Permit #2025060084

Permit Details

Status: COED

Parcel Id: 07-11-31-7024-00530-0260
Block: 00530
Subdivision: 7024 -
Job Phone: 407-619-9214
Location Address: 24 PROSPECT LN
Type: SLRE - SOLAR ELECTRIC - PHOTOVOLTAIC
Issue Date: 06/05/2025
NOC: RECORDED
Applicant name: PAUL JOYCE
Owner: PEREZ MARGARITA M LIFE ESTATE

Address

24 PROSPECT LANE

PALM COAST, FL 32164

Lot: 0260
Contracted Stated Job Value: ¤38,724.00
Job Description: solar system roof mounted
Type: CN

Contractor

SUNRUN INSTALLATION SERVICES INC
Status Location Address State License Number Phone
ACTIVE

1000 GILLS DR STE 200

ORLANDO, FL 32824

EC13007964 (Exp: 08/31/2026) 855-478-6786

Inspection History

Type Request Date Result Inspector
SOLAR ELECTRIC FINAL 09/11/2025 FINAL APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 9/11/2025 10:18:37 AM *** 8/26/2025 - PREVIOUS INSPECTION NOTES please fix item from previous inspection ,not lock requiered , need barrier on the inside of the box top on feed wires coming in 1). Exterior disconnect requires service entry barriers over feed side conductors. NEC 230.62 (B) / 110.27(A)(1) 8/20/2025 - PREVIOUS INSPECTION NOTES 8/20/25: NO CHANGE FROM PREVIOUS INSPECTION. PLEASE DO NOT SCHEDULE THE RE-INSPECTION UNTIL A COMPANY REPRESENTATIVE VISUALLY VERIFIES THAT THE DEFICIENCY IS RESOLVED TO AVOID WASTING CITY RESOURCES AND TIME. 8/11/2025 - PREVIOUS INSPECTION NOTES 8/11/25: Previously listed deficiency from 1st inspection on 6/20/25 remains unresolved. 1). Exterior disconnect requires service entry barriers over feed side conductors. NEC 230.62 (B) / 110.27(A)(1) and (2) ----------- (NOTE: Main disconnect inside garage is not within line of sight.) (Accidental contact prevention >NEC 230.62 (B) / 110.27(A)(1) and (2)) 8/8/2025 - PREVIOUS INSPECTION NOTES 8/8/25: This inspection will need to be re-scheduled. Could not perform inspection today due to unforseen circumstances. Contact inspector Robert Sims directly with any questions. 6/20/2025 - PREVIOUS INSPECTION NOTES 6/20/25: 1). Exterior disconnect requires service entry barriers over feed side conductors. Main disconnect inside garage is not within line of sight. NEC 240.40/ 690.13(A)
SOLAR ELECTRIC FINAL 08/26/2025 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: please fix item from previous inspection ,not lock requiered , need barrier on the inside of the box top on feed wires coming in 1). Exterior disconnect requires service entry barriers over feed side conductors. NEC 230.62 (B) / 110.27(A)(1) 8/20/2025 - PREVIOUS INSPECTION NOTES 8/20/25: NO CHANGE FROM PREVIOUS INSPECTION. PLEASE DO NOT SCHEDULE THE RE-INSPECTION UNTIL A COMPANY REPRESENTATIVE VISUALLY VERIFIES THAT THE DEFICIENCY IS RESOLVED TO AVOID WASTING CITY RESOURCES AND TIME. 8/11/2025 - PREVIOUS INSPECTION NOTES 8/11/25: Previously listed deficiency from 1st inspection on 6/20/25 remains unresolved. 1). Exterior disconnect requires service entry barriers over feed side conductors. NEC 230.62 (B) / 110.27(A)(1) and (2) ----------- (NOTE: Main disconnect inside garage is not within line of sight.) (Accidental contact prevention >NEC 230.62 (B) / 110.27(A)(1) and (2)) 8/8/2025 - PREVIOUS INSPECTION NOTES 8/8/25: This inspection will need to be re-scheduled. Could not perform inspection today due to unforseen circumstances. Contact inspector Robert Sims directly with any questions. 6/20/2025 - PREVIOUS INSPECTION NOTES 6/20/25: 1). Exterior disconnect requires service entry barriers over feed side conductors. Main disconnect inside garage is not within line of sight. NEC 240.40/ 690.13(A)
