I want to search for...
Permit #2025060239
Permit Details
Status: COED
| Parcel Id: 07-11-31-7028-00740-0150 |
| CONDITIONED SPACE: 1809 sqft |
| GARAGE: 406 sqft |
| OPENED PORCH (WITH ROOF) : 33 sqft |
| Total Square Footage: 2248 sqft |
| Block: 00740 |
| Subdivision: - |
| Job Phone: 239-571-5325 |
| Location Address: 29 POINDEXTER LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 06/24/2025 |
| NOC: RECORDED |
| Applicant name: RYAN SCOTT DAVIS |
| Owner: SYNERGY HOMES LLC |
|
Address 581 NW MERCANTILE PLACE PORT SAINT LUCIE, FL 34986 |
|
Address SUITE 106 PORT SAINT LUCIE, FL 34986 |
| Lot: 0150 |
| Contracted Stated Job Value: ¤200,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
SYNERGY HOMES, LLC
| Status | Location Address | State License Number |
| ACTIVE |
1 HARGROVE GRADE, SUITE B1 PALM COAST, FL 32137 |
CBC1254289 (Exp: 08/31/2026) |
Sub Contractors
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
TERRY BRICE DICKERSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4300 ST JOHN'S PARKWAY ALPHARETTA, GA 30009 |
CCC1326209 (Exp: 08/31/2026) | 407-548-6733 |
MICHAEL FRANK MORELLO
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2 HARGROVE GRADE PALM COAST, FL 32164 |
CAC1819466 (Exp: 08/31/2026) | 386-445-5023 | 386-446-4614 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - FINAL APRON (AFTER POUR) | 12/12/2025 | APPROVED | FSLADISH |
| Note: 12/12/25 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. Inspector Notes from Inspection 9465 12/11/25 UPON WALKING PROPERTY DETERMINED THAT BUILDER WILL NEED TO ADD A SMALL SWALE/BERM IN REAR RIGHT CORNER TO MOVE DRAINAGE AROUND AND FORWARD AS THE WAY THE REAR YARD SLOPES IS FROM LEFT TO RIGHT. GRAYSON INDICATED HE WILL GET IT DONE. | |||
| ROW - STORMWATER FINAL | 12/12/2025 | APPROVED | FSLADISH |
| Note: 12/12/25 REQUIRED SWALE/BERM CORRECTION COMPLETED AT THE TIME OF THIS INSPECTION. DUE TO IT BEING A SMALL AREA,i AM NOT REQUIRING A NEW SURVEY TO BE SUBMITTED. DRAINGE NOW CONFORMS TO MINIMUM COPC STANDARDS. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ________________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 12/11/25 UPON WALKING PROPERTY DETERMINED THAT BUILDER WILL NEED TO ADD A SMALL SWALE/BERM IN REAR RIGHT CORNER TO MOVE DRAINAGE AROUND AND FORWARD AS THE WAY THE REAR YARD SLOPES IS FROM LEFT TO RIGHT. GRAYSON INDICATED HE WILL GET IT DONE. | |||
| U -UTILITY RESIDENTIAL FINAL | 12/12/2025 | Disapproved -FEE REQUIRED | BWRIGHT |
| Note: Inspector Notes from Inspection 9035 no irr-no cc No power to PEP TANK | |||
| U -UTILITY RESIDENTIAL FINAL | 12/12/2025 | FINAL APPROVED | LFITZGERALD |
| Note: 12/12/2025 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 9035 no irr-no cc No power to PEP TANK | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/11/2025 | APPROVED | FSLADISH |
| Note: 12/9/2025 - PREVIOUS INSPECTION NOTES 12-9-25 TPOLACEK*** THE FFE ON THE FORMBOARD SURVEY INDICATES 26.70, FINAL SURVEY INDICATES 26.17 THIS MUST BE CORRECTED. THERE IS A SHOT OF 25.40 IN THE BACK LEFT THAT IS .20 LOW AND WILL TRAP WATER. THERE ARE NO 10' OFF SHOTS IN THE REAR ALONG EASEMENT, | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 12/11/2025 | APPROVED - AS NOTED | FSLADISH |
