| Location Address: 11 KASLO CT |
| Type: PO - POOL |
| Issue Date: 05/20/2025 |
| NOC: RECORDED |
| Applicant name: SAMANTHA JESSICA ALEXANDER |
| Owner: MROCHKO TARAS & TETIANA H&W |
|
Address 63 WOOD HEAVEN DR PALM COAST, FL 32164 |
| Lot: 0120 |
| Contracted Stated Job Value: ¤80,000.00 |
| Job Description: SWIMMING POOL W/ SCREEN ENCLOSURE REF # 2024030295 |
| Type: CN |
| Original Permit #: 2024030295 |
Contractor
AGUA POOLS AND SPA INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3438 LONGLEAF ROAD , |
CPC1459907 (Exp: 08/31/2026) | 386-492-6910 |
Sub Contractors
CHARLES K DAVIS
| Status | Location Address | State License Number | Phone |
| INACTIVE |
1410 RIDGEWOOD AVE HOLLY HILL, FL 32117 |
EC13011552 (Exp: 08/31/2026) | 386-236-9610 |
WILLIAM CARL KLESS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
597 PLEASANT STREET LAKE HELEN, FL 32744 |
CBC1251835 (Exp: 08/31/2026) | 386-228-8933 |
CHARLES K DAVIS
| Status | Location Address | State License Number | Phone |
| INACTIVE |
1410 RIDGEWOOD AVE HOLLY HILL, FL 32117 |
EC13011552 (Exp: 08/31/2026) | 386-236-9610 |
WILLIAM CARL KLESS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
597 PLEASANT STREET LAKE HELEN, FL 32744 |
CBC1251835 (Exp: 08/31/2026) | 386-228-8933 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 10/28/2025 | CANCELLED BY APPLICANT | WEB |
| POOL FINAL | 10/27/2025 | FINAL APPROVED | BTAYLOR |
| U -UTILITY RESIDENTIAL FINAL | 10/23/2025 | FINAL APPROVED | BHAINES |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 10/21/2025 | APPROVED - AS NOTED | FSLADISH |
| Note: 10/21/25 MET WITH BUILDER TO LOOK AT DRAINAGE IN THE FIELD. UPON WALKING PROPERTY DETERMINED DRAINAGE WILL WORK. SMALL FLAT SPOT BUT IN THE FIELD IT HAS POSITIVE DRAINAGE. 9/29/2025 - PREVIOUS INSPECTION NOTES 9/29/25 YOUR RESUBMITTED SURVEY SHOWS THAT YOU STILL DO NOT HAVE POSITIVE DRAINAGE FLOW LEFT AND RIGHT OFF OF THE REAR OF YOUR POOL DECK THAT YOU INDICATED WOULD BE . PLEASE SEE PHOTO FOR REFERENCE. REAR YARD DRAIAGE Section 300.01 C(6) V-16 "6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement." 5/23/2025 - PREVIOUS INSPECTION NOTES 5/23/25 YOUR SITE PLAN SHOWS THE DRAINAGE FLOWING OFF THE POOL AND SHEDDING LEFT AND RIGHT TO THE FRONT SWALE. YOUR FINAL SURVEY SHOWS THAT THERE IS NO POSITIVE FLOW YOU ARE SHOWING A ELEVATION SHOT OF 20.00 BETWEEN TWO SHOTS OF 20.70. BOTH SIDES OF THE POOL CORNERS SHOW THE DRAINAGE GOING UHILL. THIS WILL NOT ALLOW DRAINAGE TO GET TO THE FRONT SWALE. PLEASE SEE PHOTO FOR REFERENCE. POSITIVE FALL .10 EVERY 20 FT. Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 feeT The rear yard is required to drain to the front Sec 300.01 C-6 Sec 300.01 C-6=Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 10/21/2025 | APPROVED | FSLADISH |
| Note: 10/21/25 MET WITH BUILDER TO LOOK AT DRAINAGE IN THE FIELD. UPON WALKING PROPERTY DETERMINED DRAINAGE WILL WORK. SMALL FLAT SPOT BUT IN THE FIELD IT HAS POSITIVE DRAINAGEInspector Notes from Inspection 9463 10/21/25 MET WITH BUILDER TO LOOK AT DRAINAGE IN THE FIELD. UPON WALKING PROPERTY DETERMINED DRAINAGE WILL WORK. SMALL FLAT SPOT BUT IN THE FIELD IT HAS POSITIVE DRAINAGE. 9/29/2025 - PREVIOUS INSPECTION NOTES 9/29/25 YOUR RESUBMITTED SURVEY SHOWS THAT YOU STILL DO NOT HAVE POSITIVE DRAINAGE FLOW LEFT AND RIGHT OFF OF THE REAR OF YOUR POOL DECK THAT YOU INDICATED WOULD BE . PLEASE SEE PHOTO FOR REFERENCE. REAR YARD DRAIAGE Section 300.01 C(6) V-16 "6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement." 