I want to search for...
Permit #2025060291
Permit Details
Status: CANCEL
| Parcel Id: 20-12-31-1922-00000-0280 |
| CONDITIONED SPACE: 2388 sqft |
| GARAGE: 464 sqft |
| OPENED PORCH (WITH ROOF) : 120 sqft |
| OPENED PORCH (WITH ROOF) : 48 sqft |
| Total Square Footage: 3020 sqft |
| Subdivision: 2343 - ENCLAVE AT SEMINOLE PALMS |
| Job Phone: 904-541-2326 |
| Location Address: 180 ENCLAVE AVE |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| NOC: NO DOCUMENTATION |
| Applicant name: KENNETH LLOYD SMITH |
| Owner: CRE-KL SEMINOLE WOODS OWNER LLC |
|
Address 14025 RIVEREDGE DR TAMPA, FL 33637 |
|
Address SUITE 175 TAMPA, FL 33637 |
| Lot: 28 |
| Contracted Stated Job Value: ¤250,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
RICHMOND AMERICAN HOMES OF FLORIDA LP
| Status | Location Address | State License Number | Phone |
| ACTIVE |
10255 FORTUNE PARKWAY, STE 150 JACKSONVILLE, FL 32256 |
CGC1519936 (Exp: 08/31/2026) | 904-541-2326 |
Sub Contractors
BRETT CHRISTIAN GIBSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
250 SEGOVIA RD ST AUGUSTINE, FL 32086 |
CAC1818423 (Exp: 08/31/2026) | 904-229-8131 |
JAMES E LINTON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
200 COLLEGE DR ORANGE PARK, FL 32065 |
EC0001152 (Exp: 08/31/2026) | 904-272-0272 |
PAUL ERIC FORSTER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
6114 GOODMAN RD JACKSONVILLE, FL 32244 |
CFC1429261 (Exp: 08/31/2026) | 904-647-1820 |
JAMES T STERLING
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
23 PANTHER LANE PONTE VEDRA, FL 32081 |
SUITE 7 PONTE VEDRA, FL 32081 |
CCC1328645 (Exp: 08/31/2026) | 904-908-4996 |
Inspection History
| Type | Request Date | Result | Inspector |
| FORMBOARD SURVEY (OFFICE USE ONLY) | |||
| PLUMBING 1ST ROUGH UNDERGROUND | |||
| GRAVITY SEWER TEST | |||
| SEWER TIE IN | |||
| ELECTRIC - EARLY POWER | |||
| MONOLITHIC SLAB | |||
| LATH/BRICK/ WATER BARRIER | |||
| ALL ROUGH | |||
| WALL SHEATHING | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | |||
| ROOF VALLEY & METAL | |||
| INSULATION | |||
| BLD - BUILDING FINAL | |||
| WATER METER INSTALLATION REQUEST | |||
| U-CROSS CONNECTION | |||
| ROW- PRE-APRON (PRE-POUR) | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | |||
| ROW - STORMWATER FINAL | |||
| U -UTILITY RESIDENTIAL FINAL |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | COMPLETE | 06/06/2025 | 06/13/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | HOLD | 06/06/2025 | 06/13/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. Plan sheet ST1 Struct Spec not digitally signed or verifiable. | |||
| CUSVC | COMPLETE | 06/06/2025 | 06/12/2025 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 06/06/2025 | 06/12/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 06/06/2025 | 06/09/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 06/06/2025 | 06/11/2025 |
| LOCATE | COMPLETE | 06/06/2025 | 06/09/2025 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 06/06/2025 | 06/11/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Design location on energy calcs and heatload need to be Daytona Beach 2. Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2023 8th Edition 3. Plans show R38 insulation in attic. Energy calcs say R45. Revise to match 4. Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2023 8Th Edition 5. Energy calcs need to have street address 6. Plans show walls at 2x4 with R13. Energy calcs say R19. Revise to match | |||
| SW1 | HOLD | 06/06/2025 | 06/09/2025 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Please provide more elevations in backyard clearly depicting "A" drainage and rear yard drainage swale. | |||
| ZON | HOLD | 06/06/2025 | 06/09/2025 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Provide the percentage of the 4/12 pitched roof on roof plan as it proposed looks to be greater please include the percentage on the plan for approval or update plans to meet code. Pitched roofs. All single-family and duplex buildings shall have a pitched roof covering a minimum of 65 percent of the overall floor area under the roof. Pitched roofs shall have a minimum slope of 5:12 (five inches vertical rise for every 12 inches horizontal run) and shall have an overhang beyond the building wall; however, the overhang shall not encroach into an easement. Flat roofed areas including, but not limited to, porches are permissible in the remaining 35 percent of floor area under roof. | |||
| URB | COMPLETE | 06/06/2025 | 06/12/2025 |
| Note: Released By: MATTHEW SIERRA - (386)286-2002 - MSIERRA@PALMCOASTGOV.COM | |||
| MECH | CANCEL | ||
| BLD | CANCEL | ||
| SW1 | CANCEL | ||
| ZON | CANCEL |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| WATER-METER | ¤874.47 | |
| WATER- TURN ON | ¤50.00 | |
| WATER METER W/OUT TAP | ¤965.03 | |
| RECLAIM WATER PERMIT INSPECTIO | ¤40.00 | |
| SEWER CAPITAL FACILITY | ¤3,725.72 | |
| WATER CAPITAL FACILITY FEE | ¤3,149.89 | |
| Fees | Total Due: ¤8,805.11 | Total Paid: ¤0.00 |