I want to search for...

Permit #2025050621

Permit Details

Status: INSPECT

Parcel Id: 10-12-31-0000-00010-0040
Total Square Footage: 75378 sqft
Subdivision: 2328 - OCEAN VILLAGE MF
Job Phone: 904-208-2000
Location Address: 100 OCEAN VILLAGE LN
Type: BM - BUILDING MULTI - APARTMENT
Issue Date: 12/18/2025
NOC: RECORDED
Applicant name: WILLIAM KEITH FAVER
Owner: GJE OV FL100, LLC

Address

PO BOX 3205

VALDOSTA, GA 31064

Contracted Stated Job Value: ¤7,847,129.55
Job Description: BUILDING 1 - 3 STORY - 66 UNIT
Type: CN

Contractor

THE FAVERGRAY COMPANY
Status Location Address Mailing Address State License Number Phone
ACTIVE

415 PABLO AVENUE

JACKSONVILLE, FL 32250

STE200

JACKSONVILLE, FL 32250

CGC1512983 (Exp: 08/31/2026) 904-208-2000

Sub Contractors

TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733
KEVIN DALE CLINARD
Status Location Address State License Number Phone
ACTIVE

1300 RIVER PLACE BLVD SUITE 210

JACKSONVILLE, FL 32207

EC13005227 (Exp: 08/31/2026) 904-207-7707
JOHN ANTHONY BUCCA
Status Location Address State License Number Phone
ACTIVE

6545 TRADE CENTER DRIVE

JACKSONVILLE, FL 32254

CAC1814610 (Exp: 08/31/2026) 904-551-7132
MICHAEL TROY PORTER
Status Location Address State License Number Phone
ACTIVE

