Permit #2025060230

Permit Details

Status: INSPECT

Subdivision: 2328 - OCEAN VILLAGE MF
Job Phone: 904-208-2000
Location Address: 400 OCEAN VILLAGE CIR
Type: CDBA - COMMERCIAL DETACHED BUILDING
Issue Date: 02/10/2026
NOC: Unknown
Applicant name: WILLIAM KEITH FAVER
Owner: GJE OV FL100, LLC

Address

PO BOX 3205

VALDOSTA, GA 31064

Contracted Stated Job Value: ¤97,440.92
Job Description: GARAGE 19
Type: CN

Contractor

THE FAVERGRAY COMPANY
Status Location Address Mailing Address State License Number Phone
ACTIVE

415 PABLO AVENUE

JACKSONVILLE, FL 32250

STE200

JACKSONVILLE, FL 32250

CGC1512983 (Exp: 08/31/2026) 904-208-2000

Sub Contractors

TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733

Inspection History

Type Request Date Result Inspector
FORMBOARD SURVEY 05/18/2026 APPROVED DLEAP
EXTERIOR WALL SHEATHING / SHEARWALL 05/18/2026
ROOF SHEATHING / BRACE / TIE DOWN 05/18/2026
BUILDING FINAL
FIRE FINAL
ELECTRIC 2ND ROUGH
ELECTRIC FINAL
LATH/BRICK/WATER BARRIER
FRAMING
FIREWALL FRAMING
FIREWALL FINAL
FIREWALL PENETRATIONS