| Note: 12/11/25 UPON WALKING PROPERTY DETERMINED THAT BUILDER WILL NEED TO ADD A SMALL SWALE/BERM IN REAR RIGHT CORNER TO MOVE DRAINAGE AROUND AND FORWARD AS THE WAY THE REAR YARD SLOPES IS FROM LEFT TO RIGHT. GRAYSON INDICATED HE WILL GET IT DONE. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/09/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 12-9-25 TPOLACEK*** THE FFE ON THE FORMBOARD SURVEY INDICATES 26.70, FINAL SURVEY INDICATES 26.17 THIS MUST BE CORRECTED. THERE IS A SHOT OF 25.40 IN THE BACK LEFT THAT IS .20 LOW AND WILL TRAP WATER. THERE ARE NO 10' OFF SHOTS IN THE REAR ALONG EASEMENT, | |||
| BLD - BUILDING FINAL | 12/02/2025 | FINAL APPROVED | MCONTRYMAN |
| Note: 11/25/2025 - PREVIOUS INSPECTION NOTES 11/25/25: Cancelled by Applicant via phone at @ 1215. Stated not ready scheduled too early. | |||
| BLD - BUILDING FINAL | 11/25/2025 | CANCELLED BY APPLICANT | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/25/2025 12:18:03 PM *** 11/25/25: Cancelled by Applicant via phone at @ 1215. Stated not ready scheduled too early. | |||
| ROW- PRE-APRON (PRE-POUR) | 11/10/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. Inspector Notes from Inspection 9470 09-29-25 TPOLACEK*** BUILDER WAS OPENING SWALE AT PROPERTY LINE WHILE I WAS CONDUCTING INSPECTION. APPROVING AS NOTED ++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/24/2025 - PREVIOUS INSPECTION NOTES 09-24-25 TPOLACEK*** BUILDER NEEDS TO REESTABLISH TEMPORARY PIPE AND SILT FENCE ACROSS RIGHT SIDE SWALE. 3 DAYS Inspector Notes from Inspection 9470 8/5/25 REQUIRED CORRECTIONS COMPLETED AT THE TIME OF THE DRAINAGE REINSPECTION. IT IS THE BUILDERS RESPONSIBILITY TO MAINTAIN CONSTRUCTUION SITE TO COPC STANDARDS THROUGHOUT THE CONSTRUCTION PROCESS. WILL MONITOR SITE FOR CONTINUED COMPLIANCE. ______________________________________________________________________________________________________________________ 7/31/2025 - PREVIOUS INSPECTION NOTES 07/31/25 TPOLACEK*** BUILDER HAS TILL MONDAY 08/04/25 TO COMPLY BEFORE A PRIORITY 1 STATUS IS APPLIED TO PERMIT. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 7/21/2025 - PREVIOUS INSPECTION NOTES 07/21/25 TPOLACEK*** BUILDER WILL NEED TO INSTALL SILT FENCE ACROSS FRONT LEAVING CONSTRUCTION ENTRANCE OPENING ONLY AND MAKE SURE SWALE IS KEPT OPEN OR INSTALL TEMPORARY CULVERT. 10 DAYS BEFORE REINSPECTION. SEE DETAIL IN PHOTO SECTION. | |||
| GRAVITY SEWER TEST | 11/10/2025 | APPROVED | MGIBSON |
| SEWER TIE IN | 11/10/2025 | APPROVED | MGIBSON |
| ELECTRIC - EARLY POWER | 10/29/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 10/29/2025 11:50:35 AM *** 5/29/25: FPL emailed to release power. | |||
| PEP TANK INSTALLATION REQUEST | 10/16/2025 | APPROVED | CBOWERMASTER |
| INSULATION | 10/02/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 10/2/2025 2:53:14 PM *** | |||
| ROW - DRAINAGE | 09/29/2025 | APPROVED - AS NOTED | TPOLACEK |
| Note: 09-29-25 TPOLACEK*** BUILDER WAS OPENING SWALE AT PROPERTY LINE WHILE I WAS CONDUCTING INSPECTION. APPROVING AS NOTED ++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/24/2025 - PREVIOUS INSPECTION NOTES 09-24-25 TPOLACEK*** BUILDER NEEDS TO REESTABLISH TEMPORARY PIPE AND SILT FENCE ACROSS RIGHT SIDE SWALE. 3 DAYS Inspector Notes from Inspection 9470 8/5/25 REQUIRED CORRECTIONS COMPLETED AT THE TIME OF THE DRAINAGE REINSPECTION. IT IS THE BUILDERS RESPONSIBILITY TO MAINTAIN CONSTRUCTUION SITE TO COPC STANDARDS THROUGHOUT THE CONSTRUCTION PROCESS. WILL MONITOR SITE FOR CONTINUED COMPLIANCE. ______________________________________________________________________________________________________________________ 7/31/2025 - PREVIOUS INSPECTION NOTES 07/31/25 TPOLACEK*** BUILDER HAS TILL MONDAY 08/04/25 TO COMPLY BEFORE A PRIORITY 1 STATUS IS APPLIED TO PERMIT. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 7/21/2025 - PREVIOUS INSPECTION NOTES 07/21/25 TPOLACEK*** BUILDER WILL NEED TO INSTALL SILT FENCE ACROSS FRONT LEAVING CONSTRUCTION ENTRANCE OPENING ONLY AND MAKE SURE SWALE IS KEPT OPEN OR INSTALL TEMPORARY CULVERT. 10 DAYS BEFORE REINSPECTION. SEE DETAIL IN PHOTO SECTION. | |||
