Permit #2025060400

Permit Details

Status: COED

Parcel Id: 07-11-31-7024-00180-0050
CONDITIONED SPACE: 1873 sqft
GARAGE: 524 sqft
OPENED PORCH (WITH ROOF) : 249 sqft
Total Square Footage: 2646 sqft
Block: 00180
Subdivision: -
Job Phone: 352-433-8382
Location Address: 23 PRINCE KAAREL LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/25/2025
NOC: RECORDED
Applicant name: ALFREDO E SCHEER
Owner: MARTINS MANUEL D & ANNA DEJESUS MARTINS TRUSTEES

Address

207 LAMBERT AVE

FLAGLER BEACH, FL 32136

Lot: 0050
Contracted Stated Job Value: ¤165,000.00
Job Description: Single Family Residence
Type: CN

Contractor

ESTELA LIVING LLC
Status Location Address State License Number Phone
ACTIVE

237 S. DIXIE HWY, 4TH FLOOR

CORAL GABLES, FL 33133

CGC1534535 (Exp: 08/31/2026) 352-433-8382

Sub Contractors

JOSEPH HORATIO STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PARKWAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2026) 877-906-1113
JOSEPH H STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PKWY

SANFORD, FL 32771

CAC043953 (Exp: 08/31/2026) 877-906-1113
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 06/05/2026 FINAL APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 6/5/2026 12:38:29 PM *** Final Approved 5/5/2026 - PREVIOUS INSPECTION NOTES 5/5/26: 1). No hot water. (breaker is on). FBC-P2722.2 2). right side hose bibb is missing vacuum breaker. FBCR P2902.4.3 3). Right side guest bathroom - tub spout needs to be sealed at the wall. FBC-P2705.1(3) 4). Front entry: drip edge needs to be sealed where it enters stucco. FBC-R903.2 5). Interior dryer exhaust needs to be capped/plugged or taped. FBC-M1502.4.7 6). Primary bathroom shower drain is clogged. FBC-P2705.1(4) 7). Main meter panel identification label is painted over. NEC 110.3(B) - Installation and Use: 8). Dishwasher is unplugged due to outlet configuration and (possibly) cord length. FBC [A] 110.3(6) NOTE: please clear out lanai outlet of excessive spider nests so it can be properly tested.
BLD - BUILDING FINAL 05/05/2026 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/5/2026 1:48:21 PM *** 5/5/26: 1). No hot water. (breaker is on). FBC-P2722.2 2). right side hose bibb is missing vacuum breaker. FBCR P2902.4.3 3). Right side guest bathroom - tub spout needs to be sealed at the wall. FBC-P2705.1(3) 4). Front entry: drip edge needs to be sealed where it enters stucco. FBC-R903.2 5). Interior dryer exhaust needs to be capped/plugged or taped. FBC-M1502.4.7 6). Primary bathroom shower drain is clogged. FBC-P2705.1(4) 7). Main meter panel identification label is painted over. NEC 110.3(B) - Installation and Use: 8). Dishwasher is unplugged due to outlet configuration and (possibly) cord length. FBC [A] 110.3(6) NOTE: please clear out lanai outlet of excessive spider nests so it can be properly tested.
ROW - STORMWATER FINAL 05/05/2026 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 4/20/2026 - PREVIOUS INSPECTION NOTES 1) ALL DIRT AND OVER POURED CONCRETE MUST BE OUT OF CULVERT. 2) ALL BARE AREAS IN THE ADJACENT LOT IN THE BACK MUST HAVE SOD DUE TO THIS IS A IMPROVED PROPERTY. 3) LEFT SIDE IN THE ADJCENT LOT AT HOUSE #21 YOU MUST REPAIR ALL DISTURBED AREAS WITH GRADING AND SOD. SEE PHOTOS FOR REFERENCE OF AREAS.
U -UTILITY RESIDENTIAL FINAL 04/20/2026 FINAL APPROVED BHAINES
Note: Inspector Notes from Inspection 9035 No CC, No IRR.
ROW - FINAL APRON (AFTER POUR) 04/20/2026 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection.
ROW - STORMWATER FINAL 04/20/2026 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) ALL DIRT AND OVER POURED CONCRETE MUST BE OUT OF CULVERT. 2) ALL BARE AREAS IN THE ADJACENT LOT IN THE BACK MUST HAVE SOD DUE TO THIS IS A IMPROVED PROPERTY. 3) LEFT SIDE IN THE ADJCENT LOT AT HOUSE #21 YOU MUST REPAIR ALL DISTURBED AREAS WITH GRADING AND SOD. SEE PHOTOS FOR REFERENCE OF AREAS.
ROW- FINAL SURVEY/GRADING CERTIFICATION 04/16/2026 APPROVED - AS NOTED FSLADISH
Note: 4/16/26 NEWEST UPLOADED LDAGC MEETS MINIMUM COPC STANDARDS AT THE TIME OF THIS REVIEW. BASED ON THE ENGINEER SIGNED AND SEALED LGADC MEETING THE COPC MINIMUM REQUIREMENTS AT THE TIME OF THIS INSPECTION, I AM APPROVING THIS DOCUMENT. Effective 3/25/26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certification for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types. 4/1/2026 - PREVIOUS INSPECTION NOTES ** 04/01/26 MISSED ON YOUR PREVIOUS FINAL SURVEYS: YOU DO NOT HAVE THE REQUIRED FALL WITHIN THE FIRST 10 FT OFF THE REAR OF YOUR STRUCTURE A 5% SLOPE OF 6 INCHES IN THE FIRST 10 FT. THE FINAL GRADE DOES NOT MATCH THE PROPOSED ELEVATIONS SHOWING THE REQUIRED FALL FROM STRUCTURE ** Chapter 4, R401.3- Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) ** "Final Survey. The Final Survey is used to verify compliance with the Topographic Survey, Lot Grading Plan and Swale Plan. (1) A Final Survey must be submitted in person or uploaded online. If the survey is incomplete, unclear, does not adequately show the drainage patterns, or if the constructed drainage is incorrect, it will be disapproved until corrections are made and resubmitted for review and approval. Once any required field changes have been made and the survey has been revised, the contractor shall submit one (1) signed and sealed revised survey for review. If the field changes and/or the revised survey is accepted, a final inspection may be scheduled by the contractor. Section 300.01 F(1) V-17" __________________________________________________________________________________________________________________________ 3/26/2026 - PREVIOUS INSPECTION NOTES THE FINAL SURVEY HAS NO ROADSIDE SWALE ELEVATION AND YOU STATED THAT #34 THAT THE ELEVATION IS WITHIN .10 FROM THE SWALE PLAN. YOU CAN'T SAY YES IF THERE IS NO ELEVATIONS ON SURVEY. -------------------------------------------------------------------------- 3/18/2026 - PREVIOUS INSPECTION NOTES THE FINAL SURVEY HAS NO ROADSIDE SWALE ELEVATION AND YOU STATED THAT #34 THAT THE ELEVATION IS WITHIN .10 FROM THE SWALE PLAN. YOU CAN'T SAY YES IF THERE IS NO ELEVATIONS ON SURVEY.
ROW FIELD SURVEY /GRADING CERTIFICATION 04/16/2026 CANCELLED BY INSPECTOR FSLADISH
