Permit #2025060400
Permit Details
Status: COED
| Parcel Id: 07-11-31-7024-00180-0050 |
| CONDITIONED SPACE: 1873 sqft |
| GARAGE: 524 sqft |
| OPENED PORCH (WITH ROOF) : 249 sqft |
| Total Square Footage: 2646 sqft |
| Block: 00180 |
| Subdivision: - |
| Job Phone: 352-433-8382 |
| Location Address: 23 PRINCE KAAREL LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 06/25/2025 |
| NOC: RECORDED |
| Applicant name: ALFREDO E SCHEER |
| Owner: MARTINS MANUEL D & ANNA DEJESUS MARTINS TRUSTEES |
|
Address 207 LAMBERT AVE FLAGLER BEACH, FL 32136 |
| Lot: 0050 |
| Contracted Stated Job Value: ¤165,000.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
ESTELA LIVING LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
237 S. DIXIE HWY, 4TH FLOOR CORAL GABLES, FL 33133 |
CGC1534535 (Exp: 08/31/2026) | 352-433-8382 |
Sub Contractors
JOSEPH HORATIO STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PARKWAY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2026) | 877-906-1113 |
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PKWY SANFORD, FL 32771 |
CAC043953 (Exp: 08/31/2026) | 877-906-1113 |
DUSTIN L ESTEP
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2041 N HIAWASSEE RD APOPKA, FL 32703 |
CCC1330971 (Exp: 08/31/2026) | 407-702-0206 | 352-988-6629 |
JUAN CARLOS GONZALEZ
| Status | Location Address | State License Number |
| ACTIVE |
1328 COUNTY ROAD 308 CRESCENT CITY, FL 32112 |
RF11067806 (Exp: 08/31/2027) |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 06/05/2026 | FINAL APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 6/5/2026 12:38:29 PM *** Final Approved 5/5/2026 - PREVIOUS INSPECTION NOTES 5/5/26: 1). No hot water. (breaker is on). FBC-P2722.2 2). right side hose bibb is missing vacuum breaker. FBCR P2902.4.3 3). Right side guest bathroom - tub spout needs to be sealed at the wall. FBC-P2705.1(3) 4). Front entry: drip edge needs to be sealed where it enters stucco. FBC-R903.2 5). Interior dryer exhaust needs to be capped/plugged or taped. FBC-M1502.4.7 6). Primary bathroom shower drain is clogged. FBC-P2705.1(4) 7). Main meter panel identification label is painted over. NEC 110.3(B) - Installation and Use: 8). Dishwasher is unplugged due to outlet configuration and (possibly) cord length. FBC [A] 110.3(6) NOTE: please clear out lanai outlet of excessive spider nests so it can be properly tested. | |||
| BLD - BUILDING FINAL | 05/05/2026 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/5/2026 1:48:21 PM *** 5/5/26: 1). No hot water. (breaker is on). FBC-P2722.2 2). right side hose bibb is missing vacuum breaker. FBCR P2902.4.3 3). Right side guest bathroom - tub spout needs to be sealed at the wall. FBC-P2705.1(3) 4). Front entry: drip edge needs to be sealed where it enters stucco. FBC-R903.2 5). Interior dryer exhaust needs to be capped/plugged or taped. FBC-M1502.4.7 6). Primary bathroom shower drain is clogged. FBC-P2705.1(4) 7). Main meter panel identification label is painted over. NEC 110.3(B) - Installation and Use: 8). Dishwasher is unplugged due to outlet configuration and (possibly) cord length. FBC [A] 110.3(6) NOTE: please clear out lanai outlet of excessive spider nests so it can be properly tested. | |||
| ROW - STORMWATER FINAL | 05/05/2026 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 4/20/2026 - PREVIOUS INSPECTION NOTES 1) ALL DIRT AND OVER POURED CONCRETE MUST BE OUT OF CULVERT. 2) ALL BARE AREAS IN THE ADJACENT LOT IN THE BACK MUST HAVE SOD DUE TO THIS IS A IMPROVED PROPERTY. 3) LEFT SIDE IN THE ADJCENT LOT AT HOUSE #21 YOU MUST REPAIR ALL DISTURBED AREAS WITH GRADING AND SOD. SEE PHOTOS FOR REFERENCE OF AREAS. | |||
| U -UTILITY RESIDENTIAL FINAL | 04/20/2026 | FINAL APPROVED | BHAINES |
| Note: Inspector Notes from Inspection 9035 No CC, No IRR. | |||
| ROW - FINAL APRON (AFTER POUR) | 04/20/2026 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. | |||
| ROW - STORMWATER FINAL | 04/20/2026 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: 1) ALL DIRT AND OVER POURED CONCRETE MUST BE OUT OF CULVERT. 2) ALL BARE AREAS IN THE ADJACENT LOT IN THE BACK MUST HAVE SOD DUE TO THIS IS A IMPROVED PROPERTY. 3) LEFT SIDE IN THE ADJCENT LOT AT HOUSE #21 YOU MUST REPAIR ALL DISTURBED AREAS WITH GRADING AND SOD. SEE PHOTOS FOR REFERENCE OF AREAS. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/16/2026 | APPROVED - AS NOTED | FSLADISH |
| Note: 4/16/26 NEWEST UPLOADED LDAGC MEETS MINIMUM COPC STANDARDS AT THE TIME OF THIS REVIEW. BASED ON THE ENGINEER SIGNED AND SEALED LGADC MEETING THE COPC MINIMUM REQUIREMENTS AT THE TIME OF THIS INSPECTION, I AM APPROVING THIS DOCUMENT. Effective 3/25/26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certification for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types. 4/1/2026 - PREVIOUS INSPECTION NOTES ** 04/01/26 MISSED ON YOUR PREVIOUS FINAL SURVEYS: YOU DO NOT HAVE THE REQUIRED FALL WITHIN THE FIRST 10 FT OFF THE REAR OF YOUR STRUCTURE A 5% SLOPE OF 6 INCHES IN THE FIRST 10 FT. THE FINAL GRADE DOES NOT MATCH THE PROPOSED ELEVATIONS SHOWING THE REQUIRED FALL FROM STRUCTURE ** Chapter 4, R401.3- Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) ** "Final Survey. The Final Survey is used to verify compliance with the Topographic Survey, Lot Grading Plan and Swale Plan. (1) A Final Survey must be submitted in person or uploaded online. If the survey is incomplete, unclear, does not adequately show the drainage patterns, or if the constructed drainage is incorrect, it will be disapproved until corrections are made and resubmitted for review and approval. Once any required field changes have been made and the survey has been revised, the contractor shall submit one (1) signed and sealed revised survey for review. If the field changes and/or the revised survey is accepted, a final inspection may be scheduled by the contractor. Section 300.01 F(1) V-17" __________________________________________________________________________________________________________________________ 3/26/2026 - PREVIOUS INSPECTION NOTES THE FINAL SURVEY HAS NO ROADSIDE SWALE ELEVATION AND YOU STATED THAT #34 THAT THE ELEVATION IS WITHIN .10 FROM THE SWALE PLAN. YOU CAN'T SAY YES IF THERE IS NO ELEVATIONS ON SURVEY. -------------------------------------------------------------------------- 3/18/2026 - PREVIOUS INSPECTION NOTES THE FINAL SURVEY HAS NO ROADSIDE SWALE ELEVATION AND YOU STATED THAT #34 THAT THE ELEVATION IS WITHIN .10 FROM THE SWALE PLAN. YOU CAN'T SAY YES IF THERE IS NO ELEVATIONS ON SURVEY. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 04/16/2026 | CANCELLED BY INSPECTOR | FSLADISH |
