Permit #2025060583

Permit Details

Status: INSPECT

Parcel Id: 07-11-31-7026-00040-0090
CONDITIONED SPACE: 2147 sqft
OPENED PORCH (WITH ROOF) : 120 sqft
GARAGE: 592 sqft
OPENED PORCH (WITH ROOF) : 35 sqft
Total Square Footage: 2894 sqft
Block: 00040
Subdivision: -
Job Phone: 407-476-8195
Location Address: 17 PINE HAVEN DR
Type: BRMOD - BUILDING RESIDENTIAL MODEL (NOT FOR RESIDENCE)
Issue Date: 08/27/2025
NOC: RECORDED
Applicant name: CARLETTE RENE WITTE
Owner: INB BFS LLC

Address

3670 MAGUIRE BOULEVARD

ORLANDO, FL 32803

Address

SUITE 220

ORLANDO, FL 32803

Lot: 0090
Contracted Stated Job Value: ¤250,000.00
Job Description: single family residence MODEL HOME
Type: CN

Contractor

INNOVATIVE NATIONWIDE BUILDERS INC
Status Location Address State License Number Phone
ACTIVE

3670 MAGUIRE BLVD #220

,

CRC1330026 (Exp: 08/31/2026) 855-694-6634

Sub Contractors

ROBERT MICHAEL RENNER
Status Location Address State License Number Phone
ACTIVE

531 CODISCO WAY

SANFORD, FL 32771

CAC051477 (Exp: 08/31/2026) 407-333-2665
TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733
HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
ANTHONY OKEITH FENNELL
Status Location Address State License Number Phone
ACTIVE

