I want to search for...

Permit #2025050879

Permit Details

Status: INSPECT

Parcel Id: 10-12-31-0000-00010-0040
Total Square Footage: 80960 sqft
Subdivision: 2328 - OCEAN VILLAGE MF
Job Phone: 904-208-2000
Location Address: 400 OCEAN VILLAGE CIR
Type: BM - BUILDING MULTI - APARTMENT
Issue Date: 02/10/2026
NOC: RECORDED
Applicant name: WILLIAM KEITH FAVER
Owner: GJE OV FL100, LLC

Address

PO BOX 3205

VALDOSTA, GA 31064

Contracted Stated Job Value: ¤8,338,971.65
Job Description: BUILDING 4 - 4-STORY - 72 UNIT
Type: CN

Contractor

THE FAVERGRAY COMPANY
Status Location Address Mailing Address State License Number Phone
ACTIVE

415 PABLO AVENUE

JACKSONVILLE, FL 32250

STE200

JACKSONVILLE, FL 32250

CGC1512983 (Exp: 08/31/2026) 904-208-2000

Sub Contractors

MICHAEL TROY PORTER
Status Location Address State License Number Phone
ACTIVE

710 HAINES STREET

JACKONVILLE , FL 32202

CFC1426859 (Exp: 08/31/2026) 904-262-1066
KEVIN DALE CLINARD
Status Location Address State License Number Phone
ACTIVE

1300 RIVER PLACE BLVD SUITE 210

JACKSONVILLE, FL 32207

EC13005227 (Exp: 08/31/2026) 904-207-7707
TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733

Inspection History

Type Request Date Result Inspector
ELECTRIC 1ST ROUGH 05/15/2026
FIREWALL PENETRATIONS 05/15/2026
INSULATION 05/14/2026 Approval - Private Provider PPROVIDER
FIREWALL DRYWALL NAILING 05/12/2026
HORIZONTAL ASSEMB DRYWALL 05/12/2026
PLUMBING 1ST ROUGH 04/22/2026
FORMBOARD SURVEY 03/17/2026 APPROVED DLEAP
ROOF SHEATHING / BRACE / TIE DOWN 03/17/2026 Approval - Private Provider PPROVIDER
HORIZONTAL ASSEMB FRAMING 03/11/2026 Approval - Private Provider PPROVIDER
FIREWALL FRAMING 03/11/2026 Approval - Private Provider PPROVIDER
FIREWALL FINAL
HORIZONTAL ASSEMB PENETRATIONS
HORIZONTAL ASSEMB FINAL
PLUMBING 2ND ROUGH
BLD - SEWER TIE IN
PLUMBING FINAL
HVAC ROUGH
HVAC FINAL
ELECTRIC 2ND ROUGH
ELECTRIC FINAL
MONOLITHIC SLAB
LINTEL
FRAMING
INSULATION
BUILDING FINAL
FIRE FINAL
EXTERIOR ARCHITECTURAL FEATURES
WATER METER INSTALLATION REQUEST
U-CROSS CONNECTION
U - UTILITY COMMERCIAL FINAL
U -UTILITY RESIDENTIAL FINAL

