I want to search for...
Permit #2025050902
Permit Details
Status: FINAL
| Parcel Id: 22-10-30-3755-00000-00B0 |
| Subdivision: 2357 - LAKEVIEW ESTATES TRACT 1 |
| Job Phone: 904-984-9939 |
| Location Address: 270 LAKEVIEW BLVD |
| Type: CE - COMMERCIAL ELECTRIC |
| Issue Date: 05/21/2025 |
| NOC: Unknown |
| Applicant name: GLENN LEE BAKER |
| Owner: FORESTAR (USA) REAL ESTATE GROUP INC |
|
Address 2221 E LAMAR BLVD ARLINGTON, TX 76006 |
|
Address SUITE 790 ARLINGTON, TX 76006 |
| Contracted Stated Job Value: ¤1,000.00 |
| Job Description: 200a Irrigation Service |
| Type: CN |
Contractor
ADKINS ELECTRIC INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
10477 NEW KINGS RD , |
EC13013004 (Exp: 08/31/2026) | 904-765-1622 |
Inspection History
| Type | Request Date | Result | Inspector |
| ELECTRIC FINAL | 07/29/2025 | FINAL APPROVED | MKRASKI |
| ELECTRIC FINAL | 07/14/2025 | PARTIALLY APPROVED | JMUNSON |
| Note: Emailed FPL to release meter. Call Back in once power is on. 6/30/2025 - PREVIOUS INSPECTION NOTES 1. Revision shows 50a with #6 wiring installed for irragation pump, a 40a is installed FBC (A)107.4 2. Can not locate 2nd ground rod NEC 250.53(A)(2) 3. 2'' service conduit is not a min of 18'' below grade NEC 300.5 (D)(3) 4. Conduit feeding into irragation equipment must be secured NEC 342.30 5. Can not verify 2'' riser is sch80 PVC NEC 300.5(D)(1)/(4) 6. Siemans breaker is installed for irragation equipment, Siemans is not a UL listed breaker for Eaton panels, per manufacturer FBC (A)107.4 | |||
| ELECTRIC FINAL | 06/30/2025 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Revision shows 50a with #6 wiring installed for irragation pump, a 40a is installed FBC (A)107.4 2. Can not locate 2nd ground rod NEC 250.53(A)(2) 3. 2'' service conduit is not a min of 18'' below grade NEC 300.5 (D)(3) 4. Conduit feeding into irragation equipment must be secured NEC 342.30 5. Can not verify 2'' riser is sch80 PVC NEC 300.5(D)(1)/(4) 6. Siemans breaker is installed for irragation equipment, Siemans is not a UL listed breaker for Eaton panels, per manufacturer FBC (A)107.4 | |||
| ELECTRIC FINAL | 05/30/2025 | Disapproved - NO FEE | MKRASKI |
| Note: Wiring/conduit for irragation pump not installed and does not show on riser diagram, a revision is required showinf conduit and wiring size. |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 06/02/2025 | 06/04/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 05/20/2025 | 05/21/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 10% | (¤16.75) | 05/21/2025 |
| ADMINISTRATIVE - COMMERCIAL | ¤75.00 | 05/21/2025 |
| INSPECTION- ELECTRICAL | ¤60.00 | 05/21/2025 |
| PLAN REVIEW - MISC 32.50 | ¤32.50 | 05/21/2025 |
| SURCHARGE FS 533.721 | ¤2.00 | 05/21/2025 |
| SURCHARGE - FS 468.631 | ¤2.26 | 05/21/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤155.01 |