710 HAINES STREET

JACKONVILLE , FL 32202

CFC1426859 (Exp: 08/31/2026) 904-262-1066

Inspection History

Type Request Date Result Inspector
ELECTRIC - EARLY POWER 06/10/2026 Approval - Private Provider PPROVIDER
FIREWALL PENETRATIONS 05/15/2026 Approval - Private Provider PPROVIDER
EXTERIOR ARCHITECTURAL FEATURES 05/15/2026 Disapproved -FEE REQUIRED RPICATAGI
Note: 4/30/2026 2:49:01 PM- PREVIOUS INSPECTION NOTES 4/7/2026 1:22:41 PM- PREVIOUS INSPECTION NOTES 3/27/2026 12:27:57 PM- PREVIOUS INSPECTION NOTES 3/23/2026 2:30:21 PM- PREVIOUS INSPECTION NOTES There are no buildings that have been completed. Applocant shall reschedule this inspection ONLY when a building is fully completed. BUILDING IS NO COMPLETED _______________________ REPEAT COMMENT 4/7/2026 RP ---------------------------------------------------------- REPAEAT COMMENT 4/40/2026 BUILDING EXTERIOR NOT YET COMPLETED --------------------------------------------------------------------------------------------------------- Rrepeat Comments -5/15/2026 EXTERIOR IS NO COMPLETE
EXTERIOR ARCHITECTURAL FEATURES 04/30/2026 Disapproved -FEE REQUIRED RPICATAGI
Note: 4/7/2026 1:22:41 PM- PREVIOUS INSPECTION NOTES 3/27/2026 12:27:57 PM- PREVIOUS INSPECTION NOTES 3/23/2026 2:30:21 PM- PREVIOUS INSPECTION NOTES There are no buildings that have been completed. Applocant shall reschedule this inspection ONLY when a building is fully completed. BUILDING IS NO COMPLETED _______________________ REPEAT COMMENT 4/7/2026 RP ---------------------------------------------------------- REPAEAT COMMENT 4/40/2026 BUILDING EXTERIOR NOT YET COMPLETED
EXTERIOR ARCHITECTURAL FEATURES 04/07/2026 Disapproved -FEE REQUIRED RPICATAGI
Note: 3/27/2026 12:27:57 PM- PREVIOUS INSPECTION NOTES 3/23/2026 2:30:21 PM- PREVIOUS INSPECTION NOTES There are no buildings that have been completed. Applocant shall reschedule this inspection ONLY when a building is fully completed. BUILDING IS NO COMPLETED _______________________ REPEAT COMMENT 4/7/2026 RP
FRAMING 03/30/2026 Approval - Private Provider PPROVIDER
ELECTRIC 1ST ROUGH 03/26/2026 Approval - Private Provider PPROVIDER
EXTERIOR ARCHITECTURAL FEATURES 03/26/2026 Disapproved -FEE REQUIRED RPICATAGI
Note: 3/23/2026 2:30:21 PM- PREVIOUS INSPECTION NOTES There are no buildings that have been completed. Applocant shall reschedule this inspection ONLY when a building is fully completed. BUILDING IS NO COMPLETED
ELECTRIC 2ND ROUGH 03/25/2026 Approval - Private Provider PPROVIDER
HVAC ROUGH 03/25/2026 Approval - Private Provider PPROVIDER
PLUMBING 2ND ROUGH 03/25/2026 Approval - Private Provider PPROVIDER
EXTERIOR ARCHITECTURAL FEATURES 03/23/2026 Disapproved -FEE REQUIRED RPICATAGI
Note: There are no buildings that have been completed. Applocant shall reschedule this inspection ONLY when a building is fully completed so tha an architectural inspection can be performed.
HORIZONTAL ASSEMB DRYWALL 03/17/2026
FORMBOARD SURVEY 03/16/2026 APPROVED DLEAP
INSULATION 03/11/2026 Approval - Private Provider PPROVIDER
HORIZONTAL ASSEMB FRAMING 02/17/2026 Approval - Private Provider PPROVIDER
Note: 1/6/2026 3:56:53 PM- PREVIOUS INSPECTION NOTES
ROOF SHEATHING / BRACE / TIE DOWN 01/20/2026 Approval - Private Provider PPROVIDER
FIREWALL FINAL 01/15/2026 Approval - Private Provider PPROVIDER
FIREWALL DRYWALL NAILING 01/13/2026 Approval - Private Provider PPROVIDER
FIREWALL FRAMING 01/13/2026 Approval - Private Provider PPROVIDER
HORIZONTAL ASSEMB FRAMING 01/07/2026 Approval - Private Provider PPROVIDER
ELECTRIC FINAL
LINTEL
PLUMBING 2ND ROUGH
BLD - SEWER TIE IN
PLUMBING FINAL
HVAC ROUGH
HVAC FINAL
ELECTRIC 2ND ROUGH
HORIZONTAL ASSEMB PENETRATIONS
HORIZONTAL ASSEMB FINAL
INSULATION
BUILDING FINAL
FIRE FINAL
EXTERIOR ARCHITECTURAL FEATURES
Note: 5/15/2026 2:36:29 PM- PREVIOUS INSPECTION NOTES 4/30/2026 2:49:01 PM- PREVIOUS INSPECTION NOTES 4/7/2026 1:22:41 PM- PREVIOUS INSPECTION NOTES 3/27/2026 12:27:57 PM- PREVIOUS INSPECTION NOTES 3/23/2026 2:30:21 PM- PREVIOUS INSPECTION NOTES There are no buildings that have been completed. Applocant shall reschedule this inspection ONLY when a building is fully completed. BUILDING IS NO COMPLETED _______________________ REPEAT COMMENT 4/7/2026 RP ---------------------------------------------------------- REPAEAT COMMENT 4/40/2026 BUILDING EXTERIOR NOT YET COMPLETED --------------------------------------------------------------------------------------------------------- Rrepeat Comments -5/15/2026 EXTERIOR IS NO COMPLETE
WATER METER INSTALLATION REQUEST
U-CROSS CONNECTION
U - UTILITY COMMERCIAL FINAL
U -UTILITY RESIDENTIAL FINAL