Review History

Department Status Date In Date Out
PLLA PENDING 06/09/2026
ELEC COMPLETE 06/09/2026 06/10/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
DSD COMPLETE 06/03/2026 06/03/2026
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ELEC HOLD 06/03/2026 06/05/2026
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Can not read the electric vehicle supply that was pasted on the plans.
BADMIN INFORMATION 05/14/2026 05/14/2026
Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Inspection code 3440 not scheduled, please schedule before submitting and provide a pass or fail for each inspection not just a partial when ther are two codes provided
ELEC HOLD 03/30/2026 04/01/2026
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Can not read the electric vehicle supply that was pasted on the plans.
PLLA HOLD 03/30/2026 04/14/2026
Note: Held By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM Provide landscape and irrigation plans for building and vicinity
PLENG COMPLETE 03/17/2026 03/17/2026
Note: Released By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM
PLENG HOLD 02/20/2026 02/20/2026
Note: Held By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM 1. Show building ties to property lines.
DSD COMPLETE 12/12/2025 12/12/2025
Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM
FI1 COMPLETE 09/26/2025 09/26/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 09/26/2025 10/06/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
DSD HOLD 09/26/2025 09/29/2025
Note: Held By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM 1. Prior to issuance of building permits, all life- safety facilities necessary to support access and safety of the site by first responders must be in place completed and functioning for their intended purpose. These life-safety facilities are in addition to water, wastewater (including DEP certification), fire-protection and, at a minimum, stabilized fire access roads. 2. Commercial Project Site Improvement Permit must be issued and inspections must pass before release of permits to go vertical.
DSD HOLD 09/05/2025 09/16/2025
Note: Held By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM 1. Prior to issuance of building permits, all life- safety facilities necessary to support access and safety of the site by first responders must be in place completed and functioning for their intended purpose. These life-safety facilities are in addition to water, wastewater and stormwater facilities (including DEP certification), fire-protection and, at a minimum, stabilized fire access roads. 2. Commercial Project Site Improvement Permit must be issued and inspections must pass before release of permits to go vertical.
MECH HOLD 09/05/2025 09/15/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM PARTIAL REPEAT COMMENT: 13. Provide details showing length of dryer vent not to excced 35 Feet. If exceeds 35 Feet, provide manufacturers specs on dryers to be installed. 504.9.4, 504.9.4.2 FBC Mechanical (NEED TO UPLOAD MANUFACTURERS SPECS TO PERMIT)
PLUM COMPLETE 09/05/2025 09/15/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
FI1 HOLD 09/05/2025 09/12/2025
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM All comments below per the 8th edition Florida Fire Prevention Code and / or the 2023 Florida Building Code-Building Please provide a written response to each comment below in a response letter and provide clouded response changes on plan sheets and add page locations for each response. Provide note on plans that fire alarm and fire sprinkler will be on a separate permit. 2. Please provide detail for Fire Fighter Safety Building Marking System per Florida Administrative Code 69A-3.012 and Florida Statutes 633.027 3. Please provide engineering design for fire sprinkler systems and fire alarm systems as part of these submitted plans. A Florida licensed professional engineer is responsible to establish design concepts established through the Responsibility Rules adopted by the Florida Board of Professional Engineers. F.S. 633.102 (19). Layout of risers, cross mains, branch lines, sprinkler heads, sizing of pipe, hanger locations, and hydraulic calculations in accordance with the design concepts established by the engineer are provided by the licensed fire protection contractor under separate building permit for installation of fire sprinkler and fire alarm systems 4. Please establish a written fire safety plan for safeguards during construction per 8th edition (2023) FFPC 1, 16.4.1.1, 16.4.1.2.