| Note: 4/16/26 Effective 3/25/26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certification for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types. _____________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 4/16/26 NEWEST UPLOADED LDAGC MEETS MINIMUM COPC STANDARDS AT THE TIME OF THIS REVIEW. BASED ON THE ENGINEER SIGNED AND SEALED LGADC MEETING THE COPC MINIMUM REQUIREMENTS AT THE TIME OF THIS INSPECTION, I AM APPROVING THIS DOCUMENT. Effective 3/25/26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certification for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types. 4/1/2026 - PREVIOUS INSPECTION NOTES ** 04/01/26 MISSED ON YOUR PREVIOUS FINAL SURVEYS: YOU DO NOT HAVE THE REQUIRED FALL WITHIN THE FIRST 10 FT OFF THE REAR OF YOUR STRUCTURE A 5% SLOPE OF 6 INCHES IN THE FIRST 10 FT. THE FINAL GRADE DOES NOT MATCH THE PROPOSED ELEVATIONS SHOWING THE REQUIRED FALL FROM STRUCTURE ** Chapter 4, R401.3- Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) ** "Final Survey. The Final Survey is used to verify compliance with the Topographic Survey, Lot Grading Plan and Swale Plan. (1) A Final Survey must be submitted in person or uploaded online. If the survey is incomplete, unclear, does not adequately show the drainage patterns, or if the constructed drainage is incorrect, it will be disapproved until corrections are made and resubmitted for review and approval. Once any required field changes have been made and the survey has been revised, the contractor shall submit one (1) signed and sealed revised survey for review. If the field changes and/or the revised survey is accepted, a final inspection may be scheduled by the contractor. Section 300.01 F(1) V-17" __________________________________________________________________________________________________________________________ 3/26/2026 - PREVIOUS INSPECTION NOTES THE FINAL SURVEY HAS NO ROADSIDE SWALE ELEVATION AND YOU STATED THAT #34 THAT THE ELEVATION IS WITHIN .10 FROM THE SWALE PLAN. YOU CAN'T SAY YES IF THERE IS NO ELEVATIONS ON SURVEY. -------------------------------------------------------------------------- 3/18/2026 - PREVIOUS INSPECTION NOTES THE FINAL SURVEY HAS NO ROADSIDE SWALE ELEVATION AND YOU STATED THAT #34 THAT THE ELEVATION IS WITHIN .10 FROM THE SWALE PLAN. YOU CAN'T SAY YES IF THERE IS NO ELEVATIONS ON SURVEY. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/01/2026 | Disapproved - NO FEE | EMADISON |
| Note: ** 04/01/26 MISSED ON YOUR PREVIOUS FINAL SURVEYS: YOU DO NOT HAVE THE REQUIRED FALL WITHIN THE FIRST 10 FT OFF THE REAR OF YOUR STRUCTURE A 5% SLOPE OF 6 INCHES IN THE FIRST 10 FT. THE FINAL GRADE DOES NOT MATCH THE PROPOSED ELEVATIONS SHOWING THE REQUIRED FALL FROM STRUCTURE ** Chapter 4, R401.3- Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) ** "Final Survey. The Final Survey is used to verify compliance with the Topographic Survey, Lot Grading Plan and Swale Plan. (1) A Final Survey must be submitted in person or uploaded online. If the survey is incomplete, unclear, does not adequately show the drainage patterns, or if the constructed drainage is incorrect, it will be disapproved until corrections are made and resubmitted for review and approval. Once any required field changes have been made and the survey has been revised, the contractor shall submit one (1) signed and sealed revised survey for review. If the field changes and/or the revised survey is accepted, a final inspection may be scheduled by the contractor. Section 300.01 F(1) V-17" __________________________________________________________________________________________________________________________ 3/26/2026 - PREVIOUS INSPECTION NOTES THE FINAL SURVEY HAS NO ROADSIDE SWALE ELEVATION AND YOU STATED THAT #34 THAT THE ELEVATION IS WITHIN .10 FROM THE SWALE PLAN. YOU CAN'T SAY YES IF THERE IS NO ELEVATIONS ON SURVEY. -------------------------------------------------------------------------- 3/18/2026 - PREVIOUS INSPECTION NOTES THE FINAL SURVEY HAS NO ROADSIDE SWALE ELEVATION AND YOU STATED THAT #34 THAT THE ELEVATION IS WITHIN .10 FROM THE SWALE PLAN. YOU CAN'T SAY YES IF THERE IS NO ELEVATIONS ON SURVEY. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 03/26/2026 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: THE FINAL SURVEY HAS NO ROADSIDE SWALE ELEVATION AND YOU STATED THAT #34 THAT THE ELEVATION IS WITHIN .10 FROM THE SWALE PLAN. YOU CAN'T SAY YES IF THERE IS NO ELEVATIONS ON SURVEY. -------------------------------------------------------------------------- 3/18/2026 - PREVIOUS INSPECTION NOTES THE FINAL SURVEY HAS NO ROADSIDE SWALE ELEVATION AND YOU STATED THAT #34 THAT THE ELEVATION IS WITHIN .10 FROM THE SWALE PLAN. YOU CAN'T SAY YES IF THERE IS NO ELEVATIONS ON SURVEY. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 03/18/2026 | Disapproved - NO FEE | PFLANAGAN |
| Note: THE FINAL SURVEY HAS NO ROADSIDE SWALE ELEVATION AND YOU STATED THAT #34 THAT THE ELEVATION IS WITHIN .10 FROM THE SWALE PLAN. YOU CAN'T SAY YES IF THERE IS NO ELEVATIONS ON SURVEY. | |||
| U-CROSS CONNECTION | 02/20/2026 | APPROVED - AS NOTED | BHAINES |
| Note: No CC, No IRR. | |||
| ROW- PRE-APRON (PRE-POUR) | 02/04/2026 | APPROVED - AS NOTED | EMADISON |
| Note: ** 02/04/26 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builder’s responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. ** BUILDERS RESPONSIBILITY TO ENSURE CULVERT ELEVATION IS WITHIN TOLERANCE BEFORE THE POUR IN THE EVENT OF RAIN CHECK COMPACTION OF MATERIAL **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300, E RESIDENTIAL CULVERT DETAIL _______________________________________________________________________________________________________________________ 2/2/2026 - PREVIOUS INSPECTION NOTES 2/2/26 YOU DO NOT HAVE YOUR REQUIRED MINIMUM 24" #4 REBAR ON SITE. YOU DO NOT HAVE THE REQUIRED 6" DEPTH FOR YOU MITERED END FOOTERS ON BOTH SIDES AT THE TIME OF THIS INSPECTION.. ___________________________________________________________________________________________________________________________________ 1/30/2026 - PREVIOUS INSPECTION NOTES 1/30/26 RECEIVED TEXT FROM DOUG CM TO PLEASE CANCEL THIS PREPOUR INSPECTION. | |||
