I want to search for...
Permit #2025050619
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7008-00010-0350 |
| Block: 00010 |
| Subdivision: - |
| Job Phone: 386-212-2958 |
| Location Address: 28 COLE PL |
| Type: PO - POOL |
| Issue Date: 06/12/2025 |
| NOC: RECORDED |
| Applicant name: COBY KYLE MOORE |
| Owner: BENJAMIN ROBERT & ANDREA BARR H&W |
|
Address 28 COLE PL PALM COAST, FL 32137 |
| Lot: 0350 |
| Contracted Stated Job Value: ¤100,000.00 |
| Job Description: Swimming pool |
| Type: CN |
Contractor
CM DESIGNS INC.
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1050 ROBERTS STREET ORMOND BEACH, FL 32174 |
CPC1456991 (Exp: 08/31/2026) | (386)615-7425 | 386-676-2963 |
Sub Contractors
COLE ROBERT WARD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1637 CORDOVA AVE HOLLY HILL, FL 32117 |
EC13012348 (Exp: 08/31/2026) | 386-506-9925 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 02/27/2026 | APPROVED | CVANSTRAHLEN |
| FOOTER | 02/26/2026 | CANCELLED BY INSPECTOR | CVANSTRAHLEN |
| ROW - FINAL INSPECTION | 02/26/2026 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED New inspection due to canceled inspection 2/6/2026 - PREVIOUS INSPECTION NOTES ** 02/06/26 SOD IS STILL REQUIRED TO BE INSTALLED IN THE RIGHT OF WAY (ROW) WHERE ALL BARE EARTH IS THERE MUST BE SOD CUT IN TO MATCH THE EXISTING GRADE. THIS ALSO INCLUDES INTO THE EASMENT AREA BETWEEN 28 AND 30 COLE PL __________________________________________________________________________________________________________________________ NSPECTOR NOTE** BEFORE FINAL ROW INSPECTION ALL BARE GROUND IN ROW MUST HAVE SOD CUT IN TO MATCH EXISTING GRADE AS WELL AS THE BARE GROUND ON ADJOINING PROPERTY IN THE EASMENT. | |||
| ROW - FINAL INSPECTION | 02/20/2026 | CANCELLED BY APPLICANT | WEB |
| Note: 2/6/2026 - PREVIOUS INSPECTION NOTES ** 02/06/26 SOD IS STILL REQUIRED TO BE INSTALLED IN THE RIGHT OF WAY (ROW) WHERE ALL BARE EARTH IS THERE MUST BE SOD CUT IN TO MATCH THE EXISTING GRADE. THIS ALSO INCLUDES INTO THE EASMENT AREA BETWEEN 28 AND 30 COLE PL __________________________________________________________________________________________________________________________ NSPECTOR NOTE** BEFORE FINAL ROW INSPECTION ALL BARE GROUND IN ROW MUST HAVE SOD CUT IN TO MATCH EXISTING GRADE AS WELL AS THE BARE GROUND ON ADJOINING PROPERTY IN THE EASMENT. | |||
| FOOTER | 02/20/2026 | CANCELLED BY APPLICANT | WEB |
| ROW - FINAL INSPECTION | 02/06/2026 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 02/06/26 SOD IS STILL REQUIRED TO BE INSTALLED IN THE RIGHT OF WAY (ROW) WHERE ALL BARE EARTH IS THERE MUST BE SOD CUT IN TO MATCH THE EXISTING GRADE. THIS ALSO INCLUDES INTO THE EASMENT AREA BETWEEN 28 AND 30 COLE PL __________________________________________________________________________________________________________________________ NSPECTOR NOTE** BEFORE FINAL ROW INSPECTION ALL BARE GROUND IN ROW MUST HAVE SOD CUT IN TO MATCH EXISTING GRADE AS WELL AS THE BARE GROUND ON ADJOINING PROPERTY IN THE EASMENT. | |||
| U -UTILITY RESIDENTIAL FINAL | 02/06/2026 | FINAL APPROVED | BHAINES |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/19/2025 | APPROVED | TPOLACEK |
| Note: 11/21/2025 - PREVIOUS INSPECTION NOTES 11-21-25 TPOLACEK*** FINAL SURVEY IS REQUIRED TO HAVE TOPOGRAPHCAL ELEVATIONS 1) The Topographic Survey shall be signed, dated, and sealed by an actively Licensed Florida Professional Surveyor - Mapper. (2) Finished Floor Elevation (FFE) of the living area of all improved structures on adjacent lots. (3) The elevations on all adjacent properties at a minimum of 20-foot intervals on a 10-foot offset outside the property lines. (4) The elevations at 20-foot intervals along all property lines. There must be sufficient elevation shots to indicate the proposed drainage pattern. (5) The interior elevations at no greater than a 20-foot grid. • Shots at the corners, along the sides, rear of the building, and 10 feet off of the building are required in addition to the 20-foot grid. (6) The road centerline (RCL) and edge of pavement (EOP) elevations for roadways adjacent to and along all property lines, including EOP in cul-de-sacs at 9, 12, and 3 o’clock positions. (7) The elevations and/or inverts of all drainage structures within 100 feet of the property lines, including culverts, inlets, swales, weirs, etc. both upstream and downstream of the property. This includes the ditch bottom and top of bank of ditches located on the property or in Reserved Parcels adjacent to the property. (8) All hard elevations are to be expressed to nearest 0.01 foot, all soft/ground elevations may be expressed to the nearest 0.1 of a foot | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 12/19/2025 | APPROVED | TPOLACEK |
| Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 11/21/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 11-21-25 TPOLACEK*** FINAL SURVEY IS REQUIRED TO HAVE TOPOGRAPHCAL ELEVATIONS 1) The Topographic Survey shall be signed, dated, and sealed by an actively Licensed Florida Professional Surveyor - Mapper. (2) Finished Floor Elevation (FFE) of the living area of all improved structures on adjacent lots. (3) The elevations on all adjacent properties at a minimum of 20-foot intervals on a 10-foot offset outside the property lines. (4) The elevations at 20-foot intervals along all property lines. There must be sufficient elevation shots to indicate the proposed drainage pattern. (5) The interior elevations at no greater than a 20-foot grid. • Shots at the corners, along the sides, rear of the building, and 10 feet off of the building are required in addition to the 20-foot grid. (6) The road centerline (RCL) and edge of pavement (EOP) elevations for roadways adjacent to and along all property lines, including EOP in cul-de-sacs at 9, 12, and 3 o’clock positions. (7) The elevations and/or inverts of all drainage structures within 100 feet of the property lines, including culverts, inlets, swales, weirs, etc. both upstream and downstream of the property. This includes the ditch bottom and top of bank of ditches located on the property or in Reserved Parcels adjacent to the property. (8) All hard elevations are to be expressed to nearest 0.01 foot, all soft/ground elevations may be expressed to the nearest 0.1 of a foot | |||
| FOOTER | 11/18/2025 | CANCELLED BY APPLICANT | WEB |
| ELECTRIC AND ALARM | 10/28/2025 | APPROVED - AS NOTED | MKRASKI |
| Note: 1. Ensure all pool circuits are GFCI protected (except for low voltage lighting circuit) FBC 4501.16/NEC 680.21(C)/NEC 680.22 2. Cage must be bonded NEC 680.26(B)(7) 3. Protection of bond wire is required in areas subject to damage NEC 250.64(A)(2) Have repairs made by final | |||
| POOL DECK | 09/05/2025 | APPROVED | MKRASKI |
| STEEL AND GROUND | 07/31/2025 | APPROVED | HCAMACHO |
Review History
| Department | Status | Date In | Date Out |
| ZON | CANCEL | 06/12/2025 | 06/12/2025 |
| Note: forgot to submit another site plan with the correction | |||
| ZON | HOLD | 06/10/2025 | 06/10/2025 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Can not be release as the screen is on hold plans dont match | |||
| ZON | HOLD | 06/03/2025 | 06/03/2025 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Pool permit cannot be released until screen permit is applied for and approved. | |||
| BLD | COMPLETE | 06/03/2025 | 06/09/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 06/03/2025 | 06/04/2025 |
| Note: Released By: EDWARD MADISON - (386)986-4770 - EMADISON@PALMCOASTGOV.COM | |||
| ZON | HOLD | 05/29/2025 | 05/30/2025 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Pool permit cannot be released until screen permit is applied for and approved. | |||
| SW1 | COMPLETE | 05/29/2025 | 05/30/2025 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 05/21/2025 | 05/23/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 05/21/2025 | 05/22/2025 |
| Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO HAVE A MINIMUM OF FLOW ARROWS TO NEW DRAINAGE AFTER POOL IS COMPLETED | |||
| ZON | HOLD | 05/21/2025 | 05/21/2025 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please show pool deck dimensions on proposed site plan to match pool plan. Equipment pad must meet a 5ft setback. Please show this om the proposed site plan as well. Pool permit cannot be released until screen permit is applied for and approved. | |||
| BFLOOD | CANCEL | 05/14/2025 | 05/19/2025 |
| BLD | COMPLETE | 05/14/2025 | 05/19/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 05/14/2025 | 05/19/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | HOLD | 05/14/2025 | 05/15/2025 |
| Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO HAVE A MINIMUM OF FLOW ARROWS TO SHOW NEW DRAINAGE OF THE LOT AFTER POOL IS COMPLETED | |||
| SW1 | HOLD | 05/14/2025 | 05/15/2025 |
| Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO HAVE A MINIMUM OF FLOW ARROWS TO NEW DRAINAGE AFTER POOL IS COMPLETED | |||
| ZON | HOLD | 05/14/2025 | 05/15/2025 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM please show the proposed deck and all dimensions along with the setbacks on the site plan also show the location of the pool equiptment make sure all plans match and also show how the pool will be enclosed on the property. Pool must be fully enclosed by fence (height/material/color as allowed by City Land Development Code) or screen enclosure. A baby fence does not meet the Land Development Code requirements. Please demonstrate the proposed fence meets Land Development Code requirements as per Chapter 4 of the Land Development Code. IF THERE IS TO BE A "FENCE BY OTHERS" THERE MUST BE A FENCE PERMIT (ACKNOWLEDGEMENT BY OWNER OF PROPERTY AS TO FENCE REQUIREMENTS) ON RECORD PRIOR TO ISSUANCE OF A POOL PERMIT. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤20.00 | 02/19/2026 |
| RSI REINSPECTION 1 | ¤35.00 | 02/19/2026 |
| SURCHARGE FS 533.721 | ¤2.41 | 06/12/2025 |
| SURCHARGE - FS 468.631 | ¤3.62 | 06/12/2025 |
| SW ENG INSPECTION 40 | ¤40.00 | 06/12/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 06/12/2025 |
| SITE PLAN 30 | ¤30.00 | 06/12/2025 |
| ADJUSTMENT 10% | (¤26.80) | 06/12/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 06/12/2025 |
| INSPECTION- POOL | ¤160.00 | 06/12/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤78.00 | 06/12/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤392.23 |