| ALL ROUGH | 09/29/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 9/29/2025 10:43:53 AM *** Inspector Notes from Inspection 2320 *** NOTES ADDED BY RSIMS 9/24/2025 2:38:54 PM *** 9/24/25: Approved as noted. Check at All Rough. 1). Trusses B2 and B4 need to be plumbed/straightened. 2). Trusses C2 and C3 need dirt cleaned off so that original integrity can be visually verified. 9/23/2025 - PREVIOUS INSPECTION NOTES 9/23/25: 1). Left side of house. Lath required over large hole in CMU at low voltage cables. FBC [A]107.4 / FBC EC TABLE R402.4.1.1 Checked previous notes and they still need to be resolved. Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 9/18/2025 11:45:58 AM *** 9/18/25: CHECK AT NEXT INSPECTION. 1). Trusses B2 and B4 need to be plumbed/straightened. 2). Trusses C2 and C3 need dirt cleaned off so that original integrity can be visually verified. Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 9/8/2025 9:37:44 AM *** 9/8/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Window Sill mortar beds and/or Concrete Block joints exceed the maximum thickness (sills - 1/2" / CMU joints - 3/8") per FBC-R606.3.1 - Marked with red paint. | |||
| LATH/BRICK/ WATER BARRIER | 09/24/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 9/24/2025 2:38:54 PM *** 9/24/25: Approved as noted. Check at All Rough. 1). Trusses B2 and B4 need to be plumbed/straightened. 2). Trusses C2 and C3 need dirt cleaned off so that original integrity can be visually verified. 9/23/2025 - PREVIOUS INSPECTION NOTES 9/23/25: 1). Left side of house. Lath required over large hole in CMU at low voltage cables. FBC [A]107.4 / FBC EC TABLE R402.4.1.1 Checked previous notes and they still need to be resolved. Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 9/18/2025 11:45:58 AM *** 9/18/25: CHECK AT NEXT INSPECTION. 1). Trusses B2 and B4 need to be plumbed/straightened. 2). Trusses C2 and C3 need dirt cleaned off so that original integrity can be visually verified. Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 9/8/2025 9:37:44 AM *** 9/8/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Window Sill mortar beds and/or Concrete Block joints exceed the maximum thickness (sills - 1/2" / CMU joints - 3/8") per FBC-R606.3.1 - Marked with red paint. | |||
| ROW - DRAINAGE | 09/24/2025 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 09-24-25 TPOLACEK*** BUILDER NEEDS TO REESTABLISH TEMPORARY PIPE AND SILT FENCE ACROSS RIGHT SIDE SWALE. 3 DAYS Inspector Notes from Inspection 9470 8/5/25 REQUIRED CORRECTIONS COMPLETED AT THE TIME OF THE DRAINAGE REINSPECTION. IT IS THE BUILDERS RESPONSIBILITY TO MAINTAIN CONSTRUCTUION SITE TO COPC STANDARDS THROUGHOUT THE CONSTRUCTION PROCESS. WILL MONITOR SITE FOR CONTINUED COMPLIANCE. ______________________________________________________________________________________________________________________ 7/31/2025 - PREVIOUS INSPECTION NOTES 07/31/25 TPOLACEK*** BUILDER HAS TILL MONDAY 08/04/25 TO COMPLY BEFORE A PRIORITY 1 STATUS IS APPLIED TO PERMIT. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 7/21/2025 - PREVIOUS INSPECTION NOTES 07/21/25 TPOLACEK*** BUILDER WILL NEED TO INSTALL SILT FENCE ACROSS FRONT LEAVING CONSTRUCTION ENTRANCE OPENING ONLY AND MAKE SURE SWALE IS KEPT OPEN OR INSTALL TEMPORARY CULVERT. 10 DAYS BEFORE REINSPECTION. SEE DETAIL IN PHOTO SECTION. | |||