Note: 4/16/26 Effective 3/25/26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certification for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types. _____________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 4/16/26 NEWEST UPLOADED LDAGC MEETS MINIMUM COPC STANDARDS AT THE TIME OF THIS REVIEW. BASED ON THE ENGINEER SIGNED AND SEALED LGADC MEETING THE COPC MINIMUM REQUIREMENTS AT THE TIME OF THIS INSPECTION, I AM APPROVING THIS DOCUMENT. Effective 3/25/26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certification for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types. 4/1/2026 - PREVIOUS INSPECTION NOTES ** 04/01/26 MISSED ON YOUR PREVIOUS FINAL SURVEYS: YOU DO NOT HAVE THE REQUIRED FALL WITHIN THE FIRST 10 FT OFF THE REAR OF YOUR STRUCTURE A 5% SLOPE OF 6 INCHES IN THE FIRST 10 FT. THE FINAL GRADE DOES NOT MATCH THE PROPOSED ELEVATIONS SHOWING THE REQUIRED FALL FROM STRUCTURE ** Chapter 4, R401.3- Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) ** "Final Survey. The Final Survey is used to verify compliance with the Topographic Survey, Lot Grading Plan and Swale Plan. (1) A Final Survey must be submitted in person or uploaded online. If the survey is incomplete, unclear, does not adequately show the drainage patterns, or if the constructed drainage is incorrect, it will be disapproved until corrections are made and resubmitted for review and approval. Once any required field changes have been made and the survey has been revised, the contractor shall submit one (1) signed and sealed revised survey for review. If the field changes and/or the revised survey is accepted, a final inspection may be scheduled by the contractor. Section 300.01 F(1) V-17" __________________________________________________________________________________________________________________________ 3/26/2026 - PREVIOUS INSPECTION NOTES THE FINAL SURVEY HAS NO ROADSIDE SWALE ELEVATION AND YOU STATED THAT #34 THAT THE ELEVATION IS WITHIN .10 FROM THE SWALE PLAN. YOU CAN'T SAY YES IF THERE IS NO ELEVATIONS ON SURVEY. -------------------------------------------------------------------------- 3/18/2026 - PREVIOUS INSPECTION NOTES THE FINAL SURVEY HAS NO ROADSIDE SWALE ELEVATION AND YOU STATED THAT #34 THAT THE ELEVATION IS WITHIN .10 FROM THE SWALE PLAN. YOU CAN'T SAY YES IF THERE IS NO ELEVATIONS ON SURVEY.
ROW- FINAL SURVEY/GRADING CERTIFICATION 04/01/2026 Disapproved - NO FEE EMADISON
Note: ** 04/01/26 MISSED ON YOUR PREVIOUS FINAL SURVEYS: YOU DO NOT HAVE THE REQUIRED FALL WITHIN THE FIRST 10 FT OFF THE REAR OF YOUR STRUCTURE A 5% SLOPE OF 6 INCHES IN THE FIRST 10 FT. THE FINAL GRADE DOES NOT MATCH THE PROPOSED ELEVATIONS SHOWING THE REQUIRED FALL FROM STRUCTURE ** Chapter 4, R401.3- Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) ** "Final Survey. The Final Survey is used to verify compliance with the Topographic Survey, Lot Grading Plan and Swale Plan. (1) A Final Survey must be submitted in person or uploaded online. If the survey is incomplete, unclear, does not adequately show the drainage patterns, or if the constructed drainage is incorrect, it will be disapproved until corrections are made and resubmitted for review and approval. Once any required field changes have been made and the survey has been revised, the contractor shall submit one (1) signed and sealed revised survey for review. If the field changes and/or the revised survey is accepted, a final inspection may be scheduled by the contractor. Section 300.01 F(1) V-17" __________________________________________________________________________________________________________________________ 3/26/2026 - PREVIOUS INSPECTION NOTES THE FINAL SURVEY HAS NO ROADSIDE SWALE ELEVATION AND YOU STATED THAT #34 THAT THE ELEVATION IS WITHIN .10 FROM THE SWALE PLAN. YOU CAN'T SAY YES IF THERE IS NO ELEVATIONS ON SURVEY. -------------------------------------------------------------------------- 3/18/2026 - PREVIOUS INSPECTION NOTES THE FINAL SURVEY HAS NO ROADSIDE SWALE ELEVATION AND YOU STATED THAT #34 THAT THE ELEVATION IS WITHIN .10 FROM THE SWALE PLAN. YOU CAN'T SAY YES IF THERE IS NO ELEVATIONS ON SURVEY.
ROW- FINAL SURVEY/GRADING CERTIFICATION 03/26/2026 Disapproved -FEE REQUIRED PFLANAGAN
Note: THE FINAL SURVEY HAS NO ROADSIDE SWALE ELEVATION AND YOU STATED THAT #34 THAT THE ELEVATION IS WITHIN .10 FROM THE SWALE PLAN. YOU CAN'T SAY YES IF THERE IS NO ELEVATIONS ON SURVEY. -------------------------------------------------------------------------- 3/18/2026 - PREVIOUS INSPECTION NOTES THE FINAL SURVEY HAS NO ROADSIDE SWALE ELEVATION AND YOU STATED THAT #34 THAT THE ELEVATION IS WITHIN .10 FROM THE SWALE PLAN. YOU CAN'T SAY YES IF THERE IS NO ELEVATIONS ON SURVEY.
ROW- FINAL SURVEY/GRADING CERTIFICATION 03/18/2026 Disapproved - NO FEE PFLANAGAN
Note: THE FINAL SURVEY HAS NO ROADSIDE SWALE ELEVATION AND YOU STATED THAT #34 THAT THE ELEVATION IS WITHIN .10 FROM THE SWALE PLAN. YOU CAN'T SAY YES IF THERE IS NO ELEVATIONS ON SURVEY.
U-CROSS CONNECTION 02/20/2026 APPROVED - AS NOTED BHAINES
Note: No CC, No IRR.
ROW- PRE-APRON (PRE-POUR) 02/04/2026 APPROVED - AS NOTED EMADISON
Note: ** 02/04/26 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builder’s responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. ** BUILDERS RESPONSIBILITY TO ENSURE CULVERT ELEVATION IS WITHIN TOLERANCE BEFORE THE POUR IN THE EVENT OF RAIN CHECK COMPACTION OF MATERIAL **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300, E RESIDENTIAL CULVERT DETAIL _______________________________________________________________________________________________________________________ 2/2/2026 - PREVIOUS INSPECTION NOTES 2/2/26 YOU DO NOT HAVE YOUR REQUIRED MINIMUM 24" #4 REBAR ON SITE. YOU DO NOT HAVE THE REQUIRED 6" DEPTH FOR YOU MITERED END FOOTERS ON BOTH SIDES AT THE TIME OF THIS INSPECTION.. ___________________________________________________________________________________________________________________________________ 1/30/2026 - PREVIOUS INSPECTION NOTES 1/30/26 RECEIVED TEXT FROM DOUG CM TO PLEASE CANCEL THIS PREPOUR INSPECTION.
ROW- PRE-APRON (PRE-POUR) 02/02/2026 Disapproved -FEE REQUIRED FSLADISH
Note: 2/2/26 YOU DO NOT HAVE YOUR REQUIRED MINIMUM 24" #4 REBAR ON SITE. YOU DO NOT HAVE THE REQUIRED 6" DEPTH FOR YOU MITERED END FOOTERS ON BOTH SIDES AT THE TIME OF THIS INSPECTION.. ___________________________________________________________________________________________________________________________________ 1/30/2026 - PREVIOUS INSPECTION NOTES 1/30/26 RECEIVED TEXT FROM DOUG CM TO PLEASE CANCEL THIS PREPOUR INSPECTION.
ROW- PRE-APRON (PRE-POUR) 01/30/2026 CANCELLED BY APPLICANT FSLADISH
