I want to search for...
Permit #2025050883
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7023-00080-0110 |
| Block: 00080 |
| Subdivision: 7023 - |
| Job Phone: 386-931-0184 |
| Location Address: 5 WHITCOCK LN |
| Type: PO - POOL |
| Issue Date: 06/13/2025 |
| NOC: RECORDED |
| Applicant name: ROY C WALDHAUER |
| Owner: MISKO JAMES M & SUSAN L H&W |
|
Address 5 WHITCOCK LANE PALM COAST, FL 32164 |
| Lot: 0110 |
| Contracted Stated Job Value: ¤61,000.00 |
| Job Description: Enclosed Swimming Pool |
| Type: CN |
Contractor
BY THE SHORE INC
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
1600 N STATE STREET BUNNELL, FL 32110 |
#103 BUNNELL, FL 32110 |
CPC1457705 (Exp: 08/31/2026) | 386-446-5524 | 386-446-5107 |
Sub Contractors
ROY CHARLES WALDHAUER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1600 N STATE STREET # 102 , 0 |
CRC1327300 (Exp: 08/31/2026) | 386-263-8272 | 386-263-8289 |
CHRISTOPHER I HALL
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 2413 Bunnell, FL 32110 |
EC13002161 (Exp: 08/31/2028) | (386) 437-2966 | 386-437-5042 |
ROY CHARLES WALDHAUER II
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1600 N STATE STREET # 102 BUNNELL, FL 32110 |
CPC057029 (Exp: 08/31/2026) | 386-263-8272 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 03/05/2026 | FINAL APPROVED | HCAMACHO |
| U -UTILITY RESIDENTIAL FINAL | 02/17/2026 | FINAL APPROVED | BHAINES |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 02/12/2026 | APPROVED | TPOLACEK |
| Note: 02-12-26 TPOLACEK*** AFTER WALKING SITE WITH HOMEOWNER DRAINAGE WILL NOT ADVERSLY EFFECT ADJOIING PROPERTIES. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 12/15/2025 - PREVIOUS INSPECTION NOTES 12-15-25 TPOLACEK*** FINAL SURVEY DOES NOT MEET COPC MINIMUM STANDARDS NOR DOES IT MATCH THE APPROVED SITE PLAN. SITE PLAN PROPESED ALL DRAINAGE WOULD MOVE TO FRONT SWALE AS REQUIRED. FINAL SURVEY SHOWS ALL DRAINAGE WILL IMPACT ADJACENT LOT TO THE REAR AND FLOOD SUBJECT LOTS PROPERTY. BUILDER IS REQUIRED TO CONSTRUCT THE DRAINAGE TO MEET COPC STANDARDS AND MATCH THE APPROVED SUBMITTED SITE PLAN. INSPECTOR WAS ONSITE WITH HOME OWNER TO SEE GRADE AND DISCUSS ISSUES. BUILDER MUST REGRADE TO SITE PLAN AND SUBMIT A NEW FINAL SURVEY. 15 Negatively impact Sec 300.01 (A)(1)(C)(6) Sec 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. (B) Finished Floor Elevations (FFE): Draining onto adjacent properties will not be allowed Section 300.01 C(6) V-16 6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement.Section 300.01 C(6) V-16 Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(6) V-17 6) The top of slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. Section 300.01 D(6) V-17 Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 feet. Section 300.01 D(4) V-17 12/5/2025 - PREVIOUS INSPECTION NOTES ** 12/05/25 BUILDER REQUIRED TO PROVIDE THE FFE OF POOL DECK AND ALL IMPROVED ADJACENT PROPERTIES (REAR) ** Finished Floor Elevations (FFE): Section 300.01 B(2) V-15 2) Finished Floor Elevation (FFE) of the living area of all improved structures on adjacent ** 10 FT OFF-SET SHOTS REQUIRED ON LEFT SIDE 3) The elevations on all adjacent properties at a minimum of 20-foot intervals on a 10-foot offset outside the property lines. Section 300.01 B(3) V-15 | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 02/12/2026 | APPROVED | TPOLACEK |
| Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - FINAL INSPECTION | 02/12/2026 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/15/2025 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 12-15-25 TPOLACEK*** FINAL SURVEY DOES NOT MEET COPC MINIMUM STANDARDS NOR DOES IT MATCH THE APPROVED SITE PLAN. SITE PLAN PROPESED ALL DRAINAGE WOULD MOVE TO FRONT SWALE AS REQUIRED. FINAL SURVEY SHOWS ALL DRAINAGE WILL IMPACT ADJACENT LOT TO THE REAR AND FLOOD SUBJECT LOTS PROPERTY. BUILDER IS REQUIRED TO CONSTRUCT THE DRAINAGE TO MEET COPC STANDARDS AND MATCH THE APPROVED SUBMITTED SITE PLAN. INSPECTOR WAS ONSITE WITH HOME OWNER TO SEE GRADE AND DISCUSS ISSUES. BUILDER MUST REGRADE TO SITE PLAN AND SUBMIT A NEW FINAL SURVEY. 15 Negatively impact Sec 300.01 (A)(1)(C)(6) Sec 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. (B) Finished Floor Elevations (FFE): Draining onto adjacent properties will not be allowed Section 300.01 C(6) V-16 6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement.Section 300.01 C(6) V-16 Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(6) V-17 6) The top of slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. Section 300.01 D(6) V-17 Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 feet. Section 300.01 D(4) V-17 12/5/2025 - PREVIOUS INSPECTION NOTES ** 12/05/25 BUILDER REQUIRED TO PROVIDE THE FFE OF POOL DECK AND ALL IMPROVED ADJACENT PROPERTIES (REAR) ** Finished Floor Elevations (FFE): Section 300.01 B(2) V-15 2) Finished Floor Elevation (FFE) of the living area of all improved structures on adjacent ** 10 FT OFF-SET SHOTS REQUIRED ON LEFT SIDE 3) The elevations on all adjacent properties at a minimum of 20-foot intervals on a 10-foot offset outside the property lines. Section 300.01 B(3) V-15 | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/05/2025 | Disapproved - NO FEE | EMADISON |
| Note: ** 12/05/25 BUILDER REQUIRED TO PROVIDE THE FFE OF POOL DECK AND ALL IMPROVED ADJACENT PROPERTIES (REAR) ** Finished Floor Elevations (FFE): Section 300.01 B(2) V-15 2) Finished Floor Elevation (FFE) of the living area of all improved structures on adjacent ** 10 FT OFF-SET SHOTS REQUIRED ON LEFT SIDE 3) The elevations on all adjacent properties at a minimum of 20-foot intervals on a 10-foot offset outside the property lines. Section 300.01 B(3) V-15 | |||
| ELECTRIC AND ALARM | 09/26/2025 | APPROVED | MCONTRYMAN |
| POOL DECK | 08/04/2025 | APPROVED | MKRASKI |
| POOL DECK | 08/01/2025 | Disapproved -FEE REQUIRED | MCONTRYMAN |
| Note: 8/1/25 Previous note not rectified 1. Footing need to be cleaned out from wash outs to match plans FBC R404.1.3.3.7.4 --There needs to be 3" clearance from soil for rebar, as well as matching proper depth per plans 7/31/2025 - PREVIOUS INSPECTION NOTES 1. Footing need to be cleaned out from wash outs to match plans FBC R404.1.3.3.7.4 | |||
| POOL DECK | 07/31/2025 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Footing need to be cleaned out from wash outs to match plans FBC R404.1.3.3.7.4 | |||
| STEEL AND GROUND | 06/25/2025 | APPROVED | MCONTRYMAN |
Review History
| Department | Status | Date In | Date Out |
| BFLOOD | COMPLETE | 05/20/2025 | 05/23/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 05/20/2025 | 05/23/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 05/20/2025 | 05/23/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 05/20/2025 | 05/23/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 05/20/2025 | 05/21/2025 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/20/2025 | 05/20/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/04/2026 |
| RSI REINSPECTION 1 | ¤35.00 | 03/04/2026 |
| SURCHARGE FS 533.721 | ¤2.30 | 06/13/2025 |
| SURCHARGE - FS 468.631 | ¤3.44 | 06/13/2025 |
| SW ENG INSPECTION 40 | ¤40.00 | 06/13/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 06/13/2025 |
| SITE PLAN 30 | ¤30.00 | 06/13/2025 |
| ADJUSTMENT 10% | (¤25.50) | 06/13/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 06/13/2025 |
| INSPECTION- POOL | ¤160.00 | 06/13/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤65.00 | 06/13/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤400.24 |