| LATH/BRICK/ WATER BARRIER | 09/23/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 9/23/2025 9:12:47 AM *** 9/23/25: 1). Left side of house. Lath required over large hole in CMU at low voltage cables. FBC [A]107.4 / FBC EC TABLE R402.4.1.1 Checked previous notes and they still need to be resolved. Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 9/18/2025 11:45:58 AM *** 9/18/25: CHECK AT NEXT INSPECTION. 1). Trusses B2 and B4 need to be plumbed/straightened. 2). Trusses C2 and C3 need dirt cleaned off so that original integrity can be visually verified. Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 9/8/2025 9:37:44 AM *** 9/8/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Window Sill mortar beds and/or Concrete Block joints exceed the maximum thickness (sills - 1/2" / CMU joints - 3/8") per FBC-R606.3.1 - Marked with red paint. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/18/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 9/18/2025 11:45:58 AM *** 9/18/25: CHECK AT NEXT INSPECTION. 1). Trusses B2 and B4 need to be plumbed/straightened. 2). Trusses C2 and C3 need dirt cleaned off so that original integrity can be visually verified. Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 9/8/2025 9:37:44 AM *** 9/8/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Window Sill mortar beds and/or Concrete Block joints exceed the maximum thickness (sills - 1/2" / CMU joints - 3/8") per FBC-R606.3.1 - Marked with red paint. | |||
| ROOF VALLEY & METAL | 09/17/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 9/17/2025 9:14:17 AM *** Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 9/8/2025 9:37:44 AM *** 9/8/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Window Sill mortar beds and/or Concrete Block joints exceed the maximum thickness (sills - 1/2" / CMU joints - 3/8") per FBC-R606.3.1 - Marked with red paint. | |||
| WALL SHEATHING | 09/17/2025 | APPROVED | RSIMS |
| Note: Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 9/8/2025 9:37:44 AM *** 9/8/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Window Sill mortar beds and/or Concrete Block joints exceed the maximum thickness (sills - 1/2" / CMU joints - 3/8") per FBC-R606.3.1 - Marked with red paint. | |||
| TIE BEAM / LINTEL | 09/08/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 9/8/2025 9:37:44 AM *** 9/8/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Window Sill mortar beds and/or Concrete Block joints exceed the maximum thickness (sills - 1/2" / CMU joints - 3/8") per FBC-R606.3.1 - Marked with red paint. | |||
| MONOLITHIC SLAB | 08/28/2025 | APPROVED | JSTEWART |
| Note: 8/27/2025 - PREVIOUS INSPECTION NOTES 8/27/25: NOTE: RAIN HAS CAUSED MINOR CAVE-IN AT MISCELLANEOUS AREAS AND FLOODED MOST OF THE FOOTERS SO THAT REBAR CLEARANCE ALONG WITH ANY ADDITIONAL CAVE-IN, ETC CAN NOT BE CHECKED/VERIFIED. FBC-[A] 110.1 8/26/2025 - PREVIOUS INSPECTION NOTES 1. Deep footing not per detail marked on 2.0 FD, calls for 4 #5 each way 2. Clean footings out so they are free from debris and proper clearence to rebar from earth FBC R404.1.3.3.7.4 3. Seal all penotrations in vapor barrier FBC R506.2.3 4. A/C line set chase requires a relieving arch FBCR P2603.4 | |||