Note: 1/30/26 RECEIVED TEXT FROM DOUG CM TO PLEASE CANCEL THIS PREPOUR INSPECTION.
GRAVITY SEWER TEST 01/21/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 1/21/2026 11:49:02 AM *** Inspector Notes from Inspection 2060 SILT FENCE NEEDS TO EXTEND ACCROSS THE FRONT OF PROPERTY, WATER SERVICE NOT RAN YET
SEWER TIE IN 01/21/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 1/21/2026 11:49:13 AM *** Inspector Notes from Inspection 2060 SILT FENCE NEEDS TO EXTEND ACCROSS THE FRONT OF PROPERTY, WATER SERVICE NOT RAN YET
ELECTRIC - EARLY POWER 12/09/2025 APPROVED - AS NOTED MKRASKI
Note: Emailed FPL @ 10:15am
INSULATION 11/05/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 11/5/2025 9:47:38 AM *** 11/3/2025 - PREVIOUS INSPECTION NOTES 11/3/25: 1). Firestop missing at horizontal area between stud wall and breaker panel pack out. FS written below. FBC-R302.11) 2). Incomplete firestop at dryer exhaust top plate penetration. FBC-R302.11 3). FIRE-BLOCKING missing at top plate cutout in Pantry. Marked FB below area. FBC-R302.11 Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 10/31/2025 2:03:46 PM *** 10/31/25: FPA revision is only accepted as of today's date. This will need to be approved prior to Insulation Inspection. 10/22/2025 - PREVIOUS INSPECTION NOTES 10/22/25: Previously noted items 4, 5, 6 and 7 are not fully resolved. 4). FPA number listed does not match the installed door. FBC-[A] 107.4 5). SGD only the frame is installed so FPA number cannot be verified for installation. FBC-[A] 107.4 > >>> No Product approval sticker on door or frame. Installation cannot be verified. Installation does not match the FPA number shown on the updated Florida Product Approval page submitted to the City. 6). Slab Penetration: Bathtub > Slab at bathtub drain needs to be fully repaired with a cement type product as required for termite protection (FBC-P2603.3.1) and to meet original & minimum slab depth ( FBC [A]107.4 / FBC R506.1). 7). Bathroom exhaust fans are not wired up as required. FBC-[A] 107.4 Also, they are missing mechanical fastner (strap). FBC-M1502.4.2 refers to FBC-M1601.4.1 - Duct connections to flanges of air distribution system equipment shall be sealed and mechanically fastened. 10/14/2025 - PREVIOUS INSPECTION NOTES 10/14/25: 1). No water pressure. FBCR P2503.7 2). No 5ft head pressure. FBC-P2503.5.1 3). Service feed > plan shows 150amp service and requires 2/0 Copper or 4/0 Aluminum. 2/0 Aluminum is installed. Will require a engineer's revision for plan requirements to meet installation. FBC [A]107.4 4). Front entry door requires solid blocking and anchors at the top jamb. FPA number listed does not match the installed door. FBC-[A] 107.4 5). SGD only the frame is installed so FPA number cannot be verified for installation. FBC-[A] 107.4 6). Slab Penetration: Bathtub > Slab at bathtub drain needs to be fully repaired with a cement type product as required for termite protection (FBC-P2603.3.1) and to meet original & minimum slab depth ( FBC [A]107.4 / FBC R506.1). 7). Bathroom exhaust fans are not wired up as required. FBC-[A] 107.4 Also, they are missing mechanical fastner (strap). FBC-M1502.4.2
INSULATION 11/03/2025 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 11/3/2025 9:57:47 AM *** 11/3/25: 1). Firestop missing at horizontal area between stud wall and breaker panel pack out. FS written below. FBC-R302.11) 2). Incomplete firestop at dryer exhaust top plate penetration. FBC-R302.11 3). FIRE-BLOCKING missing at top plate cutout in Pantry. Marked FB below area. FBC-R302.11 Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 10/31/2025 2:03:46 PM *** 10/31/25: FPA revision is only accepted as of today's date. This will need to be approved prior to Insulation Inspection. 10/22/2025 - PREVIOUS INSPECTION NOTES 10/22/25: Previously noted items 4, 5, 6 and 7 are not fully resolved. 4). FPA number listed does not match the installed door. FBC-[A] 107.4 5). SGD only the frame is installed so FPA number cannot be verified for installation. FBC-[A] 107.4 > >>> No Product approval sticker on door or frame. Installation cannot be verified. Installation does not match the FPA number shown on the updated Florida Product Approval page submitted to the City. 6). Slab Penetration: Bathtub > Slab at bathtub drain needs to be fully repaired with a cement type product as required for termite protection (FBC-P2603.3.1) and to meet original & minimum slab depth ( FBC [A]107.4 / FBC R506.1). 7). Bathroom exhaust fans are not wired up as required. FBC-[A] 107.4 Also, they are missing mechanical fastner (strap). FBC-M1502.4.2 refers to FBC-M1601.4.1 - Duct connections to flanges of air distribution system equipment shall be sealed and mechanically fastened. 10/14/2025 - PREVIOUS INSPECTION NOTES 10/14/25: 1). No water pressure. FBCR P2503.7 2). No 5ft head pressure. FBC-P2503.5.1 3). Service feed > plan shows 150amp service and requires 2/0 Copper or 4/0 Aluminum. 2/0 Aluminum is installed. Will require a engineer's revision for plan requirements to meet installation. FBC [A]107.4 4). Front entry door requires solid blocking and anchors at the top jamb. FPA number listed does not match the installed door. FBC-[A] 107.4 5). SGD only the frame is installed so FPA number cannot be verified for installation. FBC-[A] 107.4 6). Slab Penetration: Bathtub > Slab at bathtub drain needs to be fully repaired with a cement type product as required for termite protection (FBC-P2603.3.1) and to meet original & minimum slab depth ( FBC [A]107.4 / FBC R506.1). 7). Bathroom exhaust fans are not wired up as required. FBC-[A] 107.4 Also, they are missing mechanical fastner (strap). FBC-M1502.4.2
