I want to search for...

Permit #2025051091

Permit Details

Status: COED

Parcel Id: 07-11-31-7019-00230-0050
CONDITIONED SPACE: 1800 sqft
GARAGE: 410 sqft
OPENED PORCH (WITH ROOF) : 36 sqft
Total Square Footage: 2246 sqft
Block: 00230
Subdivision: -
Job Phone: 689-250-2429
Location Address: 4 WATEING PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/19/2025
NOC: RECORDED
Applicant name: RYAN M COURECH
Owner: A AND R-MERIDIAN REAL ESTATE DEVELOPMENT LLC

Address

688 N ORLANDO AVENUE

MAITLAND, FL 32751

Address

SUITE 207

MAITLAND, FL 32751

Lot: 0050
Contracted Stated Job Value: ¤208,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN
Original Permit #: 2024010999

Contractor

MCH CONSTRUCTION LLC
Status Location Address State License Number Phone
INACTIVE

668 N ORLANDO AVE, STE 207

MAITLAND, FL 32751

CBC1262898 (Exp: 08/31/2026) 407-602-8257

Sub Contractors

DUSTIN ARCHER
Status Location Address State License Number Phone
ACTIVE

2785 WRIGHTS ROAD SUITE 1133

OVIEDO, FL 32765

CMC1251099 (Exp: 08/31/2026) 407-391-1145
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633
CHAD DAVID GRESSANI
Status Location Address State License Number Phone Fax
ACTIVE