5/23/2025 - PREVIOUS INSPECTION NOTES 5/23/25 YOUR SITE PLAN SHOWS THE DRAINAGE FLOWING OFF THE POOL AND SHEDDING LEFT AND RIGHT TO THE FRONT SWALE. YOUR FINAL SURVEY SHOWS THAT THERE IS NO POSITIVE FLOW YOU ARE SHOWING A ELEVATION SHOT OF 20.00 BETWEEN TWO SHOTS OF 20.70. BOTH SIDES OF THE POOL CORNERS SHOW THE DRAINAGE GOING UHILL. THIS WILL NOT ALLOW DRAINAGE TO GET TO THE FRONT SWALE. PLEASE SEE PHOTO FOR REFERENCE. POSITIVE FALL .10 EVERY 20 FT. Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 feeT The rear yard is required to drain to the front Sec 300.01 C-6 Sec 300.01 C-6=Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement. | |||
| ROW - FINAL INSPECTION | 10/21/2025 | APPROVED | FSLADISH |
| Note: 10/21/25 MET WITH BUILDER TO LOOK AT DRAINAGE IN THE FIELD. UPON WALKING PROPERTY DETERMINED DRAINAGE WILL WORK. SMALL FLAT SPOT BUT IN THE FIELD IT HAS POSITIVE DRAINAGE. NO ROW DAMAGE. | |||
| ROW- PROJECT STATUS | 10/21/2025 | APPROVED | FSLADISH |
| Note: 10/21/25 MET WITH BUILDER TO LOOK AT DRAINAGE IN THE FIELD. UPON WALKING PROPERTY DETERMINED DRAINAGE WILL WORK. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 09/29/2025 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 9/29/25 YOUR RESUBMITTED SURVEY SHOWS THAT YOU STILL DO NOT HAVE POSITIVE DRAINAGE FLOW LEFT AND RIGHT OFF OF THE REAR OF YOUR POOL DECK THAT YOU INDICATED WOULD BE . PLEASE SEE PHOTO FOR REFERENCE. REAR YARD DRAIAGE Section 300.01 C(6) V-16 "6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement." 5/23/2025 - PREVIOUS INSPECTION NOTES 5/23/25 YOUR SITE PLAN SHOWS THE DRAINAGE FLOWING OFF THE POOL AND SHEDDING LEFT AND RIGHT TO THE FRONT SWALE. YOUR FINAL SURVEY SHOWS THAT THERE IS NO POSITIVE FLOW YOU ARE SHOWING A ELEVATION SHOT OF 20.00 BETWEEN TWO SHOTS OF 20.70. BOTH SIDES OF THE POOL CORNERS SHOW THE DRAINAGE GOING UHILL. THIS WILL NOT ALLOW DRAINAGE TO GET TO THE FRONT SWALE. PLEASE SEE PHOTO FOR REFERENCE. POSITIVE FALL .10 EVERY 20 FT. Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 feeT The rear yard is required to drain to the front Sec 300.01 C-6 Sec 300.01 C-6=Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/23/2025 | Disapproved - NO FEE | FSLADISH |
| Note: 5/23/25 YOUR SITE PLAN SHOWS THE DRAINAGE FLOWING OFF THE POOL AND SHEDDING LEFT AND RIGHT TO THE FRONT SWALE. YOUR FINAL SURVEY SHOWS THAT THERE IS NO POSITIVE FLOW YOU ARE SHOWING A ELEVATION SHOT OF 20.00 BETWEEN TWO SHOTS OF 20.70. BOTH SIDES OF THE POOL CORNERS SHOW THE DRAINAGE GOING UHILL. THIS WILL NOT ALLOW DRAINAGE TO GET TO THE FRONT SWALE. PLEASE SEE PHOTO FOR REFERENCE. POSITIVE FALL .10 EVERY 20 FT. Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 feeT The rear yard is required to drain to the front Sec 300.01 C-6 Sec 300.01 C-6=Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement. | |||
| ELECTRIC AND ALARM | 07/18/2024 | APPROVED | BTAYLOR |
| FOOTER | 06/11/2024 | APPROVED | RSIMS |
| POOL DECK | 06/11/2024 | APPROVED | RSIMS |
| STEEL AND GROUND | 05/22/2024 | APPROVED | BTAYLOR |
| Note: 5/21/2024 - PREVIOUS INSPECTION NOTES 5/21/24: 1). Deep end of the floor: Rebar is under water so clearance to earth cannot be verified. 2). Please add more cement blocks or chairs to maintain 3" bar clearance. | |||