ALL ROUGH 10/31/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 10/31/2025 2:03:46 PM *** 10/31/25: FPA revision is only accepted as of today's date. This will need to be approved prior to Insulation Inspection. 10/22/2025 - PREVIOUS INSPECTION NOTES 10/22/25: Previously noted items 4, 5, 6 and 7 are not fully resolved. 4). FPA number listed does not match the installed door. FBC-[A] 107.4 5). SGD only the frame is installed so FPA number cannot be verified for installation. FBC-[A] 107.4 > >>> No Product approval sticker on door or frame. Installation cannot be verified. Installation does not match the FPA number shown on the updated Florida Product Approval page submitted to the City. 6). Slab Penetration: Bathtub > Slab at bathtub drain needs to be fully repaired with a cement type product as required for termite protection (FBC-P2603.3.1) and to meet original & minimum slab depth ( FBC [A]107.4 / FBC R506.1). 7). Bathroom exhaust fans are not wired up as required. FBC-[A] 107.4 Also, they are missing mechanical fastner (strap). FBC-M1502.4.2 refers to FBC-M1601.4.1 - Duct connections to flanges of air distribution system equipment shall be sealed and mechanically fastened. 10/14/2025 - PREVIOUS INSPECTION NOTES 10/14/25: 1). No water pressure. FBCR P2503.7 2). No 5ft head pressure. FBC-P2503.5.1 3). Service feed > plan shows 150amp service and requires 2/0 Copper or 4/0 Aluminum. 2/0 Aluminum is installed. Will require a engineer's revision for plan requirements to meet installation. FBC [A]107.4 4). Front entry door requires solid blocking and anchors at the top jamb. FPA number listed does not match the installed door. FBC-[A] 107.4 5). SGD only the frame is installed so FPA number cannot be verified for installation. FBC-[A] 107.4 6). Slab Penetration: Bathtub > Slab at bathtub drain needs to be fully repaired with a cement type product as required for termite protection (FBC-P2603.3.1) and to meet original & minimum slab depth ( FBC [A]107.4 / FBC R506.1). 7). Bathroom exhaust fans are not wired up as required. FBC-[A] 107.4 Also, they are missing mechanical fastner (strap). FBC-M1502.4.2
LATH/BRICK/ WATER BARRIER 10/22/2025 APPROVED RSIMS
Note: 10/15/2025 - PREVIOUS INSPECTION NOTES 10/15/25: 1). Right side of house: CMU and footer cut out for plumbing supply needs to be repaired with cement type product as required. (Also, wire lath fell off and is not sufficient for the repair). FBC-[A] 107.4
ALL ROUGH 10/22/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 10/22/2025 1:37:47 PM *** 10/22/25: Previously noted items 4, 5, 6 and 7 are not fully resolved. 4). FPA number listed does not match the installed door. FBC-[A] 107.4 5). SGD only the frame is installed so FPA number cannot be verified for installation. FBC-[A] 107.4 > >>> No Product approval sticker on door or frame. Installation cannot be verified. Installation does not match the FPA number shown on the updated Florida Product Approval page submitted to the City. 6). Slab Penetration: Bathtub > Slab at bathtub drain needs to be fully repaired with a cement type product as required for termite protection (FBC-P2603.3.1) and to meet original & minimum slab depth ( FBC [A]107.4 / FBC R506.1). 7). Bathroom exhaust fans are not wired up as required. FBC-[A] 107.4 Also, they are missing mechanical fastner (strap). FBC-M1502.4.2 refers to FBC-M1601.4.1 - Duct connections to flanges of air distribution system equipment shall be sealed and mechanically fastened. 10/14/2025 - PREVIOUS INSPECTION NOTES 10/14/25: 1). No water pressure. FBCR P2503.7 2). No 5ft head pressure. FBC-P2503.5.1 3). Service feed > plan shows 150amp service and requires 2/0 Copper or 4/0 Aluminum. 2/0 Aluminum is installed. Will require a engineer's revision for plan requirements to meet installation. FBC [A]107.4 4). Front entry door requires solid blocking and anchors at the top jamb. FPA number listed does not match the installed door. FBC-[A] 107.4 5). SGD only the frame is installed so FPA number cannot be verified for installation. FBC-[A] 107.4 6). Slab Penetration: Bathtub > Slab at bathtub drain needs to be fully repaired with a cement type product as required for termite protection (FBC-P2603.3.1) and to meet original & minimum slab depth ( FBC [A]107.4 / FBC R506.1). 7). Bathroom exhaust fans are not wired up as required. FBC-[A] 107.4 Also, they are missing mechanical fastner (strap). FBC-M1502.4.2
LATH/BRICK/ WATER BARRIER 10/15/2025 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 10/15/2025 10:41:06 AM *** 10/15/25: 1). Right side of house: CMU and footer cut out for plumbing supply needs to be repaired with cement type product as required. (Also, wire lath fell off and is not sufficient for the repair). FBC-[A] 107.4
ALL ROUGH 10/14/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 10/14/2025 2:06:41 PM *** 10/14/25: 1). No water pressure. FBCR P2503.7 2). No 5ft head pressure. FBC-P2503.5.1 3). Service feed > plan shows 150amp service and requires 2/0 Copper or 4/0 Aluminum. 2/0 Aluminum is installed. Will require a engineer's revision for plan requirements to meet installation. FBC [A]107.4 4). Front entry door requires solid blocking and anchors at the top jamb. FPA number listed does not match the installed door. FBC-[A] 107.4 5). SGD only the frame is installed so FPA number cannot be verified for installation. FBC-[A] 107.4 6). Slab Penetration: Bathtub > Slab at bathtub drain needs to be fully repaired with a cement type product as required for termite protection (FBC-P2603.3.1) and to meet original & minimum slab depth ( FBC [A]107.4 / FBC R506.1). 7). Bathroom exhaust fans are not wired up as required. FBC-[A] 107.4 Also, they are missing mechanical fastner (strap). FBC-M1502.4.2
WALL SHEATHING 10/09/2025 Disapproved - NO FEE MCONTRYMAN
Note: 10/9/25 Previous note needs to be addressed before any inspection can be passed. Culvert been noted since slab inspection (9/16/25) 4). Silt fence needs repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale, and safe job site access. FBC 3307.1 / FBC 3303.5 --Inspection itself was good, but not passed due to above note-- 10/8/2025 - PREVIOUS INSPECTION NOTES 10/8/25 Previous note needs to be addressed before any inspection can be passed. Culvert been noted since slab inspection (9/16/25) 4). Silt fence needs repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale, and safe job site access. FBC 3307.1 / FBC 3303.5 --Inspection itself was good, but not passed due to above note--
WALL SHEATHING 10/09/2025 APPROVED MCONTRYMAN
Note: 10/9/2025 - PREVIOUS INSPECTION NOTES 10/9/25 Previous note needs to be addressed before any inspection can be passed. Culvert been noted since slab inspection (9/16/25) 4). Silt fence needs repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale, and safe job site access. FBC 3307.1 / FBC 3303.5 --Inspection itself was good, but not passed due to above note-- 10/8/2025 - PREVIOUS INSPECTION NOTES 10/8/25 Previous note needs to be addressed before any inspection can be passed. Culvert been noted since slab inspection (9/16/25) 4). Silt fence needs repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale, and safe job site access. FBC 3307.1 / FBC 3303.5 --Inspection itself was good, but not passed due to above note--