2640 BROOKSHIRE CIRCLE

MELBOURNE, FL 32904

CCC1327235 (Exp: 08/31/2026) 321-288-6415 321-729-8997

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 12/02/2025 Approval - Private Provider PPROVIDER
ROW - FINAL APRON (AFTER POUR) 12/02/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW FIELD SURVEY /GRADING CERTIFICATION 12/02/2025 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - STORMWATER FINAL 12/02/2025 APPROVED - AS NOTED TPOLACEK
Note: 12-2-25 TPOLACEK*** PREVIOUS NOTE STATED TO PLEASE MAKE SURE CULVERT AT #6 WAS CLEANED OUT. INSPECTOR HAS UPLOADED PIC FROM TODAYS INSPECTION SHOWING AT THE TIME OF INSPECTION PIPE IS CLEAR. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 9/16/25 BEFORE THIS INSPECTION IS APPROVED PLEASE MAKE SURE ALL DIRT IS CLEANED OUT OF THE CULVERT TO THE LEFT ADDRESS 6 WATEING PLACE.
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/26/2025 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 11/17/2025=Ensure water does not affect the neighbor on the left.Per Gbertola, Check the notes on the Row Final
ROW- PRE-APRON (PRE-POUR) 10/29/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR.
GRAVITY SEWER TEST 10/02/2025 Approval - Private Provider PPROVIDER
Note: Inspector Notes from Inspection 9450 THIS WAS A VIRTUAL INSPECTION
U-CROSS CONNECTION 09/30/2025 APPROVED - AS NOTED LFITZGERALD
Note: no irr-no cc
U - SEWER TIE IN 09/29/2025 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
ELECTRIC - EARLY POWER 09/25/2025 Approval - Private Provider PPROVIDER
INSULATION 09/24/2025 Approval - Private Provider PPROVIDER
ROW - DRAINAGE 09/19/2025 APPROVED TPOLACEK
Note: 09-19-25 TPOLACEK*** BUILDER NEEDS TO CHECK TEMP PIPE AND MAKE SURE IT FLOWS. =+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/16/2025 - PREVIOUS INSPECTION NOTES 1) NEED TO INSTALL SILT FENCE ON THE LEFT SIDE TO THE EDGE OF ROAD DUE TO SEDIMENT FLOWING INTO THE ADJACENT LOT TO THE LEFT. 2) NEED TO INSTALL SILT FENCE ACROSSED THE FRONT SO SEDIMENT DONT WASH INTO THE SWALE. YOU WILL HAVE 3DAY TO FIX ALL ISSUES ----------------------------------------------------------------------------------- 7/31/2025 - PREVIOUS INSPECTION NOTES 07/31/25 TPOLACEK*** PORTA POTTY HAS BEEN MOVED HOWVER THERE IS A LARGE OVER POURF SPILL IN THE ROW THAT IS AN ILLICIT DISCHARGE AND MUST BE REMOVED ASAP. BUILDER HAS 24 HOURS TO REMOVE ILLICIT DISCHARGE BEFORE PRIORITY 1 STATUS. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 7/24/2025 - PREVIOUS INSPECTION NOTES ** 07/24/25 BUILDER IS REQUIRED TO REMOVE THE PORT-A-JOHN OUT OF THE ROADSIDE SWALE (ROW) AND PUY ONTO JOBSITE. ** YOU WILL HAVE 7 DAYS TO COMPLY IF AT THE TIME OF THE NEXT INSPECTION THE PORT-A-JOHN HAS NOT BEEN MOVED AN INSPECTION HOLD PRIORITY 1 STATUS WILL BE PLACED ON THIS PERMIT ** SEE ATTACHED PHOTO ** FOLLOW UP INSPECTION ON 07/31/25
ROW - DRAINAGE 09/16/2025 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) NEED TO INSTALL SILT FENCE ON THE LEFT SIDE TO THE EDGE OF ROAD DUE TO SEDIMENT FLOWING INTO THE ADJACENT LOT TO THE LEFT. 2) NEED TO INSTALL SILT FENCE ACROSSED THE FRONT SO SEDIMENT DONT WASH INTO THE SWALE. YOU WILL HAVE 3DAY TO FIX ALL ISSUES ----------------------------------------------------------------------------------- 7/31/2025 - PREVIOUS INSPECTION NOTES 07/31/25 TPOLACEK*** PORTA POTTY HAS BEEN MOVED HOWVER THERE IS A LARGE OVER POURF SPILL IN THE ROW THAT IS AN ILLICIT DISCHARGE AND MUST BE REMOVED ASAP. BUILDER HAS 24 HOURS TO REMOVE ILLICIT DISCHARGE BEFORE PRIORITY 1 STATUS. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 7/24/2025 - PREVIOUS INSPECTION NOTES ** 07/24/25 BUILDER IS REQUIRED TO REMOVE THE PORT-A-JOHN OUT OF THE ROADSIDE SWALE (ROW) AND PUY ONTO JOBSITE. ** YOU WILL HAVE 7 DAYS TO COMPLY IF AT THE TIME OF THE NEXT INSPECTION THE PORT-A-JOHN HAS NOT BEEN MOVED AN INSPECTION HOLD PRIORITY 1 STATUS WILL BE PLACED ON THIS PERMIT ** SEE ATTACHED PHOTO ** FOLLOW UP INSPECTION ON 07/31/25
LATH/BRICK/ WATER BARRIER 09/12/2025 Approval - Private Provider PPROVIDER
ALL ROUGH 09/12/2025 Approval - Private Provider PPROVIDER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/02/2025 Approval - Private Provider PPROVIDER
ROOF VALLEY & METAL 08/27/2025 Approval - Private Provider PPROVIDER
FORMBOARD SURVEY (OFFICE USE ONLY) 08/26/2025 APPROVED RRICKS
TIE BEAM / LINTEL 08/18/2025 Approval - Private Provider PPROVIDER
ROW - DRAINAGE 07/31/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 07/31/25 TPOLACEK*** PORTA POTTY HAS BEEN MOVED HOWVER THERE IS A LARGE OVER POURF SPILL IN THE ROW THAT IS AN ILLICIT DISCHARGE AND MUST BE REMOVED ASAP. BUILDER HAS 24 HOURS TO REMOVE ILLICIT DISCHARGE BEFORE PRIORITY 1 STATUS. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 7/24/2025 - PREVIOUS INSPECTION NOTES ** 07/24/25 BUILDER IS REQUIRED TO REMOVE THE PORT-A-JOHN OUT OF THE ROADSIDE SWALE (ROW) AND PUY ONTO JOBSITE. ** YOU WILL HAVE 7 DAYS TO COMPLY IF AT THE TIME OF THE NEXT INSPECTION THE PORT-A-JOHN HAS NOT BEEN MOVED AN INSPECTION HOLD PRIORITY 1 STATUS WILL BE PLACED ON THIS PERMIT ** SEE ATTACHED PHOTO ** FOLLOW UP INSPECTION ON 07/31/25
ROW - DRAINAGE 07/24/2025 Disapproved -FEE REQUIRED EMADISON
Note: ** 07/24/25 BUILDER IS REQUIRED TO REMOVE THE PORT-A-JOHN OUT OF THE ROADSIDE SWALE (ROW) AND PUY ONTO JOBSITE. ** YOU WILL HAVE 7 DAYS TO COMPLY IF AT THE TIME OF THE NEXT INSPECTION THE PORT-A-JOHN HAS NOT BEEN MOVED AN INSPECTION HOLD PRIORITY 1 STATUS WILL BE PLACED ON THIS PERMIT ** SEE ATTACHED PHOTO ** FOLLOW UP INSPECTION ON 07/31/25
MONOLITHIC SLAB 07/24/2025 Approval - Private Provider PPROVIDER
PLUMBING 1ST ROUGH UNDERGROUND 07/22/2025 Approval - Private Provider PPROVIDER
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 07/15/2025 APPROVED CPISCITELLI
ROW- PROJECT STATUS 07/10/2025 Status Check TPOLACEK
Note: 07/10/25 TPOLACEK*** AT THIS TIME SILT FENCE IT UP, TEMPORARY PIPE IS IN PLACE & SWALE IS OPEN. BUILDER DOES NEED TO MOVE PORTA POTTY FROM ROW AND ENSURE SITE CONDITIONS REMAIN. =++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Make sure the have the swale open and silt fence around the construction site. Per Gbertola
WATER METER INSTALLATION REQUEST 07/02/2025 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
SW1 COMPLETE 08/26/2025 08/26/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 08/26/2025 08/26/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
SW1 HOLD 07/23/2025 07/23/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Dimension 13.3' doesn't match the approved site plan of 15.3' at the front of the home. Please submit a revised formboard survey or submit a revised site plan for approval if the dimensions are changing.
ZON COMPLETE 07/23/2025 07/23/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BADMIN COMPLETE 07/14/2025 07/15/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 07/07/2025 07/10/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 06/13/2025 06/17/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 06/13/2025 06/17/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/13/2025 06/16/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ZON COMPLETE 06/13/2025 06/16/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SWALE COMPLETE 05/28/2025 06/18/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
BADMIN COMPLETE 05/27/2025 06/02/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 05/27/2025 05/29/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ENGIN1 COMPLETE 05/27/2025 05/28/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
LOCATE COMPLETE 05/27/2025 05/28/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
SW1 HOLD 05/27/2025 05/29/2025
Note: Held By: RODNEY RICKS - (386)986-2001 - RRICKS@PALMCOASTGOV.COM When proposing common or v swales there shall be a minimum of 0.2' fall from the top of the swale to the toe of slope to ensure the adajcent lots are not impacted. Base on the infomation provided this lot is negatively impacting lot 4. When common swales or v swale cannot be achieved a berm is allowed. Berms shall have minimum od 0.3' fall from the top of the swale to the toe of the swale per COPC Technical Manual. Please feel free to email or call if there are any questions or concerns.
ZON COMPLETE 05/27/2025 05/27/2025
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
MECH HOLD 05/27/2025 05/29/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy calcs do not match the heatload. Master file need to be approved with changes