Review History

Department Status Date In Date Out
PLLA PENDING 06/09/2026
ELEC COMPLETE 06/09/2026 06/10/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC HOLD 06/03/2026 06/05/2026
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Can not read the electric vehicle supply that was pasted on the plans.
DSD COMPLETE 06/03/2026 06/03/2026
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BADMIN INFORMATION 05/14/2026 05/14/2026
Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Inspection report needs to be a pass or fail and please be specfic with the code as there seems to be two codes on this report and all inspection need to be requested before submittal.
ELEC HOLD 03/30/2026 04/01/2026
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Can not read the electric vehicle supply that was pasted on the plans.
PLLA HOLD 03/30/2026 04/14/2026
Note: Held By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM PROVIDE LANDSCAPE PLAN FOR FOUNDATION PLANTINGS SURROUNDING THE BUILDING
BADMIN INFORMATION 03/25/2026 03/25/2026
Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM PPI rejected doesn't have any result code.
PLENG COMPLETE 03/16/2026 03/16/2026
Note: Released By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM
PLENG HOLD 02/20/2026 02/20/2026
Note: Held By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM 1. Show building ties to property lines.
DSD COMPLETE 12/12/2025 12/12/2025
Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM
DSD HOLD 08/29/2025 09/03/2025
Note: Held By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM 1. Prior to issuance of building permits, all life- safety facilities necessary to support access and safety of the site by first responders must be in place completed and functioning for their intended purpose. These life-safety facilities are in addition to water, wastewater and stormwater facilities (including DEP certification), fire-protection and, at a minimum, stabilized fire access roads.
MECH COMPLETE 08/29/2025 09/09/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
PLUM COMPLETE 08/29/2025 09/09/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
FI1 COMPLETE 08/29/2025 09/11/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
DSD HOLD 07/31/2025 08/04/2025
Note: Held By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM Held By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM 1. Prior to issuance of building permits, all life- safety facilities necessary to support access and safety of the site by first responders must be in place completed and functioning for their intended purpose. These life-safety facilities are in addition to water, wastewater and stormwater facilities (including DEP certification), fire-protection and, at a minimum, stabilized fire access roads. 2. Commercial Project Site Improvement Permit must be issued and inspections must pass before release of permits to go vertical.
ELEC COMPLETE 07/31/2025 08/13/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
FI1 HOLD 07/31/2025 08/13/2025
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM All comments below per the 8th edition Florida Fire Prevention Code and / or the 2023 Florida Building Code-Building Please provide a written response to each comment below in a response letter and provide clouded response changes on plan sheets and add page locations for each response. Provide note on plans that fire alarm and fire sprinkler will be on a separate permit. 1. Need to update NFPA 101 and 1 code year 2. Please provide detail for Fire Fighter Safety Building Marking System per Florida Administrative Code 69A-3.012 and Florida Statutes 633.027 3. Please provide engineering design for fire sprinkler systems and fire alarm systems as part of these submitted plans. A Florida licensed professional engineer is responsible to establish design concepts established through the Responsibility Rules adopted by the Florida Board of Professional Engineers. F.S. 633.102 (19). Layout of risers, cross mains, branch lines, sprinkler heads, sizing of pipe, hanger locations, and hydraulic calculations in accordance with the design concepts established by the engineer are provided by the licensed fire protection contractor under separate building permit for installation of fire sprinkler and fire alarm systems 4. Please establish a written fire safety plan for safeguards during construction per 8th edition (2023) FFPC 1, 16.4.1.1, 16.4.1.2.(1) through (8), and NFPA 241 (2013). and FBCB Chapter 33. The plan, at a minimum, shall include details for fire extinguishers per FBCB Section 3309, means of egress per FBCB Section 3310, standpipes per Section 3311, and water supply for fire protection per FBCB Section 3313. The plan shall also address, at a minimum, housekeeping, on-site security, pre-fire planning, access for firefighting, stairs, standpipes and fire protection during construction. The plan is subject to review. 5. Please provide plans for the security fence during construction per FFPC 8th edition (2023) 1, 16.4.2.5.4 and the AHJ [241:7.2.5.4] Please use the following information to obtain a properly keyed Knox Padlock… Please select FLAGLER COUNTY DEPT. of EMERGENCY MANAGEMENT, for jurisdiction or agency even though it is going in the city. This way it will get it keyed correctly. https://www.knoxbox.com/Products/Commercial-KnoxBoxes
UD1 COMPLETE 07/31/2025 08/14/2025
Note: Released By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM