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/09/2025 Disapproved -FEE REQUIRED MCONTRYMAN
Note: 10/9/25 Previous note needs to be addressed before any inspection can be passed. Culvert been noted since slab inspection (9/16/25) 4). Silt fence needs repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale, and safe job site access. FBC 3307.1 / FBC 3303.5 --Inspection itself was good, but not passed due to above note-- 10/8/2025 - PREVIOUS INSPECTION NOTES 10/8/25 Previous note needs to be addressed before any inspection can be passed. Culvert been noted since slab inspection (9/16/25) 4). Silt fence needs repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale, and safe job site access. FBC 3307.1 / FBC 3303.5 --Inspection itself was good, but not passed due to above note-- 10/2/2025 - PREVIOUS INSPECTION NOTES 10/2/25: Incomplete Inspection due to extremely damaged plans in permit box. 1). Permit box needs attention. Please replace damaged plans with new approved plans including Truss packet. FBC [A]107.3.1 2). Miscellaneous trusses missing shim/barrier between truss and CMU wall. Most spots orange paint line below. Builder to check all. FBC-R317.1 and on plans. FBC [A]107.4 3). Front entry straps/anchors are not visable above plywood overvalley section. Could not check. FBC[A]110.1 4). Swale area needs to be cleaned up, Silt fence repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale. FBC 3307.1 / FBC 3303.5 5). Please empty overflowing dumpster and have excess debris/trash cleaned up to make site safe for inspections. FBC-[A] 101.3 6). Roof sheathing bump checked. Garage has an area of roof sheathing that is damaged and requires replacement/repair. Marked on wall below. FBC [A]107.4 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 9/18/2025 1:57:31 PM *** 9/18/25: Previously listed item 2 remains un resolved. This will need to be resolved before any other inspections will be approved. 2). Silt fence still needs to be repaired at the back as previously noted (along with the front areas now). FBC 3307.1. Also, swale area needs to be clear to allow water to flow freely through the swale as required. FBC 3303.5. (currently has standing water due to condition of swale area). ***** NOTE: Trusses have been placed directly on the dirt which is not in compliance with Truss manufacturer's requirements for placement. May require a moisture test and/or engineer's letter for repair of any damaged trusses. 9/16/2025 - PREVIOUS INSPECTION NOTES 9/16/25: 1). Right side of front entry: Dowel / down rods do not meet the minimum clearance (2" from face of block and/or 3/4: from inside of block) as required. (FBC-R606.3.4) Spray painted orange. 2). Silt fence still needs to be repaired at the back as previously noted (along with the front areas now). FBC 3307.1 NOTE: a temporary culvert pipe will be required to allow free flow of water through the swale as required. FBC 3303.5. (currently has standing water due to condition of swale area). Also: Trusses have been placed directly on the dirt which is not in compliance with Truss manufacturer's requirements for placement. May require a moisture test and/or engineer's letter for repair of any damaged trusses. Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 9/2/2025 11:07:38 AM *** 9/2/25: 1). Silt fence needs to be repaired at the back. FBC 3307.1 Must be complete prior to next inspection.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/09/2025 APPROVED MCONTRYMAN
Note: 10/9/2025 - PREVIOUS INSPECTION NOTES 10/9/25 Previous note needs to be addressed before any inspection can be passed. Culvert been noted since slab inspection (9/16/25) 4). Silt fence needs repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale, and safe job site access. FBC 3307.1 / FBC 3303.5 --Inspection itself was good, but not passed due to above note-- 10/8/2025 - PREVIOUS INSPECTION NOTES 10/8/25 Previous note needs to be addressed before any inspection can be passed. Culvert been noted since slab inspection (9/16/25) 4). Silt fence needs repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale, and safe job site access. FBC 3307.1 / FBC 3303.5 --Inspection itself was good, but not passed due to above note-- 10/2/2025 - PREVIOUS INSPECTION NOTES 10/2/25: Incomplete Inspection due to extremely damaged plans in permit box. 1). Permit box needs attention. Please replace damaged plans with new approved plans including Truss packet. FBC [A]107.3.1 2). Miscellaneous trusses missing shim/barrier between truss and CMU wall. Most spots orange paint line below. Builder to check all. FBC-R317.1 and on plans. FBC [A]107.4 3). Front entry straps/anchors are not visable above plywood overvalley section. Could not check. FBC[A]110.1 4). Swale area needs to be cleaned up, Silt fence repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale. FBC 3307.1 / FBC 3303.5 5). Please empty overflowing dumpster and have excess debris/trash cleaned up to make site safe for inspections. FBC-[A] 101.3 6). Roof sheathing bump checked. Garage has an area of roof sheathing that is damaged and requires replacement/repair. Marked on wall below. FBC [A]107.4 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 9/18/2025 1:57:31 PM *** 9/18/25: Previously listed item 2 remains un resolved. This will need to be resolved before any other inspections will be approved. 2). Silt fence still needs to be repaired at the back as previously noted (along with the front areas now). FBC 3307.1. Also, swale area needs to be clear to allow water to flow freely through the swale as required. FBC 3303.5. (currently has standing water due to condition of swale area). ***** NOTE: Trusses have been placed directly on the dirt which is not in compliance with Truss manufacturer's requirements for placement. May require a moisture test and/or engineer's letter for repair of any damaged trusses. 9/16/2025 - PREVIOUS INSPECTION NOTES 9/16/25: 1). Right side of front entry: Dowel / down rods do not meet the minimum clearance (2" from face of block and/or 3/4: from inside of block) as required. (FBC-R606.3.4) Spray painted orange. 2). Silt fence still needs to be repaired at the back as previously noted (along with the front areas now). FBC 3307.1 NOTE: a temporary culvert pipe will be required to allow free flow of water through the swale as required. FBC 3303.5. (currently has standing water due to condition of swale area). Also: Trusses have been placed directly on the dirt which is not in compliance with Truss manufacturer's requirements for placement. May require a moisture test and/or engineer's letter for repair of any damaged trusses. Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 9/2/2025 11:07:38 AM *** 9/2/25: 1). Silt fence needs to be repaired at the back. FBC 3307.1 Must be complete prior to next inspection.