| ROW- PRE-APRON (PRE-POUR) | 02/02/2026 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 2/2/26 YOU DO NOT HAVE YOUR REQUIRED MINIMUM 24" #4 REBAR ON SITE. YOU DO NOT HAVE THE REQUIRED 6" DEPTH FOR YOU MITERED END FOOTERS ON BOTH SIDES AT THE TIME OF THIS INSPECTION.. ___________________________________________________________________________________________________________________________________ 1/30/2026 - PREVIOUS INSPECTION NOTES 1/30/26 RECEIVED TEXT FROM DOUG CM TO PLEASE CANCEL THIS PREPOUR INSPECTION. | |||
| ROW- PRE-APRON (PRE-POUR) | 01/30/2026 | CANCELLED BY APPLICANT | FSLADISH |
| Note: 1/30/26 RECEIVED TEXT FROM DOUG CM TO PLEASE CANCEL THIS PREPOUR INSPECTION. | |||
| GRAVITY SEWER TEST | 01/21/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 1/21/2026 11:49:02 AM *** Inspector Notes from Inspection 2060 SILT FENCE NEEDS TO EXTEND ACCROSS THE FRONT OF PROPERTY, WATER SERVICE NOT RAN YET | |||
| SEWER TIE IN | 01/21/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 1/21/2026 11:49:13 AM *** Inspector Notes from Inspection 2060 SILT FENCE NEEDS TO EXTEND ACCROSS THE FRONT OF PROPERTY, WATER SERVICE NOT RAN YET | |||
| ELECTRIC - EARLY POWER | 12/09/2025 | APPROVED - AS NOTED | MKRASKI |
| Note: Emailed FPL @ 10:15am | |||
| INSULATION | 11/05/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/5/2025 9:47:38 AM *** 11/3/2025 - PREVIOUS INSPECTION NOTES 11/3/25: 1). Firestop missing at horizontal area between stud wall and breaker panel pack out. FS written below. FBC-R302.11) 2). Incomplete firestop at dryer exhaust top plate penetration. FBC-R302.11 3). FIRE-BLOCKING missing at top plate cutout in Pantry. Marked FB below area. FBC-R302.11 Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 10/31/2025 2:03:46 PM *** 10/31/25: FPA revision is only accepted as of today's date. This will need to be approved prior to Insulation Inspection. 10/22/2025 - PREVIOUS INSPECTION NOTES 10/22/25: Previously noted items 4, 5, 6 and 7 are not fully resolved. 4). FPA number listed does not match the installed door. FBC-[A] 107.4 5). SGD only the frame is installed so FPA number cannot be verified for installation. FBC-[A] 107.4 > >>> No Product approval sticker on door or frame. Installation cannot be verified. Installation does not match the FPA number shown on the updated Florida Product Approval page submitted to the City. 6). Slab Penetration: Bathtub > Slab at bathtub drain needs to be fully repaired with a cement type product as required for termite protection (FBC-P2603.3.1) and to meet original & minimum slab depth ( FBC [A]107.4 / FBC R506.1). 7). Bathroom exhaust fans are not wired up as required. FBC-[A] 107.4 Also, they are missing mechanical fastner (strap). FBC-M1502.4.2 refers to FBC-M1601.4.1 - Duct connections to flanges of air distribution system equipment shall be sealed and mechanically fastened. 10/14/2025 - PREVIOUS INSPECTION NOTES 10/14/25: 1). No water pressure. FBCR P2503.7 2). No 5ft head pressure. FBC-P2503.5.1 3). Service feed > plan shows 150amp service and requires 2/0 Copper or 4/0 Aluminum. 2/0 Aluminum is installed. Will require a engineer's revision for plan requirements to meet installation. FBC [A]107.4 4). Front entry door requires solid blocking and anchors at the top jamb. FPA number listed does not match the installed door. FBC-[A] 107.4 5). SGD only the frame is installed so FPA number cannot be verified for installation. FBC-[A] 107.4 6). Slab Penetration: Bathtub > Slab at bathtub drain needs to be fully repaired with a cement type product as required for termite protection (FBC-P2603.3.1) and to meet original & minimum slab depth ( FBC [A]107.4 / FBC R506.1). 7). Bathroom exhaust fans are not wired up as required. FBC-[A] 107.4 Also, they are missing mechanical fastner (strap). FBC-M1502.4.2 | |||
| INSULATION | 11/03/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/3/2025 9:57:47 AM *** 11/3/25: 1). Firestop missing at horizontal area between stud wall and breaker panel pack out. FS written below. FBC-R302.11) 2). Incomplete firestop at dryer exhaust top plate penetration. FBC-R302.11 3). FIRE-BLOCKING missing at top plate cutout in Pantry. Marked FB below area. FBC-R302.11 Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 10/31/2025 2:03:46 PM *** 10/31/25: FPA revision is only accepted as of today's date. This will need to be approved prior to Insulation Inspection. 10/22/2025 - PREVIOUS INSPECTION NOTES 10/22/25: Previously noted items 4, 5, 6 and 7 are not fully resolved. 4). FPA number listed does not match the installed door. FBC-[A] 107.4 5). SGD only the frame is installed so FPA number cannot be verified for installation. FBC-[A] 107.4 > >>> No Product approval sticker on door or frame. Installation cannot be verified. Installation does not match the FPA number shown on the updated Florida Product Approval page submitted to the City. 6). Slab Penetration: Bathtub > Slab at bathtub drain needs to be fully repaired with a cement type product as required for termite protection (FBC-P2603.3.1) and to meet original & minimum slab depth ( FBC [A]107.4 / FBC R506.1). 7). Bathroom exhaust fans are not wired up as required. FBC-[A] 107.4 Also, they are missing mechanical fastner (strap). FBC-M1502.4.2 refers to FBC-M1601.4.1 - Duct connections to flanges of air distribution system equipment shall be sealed and mechanically fastened. 10/14/2025 - PREVIOUS INSPECTION NOTES 10/14/25: 1). No water pressure. FBCR P2503.7 2). No 5ft head pressure. FBC-P2503.5.1 3). Service feed > plan shows 150amp service and requires 2/0 Copper or 4/0 Aluminum. 2/0 Aluminum is installed. Will require a engineer's revision for plan requirements to meet installation. FBC [A]107.4 4). Front entry door requires solid blocking and anchors at the top jamb. FPA number listed does not match the installed door. FBC-[A] 107.4 5). SGD only the frame is installed so FPA number cannot be verified for installation. FBC-[A] 107.4 6). Slab Penetration: Bathtub > Slab at bathtub drain needs to be fully repaired with a cement type product as required for termite protection (FBC-P2603.3.1) and to meet original & minimum slab depth ( FBC [A]107.4 / FBC R506.1). 7). Bathroom exhaust fans are not wired up as required. FBC-[A] 107.4 Also, they are missing mechanical fastner (strap). FBC-M1502.4.2 | |||
