 09/29/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 09-29-25 TPOLACEK**** NO CHANGES. BUILDER MUST CLEAR SWALE OF ALL WASHED OUT SEDIMENT AND OPEN SWALE. SILT FENCE IS DESIGNED TO KEEP SITE FROM WASHING INTO STORMWATER SYSTEM. THUS WAS DISCUSSED IN PERSON AND NO CHANGES HAVE BEEN MADE. PERMIT IS NOW PLACED ON HOLD UNTIL CONDITIONS ARE CORRECTED. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/24/2025 - PREVIOUS INSPECTION NOTES 09-24-25 TPOLACEK*** SILT FENCE ALONG FRONT IS STILL NOT INSTALLED AS REQUIRED. BUILDER HAS 3 DAYS UNTIL PERMIT IS PLACED ON HOLD. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/17/2025 - PREVIOUS INSPECTION NOTES TPOLACEK*** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day.
ROW - DRAINAGE 09/24/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 09-24-25 TPOLACEK*** SILT FENCE ALONG FRONT IS STILL NOT INSTALLED AS REQUIRED. BUILDER HAS 3 DAYS UNTIL PERMIT IS PLACED ON HOLD. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/17/2025 - PREVIOUS INSPECTION NOTES TPOLACEK*** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day.
GRAVITY SEWER TEST 09/24/2025 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2060 THIS WAS A VIRTUAL INSPECTION REMOVE TREE ROOT BEFORE BACKFILLING ON WATER DISTRIBUTION AND DWV
SEWER TIE IN 09/24/2025 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2075 THISWAS A VIRTUAL INSPECTION Inspector Notes from Inspection 2060 THIS WAS A VIRTUAL INSPECTION REMOVE TREE ROOT BEFORE BACKFILLING ON WATER DISTRIBUTION AND DWV
ELECTRIC - EARLY POWER 09/24/2025 APPROVED - AS NOTED MKRASKI
Note: 1. Ufer ground must be accessible by final Emailed FPL @ 3pm for power release
ROW - DRAINAGE 09/17/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: TPOLACEK*** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day.
PEP TANK INSTALLATION REQUEST 09/02/2025 APPROVED CBOWERMASTER
LATH/BRICK/ WATER BARRIER 08/21/2025 APPROVED MKRASKI
INSULATION 08/20/2025 APPROVED MKRASKI
INSULATION 08/19/2025 Disapproved - NO FEE MKRASKI
Note: 8/19/25 1. From previous inspection, line set chase in AHU closet needs to be sealed at slab penitration FBC EC R402.4.1.1 8/14/25: Added cardboard baffles are required to have 1" minimum clearance from roof sheathing. FBC-R806.3 8/14/25: 1). Previously listed item 3 remains unresolved. > 3. Please properly seal slab penitration for line set chase (not chase but slab around it) FBC EC R402.4.1.1 2). Missing Fireblocking at top plate in garage to the left of breaker panel. Stud marked FB below. FBC-302.11 3). Laundry Room: Firestop at top plate penetration for PVC vent stack is incomplete. Marked FSI below area. FBC-302.11 Inspector Notes from Inspection 2420 8/12/25 1. Please check all anchors for overhead garage door bucks to ensure they are tight 2. E-cals duct layout does not match what was installed 3. Please properly seal slab penitration for line set chase (not chase but slab around it) FBC EC R402.4.1.1 Check items at insulation 8/7/25 1. No E-cals on site FBC 107.3.1 2. PLumbing pipes must be properly supported FBCR P2605.1 3. Romex must be supported with in 12'' of panel NEC 334.30 4. Over head garage door buck detail calls out SD-3 "F" there is not detail, There is a "E" detail and that shows anchors must be within 24'' and must be tightened
INSULATION 08/14/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 8/14/2025 9:33:52 AM *** 8/14/25: Added cardboard baffles are required to have 1" minimum clearance from roof sheathing. FBC-R806.3 *** NOTES ADDED BY RSIMS 8/14/2025 9:23:24 AM *** 8/14/25: 1). Previously listed item 3 remains unresolved. > 3. Please properly seal slab penitration for line set chase (not chase but slab around it) FBC EC R402.4.1.1 2). Missing Fireblocking at top plate in garage to the left of breaker panel. Stud marked FB below. FBC-302.11 3). Laundry Room: Firestop at top plate penetration for PVC vent stack is incomplete. Marked FSI below area. FBC-302.11 Inspector Notes from Inspection 2420 8/12/25 1. Please check all anchors for overhead garage door bucks to ensure they are tight 2. E-cals duct layout does not match what was installed 3. Please properly seal slab penitration for line set chase (not chase but slab around it) FBC EC R402.4.1.1 Check items at insulation 8/7/25 1. No E-cals on site FBC 107.3.1 2. PLumbing pipes must be properly supported FBCR P2605.1 3. Romex must be supported with in 12'' of panel NEC 334.30 4. Over head garage door buck detail calls out SD-3 "F" there is not detail, There is a "E" detail and that shows anchors must be within 24'' and must be tightened
ALL ROUGH 08/12/2025 APPROVED - AS NOTED MKRASKI
Note: 8/12/25 1. Please check all anchors for overhead garage door bucks to ensure they are tight 2. E-cals duct layout does not match what was installed 3. Please properly seal slab penitration for line set chase (not chase but slab around it) FBC EC R402.4.1.1 Check items at insulation 8/7/25 1. No E-cals on site FBC 107.3.1 2. PLumbing pipes must be properly supported FBCR P2605.1 3. Romex must be supported with in 12'' of panel NEC 334.30 4. Over head garage door buck detail calls out SD-3 "F" there is not detail, There is a "E" detail and that shows anchors must be within 24'' and must be tightened