MECH HOLD 07/31/2025 08/13/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM ALL COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING, FLORIDA BUILDING CODE-MECHANICAL AND FLORIDA BUILDING CODE -ENERGY CONSERVATION. RESUBMITTED PLAN PAGES NEED TO BE CLOUDED AND MUST HAVE A RESPONSE LETTER FROM THE ENGINEER SIGNED AND SEALED. PARTIAL REPEAT COMMENT: 13. Provide details showing length of dryer vent not to excced 35 Feet. If exceeds 35 Feet, provide manufacturers specs on dryers to be installed. 504.9.4, 504.9.4.2 FBC Mechanical (MANUFACTURERS SPECS DO NOT SHOW THE MODEL NUMBER OF THE DRYER TO BE USED. PROVIDE MODEL OF DRYER.) REPEAT COMMENT: 14. If dryer vent over 35 Feet provide details on permanent tag per 504.9.5 FBC Mechanical (NO PLAN DETAIL SHOWING PERMANENT TAG WITH LOCATION AND WORDING FOR LONG VENT APPLICATION)
PLUM HOLD 07/31/2025 08/13/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-PLUMBING (FBCP), FLORIDA BUILDING CODE-ACCESSIBILITY (FBCA), FLORIDA STATUTES (F.S.), FLORIDA ADMINISTRATIVE CODE (F.A.C.) AND AUTHORITY HAVING JURISDICTION (A.H.J.). RESUBMITTED PLAN PAGES NEED TO BE CLOUDED AND MUST HAVE A RESPONSE LETTER FROM THE ENGINEER SIGNED AND SEALED. REPEAT COMMENT: 1. All plumbing plan pages need a verifiable digital signature F.S. 471-025 (NO NEW PLUMBING PLAN SHEETS UPLOADED)
BLD COMPLETE 07/31/2025 08/13/2025
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
ARCHR COMPLETE 05/14/2025 05/30/2025
Note: Released By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM
BLD HOLD 05/14/2025 07/09/2025
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM ALL COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING (FBCB), FLORIDA BUILDING CODE-ACCESSIBILITY (FBCA), FLORIDA BUILDING CODE-PLUMBING (FBCP), FLORIDA STATUTES (FS), FLORIDA ADMINISTRATIVE CODE (FAC) AND AUTHORITY HAVING JURISDICTION (AHJ). PLAN RE-SUBMITTAL SHALL BE ACCOMPANIED BY A RESPONSE LETTER SIGNED AND SEALED BY THE APPROPRIATE DESIGN PROFESSIONAL(S). ALL PLAN REVISIONS SHALL BE CLOUDED APPROPRIATELY. 1.Provide list of deferred submittals. Engineered truss plans not provided, list them as a deferred submittal. Pre-manufactured guards, stairs and similar. FBCB Section 107.3.4.1 2. Provide City of Palm Coast Roofing Worksheet - FL# 18374-R4 not valid. 3. All structural plan sheets shall be digitally signed, sealed, and verifiable. FAC 65G15-23.004. Be sure digital seals include the required language in this FAC section. 4. Plan Sheet A520 references 1/A513 for more information. Sheet not attached. 5. Plan Sheet A010 under Fire Protection for (Mix 1). Under Florida Building Code you have Sprinklered NFPA 13R, under Florida Fire Prevention you have Sprinklered NFPA 13. Which one is correct? 6. Construction type VA requires fire resistible rated exterior walls both bearing and non bearing regardless of location and fire separation distance. None of the plan sheets indicate fire resistive rated exterior walls. FBCB Section 602.1, Table 602.1 (see footnote e.), 705.5 and Table 705.5. Exterior walls whit a fire separation distance greater than 10 feet shall be rated for fire exposure from inside the inside. 7. Plan Sheet A060- Notes refer to FBC 7th Edition. Please update to current code cycle. 8. Plan Sheet A455 - Details 1 and 2 reference 5/A601a - sheet not attached. 9. Plan Sheet A227- Attic Ventilation Notes - Reference FCBC 7th Ed. 2020. Please update to current code cycle. 10. Plan Sheet A560 - References 1/A500 for additional information. Plan sheet not attached. 11. Provide site plan with distances between buildings for Fire separation distance FBC 705.6 12. Provide list of special inspections required for threshold building.
DSD HOLD 05/14/2025 05/22/2025
Note: Held By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM Prior to issuance of permit infrastructure to support the life and safety issues must be met but not limit to waste water certification, fire protection, stabilized roads. a. A staging plan. The staging plan must show the order these buildings will be CO’d. b. Show Ingress and egress. c. Please provide a note on the plans stating: The required fire hydrants and supply will be installed, tested, and in service for prior to combustible materials being delivered per FFPC 1, section 16.5.3 d. Show stabilized road. Stabilized access roads shall be maintained by the project developer and deficiencies observed by the Palm Coast Fire Department shall be promptly corrected to the satisfaction of the Palm Coat Fire Department. e. Temporary Cul-de-sac for fire trucks (as applicable). If a Cul-da-sac is needed add a note to your temporary cul-de-sac detail that the roadway must be able to support a 75,000-pound vehicle. f. Denote and map area for FDEP partial clearance for water main on-site plan. g. A sign is required to be located on building location stating the following: “NOTICE: DO NOT CONNECT WATER OR SEWER LINES”. This sign should be in English and Spanish. (See Exhibit B). Signs are required to be maintained and always in vertical position. If this site has a SWPPP on file all requirements listed in this plan must be met to include the stabalization of areas not to be built on with seeds. h. Issuance of permits shall also conform to requirements of other City departments and divisions. When submitting for a modification to the DO submit all pictures with the signs posted on each proposed building location, DEP clearance and all test preformed on the waste water system.
ELEC HOLD 05/14/2025 05/28/2025