| ALL ROUGH | 10/31/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 10/31/2025 2:03:46 PM *** 10/31/25: FPA revision is only accepted as of today's date. This will need to be approved prior to Insulation Inspection. 10/22/2025 - PREVIOUS INSPECTION NOTES 10/22/25: Previously noted items 4, 5, 6 and 7 are not fully resolved. 4). FPA number listed does not match the installed door. FBC-[A] 107.4 5). SGD only the frame is installed so FPA number cannot be verified for installation. FBC-[A] 107.4 > >>> No Product approval sticker on door or frame. Installation cannot be verified. Installation does not match the FPA number shown on the updated Florida Product Approval page submitted to the City. 6). Slab Penetration: Bathtub > Slab at bathtub drain needs to be fully repaired with a cement type product as required for termite protection (FBC-P2603.3.1) and to meet original & minimum slab depth ( FBC [A]107.4 / FBC R506.1). 7). Bathroom exhaust fans are not wired up as required. FBC-[A] 107.4 Also, they are missing mechanical fastner (strap). FBC-M1502.4.2 refers to FBC-M1601.4.1 - Duct connections to flanges of air distribution system equipment shall be sealed and mechanically fastened. 10/14/2025 - PREVIOUS INSPECTION NOTES 10/14/25: 1). No water pressure. FBCR P2503.7 2). No 5ft head pressure. FBC-P2503.5.1 3). Service feed > plan shows 150amp service and requires 2/0 Copper or 4/0 Aluminum. 2/0 Aluminum is installed. Will require a engineer's revision for plan requirements to meet installation. FBC [A]107.4 4). Front entry door requires solid blocking and anchors at the top jamb. FPA number listed does not match the installed door. FBC-[A] 107.4 5). SGD only the frame is installed so FPA number cannot be verified for installation. FBC-[A] 107.4 6). Slab Penetration: Bathtub > Slab at bathtub drain needs to be fully repaired with a cement type product as required for termite protection (FBC-P2603.3.1) and to meet original & minimum slab depth ( FBC [A]107.4 / FBC R506.1). 7). Bathroom exhaust fans are not wired up as required. FBC-[A] 107.4 Also, they are missing mechanical fastner (strap). FBC-M1502.4.2 | |||
| LATH/BRICK/ WATER BARRIER | 10/22/2025 | APPROVED | RSIMS |
| Note: 10/15/2025 - PREVIOUS INSPECTION NOTES 10/15/25: 1). Right side of house: CMU and footer cut out for plumbing supply needs to be repaired with cement type product as required. (Also, wire lath fell off and is not sufficient for the repair). FBC-[A] 107.4 | |||
| ALL ROUGH | 10/22/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 10/22/2025 1:37:47 PM *** 10/22/25: Previously noted items 4, 5, 6 and 7 are not fully resolved. 4). FPA number listed does not match the installed door. FBC-[A] 107.4 5). SGD only the frame is installed so FPA number cannot be verified for installation. FBC-[A] 107.4 > >>> No Product approval sticker on door or frame. Installation cannot be verified. Installation does not match the FPA number shown on the updated Florida Product Approval page submitted to the City. 6). Slab Penetration: Bathtub > Slab at bathtub drain needs to be fully repaired with a cement type product as required for termite protection (FBC-P2603.3.1) and to meet original & minimum slab depth ( FBC [A]107.4 / FBC R506.1). 7). Bathroom exhaust fans are not wired up as required. FBC-[A] 107.4 Also, they are missing mechanical fastner (strap). FBC-M1502.4.2 refers to FBC-M1601.4.1 - Duct connections to flanges of air distribution system equipment shall be sealed and mechanically fastened. 10/14/2025 - PREVIOUS INSPECTION NOTES 10/14/25: 1). No water pressure. FBCR P2503.7 2). No 5ft head pressure. FBC-P2503.5.1 3). Service feed > plan shows 150amp service and requires 2/0 Copper or 4/0 Aluminum. 2/0 Aluminum is installed. Will require a engineer's revision for plan requirements to meet installation. FBC [A]107.4 4). Front entry door requires solid blocking and anchors at the top jamb. FPA number listed does not match the installed door. FBC-[A] 107.4 5). SGD only the frame is installed so FPA number cannot be verified for installation. FBC-[A] 107.4 6). Slab Penetration: Bathtub > Slab at bathtub drain needs to be fully repaired with a cement type product as required for termite protection (FBC-P2603.3.1) and to meet original & minimum slab depth ( FBC [A]107.4 / FBC R506.1). 7). Bathroom exhaust fans are not wired up as required. FBC-[A] 107.4 Also, they are missing mechanical fastner (strap). FBC-M1502.4.2 | |||
| LATH/BRICK/ WATER BARRIER | 10/15/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 10/15/2025 10:41:06 AM *** 10/15/25: 1). Right side of house: CMU and footer cut out for plumbing supply needs to be repaired with cement type product as required. (Also, wire lath fell off and is not sufficient for the repair). FBC-[A] 107.4 | |||
| ALL ROUGH | 10/14/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 10/14/2025 2:06:41 PM *** 10/14/25: 1). No water pressure. FBCR P2503.7 2). No 5ft head pressure. FBC-P2503.5.1 3). Service feed > plan shows 150amp service and requires 2/0 Copper or 4/0 Aluminum. 2/0 Aluminum is installed. Will require a engineer's revision for plan requirements to meet installation. FBC [A]107.4 4). Front entry door requires solid blocking and anchors at the top jamb. FPA number listed does not match the installed door. FBC-[A] 107.4 5). SGD only the frame is installed so FPA number cannot be verified for installation. FBC-[A] 107.4 6). Slab Penetration: Bathtub > Slab at bathtub drain needs to be fully repaired with a cement type product as required for termite protection (FBC-P2603.3.1) and to meet original & minimum slab depth ( FBC [A]107.4 / FBC R506.1). 7). Bathroom exhaust fans are not wired up as required. FBC-[A] 107.4 Also, they are missing mechanical fastner (strap). FBC-M1502.4.2 | |||