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
SW ENG - INSPECTION 20 ¤20.00 12/02/2025
SW ENG - INSPECTION 20 ¤20.00 12/02/2025
SW ENG - INSPECTION 20 ¤20.00 12/02/2025
SW ENG - INSPECTION 20 ¤20.00 12/02/2025
SW ENG INSPECTION 80 ¤80.00 06/19/2025
SW ENG PRE APRON ¤30.00 06/19/2025
SW ENG - REVIEW 20 ¤20.00 06/19/2025
SW ENG RES REVIEW 200 ¤200.00 06/19/2025
WATER METER W/ TAP ¤2,326.93 06/19/2025
SEWER CREDIT (¤1,466.00) 06/19/2025
SEWER CAPITAL FACILITY ¤4,415.00 06/19/2025
WATER CAPITAL FACILITY FEE ¤3,790.49 06/19/2025
WATER MAIN EXTENSION IMPACT ¤917.27 06/19/2025
SITE PLAN 30 ¤30.00 06/19/2025
WATER- TURN ON ¤50.00 06/19/2025
ADJUSTMENT 10% (¤11.32) 06/19/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 06/19/2025
ADMINISTRATIVE - RESID PP ¤225.00 06/19/2025
PLAN REVIEW - APPROVED MASTER ¤83.20 06/19/2025
FC IMPACT FEE EMS ¤62.00 06/19/2025
IMPACT FEE FIRE ¤434.51 06/19/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 06/19/2025
FC IMPACT FEE LIBRARY ¤268.00 06/19/2025
IMPACT FEE PARKS ¤1,828.01 06/19/2025
IMPACT FEE SCHOOL ¤5,450.00 06/19/2025
IMPACT FEE TRANSPORTATION ¤1,916.00 06/19/2025
WASTEWATER MAIN EXTENSION IMPA ¤2,385.00 06/19/2025
SURCHARGE FS 533.721 ¤3.27 06/19/2025
SURCHARGE - FS 468.631 ¤4.90 06/19/2025
SW ENG - FOUNDATION SURVEY ¤20.00 06/19/2025
Fees Total Due: ¤0.00 Total Paid: ¤23,390.26