| STEEL AND GROUND | 05/21/2024 | Disapproved - NO FEE | RSIMS |
| Note: 5/21/24: 1). Deep end of the floor: Rebar is under water so clearance to earth cannot be verified. 2). Please add more cement blocks or chairs to maintain 3" bar clearance. |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | INFORMATION | 04/07/2025 | 04/07/2025 |
| Note: Marked INFORMATION By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM no extension granted per the CBO as no justification or explanation has been provided as to why the extension is necessary. | |||
| ZON | COMPLETE | 04/23/2024 | 04/23/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/23/2024 | 04/29/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | HOLD | 04/16/2024 | 04/17/2024 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM All Screen plan dimensions do not match deck dimensions | |||
| SW1 | COMPLETE | 04/16/2024 | 04/22/2024 |
| Note: Released By: TOM POLACEK - (386)346-8986 - | |||
| ZON | HOLD | 04/11/2024 | 04/12/2024 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please use the final survey and show the pool and deck with dimensions and setbacks | |||
| BLD | COMPLETE | 04/11/2024 | 04/15/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | HOLD | 04/02/2024 | 04/02/2024 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM in the new screen enclosure plan looks like the sceen dimension got larger instead of what we discussed as per last phone conversation. Plans must match | |||
| ZON | HOLD | 03/26/2024 | 03/26/2024 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM please adjust the site plans and include all dimension and setbacks from the property line as you are litterally on the 6.5' setback. you changed the setback and did not make changes to the site plan. But your pool plan needs to be clear of all the dimesions the site plan needs to match all of the that and the screen enclosure needs to reflect all thos changes. As the site plan appears this has not been addressed. | |||
| SW1 | COMPLETE | 03/26/2024 | 04/02/2024 |
| Note: Released By: FRANK SLADISH - (386)871-6113 - FSLADISH@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/26/2024 | 04/01/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/07/2024 | 03/14/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 03/07/2024 | 03/14/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 03/07/2024 | 03/12/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 03/07/2024 | 03/15/2024 |
| Note: Released By: TOM POLACEK - (386)346-8986 - | |||
| ZON | HOLD | 03/07/2024 | 03/07/2024 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site plan :1. Rear setback of 6 ' does not meet the the SFR-2 set back of 6.5' provide the setback from the deck to the property line at the closest point. Please provide all three setbacks to the property line. 2. provide the dimension of the left side of pool on site plan Screen plans need to match pool plans . All plans must match |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 10% | (¤19.00) | 05/20/2025 |
| ADMINISTRATIVE - EXTENSION | ¤40.00 | 05/20/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 05/20/2025 |
| INSPECTION- POOL | ¤160.00 | 05/20/2025 |
| SURCHARGE FS 533.721 | ¤2.00 | 05/20/2025 |
| SURCHARGE - FS 468.631 | ¤2.57 | 05/20/2025 |
| SW ENG INSPECTION 40 | ¤40.00 | 05/20/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤255.57 |