| WALL SHEATHING | 10/09/2025 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 10/9/25 Previous note needs to be addressed before any inspection can be passed. Culvert been noted since slab inspection (9/16/25) 4). Silt fence needs repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale, and safe job site access. FBC 3307.1 / FBC 3303.5 --Inspection itself was good, but not passed due to above note-- 10/8/2025 - PREVIOUS INSPECTION NOTES 10/8/25 Previous note needs to be addressed before any inspection can be passed. Culvert been noted since slab inspection (9/16/25) 4). Silt fence needs repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale, and safe job site access. FBC 3307.1 / FBC 3303.5 --Inspection itself was good, but not passed due to above note-- | |||
| WALL SHEATHING | 10/09/2025 | APPROVED | MCONTRYMAN |
| Note: 10/9/2025 - PREVIOUS INSPECTION NOTES 10/9/25 Previous note needs to be addressed before any inspection can be passed. Culvert been noted since slab inspection (9/16/25) 4). Silt fence needs repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale, and safe job site access. FBC 3307.1 / FBC 3303.5 --Inspection itself was good, but not passed due to above note-- 10/8/2025 - PREVIOUS INSPECTION NOTES 10/8/25 Previous note needs to be addressed before any inspection can be passed. Culvert been noted since slab inspection (9/16/25) 4). Silt fence needs repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale, and safe job site access. FBC 3307.1 / FBC 3303.5 --Inspection itself was good, but not passed due to above note-- | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 10/09/2025 | Disapproved -FEE REQUIRED | MCONTRYMAN |
| Note: 10/9/25 Previous note needs to be addressed before any inspection can be passed. Culvert been noted since slab inspection (9/16/25) 4). Silt fence needs repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale, and safe job site access. FBC 3307.1 / FBC 3303.5 --Inspection itself was good, but not passed due to above note-- 10/8/2025 - PREVIOUS INSPECTION NOTES 10/8/25 Previous note needs to be addressed before any inspection can be passed. Culvert been noted since slab inspection (9/16/25) 4). Silt fence needs repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale, and safe job site access. FBC 3307.1 / FBC 3303.5 --Inspection itself was good, but not passed due to above note-- 10/2/2025 - PREVIOUS INSPECTION NOTES 10/2/25: Incomplete Inspection due to extremely damaged plans in permit box. 1). Permit box needs attention. Please replace damaged plans with new approved plans including Truss packet. FBC [A]107.3.1 2). Miscellaneous trusses missing shim/barrier between truss and CMU wall. Most spots orange paint line below. Builder to check all. FBC-R317.1 and on plans. FBC [A]107.4 3). Front entry straps/anchors are not visable above plywood overvalley section. Could not check. FBC[A]110.1 4). Swale area needs to be cleaned up, Silt fence repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale. FBC 3307.1 / FBC 3303.5 5). Please empty overflowing dumpster and have excess debris/trash cleaned up to make site safe for inspections. FBC-[A] 101.3 6). Roof sheathing bump checked. Garage has an area of roof sheathing that is damaged and requires replacement/repair. Marked on wall below. FBC [A]107.4 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 9/18/2025 1:57:31 PM *** 9/18/25: Previously listed item 2 remains un resolved. This will need to be resolved before any other inspections will be approved. 2). Silt fence still needs to be repaired at the back as previously noted (along with the front areas now). FBC 3307.1. Also, swale area needs to be clear to allow water to flow freely through the swale as required. FBC 3303.5. (currently has standing water due to condition of swale area). ***** NOTE: Trusses have been placed directly on the dirt which is not in compliance with Truss manufacturer's requirements for placement. May require a moisture test and/or engineer's letter for repair of any damaged trusses. 9/16/2025 - PREVIOUS INSPECTION NOTES 9/16/25: 1). Right side of front entry: Dowel / down rods do not meet the minimum clearance (2" from face of block and/or 3/4: from inside of block) as required. (FBC-R606.3.4) Spray painted orange. 2). Silt fence still needs to be repaired at the back as previously noted (along with the front areas now). FBC 3307.1 NOTE: a temporary culvert pipe will be required to allow free flow of water through the swale as required. FBC 3303.5. (currently has standing water due to condition of swale area). Also: Trusses have been placed directly on the dirt which is not in compliance with Truss manufacturer's requirements for placement. May require a moisture test and/or engineer's letter for repair of any damaged trusses. Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 9/2/2025 11:07:38 AM *** 9/2/25: 1). Silt fence needs to be repaired at the back. FBC 3307.1 Must be complete prior to next inspection. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 10/09/2025 | APPROVED | MCONTRYMAN |
| Note: 10/9/2025 - PREVIOUS INSPECTION NOTES 10/9/25 Previous note needs to be addressed before any inspection can be passed. Culvert been noted since slab inspection (9/16/25) 4). Silt fence needs repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale, and safe job site access. FBC 3307.1 / FBC 3303.5 --Inspection itself was good, but not passed due to above note-- 10/8/2025 - PREVIOUS INSPECTION NOTES 10/8/25 Previous note needs to be addressed before any inspection can be passed. Culvert been noted since slab inspection (9/16/25) 4). Silt fence needs repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale, and safe job site access. FBC 3307.1 / FBC 3303.5 --Inspection itself was good, but not passed due to above note-- 10/2/2025 - PREVIOUS INSPECTION NOTES 10/2/25: Incomplete Inspection due to extremely damaged plans in permit box. 1). Permit box needs attention. Please replace damaged plans with new approved plans including Truss packet. FBC [A]107.3.1 2). Miscellaneous trusses missing shim/barrier between truss and CMU wall. Most spots orange paint line below. Builder to check all. FBC-R317.1 and on plans. FBC [A]107.4 3). Front entry straps/anchors are not visable above plywood overvalley section. Could not check. FBC[A]110.1 4). Swale area needs to be cleaned up, Silt fence repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale. FBC 3307.1 / FBC 3303.5 5). Please empty overflowing dumpster and have excess debris/trash cleaned up to make site safe for inspections. FBC-[A] 101.3 6). Roof sheathing bump checked. Garage has an area of roof sheathing that is damaged and requires replacement/repair. Marked on wall below. FBC [A]107.4 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 9/18/2025 1:57:31 PM *** 9/18/25: Previously listed item 2 remains un resolved. This will need to be resolved before any other inspections will be approved. 