ROOF VALLEY & METAL 10/09/2025 Disapproved - NO FEE MCONTRYMAN
Note: 10/9/25 Previous note needs to be addressed before any inspection can be passed. Culvert been noted since slab inspection (9/16/25) 4). Silt fence needs repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale, and safe job site access. FBC 3307.1 / FBC 3303.5 --Inspection itself was good, but not passed due to above note-- 10/8/2025 - PREVIOUS INSPECTION NOTES 10/8/25 Previous note needs to be addressed before any inspection can be passed. Culvert been noted since slab inspection (9/16/25) 4). Silt fence needs repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale, and safe job site access. FBC 3307.1 / FBC 3303.5 --Inspection itself was good, but not passed due to above note-- New inspection due to canceled inspection 10/3/2025 - PREVIOUS INSPECTION NOTES 10/3/25: Must have an approved inspection 2460 or 2465 prior to this inspection.
ROOF VALLEY & METAL 10/09/2025 APPROVED MCONTRYMAN
Note: 10/9/2025 - PREVIOUS INSPECTION NOTES 10/9/25 Previous note needs to be addressed before any inspection can be passed. Culvert been noted since slab inspection (9/16/25) 4). Silt fence needs repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale, and safe job site access. FBC 3307.1 / FBC 3303.5 --Inspection itself was good, but not passed due to above note-- 10/8/2025 - PREVIOUS INSPECTION NOTES 10/8/25 Previous note needs to be addressed before any inspection can be passed. Culvert been noted since slab inspection (9/16/25) 4). Silt fence needs repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale, and safe job site access. FBC 3307.1 / FBC 3303.5 --Inspection itself was good, but not passed due to above note-- New inspection due to canceled inspection 10/3/2025 - PREVIOUS INSPECTION NOTES 10/3/25: Must have an approved inspection 2460 or 2465 prior to this inspection.
ROOF VALLEY & METAL 10/08/2025 Disapproved - NO FEE MCONTRYMAN
Note: 10/8/25 Previous note needs to be addressed before any inspection can be passed. Culvert been noted since slab inspection (9/16/25) 4). Silt fence needs repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale, and safe job site access. FBC 3307.1 / FBC 3303.5 --Inspection itself was good, but not passed due to above note-- New inspection due to canceled inspection 10/3/2025 - PREVIOUS INSPECTION NOTES 10/3/25: Must have an approved inspection 2460 or 2465 prior to this inspection.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/08/2025 Disapproved -FEE REQUIRED MCONTRYMAN
Note: 10/8/25 Previous note needs to be addressed before any inspection can be passed. Culvert been noted since slab inspection (9/16/25) 4). Silt fence needs repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale, and safe job site access. FBC 3307.1 / FBC 3303.5 --Inspection itself was good, but not passed due to above note-- 10/2/2025 - PREVIOUS INSPECTION NOTES 10/2/25: Incomplete Inspection due to extremely damaged plans in permit box. 1). Permit box needs attention. Please replace damaged plans with new approved plans including Truss packet. FBC [A]107.3.1 2). Miscellaneous trusses missing shim/barrier between truss and CMU wall. Most spots orange paint line below. Builder to check all. FBC-R317.1 and on plans. FBC [A]107.4 3). Front entry straps/anchors are not visable above plywood overvalley section. Could not check. FBC[A]110.1 4). Swale area needs to be cleaned up, Silt fence repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale. FBC 3307.1 / FBC 3303.5 5). Please empty overflowing dumpster and have excess debris/trash cleaned up to make site safe for inspections. FBC-[A] 101.3 6). Roof sheathing bump checked. Garage has an area of roof sheathing that is damaged and requires replacement/repair. Marked on wall below. FBC [A]107.4 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 9/18/2025 1:57:31 PM *** 9/18/25: Previously listed item 2 remains un resolved. This will need to be resolved before any other inspections will be approved. 2). Silt fence still needs to be repaired at the back as previously noted (along with the front areas now). FBC 3307.1. Also, swale area needs to be clear to allow water to flow freely through the swale as required. FBC 3303.5. (currently has standing water due to condition of swale area). ***** NOTE: Trusses have been placed directly on the dirt which is not in compliance with Truss manufacturer's requirements for placement. May require a moisture test and/or engineer's letter for repair of any damaged trusses. 9/16/2025 - PREVIOUS INSPECTION NOTES 9/16/25: 1). Right side of front entry: Dowel / down rods do not meet the minimum clearance (2" from face of block and/or 3/4: from inside of block) as required. (FBC-R606.3.4) Spray painted orange. 2). Silt fence still needs to be repaired at the back as previously noted (along with the front areas now). FBC 3307.1 NOTE: a temporary culvert pipe will be required to allow free flow of water through the swale as required. FBC 3303.5. (currently has standing water due to condition of swale area). Also: Trusses have been placed directly on the dirt which is not in compliance with Truss manufacturer's requirements for placement. May require a moisture test and/or engineer's letter for repair of any damaged trusses. Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 9/2/2025 11:07:38 AM *** 9/2/25: 1). Silt fence needs to be repaired at the back. FBC 3307.1 Must be complete prior to next inspection.
WALL SHEATHING 10/08/2025 Disapproved - NO FEE MCONTRYMAN
Note: 10/8/25 Previous note needs to be addressed before any inspection can be passed. Culvert been noted since slab inspection (9/16/25) 4). Silt fence needs repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale, and safe job site access. FBC 3307.1 / FBC 3303.5 --Inspection itself was good, but not passed due to above note--
