Permit #2025060393
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7064-00070-0030 |
| Block: 00070 |
| Subdivision: 7064 - |
| Job Phone: 904-864-9366 |
| Location Address: 101 LAGUNA FOREST TRL |
| Type: GEN - GENERATOR |
| Issue Date: 06/24/2025 |
| NOC: RECORDED |
| Applicant name: JACOB HURLEY |
| Owner: TERRY DON & MARILYN H&W |
|
Address 101 LAGUNA FOREST TRAIL PALM COAST, FL 32164 |
| Lot: 0030 |
| Contracted Stated Job Value: ¤15,000.00 |
| Job Description: GENERATOR WITH AUTOMATIC TRANSFER SWITCH 2- 120 GAL A/G LP TANKS |
| Type: CN |
Contractor
GENERATOR SUPERCENTER OF JACKSONVILLE
| Status | Location Address | State License Number | Phone |
| ACTIVE |
8081 PHILLIPS HWY STE 1 JACKSONVILLE, FL 32256 |
EC13009708 (Exp: 08/31/2026) | 904-379-4189 |
Sub Contractors
JACOB HURLEY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
8081 PHLIPS HWY SUITE 1 , 0 |
LI45162 (Exp: 10/26/2028) | 904-379-4189 |
Inspection History
| Type | Request Date | Result | Inspector |
| ELECTRIC FINAL | 11/13/2025 | FINAL APPROVED | BTAYLOR |
| Note: 8/26/2025 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1- add CO Combination smoke detector on living space room behing generaton wall (FBCR M1905.2.5) #2-exhausted combustion need to be 5' from any ignition source , not less #3-Electrical transfer switch need to have 3' off clearance space | |||
| GAS FINAL | 11/13/2025 | FINAL APPROVED | BTAYLOR |
| Note: 11/6/2025 - PREVIOUS INSPECTION NOTES Please fix Item front previous inspection Side tubes need to be and show continuous deep all the way to generator , need to add a 2 or 3 more tubes to show deep all the way . thanks 9/17/2025 - PREVIOUS INSPECTION NOTES SITE TUBES OR DITCH NOTLEFT OPEN FOR INSPECTION 8/26/2025 - PREVIOUS INSPECTION NOTES Please fix item from a previous inspction for final approval Inspector Notes from Inspection 2225 NEED TO HAVE SITE TUBES FOR BURIAL DEPTH OF GAS LINE AT GAS FINAL OR GAS FINAL WILL NOT PASS Inspector Notes from Inspection 2225 NEED TO HAVE SITE TUBES FOR BURIAL DEPTH OF GAS LINE AT GAS FINAL OR GAS FINAL WILL NOT PASS | |||
| GAS FINAL | 11/06/2025 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: Please fix Item front previous inspection Side tubes need to be and show continuous deep all the way to generator , need to add a 2 or 3 more tubes to show deep all the way . thanks 9/17/2025 - PREVIOUS INSPECTION NOTES SITE TUBES OR DITCH NOTLEFT OPEN FOR INSPECTION 8/26/2025 - PREVIOUS INSPECTION NOTES Please fix item from a previous inspction for final approval Inspector Notes from Inspection 2225 NEED TO HAVE SITE TUBES FOR BURIAL DEPTH OF GAS LINE AT GAS FINAL OR GAS FINAL WILL NOT PASS Inspector Notes from Inspection 2225 NEED TO HAVE SITE TUBES FOR BURIAL DEPTH OF GAS LINE AT GAS FINAL OR GAS FINAL WILL NOT PASS | |||
| GAS FINAL | 09/17/2025 | Disapproved -FEE REQUIRED | MGIBSON |
| Note: SITE TUBES OR DITCH NOTLEFT OPEN FOR INSPECTION 8/26/2025 - PREVIOUS INSPECTION NOTES Please fix item from a previous inspction for final approval Inspector Notes from Inspection 2225 NEED TO HAVE SITE TUBES FOR BURIAL DEPTH OF GAS LINE AT GAS FINAL OR GAS FINAL WILL NOT PASS Inspector Notes from Inspection 2225 NEED TO HAVE SITE TUBES FOR BURIAL DEPTH OF GAS LINE AT GAS FINAL OR GAS FINAL WILL NOT PASS | |||
| ELECTRIC FINAL | 08/26/2025 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: Please fix items before next inspection #1- add CO Combination smoke detector on living space room behing generaton wall (FBCR M1905.2.5) #2-exhausted combustion need to be 5' from any ignition source , not less #3-Electrical transfer switch need to have 3' off clearance space | |||
| GAS FINAL | 08/26/2025 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: Please fix item from a previous inspction for final approval Inspector Notes from Inspection 2225 NEED TO HAVE SITE TUBES FOR BURIAL DEPTH OF GAS LINE AT GAS FINAL OR GAS FINAL WILL NOT PASS Inspector Notes from Inspection 2225 NEED TO HAVE SITE TUBES FOR BURIAL DEPTH OF GAS LINE AT GAS FINAL OR GAS FINAL WILL NOT PASS | |||
| GAS ROUGH | 07/15/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: NEED TO HAVE SITE TUBES FOR BURIAL DEPTH OF GAS LINE AT GAS FINAL OR GAS FINAL WILL NOT PASS |
Review History
| Department | Status | Date In | Date Out |
| GAS | COMPLETE | 06/16/2025 | 06/23/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 06/16/2025 | 06/16/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 06/09/2025 | 06/16/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| GAS | HOLD | 06/09/2025 | 06/13/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM site plan shows generator 5ft from the tanks. Revise to show 10ft. generator is an ignition source | |||
| ZON | COMPLETE | 06/09/2025 | 06/09/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 11/06/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 11/06/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 11/06/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 11/06/2025 |
| SURCHARGE FS 533.721 | ¤2.00 | 06/24/2025 |
| SURCHARGE - FS 468.631 | ¤2.00 | 06/24/2025 |
| SITE PLAN 15 | ¤15.00 | 06/24/2025 |
| ADJUSTMENT 10% | (¤12.25) | 06/24/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 06/24/2025 |
| INSPECTION - RESIDENTIAL | ¤60.00 | 06/24/2025 |
| PLAN REVIEW - MISC 32.50 | ¤32.50 | 06/24/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤289.25 |