I want to search for...
Permit #2025060459
Permit Details
Status: COED
| Parcel Id: 07-11-31-5320-00000-0300 |
| Block: 00000 |
| Subdivision: - |
| Job Phone: 904-731-5580 |
| Location Address: 100 RAINTREE CIR |
| Type: WD - WINDOWS/DOORS |
| Issue Date: 06/26/2025 |
| NOC: Unknown |
| Applicant name: JEFFREY ALLEN BRIAR |
| Owner: MILNES CHRISTOPHER R & MARIE CHRISTINE MILNES H&W |
|
Address 100 RAINTREE CIRCLE PALM COAST, FL 32164 |
| Lot: 0300 |
| Contracted Stated Job Value: ¤2,400.00 |
| Job Description: 1 Replacement Window |
| Type: CN |
Contractor
LIFETIME ENCLOSURES INC.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
5521 CHRONICLE COURT JACKSONVILLE, FL 32256 |
CRC028471 (Exp: 08/31/2026) | 904-731-5580 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL - BUILDING MISC | 01/07/2026 | FINAL APPROVED | CVANSTRAHLEN |
| Note: 11/18/2025 - PREVIOUS INSPECTION NOTES PLease fix item before next inspection #1- missing window FL approval label on window , trim is detaching front right side of the window bottom right side 10/23/2025 - PREVIOUS INSPECTION NOTES 10/23/25: NOT READY FOR FINAL INSPECTION. A FULL INSPECTION WILL NEED TO BE COMPLETED ONCE READY! 1). Window installation does not meet Manufacturer's requirements for anchoring, etc. 2). Shim space cannot exceed 1/4" (requires solid blocking) and any solid blocking installed against concrete/cement products needs to be pressure treated. 3). Window does not have spray foam around the perimeter as required. 4). window is not finish sealed as required. | |||
| FINAL - BUILDING MISC | 11/18/2025 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: PLease fix item before next inspection #1- missing window FL approval label on window , trim is detaching front right side of the window bottom right side 10/23/2025 - PREVIOUS INSPECTION NOTES 10/23/25: NOT READY FOR FINAL INSPECTION. A FULL INSPECTION WILL NEED TO BE COMPLETED ONCE READY! 1). Window installation does not meet Manufacturer's requirements for anchoring, etc. 2). Shim space cannot exceed 1/4" (requires solid blocking) and any solid blocking installed against concrete/cement products needs to be pressure treated. 3). Window does not have spray foam around the perimeter as required. 4). window is not finish sealed as required. | |||
| FINAL - BUILDING MISC | 10/23/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 10/23/2025 1:15:00 PM *** 10/23/25: NOT READY FOR FINAL INSPECTION. A FULL INSPECTION WILL NEED TO BE COMPLETED ONCE READY! 1). Window installation does not meet Manufacturer's requirements for anchoring, etc. 2). Shim space cannot exceed 1/4" (requires solid blocking) and any solid blocking installed against concrete/cement products needs to be pressure treated. 3). Window does not have spray foam around the perimeter as required. 4). window is not finish sealed as required. |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 12/09/2025 | 12/10/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 06/10/2025 | 06/10/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EXTENSION | ¤40.00 | 01/06/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 01/06/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 11/17/2025 |
| SURCHARGE FS 533.721 | ¤2.00 | 06/26/2025 |
| SURCHARGE - FS 468.631 | ¤2.00 | 06/26/2025 |
| INSPECTION - RESIDENTIAL | ¤60.00 | 06/26/2025 |
| ADJUSTMENT 10% | (¤9.00) | 06/26/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 06/26/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤205.00 |