ROOF VALLEY & METAL 10/06/2025 CANCELLED BY APPLICANT WEB
Note: 10/3/2025 - PREVIOUS INSPECTION NOTES 10/3/25: Must have an approved inspection 2460 or 2465 prior to this inspection.
ROOF VALLEY & METAL 10/03/2025 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 10/3/2025 8:09:03 AM *** 10/3/25: Must have an approved inspection 2460 or 2465 prior to this inspection.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/02/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 10/2/2025 1:28:57 PM *** 10/2/25: Incomplete Inspection due to extremely damaged plans in permit box. 1). Permit box needs attention. Please replace damaged plans with new approved plans including Truss packet. FBC [A]107.3.1 2). Miscellaneous trusses missing shim/barrier between truss and CMU wall. Most spots orange paint line below. Builder to check all. FBC-R317.1 and on plans. FBC [A]107.4 3). Front entry straps/anchors are not visable above plywood overvalley section. Could not check. FBC[A]110.1 4). Swale area needs to be cleaned up, Silt fence repaired and a temporary culvert pipe installed per Storm Water requirements to allow free flow of water through the swale. FBC 3307.1 / FBC 3303.5 5). Please empty overflowing dumpster and have excess debris/trash cleaned up to make site safe for inspections. FBC-[A] 101.3 6). Roof sheathing bump checked. Garage has an area of roof sheathing that is damaged and requires replacement/repair. Marked on wall below. FBC [A]107.4 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 9/18/2025 1:57:31 PM *** 9/18/25: Previously listed item 2 remains un resolved. This will need to be resolved before any other inspections will be approved. 2). Silt fence still needs to be repaired at the back as previously noted (along with the front areas now). FBC 3307.1. Also, swale area needs to be clear to allow water to flow freely through the swale as required. FBC 3303.5. (currently has standing water due to condition of swale area). ***** NOTE: Trusses have been placed directly on the dirt which is not in compliance with Truss manufacturer's requirements for placement. May require a moisture test and/or engineer's letter for repair of any damaged trusses. 9/16/2025 - PREVIOUS INSPECTION NOTES 9/16/25: 1). Right side of front entry: Dowel / down rods do not meet the minimum clearance (2" from face of block and/or 3/4: from inside of block) as required. (FBC-R606.3.4) Spray painted orange. 2). Silt fence still needs to be repaired at the back as previously noted (along with the front areas now). FBC 3307.1 NOTE: a temporary culvert pipe will be required to allow free flow of water through the swale as required. FBC 3303.5. (currently has standing water due to condition of swale area). Also: Trusses have been placed directly on the dirt which is not in compliance with Truss manufacturer's requirements for placement. May require a moisture test and/or engineer's letter for repair of any damaged trusses. Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 9/2/2025 11:07:38 AM *** 9/2/25: 1). Silt fence needs to be repaired at the back. FBC 3307.1 Must be complete prior to next inspection.
TIE BEAM / LINTEL 09/18/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 9/18/2025 1:57:31 PM *** 9/18/25: Previously listed item 2 remains un resolved. This will need to be resolved before any other inspections will be approved. 2). Silt fence still needs to be repaired at the back as previously noted (along with the front areas now). FBC 3307.1. Also, swale area needs to be clear to allow water to flow freely through the swale as required. FBC 3303.5. (currently has standing water due to condition of swale area). ***** NOTE: Trusses have been placed directly on the dirt which is not in compliance with Truss manufacturer's requirements for placement. May require a moisture test and/or engineer's letter for repair of any damaged trusses. 9/16/2025 - PREVIOUS INSPECTION NOTES 9/16/25: 1). Right side of front entry: Dowel / down rods do not meet the minimum clearance (2" from face of block and/or 3/4: from inside of block) as required. (FBC-R606.3.4) Spray painted orange. 2). Silt fence still needs to be repaired at the back as previously noted (along with the front areas now). FBC 3307.1 NOTE: a temporary culvert pipe will be required to allow free flow of water through the swale as required. FBC 3303.5. (currently has standing water due to condition of swale area). Also: Trusses have been placed directly on the dirt which is not in compliance with Truss manufacturer's requirements for placement. May require a moisture test and/or engineer's letter for repair of any damaged trusses. Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 9/2/2025 11:07:38 AM *** 9/2/25: 1). Silt fence needs to be repaired at the back. FBC 3307.1 Must be complete prior to next inspection.
TIE BEAM / LINTEL 09/16/2025 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 9/16/2025 9:40:00 AM *** 9/16/25: 1). Right side of front entry: Dowel / down rods do not meet the minimum clearance (2" from face of block and/or 3/4: from inside of block) as required. (FBC-R606.3.4) Spray painted orange. 2). Silt fence still needs to be repaired at the back as previously noted (along with the front areas now). FBC 3307.1 NOTE: a temporary culvert pipe will be required to allow free flow of water through the swale as required. FBC 3303.5. (currently has standing water due to condition of swale area). Also: Trusses have been placed directly on the dirt which is not in compliance with Truss manufacturer's requirements for placement. May require a moisture test and/or engineer's letter for repair of any damaged trusses. Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 9/2/2025 11:07:38 AM *** 9/2/25: 1). Silt fence needs to be repaired at the back. FBC 3307.1 Must be complete prior to next inspection.
MONOLITHIC SLAB 09/02/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 9/2/2025 11:07:38 AM *** 9/2/25: 1). Silt fence needs to be repaired at the back. FBC 3307.1 Must be complete prior to next inspection.
PLUMBING 1ST ROUGH UNDERGROUND 08/28/2025 APPROVED - AS NOTED MGIBSON
Note: SILT FENCE NEEDS TO EXTEND ACCROSS THE FRONT OF PROPERTY, WATER SERVICE NOT RAN YET
FORMBOARD SURVEY (OFFICE USE ONLY) 08/27/2025 APPROVED PFLANAGAN
WATER METER INSTALLATION REQUEST 08/19/2025 APPROVED CBOWERMASTER
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 08/18/2025 APPROVED PKNAPIK