ALL ROUGH 08/07/2025 Disapproved - NO FEE MKRASKI
Note: 1. No E-cals on site FBC 107.3.1 2. PLumbing pipes must be properly supported FBCR P2605.1 3. Romex must be supported with in 12'' of panel NEC 334.30 4. Over head garage door buck detail calls out SD-3 "F" there is not detail, There is a "E" detail and that shows anchors must be within 24'' and must be tightened
ROOF VALLEY & METAL 08/06/2025 APPROVED MCONTRYMAN
Note: Inspector Notes from Inspection 2450 1. Clear swale/fix temp culvert before next inspection FBC 3303.5 ***Inspection will not be done/passed if item is not repaired*** Inspector Notes from Inspection 2450 1. Clear swale/fix temp culvert before next inspection FBC 3303.5 ***Inspection will not be done/passed if item is not repaired***
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/06/2025 APPROVED MCONTRYMAN
Note: Inspector Notes from Inspection 2450 1. Clear swale/fix temp culvert before next inspection FBC 3303.5 ***Inspection will not be done/passed if item is not repaired*** Inspector Notes from Inspection 2450 1. Clear swale/fix temp culvert before next inspection FBC 3303.5 ***Inspection will not be done/passed if item is not repaired***
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/05/2025 Disapproved - NO FEE MKRASKI
Note: 8/5/25 As prevously noted; Clear swale/fix temp culvert before next inspection FBC 3303.5 *** A full re-inspection is required*** 8/1/25 1. Clear swale/fix temp culvert before next inspection FBC 3303.5 ***Roof sheathing approved only ok to dry in***
WALL SHEATHING 08/05/2025 APPROVED - AS NOTED MKRASKI
Note: 1. Clear swale/fix temp culvert before next inspection FBC 3303.5 ***Inspection will not be done/passed if item is not repaired***
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/01/2025 CANCELLED BY APPLICANT MKRASKI
Note: 1. Clear swale/fix temp culvert before next inspection FBC 3303.5 ***Roof sheathing approved only ok to dry in***
WALL SHEATHING 08/01/2025 CANCELLED BY APPLICANT MKRASKI
Note: 1. Clear swale/fix temp culvert before next inspection FBC 3303.5 ***Roof sheathing approved only ok to dry in***
ROOF SHEATHING 08/01/2025 APPROVED - AS NOTED MKRASKI
Note: 1. Clear swale/fix temp culvert before next inspection FBC 3303.5 ***roof sheathing approved ok to dry in***
FORMBOARD SURVEY (OFFICE USE ONLY) 07/25/2025 APPROVED AMOBLEY
TIE BEAM / LINTEL 07/18/2025 APPROVED - AS NOTED MKRASKI
Note: 1. Clear swale/fix temp culvert before next inspection FBC 3303.5
MONOLITHIC SLAB 07/11/2025 APPROVED JSTEWART
Note: 7/10/2025 - PREVIOUS INSPECTION NOTES 7/10/25: 1). Plans on site are not stamped approved by the City. Please provide approved plans for re-inspection as required. FBC [A]107.3.1 2). Garage footers do not meet plan requirements for 8" wide at bottom most point of footer (and flare out on a 45degree as shown in detail). FBC [A]107.4 3). small area of dirt cave in at front right side plumbing needs to be removed to allow full plan required footer depth. FBC [A]107.4 4). A temporary culvert pipe will need to be installed to allow free flow of ground water through the swale as required. FBC 3303.5 NOTE: If portable toilet is to be shared between neighboring sites, please have it moved towards the middle of the sites to cover both build sites. FBC-P311.1
MONOLITHIC SLAB 07/10/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 7/10/2025 11:05:32 AM *** 7/10/25: 1). Plans on site are not stamped approved by the City. Please provide approved plans for re-inspection as required. FBC [A]107.3.1 2). Garage footers do not meet plan requirements for 8" wide at bottom most point of footer (and flare out on a 45degree as shown in detail). FBC [A]107.4 3). small area of dirt cave in at front right side plumbing needs to be removed to allow full plan required footer depth. FBC [A]107.4 4). A temporary culvert pipe will need to be installed to allow free flow of ground water through the swale as required. FBC 3303.5 NOTE: If portable toilet is to be shared between neighboring sites, please have it moved towards the middle of the sites to cover both build sites. FBC-P311.1
PLUMBING 1ST ROUGH UNDERGROUND 07/07/2025 APPROVED - AS NOTED MGIBSON
Note: REMOVE TREE ROOT BEFORE BACKFILLING ON WATER DISTRIBUTION AND DWV
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 07/03/2025 APPROVED PKNAPIK
WATER METER INSTALLATION REQUEST 06/20/2025 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 08/13/2025 08/13/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/08/2025 07/08/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 07/08/2025 07/08/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 07/02/2025 07/03/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 07/01/2025 07/02/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 05/19/2025 05/22/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SW1 COMPLETE 05/19/2025 05/27/2025
Note: Released By: RODNEY RICKS - (386)986-2001 - RRICKS@PALMCOASTGOV.COM Lot 31 is under construction and I've attached the approved site plan for 43 Whittingham (lot 31). All elevations for the proposed common swale matches within 0.1'. Please ensure the proposed common swale is maintained meeting the COPC standards between both of these lots.
