Permit #2025050902

Permit Details

Status: FINAL

Parcel Id: 22-10-30-3755-00000-00B0
Subdivision: 2357 - LAKEVIEW ESTATES TRACT 1
Job Phone: 904-984-9939
Location Address: 270 LAKEVIEW BLVD
Type: CE - COMMERCIAL ELECTRIC
Issue Date: 05/21/2025
NOC: Unknown
Applicant name: GLENN LEE BAKER
Owner: FORESTAR (USA) REAL ESTATE GROUP INC

Address

2221 E LAMAR BLVD

ARLINGTON, TX 76006

Address

SUITE 790

ARLINGTON, TX 76006

Contracted Stated Job Value: ¤1,000.00
Job Description: 200a Irrigation Service
Type: CN

Contractor

ADKINS ELECTRIC INC
Status Location Address State License Number Phone
ACTIVE

10477 NEW KINGS RD

,

EC13013004 (Exp: 08/31/2026) 904-765-1622

Inspection History

Type Request Date Result Inspector
ELECTRIC FINAL 07/29/2025 FINAL APPROVED MKRASKI
ELECTRIC FINAL 07/14/2025 PARTIALLY APPROVED JMUNSON
Note: Emailed FPL to release meter. Call Back in once power is on. 6/30/2025 - PREVIOUS INSPECTION NOTES 1. Revision shows 50a with #6 wiring installed for irragation pump, a 40a is installed FBC (A)107.4 2. Can not locate 2nd ground rod NEC 250.53(A)(2) 3. 2'' service conduit is not a min of 18'' below grade NEC 300.5 (D)(3) 4. Conduit feeding into irragation equipment must be secured NEC 342.30 5. Can not verify 2'' riser is sch80 PVC NEC 300.5(D)(1)/(4) 6. Siemans breaker is installed for irragation equipment, Siemans is not a UL listed breaker for Eaton panels, per manufacturer FBC (A)107.4
ELECTRIC FINAL 06/30/2025 Disapproved - NO FEE MKRASKI
Note: 1. Revision shows 50a with #6 wiring installed for irragation pump, a 40a is installed FBC (A)107.4 2. Can not locate 2nd ground rod NEC 250.53(A)(2) 3. 2'' service conduit is not a min of 18'' below grade NEC 300.5 (D)(3) 4. Conduit feeding into irragation equipment must be secured NEC 342.30 5. Can not verify 2'' riser is sch80 PVC NEC 300.5(D)(1)/(4) 6. Siemans breaker is installed for irragation equipment, Siemans is not a UL listed breaker for Eaton panels, per manufacturer FBC (A)107.4
ELECTRIC FINAL 05/30/2025 Disapproved - NO FEE MKRASKI
Note: Wiring/conduit for irragation pump not installed and does not show on riser diagram, a revision is required showinf conduit and wiring size.

Review History

Department Status Date In Date Out
ELEC COMPLETE 06/02/2025 06/04/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 05/20/2025 05/21/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 10% (¤16.75) 05/21/2025
ADMINISTRATIVE - COMMERCIAL ¤75.00 05/21/2025
INSPECTION- ELECTRICAL ¤60.00 05/21/2025
PLAN REVIEW - MISC 32.50 ¤32.50 05/21/2025
SURCHARGE FS 533.721 ¤2.00 05/21/2025
SURCHARGE - FS 468.631 ¤2.26 05/21/2025
Fees Total Due: ¤0.00 Total Paid: ¤155.01