Review History

Department Status Date In Date Out
ELEC COMPLETE 06/09/2026 06/10/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
DSD COMPLETE 06/03/2026 06/04/2026
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ELEC HOLD 06/03/2026 06/05/2026
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Can not read the electric vehicle supply that was pasted on the plans.
PLENG COMPLETE 05/15/2026 05/18/2026
Note: Released By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM
PLENG HOLD 04/30/2026 04/30/2026
Note: Held By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM 1. Formboard survey should have ties to property lines.
ELEC HOLD 03/30/2026 04/01/2026
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Can not read the electric vehicle supply that was pasted on the plans.
DSD COMPLETE 12/12/2025 12/12/2025
Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM
DSD HOLD 10/10/2025 10/21/2025
Note: Held By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM Need to have approved Development Order for early starts process. See previous repeat comments.
ARCHR COMPLETE 10/10/2025 10/20/2025
Note: Released By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM
BLD COMPLETE 10/10/2025 10/16/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
DSD HOLD 09/19/2025 09/23/2025
Note: Held By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM Held By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM All documents must be provided via this link below and not submitted part of the building permit. https://old.palmcoastgov.com/government/planning/online-app App type will be a Project Phasing for Site Improvements. Prior to issuance of building permits, all life- safety facilities necessary to support access and safety of the site by first responders must be in place completed and functioning for their intended purpose. These life-safety facilities are in addition to water, wastewater and stormwater facilities (including DEP certification), fire-protection and, at a minimum, stabilized fire access roads Site Improvement Requirements: 1. Provide a complete written project construction phasing schedule explaining and outlining the intended sequencing and completion of all site improvements. a. In conjunction with the written narrative above, provide a Site Plan defining by markings, each construction phase and note the order of completion of each phase and all buildings, facilities and other site features and amenities intended to be completed within each phase. b. Provide intended completion schedules for all site improvements and facilities to be completed in each phase to include parking lots / areas, recreation trails, dog parks, outdoor amenities such as recreation courts, fields and similar, mail kiosks, amenity centers, gyms, swimming pools, fishing piers, gazebos, pavilions and any other facility described in the Development Plans. c. Indicate areas where the first lift of asphalt will be provided. Include a completion schedule for the second and final lift of asphalt is to be completed. Provide a timeline of when the temporary and permanent stripping is to be complete. d. Indicate areas of temporary parking and roadway markings / striping. Provide a completion schedule of when the temporary and permanent striping is to be completed. e. Indicate the installation of landscaping around buildings and in different areas of the site such as common areas, parking areas, recreation and in what stages will they be installed 2. Identify location of fire department access roads through site. a. Indicate whether access roads or portions thereof will be permanent or temporary, stabilized roads. b. Indicate points of site ingress and egress. c. Provide minimum clear widths of 20 feet for one direction access roads and 24 feet for two-way access roads. d. For access roads exceeding 150 feet in length, indicate path of travel to site egress without backing or turning. e. Dead-end access roads of more than 150 feet in length shall be provided with a full-movement turn-around of 104 feet in diameter to accommodate fire apparatus. f. Indicate fire access roads will extend to within 50 feet of at least one entry to all buildings. g. For temporary, stabilized access roads provide a roadway cross section and material details by the project engineer able to support 75,000 pound fire apparatus and an all-weather surface. h. Add notes to indicate temporary, stabilized fire access roads to be maintained by the project developer and deficiencies identified by the Palm Coast Fire Department shall be promptly corrected by the developer to the satisfaction of the Palm Coast Fire Department. 3. Please provide a note on the plans stating: The required fire hydrants and water supply will be installed, flow tested, and flow test reports submitted to the Palm Coast Building Department for review and approval. No storage of combustible materials and no vertical construction is permitted to occur until fire-flow test reports have been approved. If completion of water supply and fire hydrants is intended to be part of a Phasing Plan, then fire hydrants intended to be “in-service” shall be shown in conjunction with each phase. 4. Denote and map area for FDEP partial clearance for water main on-site plan. 5. A sign is required to be located on each building at a location approved by the City stating the following: “NOTICE: DO NOT CONNECT WATER OR SEWER LINES”. This sign should be in English and Spanish. (See Exhibit B). Signs are required to be maintained and always in vertical position. 6. If this site has a SWPPP on file all requirements listed in this plan must be met to include the stabilization of areas not to be built on with seeds. 7. Issuance of building permits shall also conform to requirements of other City departments and divisions. 8. When submitting for a modification to the DO submit all pictures with the signs posted on each proposed building location, DEP clearance and all test preformed on the water system.
ARCHR HOLD 09/19/2025 09/26/2025
Note: Held By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM 1. Provide at least (2) two articulations on rear facade of garage due its visibility from Future builidng Mix 4 Ph 2 - accross the street[recommend H2 sutters].
BLD COMPLETE 09/19/2025 09/23/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
FI1 COMPLETE 07/25/2025 07/28/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
DSD HOLD 07/25/2025 07/28/2025
Note: Held By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM All documents must be provided via this link below and not submitted part of the building permit. https://old.palmcoastgov.com/government/planning/online-app App type will be a Project Phasing for Site Improvements. Prior to issuance of building permits, all life- safety facilities necessary to support access and safety of the site by first responders must be in place completed and functioning for their intended purpose. These life-safety facilities are in addition to water, wastewater and stormwater facilities (including DEP certification), fire-protection and, at a minimum, stabilized fire access roads Site Improvement Requirements: 1. Provide a complete written project construction phasing schedule explaining and outlining the intended sequencing and completion of all site improvements. a. In conjunction with the written narrative above, provide a Site Plan defining by markings, each construction phase and note the order of completion of each phase and all buildings, facilities and other site features and amenities intended to be completed within each phase. b. Provide intended completion schedules for all site improvements and facilities to be completed in each phase to include