Review History

Department Status Date In Date Out
BLD COMPLETE 10/28/2025 10/31/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
ELEC COMPLETE 10/20/2025 10/23/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 10/06/2025 10/08/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SW1 COMPLETE 08/26/2025 08/27/2025
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 08/26/2025 08/27/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SW1 HOLD 08/22/2025 08/25/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Formboard FFE shall be to the nearest 0.01. Please submit revised formboard survey.
ZON COMPLETE 08/22/2025 08/22/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 08/13/2025 08/18/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD HOLD 08/11/2025 08/12/2025
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Provide initial Geotech report
SW1 COMPLETE 06/20/2025 06/25/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/20/2025 06/23/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ZON COMPLETE 06/20/2025 06/20/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
SW1 HOLD 06/17/2025 06/18/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Previous comments still not addresses: Proposed flow lines shall be lower than elevations along the front property line. This ensures water is contained to the yard drainage swale. Please revise so the flow line at the front right of the property meet COPC requirements. Please feel free to call or email if there are any questions or concerns.
ENGIN1 COMPLETE 06/17/2025 06/18/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ZON COMPLETE 06/17/2025 06/17/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
SWALE COMPLETE 06/10/2025 06/25/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
BADMIN COMPLETE 06/09/2025 06/13/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 06/09/2025 06/13/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 06/09/2025 06/12/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 06/09/2025 06/16/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/09/2025 06/10/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 06/09/2025 06/12/2025
LOCATE COMPLETE 06/09/2025 06/11/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 06/09/2025 06/12/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 06/09/2025 06/16/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Proposed flow lines at the front of the property are higher than the front property line elevations. Please revise.
ZON COMPLETE 06/09/2025 06/10/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
RSI REINSPECTION 1 ¤35.00 05/15/2026
RSI REINSPECTION 1 ¤35.00 05/15/2026
RSI REINSPECTION 1 ¤35.00 05/15/2026
REINSPECTION RESIDENTIAL ¤40.00 05/15/2026
REINSPECTION RESIDENTIAL ¤40.00 05/15/2026
REINSPECTION RESIDENTIAL ¤40.00 05/15/2026
REINSPECTION RESIDENTIAL ¤40.00 05/15/2026
REINSPECTION RESIDENTIAL ¤40.00 05/15/2026
REINSPECTION RESIDENTIAL ¤40.00 05/15/2026
FC IMPACT FEE EMS ¤62.00 06/25/2025
IMPACT FEE FIRE ¤434.51 06/25/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 06/25/2025
FC IMPACT FEE LIBRARY ¤268.00 06/25/2025
IMPACT FEE PARKS ¤1,828.01 06/25/2025
IMPACT FEE SCHOOL ¤5,450.00 06/25/2025
IMPACT FEE TRANSPORTATION ¤1,916.00 06/25/2025
WATER- TURN ON ¤50.00 06/25/2025
ADJUSTMENT 10% (¤131.49) 06/25/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 06/25/2025
INSPECTION - RESIDENTIAL ¤1,001.00 06/25/2025
PLAN REVIEW - RESIDENTIAL ¤283.92 06/25/2025
WASTEWATER MAIN EXTENSION IMPA ¤2,385.00 06/25/2025
SURCHARGE FS 533.721 ¤11.83 06/25/2025
SURCHARGE - FS 468.631 ¤17.75 06/25/2025
SW ENG - FOUNDATION SURVEY ¤20.00 06/25/2025
SW ENG INSPECTION 80 ¤80.00 06/25/2025
SW ENG PRE APRON ¤30.00 06/25/2025
SW ENG - REVIEW 20 ¤20.00 06/25/2025
SW ENG RES REVIEW 200 ¤200.00 06/25/2025
WATER METER W/ TAP ¤2,326.93 06/25/2025
SEWER CREDIT (¤1,147.00) 06/25/2025
WASTEWATER PERM INSPECTION ¤80.00 06/25/2025
WASTEWATER PERM REVIEW ¤25.00 06/25/2025
SEWER CAPITAL FACILITY ¤4,415.00 06/25/2025
WATER CAPITAL FACILITY FEE ¤3,790.49 06/25/2025
WATER PERMIT REVIEW ¤25.00 06/25/2025
WATER MAIN EXTENSION IMPACT ¤917.27 06/25/2025
SITE PLAN 30 ¤30.00 06/25/2025
Fees Total Due: ¤0.00 Total Paid: ¤24,982.22