SOLAR ELECTRIC FINAL 08/20/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 8/20/2025 1:58:24 PM *** 8/20/25: NO CHANGE FROM PREVIOUS INSPECTION. PLEASE DO NOT SCHEDULE THE RE-INSPECTION UNTIL A COMPANY REPRESENTATIVE VISUALLY VERIFIES THAT THE DEFICIENCY IS RESOLVED TO AVOID WASTING CITY RESOURCES AND TIME. 8/11/2025 - PREVIOUS INSPECTION NOTES 8/11/25: Previously listed deficiency from 1st inspection on 6/20/25 remains unresolved. 1). Exterior disconnect requires service entry barriers over feed side conductors. NEC 230.62 (B) / 110.27(A)(1) and (2) ----------- (NOTE: Main disconnect inside garage is not within line of sight.) (Accidental contact prevention >NEC 230.62 (B) / 110.27(A)(1) and (2)) 8/8/2025 - PREVIOUS INSPECTION NOTES 8/8/25: This inspection will need to be re-scheduled. Could not perform inspection today due to unforseen circumstances. Contact inspector Robert Sims directly with any questions. 6/20/2025 - PREVIOUS INSPECTION NOTES 6/20/25: 1). Exterior disconnect requires service entry barriers over feed side conductors. Main disconnect inside garage is not within line of sight. NEC 240.40/ 690.13(A)
SOLAR ELECTRIC FINAL 08/11/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 8/11/2025 11:43:03 AM *** 8/11/25: Previously listed deficiency from 1st inspection on 6/20/25 remains unresolved. 1). Exterior disconnect requires service entry barriers over feed side conductors. NEC 230.62 (B) / 110.27(A)(1) and (2) ----------- (NOTE: Main disconnect inside garage is not within line of sight.) (Accidental contact prevention >NEC 230.62 (B) / 110.27(A)(1) and (2)) 8/8/2025 - PREVIOUS INSPECTION NOTES 8/8/25: This inspection will need to be re-scheduled. Could not perform inspection today due to unforseen circumstances. Contact inspector Robert Sims directly with any questions. 6/20/2025 - PREVIOUS INSPECTION NOTES 6/20/25: 1). Exterior disconnect requires service entry barriers over feed side conductors. Main disconnect inside garage is not within line of sight. NEC 240.40/ 690.13(A)
SOLAR ELECTRIC FINAL 08/08/2025 CANCELLED BY APPLICANT RSIMS
Note: *** NOTES ADDED BY RSIMS 8/8/2025 11:30:39 AM *** 8/8/25: This inspection will need to be re-scheduled. Could not perform inspection today due to unforseen circumstances. Contact inspector Robert Sims directly with any questions. 6/20/2025 - PREVIOUS INSPECTION NOTES 6/20/25: 1). Exterior disconnect requires service entry barriers over feed side conductors. Main disconnect inside garage is not within line of sight. NEC 240.40/ 690.13(A)
SOLAR ELECTRIC FINAL 06/20/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 6/20/2025 12:00:05 PM *** 6/20/25: 1). Exterior disconnect requires service entry barriers over feed side conductors. Main disconnect inside garage is not within line of sight. NEC 240.40/ 690.13(A)

Review History

Department Status Date In Date Out
BLD COMPLETE 06/03/2025 06/03/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 06/03/2025 06/03/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 09/10/2025
REINSPECTION RESIDENTIAL ¤40.00 08/25/2025
REINSPECTION RESIDENTIAL ¤40.00 08/19/2025
REINSPECTION RESIDENTIAL ¤40.00 08/06/2025
SURCHARGE FS 533.721 ¤2.00 06/05/2025
SURCHARGE - FS 468.631 ¤2.73 06/05/2025
ADJUSTMENT 10% (¤20.23) 06/05/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 06/05/2025
INSPECTION - RESIDENTIAL ¤107.25 06/05/2025
SOLAR PLAN REVIEW ¤65.00 06/05/2025
Fees Total Due: ¤0.00 Total Paid: ¤346.75