2). Silt fence still needs to be repaired at the back as previously noted (along with the front areas now). FBC 3307.1. Also, swale area needs to be clear to allow water to flow freely through the swale as required. FBC 3303.5. (currently has standing water due to condition of swale area). ***** NOTE: Trusses have been placed directly on the dirt which is not in compliance with Truss manufacturer's requirements for placement. May require a moisture test and/or engineer's letter for repair of any damaged trusses. 9/16/2025 - PREVIOUS INSPECTION NOTES 9/16/25: 1). Right side of front entry: Dowel / down rods do not meet the minimum clearance (2" from face of block and/or 3/4: from inside of block) as required. (FBC-R606.3.4) Spray painted orange. 2). Silt fence still needs to be repaired at the back as previously noted (along with the front areas now). FBC 3307.1 NOTE: a temporary culvert pipe will be required to allow free flow of water through the swale as required. FBC 3303.5. (currently has standing water due to condition of swale area). Also: Trusses have been placed directly on the dirt which is not in compliance with Truss manufacturer's requirements for placement. May require a moisture test and/or engineer's letter for repair of any damaged trusses. Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 9/2/2025 11:07:38 AM *** 9/2/25: 1). Silt fence needs to be repaired at the back. FBC 3307.1 Must be complete prior to next inspection. | |||
| ROOF VALLEY & METAL | 10/09/2025 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 10/9/25 Previous note needs to be addressed before any inspection can be passed. Culvert been noted since slab inspection (9/16/25) 4). Silt fence needs repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale, and safe job site access. FBC 3307.1 / FBC 3303.5 --Inspection itself was good, but not passed due to above note-- 10/8/2025 - PREVIOUS INSPECTION NOTES 10/8/25 Previous note needs to be addressed before any inspection can be passed. Culvert been noted since slab inspection (9/16/25) 4). Silt fence needs repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale, and safe job site access. FBC 3307.1 / FBC 3303.5 --Inspection itself was good, but not passed due to above note-- New inspection due to canceled inspection 10/3/2025 - PREVIOUS INSPECTION NOTES 10/3/25: Must have an approved inspection 2460 or 2465 prior to this inspection. | |||
| ROOF VALLEY & METAL | 10/09/2025 | APPROVED | MCONTRYMAN |
| Note: 10/9/2025 - PREVIOUS INSPECTION NOTES 10/9/25 Previous note needs to be addressed before any inspection can be passed. Culvert been noted since slab inspection (9/16/25) 4). Silt fence needs repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale, and safe job site access. FBC 3307.1 / FBC 3303.5 --Inspection itself was good, but not passed due to above note-- 10/8/2025 - PREVIOUS INSPECTION NOTES 10/8/25 Previous note needs to be addressed before any inspection can be passed. Culvert been noted since slab inspection (9/16/25) 4). Silt fence needs repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale, and safe job site access. FBC 3307.1 / FBC 3303.5 --Inspection itself was good, but not passed due to above note-- New inspection due to canceled inspection 10/3/2025 - PREVIOUS INSPECTION NOTES 10/3/25: Must have an approved inspection 2460 or 2465 prior to this inspection. | |||
| ROOF VALLEY & METAL | 10/08/2025 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 10/8/25 Previous note needs to be addressed before any inspection can be passed. Culvert been noted since slab inspection (9/16/25) 4). Silt fence needs repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale, and safe job site access. FBC 3307.1 / FBC 3303.5 --Inspection itself was good, but not passed due to above note-- New inspection due to canceled inspection 10/3/2025 - PREVIOUS INSPECTION NOTES 10/3/25: Must have an approved inspection 2460 or 2465 prior to this inspection. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 10/08/2025 | Disapproved -FEE REQUIRED | MCONTRYMAN |
| Note: 10/8/25 Previous note needs to be addressed before any inspection can be passed. Culvert been noted since slab inspection (9/16/25) 4). Silt fence needs repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale, and safe job site access. FBC 3307.1 / FBC 3303.5 --Inspection itself was good, but not passed due to above note-- 10/2/2025 - PREVIOUS INSPECTION NOTES 10/2/25: Incomplete Inspection due to extremely damaged plans in permit box. 1). Permit box needs attention. Please replace damaged plans with new approved plans including Truss packet. FBC [A]107.3.1 2). Miscellaneous trusses missing shim/barrier between truss and CMU wall. Most spots orange paint line below. Builder to check all. FBC-R317.1 and on plans. FBC [A]107.4 3). Front entry straps/anchors are not visable above plywood overvalley section. Could not check. FBC[A]110.1 4). Swale area needs to be cleaned up, Silt fence repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale. FBC 3307.1 / FBC 3303.5 5). Please empty overflowing dumpster and have excess debris/trash cleaned up to make site safe for inspections. FBC-[A] 101.3 6). Roof sheathing bump checked. Garage has an area of roof sheathing that is damaged and requires replacement/repair. Marked on wall below. FBC [A]107.4 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 9/18/2025 1:57:31 PM *** 9/18/25: Previously listed item 2 remains un resolved. This will need to be resolved before any other inspections will be approved. 2). Silt fence still needs to be repaired at the back as previously noted (along with the front areas now). FBC 3307.1. Also, swale area needs to be clear to allow water to flow freely through the swale as required. FBC 3303.5. (currently has standing water due to condition of swale area). ***** NOTE: Trusses have been placed directly on the dirt which is not in compliance with Truss manufacturer's requirements for placement. May require a moisture test and/or engineer's letter for repair of any damaged trusses. 