(1) through (8), and NFPA 241 (2013). and FBCB Chapter 33. The plan, at a minimum, shall include details for fire extinguishers per FBCB Section 3309, means of egress per FBCB Section 3310, standpipes per Section 3311, and water supply for fire protection per FBCB Section 3313. The plan shall also address, at a minimum, housekeeping, on-site security, pre-fire planning, access for firefighting, stairs, standpipes and fire protection during construction. The plan is subject to review. 5. Please provide plans for the security fence during construction per FFPC 8th edition (2023) 1, 16.4.2.5.4 and the AHJ [241:7.2.5.4] Please use the following information to obtain a properly keyed Knox Padlock… Please select FLAGLER COUNTY DEPT. of EMERGENCY MANAGEMENT, for jurisdiction or agency even though it is going in the city. This way it will get it keyed correctly. https://www.knoxbox.com/Products/Commercial-KnoxBoxes
FI1 HOLD 07/31/2025 08/13/2025
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM All comments below per the 8th edition Florida Fire Prevention Code and / or the 2023 Florida Building Code-Building Please provide a written response to each comment below in a response letter and provide clouded response changes on plan sheets and add page locations for each response. Provide note on plans that fire alarm and fire sprinkler will be on a separate permit. 2. Please provide detail for Fire Fighter Safety Building Marking System per Florida Administrative Code 69A-3.012 and Florida Statutes 633.027 3. Please provide engineering design for fire sprinkler systems and fire alarm systems as part of these submitted plans. A Florida licensed professional engineer is responsible to establish design concepts established through the Responsibility Rules adopted by the Florida Board of Professional Engineers. F.S. 633.102 (19). Layout of risers, cross mains, branch lines, sprinkler heads, sizing of pipe, hanger locations, and hydraulic calculations in accordance with the design concepts established by the engineer are provided by the licensed fire protection contractor under separate building permit for installation of fire sprinkler and fire alarm systems 4. Please establish a written fire safety plan for safeguards during construction per 8th edition (2023) FFPC 1, 16.4.1.1, 16.4.1.2.(1) through (8), and NFPA 241 (2013). and FBCB Chapter 33. The plan, at a minimum, shall include details for fire extinguishers per FBCB Section 3309, means of egress per FBCB Section 3310, standpipes per Section 3311, and water supply for fire protection per FBCB Section 3313. The plan shall also address, at a minimum, housekeeping, on-site security, pre-fire planning, access for firefighting, stairs, standpipes and fire protection during construction. The plan is subject to review. 5. Please provide plans for the security fence during construction per FFPC 8th edition (2023) 1, 16.4.2.5.4 and the AHJ [241:7.2.5.4] Please use the following information to obtain a properly keyed Knox Padlock… Please select FLAGLER COUNTY DEPT. of EMERGENCY MANAGEMENT, for jurisdiction or agency even though it is going in the city. This way it will get it keyed correctly. https://www.knoxbox.com/Products/Commercial-KnoxBoxes
ELEC COMPLETE 07/31/2025 08/13/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH HOLD 07/31/2025 08/13/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM ALL COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING, FLORIDA BUILDING CODE-MECHANICAL AND FLORIDA BUILDING CODE -ENERGY CONSERVATION. RESUBMITTED PLAN PAGES NEED TO BE CLOUDED AND MUST HAVE A RESPONSE LETTER FROM THE ENGINEER SIGNED AND SEALED. REPEAT COMMENT: 11. Provide details on a permanent ladder per 306.5. FBC Mechanical. (NOT ANSWERED) REPEAT COMMENT: 12. Provide details on roof guards per 304.11 FBC Mechanical (NOT ANSWERED) PARTIAL REPEAT COMMENT: 13. Provide details showing length of dryer vent not to excced 35 Feet. If exceeds 35 Feet, provide manufacturers specs on dryers to be installed. 504.9.4, 504.9.4.2 FBC Mechanical (MANUFACTURERS SPECS DO NOT SHOW THE MODEL NUMBER OF THE DRYER TO BE USED. PROVIDE MODEL OF DRYER.) REPEAT COMMENT: 14. If dryer vent over 35 Feet provide details on permanent tag per 504.9.5 FBC Mechanical (NO PLAN DETAIL SHOWING PERMANENT TAG WITH LOCATION AND WORDING FOR LONG VENT APPLICATION)
PLUM HOLD 07/31/2025 08/13/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-PLUMBING (FBCP), FLORIDA BUILDING CODE-ACCESSIBILITY (FBCA), FLORIDA STATUTES (F.S.), FLORIDA ADMINISTRATIVE CODE (F.A.C.) AND AUTHORITY HAVING JURISDICTION (A.H.J.). RESUBMITTED PLAN PAGES NEED TO BE CLOUDED AND MUST HAVE A RESPONSE LETTER FROM THE ENGINEER SIGNED AND SEALED. REPEAT COMMENT: 1. All plumbing plan pages need a verifiable digital signature F.S. 471-025 (NO NEW PLUMBING PLAN SHEETS UPLOADED)