| MONOLITHIC SLAB | 08/27/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 8/27/2025 1:46:47 PM *** 8/27/25: NOTE: RAIN HAS CAUSED MINOR CAVE-IN AT MISCELLANEOUS AREAS AND FLOODED MOST OF THE FOOTERS SO THAT REBAR CLEARANCE ALONG WITH ANY ADDITIONAL CAVE-IN, ETC CAN NOT BE CHECKED/VERIFIED. FBC-[A] 110.1 8/26/2025 - PREVIOUS INSPECTION NOTES 1. Deep footing not per detail marked on 2.0 FD, calls for 4 #5 each way 2. Clean footings out so they are free from debris and proper clearence to rebar from earth FBC R404.1.3.3.7.4 3. Seal all penotrations in vapor barrier FBC R506.2.3 4. A/C line set chase requires a relieving arch FBCR P2603.4 | |||
| MONOLITHIC SLAB | 08/26/2025 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Deep footing not per detail marked on 2.0 FD, calls for 4 #5 each way 2. Clean footings out so they are free from debris and proper clearence to rebar from earth FBC R404.1.3.3.7.4 3. Seal all penotrations in vapor barrier FBC R506.2.3 4. A/C line set chase requires a relieving arch FBCR P2603.4 | |||
| U-CROSS CONNECTION | 08/26/2025 | APPROVED - AS NOTED | LFITZGERALD |
| Note: no irr-no cc | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 08/22/2025 | APPROVED | MGIBSON |
| Note: 8/20/2025 - PREVIOUS INSPECTION NOTES 8/20/25: NOT READY! CONTRACTOR STILL WORKING ON INSTALLATION. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 08/20/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 8/20/2025 11:50:06 AM *** 8/20/25: NOT READY! CONTRACTOR STILL WORKING ON INSTALLATION. | |||
| FORMBOARD SURVEY (OFFICE USE ONLY) | 08/14/2025 | APPROVED | RRICKS |
| WATER METER INSTALLATION REQUEST | 08/12/2025 | APPROVED | CBOWERMASTER |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 08/05/2025 | APPROVED | PKNAPIK |
| ROW - DRAINAGE | 08/04/2025 | APPROVED - AS NOTED | FSLADISH |
| Note: 8/5/25 REQUIRED CORRECTIONS COMPLETED AT THE TIME OF THE DRAINAGE REINSPECTION. IT IS THE BUILDERS RESPONSIBILITY TO MAINTAIN CONSTRUCTUION SITE TO COPC STANDARDS THROUGHOUT THE CONSTRUCTION PROCESS. WILL MONITOR SITE FOR CONTINUED COMPLIANCE. ______________________________________________________________________________________________________________________ 7/31/2025 - PREVIOUS INSPECTION NOTES 07/31/25 TPOLACEK*** BUILDER HAS TILL MONDAY 08/04/25 TO COMPLY BEFORE A PRIORITY 1 STATUS IS APPLIED TO PERMIT. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 7/21/2025 - PREVIOUS INSPECTION NOTES 07/21/25 TPOLACEK*** BUILDER WILL NEED TO INSTALL SILT FENCE ACROSS FRONT LEAVING CONSTRUCTION ENTRANCE OPENING ONLY AND MAKE SURE SWALE IS KEPT OPEN OR INSTALL TEMPORARY CULVERT. 10 DAYS BEFORE REINSPECTION. SEE DETAIL IN PHOTO SECTION. | |||
| ROW - DRAINAGE | 07/31/2025 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 07/31/25 TPOLACEK*** BUILDER HAS TILL MONDAY 08/04/25 TO COMPLY BEFORE A PRIORITY 1 STATUS IS APPLIED TO PERMIT. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 7/21/2025 - PREVIOUS INSPECTION NOTES 07/21/25 TPOLACEK*** BUILDER WILL NEED TO INSTALL SILT FENCE ACROSS FRONT LEAVING CONSTRUCTION ENTRANCE OPENING ONLY AND MAKE SURE SWALE IS KEPT OPEN OR INSTALL TEMPORARY CULVERT. 10 DAYS BEFORE REINSPECTION. SEE DETAIL IN PHOTO SECTION. | |||