9/16/2025 - PREVIOUS INSPECTION NOTES 9/16/25: 1). Right side of front entry: Dowel / down rods do not meet the minimum clearance (2" from face of block and/or 3/4: from inside of block) as required. (FBC-R606.3.4) Spray painted orange. 2). Silt fence still needs to be repaired at the back as previously noted (along with the front areas now). FBC 3307.1 NOTE: a temporary culvert pipe will be required to allow free flow of water through the swale as required. FBC 3303.5. (currently has standing water due to condition of swale area). Also: Trusses have been placed directly on the dirt which is not in compliance with Truss manufacturer's requirements for placement. May require a moisture test and/or engineer's letter for repair of any damaged trusses. Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 9/2/2025 11:07:38 AM *** 9/2/25: 1). Silt fence needs to be repaired at the back. FBC 3307.1 Must be complete prior to next inspection. | |||
| WALL SHEATHING | 10/08/2025 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 10/8/25 Previous note needs to be addressed before any inspection can be passed. Culvert been noted since slab inspection (9/16/25) 4). Silt fence needs repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale, and safe job site access. FBC 3307.1 / FBC 3303.5 --Inspection itself was good, but not passed due to above note-- | |||
| ROOF VALLEY & METAL | 10/06/2025 | CANCELLED BY APPLICANT | WEB |
| Note: 10/3/2025 - PREVIOUS INSPECTION NOTES 10/3/25: Must have an approved inspection 2460 or 2465 prior to this inspection. | |||
| ROOF VALLEY & METAL | 10/03/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 10/3/2025 8:09:03 AM *** 10/3/25: Must have an approved inspection 2460 or 2465 prior to this inspection. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 10/02/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 10/2/2025 1:28:57 PM *** 10/2/25: Incomplete Inspection due to extremely damaged plans in permit box. 1). Permit box needs attention. Please replace damaged plans with new approved plans including Truss packet. FBC [A]107.3.1 2). Miscellaneous trusses missing shim/barrier between truss and CMU wall. Most spots orange paint line below. Builder to check all. FBC-R317.1 and on plans. FBC [A]107.4 3). Front entry straps/anchors are not visable above plywood overvalley section. Could not check. FBC[A]110.1 4). Swale area needs to be cleaned up, Silt fence repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale. FBC 3307.1 / FBC 3303.5 5). Please empty overflowing dumpster and have excess debris/trash cleaned up to make site safe for inspections. FBC-[A] 101.3 6). Roof sheathing bump checked. Garage has an area of roof sheathing that is damaged and requires replacement/repair. Marked on wall below. FBC [A]107.4 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 9/18/2025 1:57:31 PM *** 9/18/25: Previously listed item 2 remains un resolved. This will need to be resolved before any other inspections will be approved. 2). Silt fence still needs to be repaired at the back as previously noted (along with the front areas now). FBC 3307.1. Also, swale area needs to be clear to allow water to flow freely through the swale as required. FBC 3303.5. (currently has standing water due to condition of swale area). ***** NOTE: Trusses have been placed directly on the dirt which is not in compliance with Truss manufacturer's requirements for placement. May require a moisture test and/or engineer's letter for repair of any damaged trusses. 9/16/2025 - PREVIOUS INSPECTION NOTES 9/16/25: 1). Right side of front entry: Dowel / down rods do not meet the minimum clearance (2" from face of block and/or 3/4: from inside of block) as required. (FBC-R606.3.4) Spray painted orange. 2). Silt fence still needs to be repaired at the back as previously noted (along with the front areas now). FBC 3307.1 NOTE: a temporary culvert pipe will be required to allow free flow of water through the swale as required. FBC 3303.5. (currently has standing water due to condition of swale area). Also: Trusses have been placed directly on the dirt which is not in compliance with Truss manufacturer's requirements for placement. May require a moisture test and/or engineer's letter for repair of any damaged trusses. Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 9/2/2025 11:07:38 AM *** 9/2/25: 1). Silt fence needs to be repaired at the back. FBC 3307.1 Must be complete prior to next inspection. | |||
| TIE BEAM / LINTEL | 09/18/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 9/18/2025 1:57:31 PM *** 9/18/25: Previously listed item 2 remains un resolved. This will need to be resolved before any other inspections will be approved. 2). Silt fence still needs to be repaired at the back as previously noted (along with the front areas now). FBC 3307.1. Also, swale area needs to be clear to allow water to flow freely through the swale as required. FBC 3303.5. (currently has standing water due to condition of swale area). ***** NOTE: Trusses have been placed directly on the dirt which is not in compliance with Truss manufacturer's requirements for placement. May require a moisture test and/or engineer's letter for repair of any damaged trusses. 9/16/2025 - PREVIOUS INSPECTION NOTES 9/16/25: 1). Right side of front entry: Dowel / down rods do not meet the minimum clearance (2" from face of block and/or 3/4: from inside of block) as required. (FBC-R606.3.4) Spray painted orange. 2). Silt fence still needs to be repaired at the back as previously noted (along with the front areas now). FBC 3307.1 NOTE: a temporary culvert pipe will be required to allow free flow of water through the swale as required. FBC 3303.5. (currently has standing water due to condition of swale area). Also: Trusses have been placed directly on the dirt which is not in compliance with Truss manufacturer's requirements for placement. May require a moisture test and/or engineer's letter for repair of any damaged trusses. Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 9/2/2025 11:07:38 AM *** 9/2/25: 1). Silt fence needs to be repaired at the back. FBC 3307.1 Must be complete prior to next inspection. | |||