BLD COMPLETE 07/31/2025 08/13/2025
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
DSD HOLD 07/31/2025 08/04/2025
Note: Held By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM 1. Prior to issuance of building permits, all life- safety facilities necessary to support access and safety of the site by first responders must be in place completed and functioning for their intended purpose. These life-safety facilities are in addition to water, wastewater and stormwater facilities (including DEP certification), fire-protection and, at a minimum, stabilized fire access roads. 2. Commercial Project Site Improvement Permit must be issued and inspections must pass before release of permits to go vertical.
UD1 COMPLETE 07/31/2025 08/14/2025
Note: Released By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM
ARCHR COMPLETE 05/20/2025 06/04/2025
Note: Released By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM
BLD HOLD 05/20/2025 07/09/2025
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM ALL COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING (FBCB), FLORIDA BUILDING CODE-ACCESSIBILITY (FBCA), FLORIDA BUILDING CODE-PLUMBING (FBCP), FLORIDA STATUTES (FS), FLORIDA ADMINISTRATIVE CODE (FAC) AND AUTHORITY HAVING JURISDICTION (AHJ). PLAN RE-SUBMITTAL SHALL BE ACCOMPANIED BY A RESPONSE LETTER SIGNED AND SEALED BY THE APPROPRIATE DESIGN PROFESSIONAL(S). ALL PLAN REVISIONS SHALL BE CLOUDED APPROPRIATELY. 1. This is a threshold building per Sections 202 (definition of threshold building), 110.8.1. Architect and engineer to prepare threshold inspection plan prior to issuance of building permit Section 110.8.1. It is suggested to use IBC Sections 1704 and 1705 as guidance, but is not required. Provide inspection schedules and procedures Section 110.8.1. Include reporting obligations to building official for enforcement matters should contractor not be in compliance with threshold inspection plan Section 110.8.3. 2. The special inspector(s) providing threshold inspections shall be named and the inspector(s) shall be a Florida licensed architect and / or professional engineer and certified (specific endorsement) for special inspections. F.S. Chapters 471 and 481. Provide qualifications. 3. Any shoring during construction shall be included in threshold inspection plan. Engineer who specializes in performing shoring inspections shall be named Section 110.8.2 4. Threshold inspections are not provided through general contractor. Provide agreement / contract signed by owner and special inspector indicating all fees and costs associated with threshold inspections are by fee owner of building. 5. Plan Sheet A413. Confirm by note, dimensions or graphic illustration elevator car can accommodate an ambulance stretcher oof the dimensions shown. FBCB Section 3002.4 6. Plan Sheet A413. Confirm by note, the elevator will be operational for building occupants in addition to fire department. FBCB Section 3002.4 7. Plan Sheet A413. Confirm by note and graphic example the location of the international symbol for emergency medical services (star of life). FBCB 3002.4 8. Plan Sheet A413. Confirm by note the elevator is not required to be an occupant evacuation elevator and confirms to Item 1 or 2. FBCB Section 3008.1.1 9. Provide list of deferred submittals. Engineered truss plans not provided, list them as a deferred submittal. Pre-manufactured guards, stairs and similar. FBCB Section 107.3.4.1 10. Provide City of Palm Coast Roofing Worksheet - FL# 18374-R4 not valid. 11. All structural plan sheets shall be digitally signed, sealed, and verifiable. FAC 65G15-23.004. Be sure digital seals include the required language in this FAC section. 12. Plan Sheet A010 under Fire Protection for (Mix 1). Under Florida Building Code you have Sprinklered NFPA 13R, under Florida Fire Prevention you have Sprinklered NFPA 13. Which one is correct? 13. Construction type VA requires fire resistible rated exterior walls both bearing and non-bearing regardless of location and fire separation distance. None of the plan sheets indicate fire resistive rated exterior walls. FBCB Section 602.1, Table 602.1 (see footnote e.), 705.5 and Table 705.5. Exterior walls whit a fire separation distance greater than 10 feet shall be rated for fire exposure from inside the inside. 14. Plan Sheet A060- Notes refer to FBC 7th Edition. Please update to current code cycle. 15. Plan Sheet A455 - Details 1 and 2 reference 5/A601a - sheet not attached. 16. Plan Sheet A227- Attic Ventilation Notes - Reference FCBC 7th Ed. 2020. Please update to current code cycle. 17. Plan Sheet A560 - References 1/A500 for additional information. Plan sheet not attached. 18. Provide site plan with distances between buildings for Fire separation distance FBC 705.6
