Permit #2025060393

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7064-00070-0030
Block: 00070
Subdivision: 7064 -
Job Phone: 904-864-9366
Location Address: 101 LAGUNA FOREST TRL
Type: GEN - GENERATOR
Issue Date: 06/24/2025
NOC: RECORDED
Applicant name: JACOB HURLEY
Owner: TERRY DON & MARILYN H&W

Address

101 LAGUNA FOREST TRAIL

PALM COAST, FL 32164

Lot: 0030
Contracted Stated Job Value: ¤15,000.00
Job Description: GENERATOR WITH AUTOMATIC TRANSFER SWITCH 2- 120 GAL A/G LP TANKS
Type: CN

Contractor

GENERATOR SUPERCENTER OF JACKSONVILLE
Status Location Address State License Number Phone
ACTIVE

8081 PHILLIPS HWY STE 1

JACKSONVILLE, FL 32256

EC13009708 (Exp: 08/31/2026) 904-379-4189

Sub Contractors

JACOB HURLEY
Status Location Address State License Number Phone
ACTIVE

8081 PHLIPS HWY SUITE 1

, 0

LI45162 (Exp: 10/26/2028) 904-379-4189

Inspection History

Type Request Date Result Inspector
ELECTRIC FINAL 11/13/2025 FINAL APPROVED BTAYLOR
Note: 8/26/2025 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1- add CO Combination smoke detector on living space room behing generaton wall (FBCR M1905.2.5) #2-exhausted combustion need to be 5' from any ignition source , not less #3-Electrical transfer switch need to have 3' off clearance space
GAS FINAL 11/13/2025 FINAL APPROVED BTAYLOR
Note: 11/6/2025 - PREVIOUS INSPECTION NOTES Please fix Item front previous inspection Side tubes need to be and show continuous deep all the way to generator , need to add a 2 or 3 more tubes to show deep all the way . thanks 9/17/2025 - PREVIOUS INSPECTION NOTES SITE TUBES OR DITCH NOTLEFT OPEN FOR INSPECTION 8/26/2025 - PREVIOUS INSPECTION NOTES Please fix item from a previous inspction for final approval Inspector Notes from Inspection 2225 NEED TO HAVE SITE TUBES FOR BURIAL DEPTH OF GAS LINE AT GAS FINAL OR GAS FINAL WILL NOT PASS Inspector Notes from Inspection 2225 NEED TO HAVE SITE TUBES FOR BURIAL DEPTH OF GAS LINE AT GAS FINAL OR GAS FINAL WILL NOT PASS
GAS FINAL 11/06/2025 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Please fix Item front previous inspection Side tubes need to be and show continuous deep all the way to generator , need to add a 2 or 3 more tubes to show deep all the way . thanks 9/17/2025 - PREVIOUS INSPECTION NOTES SITE TUBES OR DITCH NOTLEFT OPEN FOR INSPECTION 8/26/2025 - PREVIOUS INSPECTION NOTES Please fix item from a previous inspction for final approval Inspector Notes from Inspection 2225 NEED TO HAVE SITE TUBES FOR BURIAL DEPTH OF GAS LINE AT GAS FINAL OR GAS FINAL WILL NOT PASS Inspector Notes from Inspection 2225 NEED TO HAVE SITE TUBES FOR BURIAL DEPTH OF GAS LINE AT GAS FINAL OR GAS FINAL WILL NOT PASS
GAS FINAL 09/17/2025 Disapproved -FEE REQUIRED MGIBSON
Note: SITE TUBES OR DITCH NOTLEFT OPEN FOR INSPECTION 8/26/2025 - PREVIOUS INSPECTION NOTES Please fix item from a previous inspction for final approval Inspector Notes from Inspection 2225 NEED TO HAVE SITE TUBES FOR BURIAL DEPTH OF GAS LINE AT GAS FINAL OR GAS FINAL WILL NOT PASS Inspector Notes from Inspection 2225 NEED TO HAVE SITE TUBES FOR BURIAL DEPTH OF GAS LINE AT GAS FINAL OR GAS FINAL WILL NOT PASS
ELECTRIC FINAL 08/26/2025 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Please fix items before next inspection #1- add CO Combination smoke detector on living space room behing generaton wall (FBCR M1905.2.5) #2-exhausted combustion need to be 5' from any ignition source , not less #3-Electrical transfer switch need to have 3' off clearance space
GAS FINAL 08/26/2025 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Please fix item from a previous inspction for final approval Inspector Notes from Inspection 2225 NEED TO HAVE SITE TUBES FOR BURIAL DEPTH OF GAS LINE AT GAS FINAL OR GAS FINAL WILL NOT PASS Inspector Notes from Inspection 2225 NEED TO HAVE SITE TUBES FOR BURIAL DEPTH OF GAS LINE AT GAS FINAL OR GAS FINAL WILL NOT PASS
GAS ROUGH 07/15/2025 APPROVED - AS NOTED MGIBSON
Note: NEED TO HAVE SITE TUBES FOR BURIAL DEPTH OF GAS LINE AT GAS FINAL OR GAS FINAL WILL NOT PASS

Review History

Department Status Date In Date Out
GAS COMPLETE 06/16/2025 06/23/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 06/16/2025 06/16/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ELEC COMPLETE 06/09/2025 06/16/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
GAS HOLD 06/09/2025 06/13/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM site plan shows generator 5ft from the tanks. Revise to show 10ft. generator is an ignition source
ZON COMPLETE 06/09/2025 06/09/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 11/06/2025
REINSPECTION RESIDENTIAL ¤40.00 11/06/2025
REINSPECTION RESIDENTIAL ¤40.00 11/06/2025
REINSPECTION RESIDENTIAL ¤40.00 11/06/2025
SURCHARGE FS 533.721 ¤2.00 06/24/2025
SURCHARGE - FS 468.631 ¤2.00 06/24/2025
SITE PLAN 15 ¤15.00 06/24/2025
ADJUSTMENT 10% (¤12.25) 06/24/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 06/24/2025
INSPECTION - RESIDENTIAL ¤60.00 06/24/2025
PLAN REVIEW - MISC 32.50 ¤32.50 06/24/2025
Fees Total Due: ¤0.00 Total Paid: ¤289.25