| TIE BEAM / LINTEL | 09/16/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 9/16/2025 9:40:00 AM *** 9/16/25: 1). Right side of front entry: Dowel / down rods do not meet the minimum clearance (2" from face of block and/or 3/4: from inside of block) as required. (FBC-R606.3.4) Spray painted orange. 2). Silt fence still needs to be repaired at the back as previously noted (along with the front areas now). FBC 3307.1 NOTE: a temporary culvert pipe will be required to allow free flow of water through the swale as required. FBC 3303.5. (currently has standing water due to condition of swale area). Also: Trusses have been placed directly on the dirt which is not in compliance with Truss manufacturer's requirements for placement. May require a moisture test and/or engineer's letter for repair of any damaged trusses. Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 9/2/2025 11:07:38 AM *** 9/2/25: 1). Silt fence needs to be repaired at the back. FBC 3307.1 Must be complete prior to next inspection. | |||
| MONOLITHIC SLAB | 09/02/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 9/2/2025 11:07:38 AM *** 9/2/25: 1). Silt fence needs to be repaired at the back. FBC 3307.1 Must be complete prior to next inspection. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 08/28/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: SILT FENCE NEEDS TO EXTEND ACCROSS THE FRONT OF PROPERTY, WATER SERVICE NOT RAN YET | |||
| FORMBOARD SURVEY (OFFICE USE ONLY) | 08/27/2025 | APPROVED | PFLANAGAN |
| WATER METER INSTALLATION REQUEST | 08/19/2025 | APPROVED | CBOWERMASTER |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 08/18/2025 | APPROVED | PKNAPIK |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 10/28/2025 | 10/31/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 10/20/2025 | 10/23/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 10/06/2025 | 10/08/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 08/26/2025 | 08/27/2025 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/26/2025 | 08/27/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 08/22/2025 | 08/25/2025 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Formboard FFE shall be to the nearest 0.01. Please submit revised formboard survey. | |||
| ZON | COMPLETE | 08/22/2025 | 08/22/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 08/13/2025 | 08/18/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | HOLD | 08/11/2025 | 08/12/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Provide initial Geotech report | |||
| SW1 | COMPLETE | 06/20/2025 | 06/25/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 06/20/2025 | 06/23/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 06/20/2025 | 06/20/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 06/17/2025 | 06/18/2025 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Previous comments still not addresses: Proposed flow lines shall be lower than elevations along the front property line. This ensures water is contained to the yard drainage swale. Please revise so the flow line at the front right of the property meet COPC requirements. Please feel free to call or email if there are any questions or concerns. | |||
| ENGIN1 | COMPLETE | 06/17/2025 | 06/18/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 06/17/2025 | 06/17/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 06/10/2025 | 06/25/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 06/09/2025 | 06/13/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 06/09/2025 | 06/13/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 06/09/2025 | 06/12/2025 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 06/09/2025 | 06/16/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 06/09/2025 | 06/10/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 06/09/2025 | 06/12/2025 |
| LOCATE | COMPLETE | 06/09/2025 | 06/11/2025 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 06/09/2025 | 06/12/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 06/09/2025 | 06/16/2025 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Proposed flow lines at the front of the property are higher than the front property line elevations. Please revise. | |||
| ZON | COMPLETE | 06/09/2025 | 06/10/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| RSI REINSPECTION 1 | ¤35.00 | 05/15/2026 |
| RSI REINSPECTION 1 | ¤35.00 | 05/15/2026 |
| RSI REINSPECTION 1 | ¤35.00 | 05/15/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/15/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/15/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/15/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/15/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/15/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/15/2026 |
| FC IMPACT FEE EMS | ¤62.00 | 06/25/2025 |
| IMPACT FEE FIRE | ¤434.51 | 06/25/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 06/25/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 06/25/2025 |
| IMPACT FEE PARKS | ¤1,828.01 | 06/25/2025 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 06/25/2025 |
| IMPACT FEE TRANSPORTATION | ¤1,916.00 | 06/25/2025 |
| WATER- TURN ON | ¤50.00 | 06/25/2025 |
| ADJUSTMENT 10% | (¤131.49) | 06/25/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 06/25/2025 |
| INSPECTION - RESIDENTIAL | ¤1,001.00 | 06/25/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤283.92 | 06/25/2025 |
| WASTEWATER MAIN EXTENSION IMPA | ¤2,385.00 | 06/25/2025 |
| SURCHARGE FS 533.721 | ¤11.83 | 06/25/2025 |
| SURCHARGE - FS 468.631 | ¤17.75 | 06/25/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 06/25/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 06/25/2025 |
| SW ENG PRE APRON | ¤30.00 | 06/25/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 06/25/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 06/25/2025 |
| WATER METER W/ TAP | ¤2,326.93 | 06/25/2025 |
| SEWER CREDIT | (¤1,147.00) | 06/25/2025 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 06/25/2025 |
| WASTEWATER PERM REVIEW | ¤25.00 | 06/25/2025 |
| SEWER CAPITAL FACILITY | ¤4,415.00 | 06/25/2025 |
| WATER CAPITAL FACILITY FEE | ¤3,790.49 | 06/25/2025 |
| WATER PERMIT REVIEW | ¤25.00 | 06/25/2025 |
| WATER MAIN EXTENSION IMPACT | ¤917.27 | 06/25/2025 |
| SITE PLAN 30 | ¤30.00 | 06/25/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤24,982.22 |