DSD HOLD 05/20/2025 05/22/2025
Note: Held By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM Prior to issuance of permits, infrastructure to support the life and safety issues must be met. These are not limit to waste water certification, fire protection, stabilized roads. a. A staging plan. The staging plan must show the order these buildings will be CO’d. b. Show Ingress and egress. c. Please provide a note on the plans stating: The required fire hydrants and supply will be installed, tested, and in service for prior to combustible materials being delivered per FFPC 1, section 16.5.3 d. Show stabilized road. Stabilized access roads shall be maintained by the project developer and deficiencies observed by the Palm Coast Fire Department shall be promptly corrected to the satisfaction of the Palm Coat Fire Department. e. Temporary Cul-de-sac for fire trucks (as applicable). If a Cul-da-sac is needed add a note to your temporary cul-de-sac detail that the roadway must be able to support a 75,000-pound vehicle. f. Denote and map area for FDEP partial clearance for water main on-site plan. g. A sign is required to be located on building location stating the following: “NOTICE: DO NOT CONNECT WATER OR SEWER LINES”. This sign should be in English and Spanish. (See Exhibit B). Signs are required to be maintained and always in vertical position. If this site has a SWPPP on file all requirements listed in this plan must be met to include the stabalization of areas not to be built on with seeds. h. Issuance of permits shall also conform to requirements of other City departments and divisions. When submitting for a modification to the DO submit all pictures with the signs posted on each proposed building location, DEP clearance and all test preformed on the waste water system.
ELEC HOLD 05/20/2025 06/02/2025
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need note on plan for all equipment rooms. NEC 2020 110.26(C) (3) 2. Equipment rooms need to comply with NEC 2020 110.26 (E)(1) 3. Plans need to be digitally signed and sealed.
FI1 HOLD 05/20/2025 06/02/2025
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM All comments below per the 8th edition Florida Fire Prevention Code and / or the 2023 Florida Building Code-Building Please provide a written response to each comment below in a response letter and provide clouded response changes on plan sheets and add page locations for each response. Provide note on plans that fire alarm and fire sprinkler will be on a separate permit. 1. Need to update NFPA 101 and 1 code year 2. Please provide detail for Fire Fighter Safety Building Marking System per Florida Administrative Code 69A-3.012 and Florida Statutes 633.027 3. Please provide engineering design for fire sprinkler systems and fire alarm systems as part of these submitted plans. A Florida licensed professional engineer is responsible to establish design concepts established through the Responsibility Rules adopted by the Florida Board of Professional Engineers. F.S. 633.102 (19). Layout of risers, cross mains, branch lines, sprinkler heads, sizing of pipe, hanger locations, and hydraulic calculations in accordance with the design concepts established by the engineer are provided by the licensed fire protection contractor under separate building permit for installation of fire sprinkler and fire alarm systems 4. Please establish a written fire safety plan for safeguards during construction per 8th edition (2023) FFPC 1, 16.4.1.1, 16.4.1.2.(1) through (8), and NFPA 241 (2013). and FBCB Chapter 33. The plan, at a minimum, shall include details for fire extinguishers per FBCB Section 3309, means of egress per FBCB Section 3310, standpipes per Section 3311, and water supply for fire protection per FBCB Section 3313. The plan shall also address, at a minimum, housekeeping, on-site security, pre-fire planning, access for firefighting, stairs, standpipes and fire protection during construction. The plan is subject to review. 