SWALE COMPLETE 05/09/2025 06/02/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
BADMIN COMPLETE 05/08/2025 05/15/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 05/08/2025 05/15/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 05/08/2025 05/15/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC HOLD 05/08/2025 05/12/2025
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spacing in master bedroom behind door. NEC 2020 210.52
ENGIN1 COMPLETE 05/08/2025 05/09/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 05/08/2025 05/13/2025
LOCATE COMPLETE 05/08/2025 05/13/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 05/08/2025 05/13/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 05/08/2025 05/15/2025
Note: Held By: RODNEY RICKS - (386)986-2001 - RRICKS@PALMCOASTGOV.COM Base on the elevations of the PL 27.42' and FL of 27.55' at the back right property line, this will create a low spot. Please revise with flow line being lower than the property line. Note: Lot 31 is under construction by the same builder. Please ensure that a common swale is maintained with positive flow going to the front between both lots. Please feel free to call or email if there are any questions.
ZON COMPLETE 05/08/2025 05/12/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
RSI REINSPECTION 1 ¤35.00 04/13/2026
REINSPECTION RESIDENTIAL ¤40.00 02/13/2026
REINSPECTION RESIDENTIAL ¤40.00 02/13/2026
SW ENG - INSPECTION 20 ¤20.00 02/13/2026
SW ENG - INSPECTION 20 ¤20.00 02/13/2026
SW ENG - INSPECTION 20 ¤20.00 02/13/2026
RSI REINSPECTION 1 ¤35.00 02/13/2026
RSI REINSPECTION 1 ¤35.00 02/13/2026
SW ENG INSPECTION 80 ¤80.00 05/27/2025
SW ENG PRE APRON ¤30.00 05/27/2025
SW ENG - REVIEW 20 ¤20.00 05/27/2025
SW ENG RES REVIEW 200 ¤200.00 05/27/2025
WATER METER W/ TAP ¤2,326.93 05/27/2025
SEWER CREDIT (¤1,147.00) 05/27/2025
WASTEWATER PERM INSPECTION ¤80.00 05/27/2025
WASTEWATER PERM REVIEW ¤25.00 05/27/2025
SEWER CAPITAL FACILITY ¤4,415.00 05/27/2025
WATER CAPITAL FACILITY FEE ¤3,790.49 05/27/2025
WATER PERMIT REVIEW ¤25.00 05/27/2025
WATER MAIN EXTENSION IMPACT ¤917.27 05/27/2025
SITE PLAN 30 ¤30.00 05/27/2025
FC IMPACT FEE EMS ¤62.00 05/27/2025
IMPACT FEE FIRE ¤434.51 05/27/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 05/27/2025
FC IMPACT FEE LIBRARY ¤268.00 05/27/2025
IMPACT FEE PARKS ¤1,828.01 05/27/2025
IMPACT FEE SCHOOL ¤5,450.00 05/27/2025
IMPACT FEE TRANSPORTATION ¤1,916.00 05/27/2025
PEP TANK INSTALL ¤756.74 05/27/2025
WASTEWATER MAIN EXTENSION IMPA ¤2,385.00 05/27/2025
SURCHARGE FS 533.721 ¤8.18 05/27/2025
SURCHARGE - FS 468.631 ¤12.27 05/27/2025
SW ENG - FOUNDATION SURVEY ¤20.00 05/27/2025
WATER- TURN ON ¤50.00 05/27/2025
ADJUSTMENT 10% (¤90.90) 05/27/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 05/27/2025
INSPECTION - RESIDENTIAL ¤684.75 05/27/2025
PLAN REVIEW - RESIDENTIAL ¤194.22 05/27/2025
Fees Total Due: ¤0.00 Total Paid: ¤25,264.47