parking lots / areas, recreation trails, dog parks, outdoor amenities such as recreation courts, fields and similar, mail kiosks, amenity centers, gyms, swimming pools, fishing piers, gazebos, pavilions and any other facility described in the Development Plans. c. Indicate areas where the first lift of asphalt will be provided. Include a completion schedule for the second and final lift of asphalt is to be completed. Provide a timeline of when the temporary and permanent stripping is to be complete. d. Indicate areas of temporary parking and roadway markings / striping. Provide a completion schedule of when the temporary and permanent striping is to be completed. e. Indicate the installation of landscaping around buildings and in different areas of the site such as common areas, parking areas, recreation and in what stages will they be installed 2. Identify location of fire department access roads through site. a. Indicate whether access roads or portions thereof will be permanent or temporary, stabilized roads. b. Indicate points of site ingress and egress. c. Provide minimum clear widths of 20 feet for one direction access roads and 24 feet for two-way access roads. d. For access roads exceeding 150 feet in length, indicate path of travel to site egress without backing or turning. e. Dead-end access roads of more than 150 feet in length shall be provided with a full-movement turn-around of 104 feet in diameter to accommodate fire apparatus. f. Indicate fire access roads will extend to within 50 feet of at least one entry to all buildings. g. For temporary, stabilized access roads provide a roadway cross section and material details by the project engineer able to support 75,000 pound fire apparatus and an all-weather surface. h. Add notes to indicate temporary, stabilized fire access roads to be maintained by the project developer and deficiencies identified by the Palm Coast Fire Department shall be promptly corrected by the developer to the satisfaction of the Palm Coast Fire Department. 3. Please provide a note on the plans stating: The required fire hydrants and water supply will be installed, flow tested, and flow test reports submitted to the Palm Coast Building Department for review and approval. No storage of combustible materials and no vertical construction is permitted to occur until fire-flow test reports have been approved. If completion of water supply and fire hydrants is intended to be part of a Phasing Plan, then fire hydrants intended to be “in-service” shall be shown in conjunction with each phase. 4. Denote and map area for FDEP partial clearance for water main on-site plan. 5. A sign is required to be located on each building at a location approved by the City stating the following: “NOTICE: DO NOT CONNECT WATER OR SEWER LINES”. This sign should be in English and Spanish. (See Exhibit B). Signs are required to be maintained and always in vertical position. 6. If this site has a SWPPP on file all requirements listed in this plan must be met to include the stabilization of areas not to be built on with seeds. 7. Issuance of building permits shall also conform to requirements of other City departments and divisions. 8. When submitting for a modification to the DO submit all pictures with the signs posted on each proposed building location, DEP clearance and all test preformed on the water system.
BLD COMPLETE 07/25/2025 07/28/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ARCHR HOLD 07/25/2025 08/01/2025
Note: Held By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM the rear facade of each garage building shall have a minimum 1 articulation and 1 massing technique per LDC section 3.04.02 A
ARCHR HOLD 06/05/2025 06/12/2025
Note: Held By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM Pwe LDC SEC 13.04.01 A, B, & C - Provide additional architectural features to rear facade of garage including articulations, massing and fenestrattion
BFLOOD CANCEL 06/05/2025 06/11/2025
BLD HOLD 06/05/2025 06/11/2025
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM ALL COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING (FBCB), FLORIDA BUILDING CODE-ACCESSIBILITY (FBCA), FLORIDA BUILDING CODE-PLUMBING (FBCP), FLORIDA STATUTES (FS), FLORIDA ADMINISTRATIVE CODE (FAC) AND AUTHORITY HAVING JURISDICTION (AHJ). PLAN RE-SUBMITTAL SHALL BE ACCOMPANIED BY A RESPONSE LETTER SIGNED AND SEALED BY THE APPROPRIATE DESIGN PROFESSIONAL(S). ALL PLAN REVISIONS SHALL BE CLOUDED APPROPRIATELY. 1. Garages need to be classified as Group U. FBC 2023 406.3.1 2. Show the distances between the garages and property lines 3. Plan page A060 reference the 7th edition FBC. Need to update. 4. Plan page A060 references a wall UL detail that is not uploaded to the permit. Upload and provide detail. 5. Provide a response letter stating which details are for the garages. You have plan sheets that don't seem to be for garages. The index sheet will also need to be redone.
DSD HOLD 06/05/2025 06/10/2025
Note: Held By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM Prior to issuance of permits, infrastructure to support the life and safety issues must be met. These are not limit to waste water certification, fire protection, stabilized roads. a. A staging plan. The staging plan must show the order these buildings will be CO’d. b. Show Ingress and egress. c. Please provide a note on the plans stating: The required fire hydrants and supply will be installed, tested, and in service for prior to combustible materials being delivered per FFPC 1, section 16.5.3 d. Show stabilized road. Stabilized access roads shall be maintained by the project developer and deficiencies observed by the Palm Coast Fire Department shall be promptly corrected to the satisfaction of the Palm Coat Fire Department. e. Temporary Cul-de-sac for fire trucks (as applicable). If a Cul-da-sac is needed add a note to your temporary cul-de-sac detail that the roadway must be able to support a 75,000-pound vehicle. f. Denote and map area for FDEP partial clearance for water main on-site plan. g. A sign is required to be located on building location stating the following: “NOTICE: DO NOT CONNECT WATER OR SEWER LINES”. This sign should be in English and Spanish. (See Exhibit B). Signs are required to be maintained and always in vertical position. If this site has a SWPPP on file all requirements listed in this plan must be met to include the stabalization of areas not to be built on with seeds. h. Issuance of permits shall also conform to requirements of other City departments and divisions. When submitting for a modification to the DO submit all pictures with the signs posted on each proposed building location, DEP clearance and all test preformed on the waste water system.
ELEC COMPLETE 06/05/2025 06/09/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
FI1 HOLD 06/05/2025 06/09/2025
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Please provide detail for Fire Fighter Safety Building Marking System per Florida Administrative Code 69A-3.012 and Florida Statutes 633.027 2. Please include the 8th edition (2023) Florida Fire Prevention Code 3. NFPA 1 and 101 need to be 2021 code year
MECH CANCEL 06/05/2025 06/12/2025
PLUM CANCEL 06/05/2025 06/12/2025
UD1 COMPLETE 06/05/2025 06/10/2025
Note: Released By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 10% (¤24.77) 02/10/2026
ADMINISTRATIVE - COMMERCIAL PP ¤450.00 02/10/2026
ADMINISTRATIVE - COMMERCIAL ¤75.00 02/10/2026
INSPECTION - FIRE COMMERCIAL ¤60.00 02/10/2026
PLAN REVIEW - COMMERCIAL ¤112.70 02/10/2026
SURCHARGE FS 533.721 ¤6.73 02/10/2026
SURCHARGE - FS 468.631 ¤10.10 02/10/2026
SITE PLAN 30 ¤30.00 02/10/2026
IMPACT FEE FIRE ¤1,166.20
Fees Total Due: ¤1,166.20 Total Paid: ¤719.76