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need note on plan for all equipment rooms. NEC 2020 110.26(C) (3) 2. Equipment rooms need to comply with NEC 2020 110.26 (E)(1) 3. Plans need to be digitally signed and sealed.
FI1 HOLD 05/14/2025 05/29/2025
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM All comments below per the 8th edition Florida Fire Prevention Code and / or the 2023 Florida Building Code-Building Please provide a written response to each comment below in a response letter and provide clouded response changes on plan sheets and add page locations for each response. Provide note on plans that fire alarm and fire sprinkler will be on a separate permit. 1. Need to update NFPA 101 and 1 code year 2. Please provide detail for Fire Fighter Safety Building Marking System per Florida Administrative Code 69A-3.012 and Florida Statutes 633.027 3. Please provide engineering design for fire sprinkler systems and fire alarm systems as part of these submitted plans. A Florida licensed professional engineer is responsible to establish design concepts established through the Responsibility Rules adopted by the Florida Board of Professional Engineers. F.S. 633.102 (19). Layout of risers, cross mains, branch lines, sprinkler heads, sizing of pipe, hanger locations, and hydraulic calculations in accordance with the design concepts established by the engineer are provided by the licensed fire protection contractor under separate building permit for installation of fire sprinkler and fire alarm systems 4. Please establish a written fire safety plan for safeguards during construction per 8th edition (2023) FFPC 1, 16.4.1.1, 16.4.1.2.(1) through (8), and NFPA 241 (2013). and FBCB Chapter 33. The plan, at a minimum, shall include details for fire extinguishers per FBCB Section 3309, means of egress per FBCB Section 3310, standpipes per Section 3311, and water supply for fire protection per FBCB Section 3313. The plan shall also address, at a minimum, housekeeping, on-site security, pre-fire planning, access for firefighting, stairs, standpipes and fire protection during construction. The plan is subject to review. 5. Please provide plans for the security fence during construction per FFPC 8th edition (2023) 1, 16.4.2.5.4 and the AHJ [241:7.2.5.4] Please use the following information to obtain a properly keyed Knox Padlock… Please select FLAGLER COUNTY DEPT. of EMERGENCY MANAGEMENT, for jurisdiction or agency even though it is going in the city. This way it will get it keyed correctly. https://www.knoxbox.com/Products/Commercial-KnoxBoxes 6. Please include the following code versions the plan sheets anywhere they appear on the plans FBC 8th edition (2023) FFPC 8th edition (2023) Florida Fire Prevention Code with the Florida specific NFPA 1 and 101 NFPA 10, (2018) edition, Standard for Portable Fire Extinguishers NFPA 13R, (2019) edition, Standard for the Installation of Sprinkler Systems in Low-Rise Residential Occupancies NFPA 72, (2019) edition, National Fire Alarm and Signaling Code NFPA 70, (2020) edition, National Electrical Code
GAS CANCEL 05/14/2025 05/23/2025
MECH HOLD 05/14/2025 06/09/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM ALL COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING, FLORIDA BUILDING CODE-MECHANICAL AND FLORIDA BUILDING CODE -ENERGY CONSERVATION. RESUBMITTED PLAN PAGES NEED TO BE CLOUDED AND MUST HAVE A RESPONSE LETTER FROM THE ENGINEER SIGNED AND SEALED. 1. Requirements need to be 100% addressed in comcheck. 107.2.1 FBC 2. All Mechanical plan pages need to have a verifiable digital signature. 471.025 3. Provide the Effective dispersal volume charge per 7.2 Ashrae 15. Show calculation for all systems including common areas. If Refrigerant charge exceeds the EDVC, then show compliance with #4, 5, 6, and 7 below. 4. Provide means of refrigerant detector per 1105.3 FBC Mechanical 5. Provide means of ventilation per 1105.6 and discharge location 1105.6.1 and makeup air 1105.6.2 FBC Mechanical or Ashrae 15 6. Provide details on remote controls of mechanical equipment and refrigerant system shutoff and ventilation system in machinery rooms per 1106.5,1106.5.1,1106.5.2 FBC Mechanical 7. Provide details that show machinery room complies with class 1 division 2. 1106.4 FBC Mechanical or Ashrae 15 8. Provide Heatload Calculation per C403.2.1 FBC Energy Conservation 9. Provide manufacturers specs on fire dampers per 607.2 FBC Mechanical 10. Provide Ventilation calculation per Table 403.3.1.1 FBC Mechanical 11. Provide details on a permanent ladder per 306.5. FBC Mechanical 12. Provide details on roof guards per 304.11 FBC Mechanical 13. Provide details showing length of dryer vent not to excced 35 Feet. If exceeds 35 Feet, provide manufacturers specs on dryers to be installed. 504.9.4, 504.9.4.2 FBC Mechanical 14. If dryer vent over 35 Feet provide details on permanent tag per 504.9.5 FBC Mechanical
UD1 HOLD 05/14/2025 05/29/2025
Note: Held By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM Please refer to Utility (water & sewer) comments made by Development Services Reviewer
PLUM HOLD 05/14/2025 06/10/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-PLUMBING (FBCP), FLORIDA BUILDING CODE-ACCESSIBILITY (FBCA), FLORIDA STATUTES (F.S.), FLORIDA ADMINISTRATIVE CODE (F.A.C.) AND AUTHORITY HAVING JURISDICTION (A.H.J.). RESUBMITTED PLAN PAGES NEED TO BE CLOUDED AND MUST HAVE A RESPONSE LETTER FROM THE ENGINEER SIGNED AND SEALED. 1. All plumbing plan pages need a verifiable digital signature F.S. 471-025