5. Please provide plans for the security fence during construction per FFPC 8th edition (2023) 1, 16.4.2.5.4 and the AHJ [241:7.2.5.4] Please use the following information to obtain a properly keyed Knox Padlock… Please select FLAGLER COUNTY DEPT. of EMERGENCY MANAGEMENT, for jurisdiction or agency even though it is going in the city. This way it will get it keyed correctly. https://www.knoxbox.com/Products/Commercial-KnoxBoxes 6. 3311.1 Where required. In buildings required to have standpipes by Section 905.3.1, no fewer than one standpipe shall be provided for use during construction. Such standpipes shall be installed prior to construction exceeding 40 feet (12 192 mm) in height above the lowest level of fire department vehicle access. Such standpipes shall be provided with fire department hose connections at accessible locations adjacent to usable stairways. Such standpipes shall be extended as construction progresses to within one floor of the highest point of construction having secured decking or flooring. Provide a plan showing how the standpipe will be getting water and show where they will be located at on each floor 7. Please include the following code versions the plan sheets anywhere they appear on the plans FBC 8th edition (2023) FFPC 8th edition (2023) Florida Fire Prevention Code with the Florida specific NFPA 1 and 101 NFPA 10, (2018) edition, Standard for Portable Fire Extinguishers NFPA 13R, (2019) edition, Standard for the Installation of Sprinkler Systems in Low-Rise Residential Occupancies NFPA 72, (2019) edition, National Fire Alarm and Signaling Code NFPA 70, (2020) edition, National Electrical Code
GAS CANCEL 05/20/2025 05/30/2025
MECH HOLD 05/20/2025 06/09/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM ALL COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING, FLORIDA BUILDING CODE-MECHANICAL AND FLORIDA BUILDING CODE -ENERGY CONSERVATION. RESUBMITTED PLAN PAGES NEED TO BE CLOUDED AND MUST HAVE A RESPONSE LETTER FROM THE ENGINEER SIGNED AND SEALED. 1. Requirements need to be 100% addressed in comcheck. 107.2.1 FBC 2. All Mechanical plan pages need to have a verifiable digital signature. 471.025 3. Provide the Effective dispersal volume charge per 7.2 Ashrae 15. Show calculation for all systems including common areas. If Refrigerant charge exceeds the EDVC, then show compliance with #4, 5, 6, and 7 below. 4. Provide means of refrigerant detector per 1105.3 FBC Mechanical 5. Provide means of ventilation per 1105.6 and discharge location 1105.6.1 and makeup air 1105.6.2 FBC Mechanical or Ashrae 15 6. Provide details on remote controls of mechanical equipment and refrigerant system shutoff and ventilation system in machinery rooms per 1106.5,1106.5.1,1106.5.2 FBC Mechanical 7. Provide details that show machinery room complies with class 1 division 2. 1106.4 FBC Mechanical or Ashrae 15 8. Provide Heatload Calculation per C403.2.1 FBC Energy Conservation 9. Provide manufacturers specs on fire dampers per 607.2 FBC Mechanical 10. Provide Ventilation calculation per Table 403.3.1.1 FBC Mechanical 11. Provide details on a permanent ladder per 306.5. FBC Mechanical 12. Provide details on roof guards per 304.11 FBC Mechanical 13. Provide details showing length of dryer vent not to excced 35 Feet. If exceeds 35 Feet, provide manufacturers specs on dryers to be installed. 504.9.4, 504.9.4.2 FBC Mechanical 14. If dryer vent over 35 Feet provide details on permanent tag per 504.9.5 FBC Mechanical
UD1 HOLD 05/20/2025 05/29/2025
Note: Held By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM Please refer to Utility (water & sewer) comments made by Development Services Reviewer
PLUM HOLD 05/20/2025 06/10/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-PLUMBING (FBCP), FLORIDA BUILDING CODE-ACCESSIBILITY (FBCA), FLORIDA STATUTES (F.S.), FLORIDA ADMINISTRATIVE CODE (F.A.C.) AND AUTHORITY HAVING JURISDICTION (A.H.J.). RESUBMITTED PLAN PAGES NEED TO BE CLOUDED AND MUST HAVE A RESPONSE LETTER FROM THE ENGINEER SIGNED AND SEALED. 1. All plumbing plan pages need a verifiable digital signature F.S. 471-025

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 10% (¤1,383.44) 02/10/2026
ADMINISTRATIVE - COMMERCIAL PP ¤3,000.00 02/10/2026
ADMINISTRATIVE - COMMERCIAL ¤75.00 02/10/2026
INSPECTION - FIRE COMMERCIAL ¤2,084.75 02/10/2026
PLAN REVIEW - COMMERCIAL ¤11,674.60 02/10/2026
FC IMPACT FEE EMS ¤2,304.00 02/10/2026
FC IMPACT FEE LAW ENFORCEMENT ¤7,992.00 02/10/2026
FC IMPACT FEE LIBRARY ¤10,008.00 02/10/2026
SURCHARGE FS 533.721 ¤154.51 02/10/2026
SURCHARGE - FS 468.631 ¤231.77 02/10/2026
SITE PLAN 30 ¤30.00 02/10/2026
IMPACT FEE PARKS ¤131,616.72
IMPACT FEE TRANSPORTATION ¤145,296.00
IMPACT FEE FIRE ¤31,284.72
Fees Total Due: ¤308,197.44 Total Paid: ¤36,171.19