| ROW - DRAINAGE | 07/21/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 07/21/25 TPOLACEK*** BUILDER WILL NEED TO INSTALL SILT FENCE ACROSS FRONT LEAVING CONSTRUCTION ENTRANCE OPENING ONLY AND MAKE SURE SWALE IS KEPT OPEN OR INSTALL TEMPORARY CULVERT. 10 DAYS BEFORE REINSPECTION. SEE DETAIL IN PHOTO SECTION. |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 08/13/2025 | 08/14/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/13/2025 | 08/13/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 08/04/2025 | 08/05/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 06/17/2025 | 06/18/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Based on information provided this lot is 0.7' (8.4"). Please keep this in mind that the maximum above adjacent lots is 0.83' (10") when construction formboards and pouring slab. | |||
| ENGIN1 | COMPLETE | 06/17/2025 | 06/18/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 06/17/2025 | 06/17/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 06/06/2025 | 06/25/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 06/05/2025 | 06/12/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 06/05/2025 | 06/12/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 06/05/2025 | 06/12/2025 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 06/05/2025 | 06/11/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 06/05/2025 | 06/06/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 06/05/2025 | 06/09/2025 |
| LOCATE | COMPLETE | 06/05/2025 | 06/09/2025 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 06/05/2025 | 06/10/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 06/05/2025 | 06/11/2025 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Please depict berm at the 5' easement. This will minimize the amount of water flow back to the vacant lots. | |||
| ZON | COMPLETE | 06/05/2025 | 06/06/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 12/12/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 12/11/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 12/11/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 12/11/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 12/11/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 12/11/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 06/24/2025 |
| SW ENG PRE APRON | ¤30.00 | 06/24/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 06/24/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 06/24/2025 |
| WATER METER W/ TAP | ¤2,326.93 | 06/24/2025 |
| SEWER CREDIT | (¤2,025.14) | 06/24/2025 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 06/24/2025 |
| WASTEWATER PERM REVIEW | ¤25.00 | 06/24/2025 |
| SEWER CAPITAL FACILITY | ¤4,415.00 | 06/24/2025 |
| WATER CREDIT | (¤1,065.22) | 06/24/2025 |
| WATER CAPITAL FACILITY FEE | ¤3,790.49 | 06/24/2025 |
| WATER PERMIT REVIEW | ¤25.00 | 06/24/2025 |
| WATER MAIN EXTENSION IMPACT | ¤917.27 | 06/24/2025 |
| SITE PLAN 30 | ¤30.00 | 06/24/2025 |
| WASTEWATER MAIN EXTENSION IMPA | ¤2,385.00 | 06/24/2025 |
| SURCHARGE FS 533.721 | ¤10.82 | 06/24/2025 |
| SURCHARGE - FS 468.631 | ¤16.23 | 06/24/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 06/24/2025 |
| WATER- TURN ON | ¤50.00 | 06/24/2025 |
| ADJUSTMENT 10% | (¤120.20) | 06/24/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 06/24/2025 |
| INSPECTION - RESIDENTIAL | ¤913.00 | 06/24/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤258.96 | 06/24/2025 |
| FC IMPACT FEE EMS | ¤62.00 | 06/24/2025 |
| IMPACT FEE FIRE | ¤434.51 | 06/24/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 06/24/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 06/24/2025 |
| IMPACT FEE PARKS | ¤1,828.01 | 06/24/2025 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 06/24/2025 |
| IMPACT FEE TRANSPORTATION | ¤1,916.00 | 06/24/2025 |
| PEP TANK INSTALL | ¤756.74 | 06/24/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤23,486.40 |