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
FC IMPACT FEE LAW ENFORCEMENT ¤7,326.00 12/18/2025
FC IMPACT FEE LIBRARY ¤9,174.00 12/18/2025
ADJUSTMENT 10% (¤1,302.42) 12/18/2025
ADMINISTRATIVE - COMMERCIAL PP ¤3,000.00 12/18/2025
ADMINISTRATIVE - COMMERCIAL ¤75.00 12/18/2025
INSPECTION - FIRE COMMERCIAL ¤1,962.00 12/18/2025
PLAN REVIEW - COMMERCIAL ¤10,987.20 12/18/2025
FC IMPACT FEE EMS ¤2,112.00 12/18/2025
SURCHARGE FS 533.721 ¤147.22 12/18/2025
SURCHARGE - FS 468.631 ¤220.83 12/18/2025
SITE PLAN 30 ¤30.00 12/18/2025
IMPACT FEE FIRE ¤28,677.66
IMPACT FEE PARKS ¤120,648.66
IMPACT FEE TRANSPORTATION ¤133,188.00
REINSPECTION- SITE INSPECTOR ¤40.00
REINSPECTION- SITE INSPECTOR ¤40.00
REINSPECTION- SITE INSPECTOR ¤40.00
REINSPECTION- SITE INSPECTOR ¤40.00
REINSPECTION- SITE INSPECTOR ¤40.00
Fees Total Due: ¤282,714.32 Total Paid: ¤33,731.83