217 N. WESTMONTE DR, SUITE 1007

ALTAMONTE SPRINGS, FL 32714

EC13011194 (Exp: 08/31/2026) 407-404-4000

Inspection History

Type Request Date Result Inspector
HVAC FINAL 03/23/2026 APPROVED HCAMACHO
Note: 3/19/2026 - PREVIOUS INSPECTION NOTES 3/19/26: 1). Installed junits do not match Energy calcs model numbers. 2). secondary vertical cleanout pipe directly after running trap needs a cap 3). breakers in panel are not identified so I could not verify size. (ODU = Min.- 25amp / Max. -42 ----> AHU = Min.-3amp / Max. -15amp). Please mark AHU in attic with no heat strip or identify heat strip breaker size if one is installed.
MODEL HOME PARTIAL BUILDING FINAL 03/23/2026 APPROVED HCAMACHO
ROW - STORMWATER FINAL 03/20/2026 APPROVED FSLADISH
Note: 3/20/26 REQUIRED CORRECTIONS COMPLETED AT THE THIS INSPECTION. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ____________________________________________________________________________________________________________________________ 3/17/2026 - PREVIOUS INSPECTION NOTES 03-17-26 TPOLACEK*** AS STATED IN AFTER POUR INSPECTION THERE IS A SMALL AMOUNT OF CONCRETE IN FAR LEFT CULVERT THAT MUST BE REMOVED. ALL BARE AREAS IN THE REAR OF PROPERTY THAT BACKS UP TO COPC DITCH MUST HAVE SOD TO PREVENT WASHOUT AND EROSION *** INSPECTORS NOTE. BUILDER IS REQUIRED TO LAY SOD ON ALL BARE EARTH AREAS IN REAR JUST PAST PROPERTY LINE BEFORE ROW FINAL PASSAGE. ***
HVAC FINAL 03/19/2026 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 3/19/2026 9:51:10 AM *** 3/19/26: 1). Installed junits do not match Energy calcs model numbers. 2). secondary vertical cleanout pipe directly after running trap needs a cap 3). breakers in panel are not identified so I could not verify size. (ODU = Min.- 25amp / Max. -42 ----> AHU = Min.-3amp / Max. -15amp). Please mark AHU in attic with no heat strip or identify heat strip breaker size if one is installed.
HVAC FINAL 03/18/2026 CANCELLED BY INSPECTOR HCAMACHO
Note: Not required. Will check at Model Final. 3/10/2026 - PREVIOUS INSPECTION NOTES 3/10/26: Cancelled by Applicant in person at @ 1520.
U -UTILITY RESIDENTIAL FINAL 03/17/2026 FINAL APPROVED LFITZGERALD
ROW - STORMWATER FINAL 03/17/2026 Disapproved - NO FEE TPOLACEK
Note: 03-17-26 TPOLACEK*** AS STATED IN AFTER POUR INSPECTION THERE IS A SMALL AMOUNT OF CONCRETE IN FAR LEFT CULVERT THAT MUST BE REMOVED. ALL BARE AREAS IN THE REAR OF PROPERTY THAT BACKS UP TO COPC DITCH MUST HAVE SOD TO PREVENT WASHOUT AND EROSION *** INSPECTORS NOTE. BUILDER IS REQUIRED TO LAY SOD ON ALL BARE EARTH AREAS IN REAR JUST PAST PROPERTY LINE BEFORE ROW FINAL PASSAGE. ***
ROW - FINAL APRON (AFTER POUR) 03/17/2026 APPROVED - AS NOTED TPOLACEK
Note: 03-17-26 TPOLACEK*** APPROVING AS NOTED, THERE IS A SMALL AMOUNT OF CONCRETE CHUNKS IN FAR LEFT CULVERT THAT MUST BE REMOVED BEFORE FINAL ROW WILL BE APPROVED. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
U-CROSS CONNECTION 03/16/2026 APPROVED - AS NOTED BHAINES
Note: No CC, PVB in place
HVAC FINAL 03/10/2026 CANCELLED BY APPLICANT RSIMS
Note: *** NOTES ADDED BY RSIMS 3/10/2026 3:20:12 PM *** 3/10/26: Cancelled by Applicant in person at @ 1520.
ROW- FINAL SURVEY/GRADING CERTIFICATION 03/05/2026 APPROVED - AS NOTED FSLADISH
Note: 3/4/26 THIS INSPECTION IS FOR A MODEL HOME, IF/WHEN IT BECOMES A RESIDENCE A NEW SET OF PERMITS AND INSPECTIONS WILL BE REQUIRED.
ROW FIELD SURVEY /GRADING CERTIFICATION 03/05/2026 APPROVED FSLADISH
Note: 3/4/26 THIS INSPECTION IS FOR A MODEL HOME, IF/WHEN IT BECOMES A RESIDENCE A NEW SET OF PERMITS AND INSPECTIONS WILL BE REQUIRED. AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ______________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 3/4/26 THIS INSPECTION IS FOR A MODEL HOME, IF/WHEN IT BECOMES A RESIDENCE A NEW SET OF PERMITS AND INSPECTIONS WILL BE REQUIRED.
ROW- PRE-APRON (PRE-POUR) 02/23/2026 APPROVED FSLADISH
Note: 2/23/26 PIPE INVERTS ARE GOOD AT THIS INSPECTION. BUILDER REFER TO CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR BEFORE POURING. . IF FIBERGLASS OPTION IS USED, BUILDER REQUIRED TO USE 3000 PSI CONCRETE AT THE TIME OF THE INSPECTION READY TO POUR,IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK SITE FOR ANY STANDING WATER. ALSO VERIFY PIPE ELEVATION HAS NOT CHANGED. NO EXPANSION JOINTS ALLOWED, AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR.
ELECTRIC - EARLY POWER 02/23/2026 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 2/23/2026 10:18:42 AM *** 2/23/26: Mechanical Equipment located in the attic requires service outlet and switched light. Must be complete prior to Building Final Inspection. FBC-M1305.1.3.1 Electrical requirements. A luminaire controlled by a switch located at the required passageway opening and a receptacle outlet shall be installed at or near the appliance location in accordance with Section E3401.1. Exposed lamps shall be protected from damage by location or lamp guards. 2/19/2026 - PREVIOUS INSPECTION NOTES 2/19/26: Previously listed items 3 and 4 remain unresolved. Previously listed item 1 will be resolved at trim out. Item 1: Installer will move existing disconnect that is intended for the house ODU and install power (underground) from the main meter panel at trim out. 2). Bathroom 2: lights are not safed off. (feed wire is not safed off). NEC-110.27 3). Attic lights are not installed/safed off. NEC-110.27 (one attic light in the first opening and one equipment service light are required). 4). Front entry outlet is missing the (inside) cover. NEC-110.27 2/18/2026 - PREVIOUS INSPECTION NOTES 2/18/26: 1). Disconnect for Main house ODU is not installed (feed wire is not safed off). NEC-110.27 2). Bathroom 2: lights are not safed off. (feed wire is not safed off). NEC-110.27 3). Attic lights are not installed/safed off. NEC-110.27 4). Front entry outlet is missing the cover. NEC-110.27 Inspector Notes from Inspection 2200 *** NOTES ADDED BY RSIMS 1/7/2026 10:12:35 AM *** 1/7/26: FPL emailed > Approved for TUG.
ELECTRIC - EARLY POWER 02/19/2026 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 2/19/2026 12:01:31 PM *** 2/19/26: Previously listed items 3 and 4 remain unresolved. Previously listed item 1 will be resolved at trim out. Item 1: Installer will move existing disconnect that is intended for the house ODU and install power (underground) from the main meter panel at trim out. 2). Bathroom 2: lights are not safed off. (feed wire is not safed off). NEC-110.27 3). Attic lights are not installed/safed off. NEC-110.27 (one attic light in the first opening and one equipment service light are required). 4). Front entry outlet is missing the (inside) cover. NEC-110.27 2/18/2026 - PREVIOUS INSPECTION NOTES 2/18/26: 1). Disconnect for Main house ODU is not installed (feed wire is not safed off). NEC-110.27 2). Bathroom 2: lights are not safed off. (feed wire is not safed off). NEC-110.27 3). Attic lights are not installed/safed off. NEC-110.27 4). Front entry outlet is missing the cover. NEC-110.27 Inspector Notes from Inspection 2200 *** NOTES ADDED BY RSIMS 1/7/2026 10:12:35 AM *** 1/7/26: FPL emailed > Approved for TUG.
ELECTRIC - EARLY POWER 02/18/2026 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 2/18/2026 11:54:33 AM *** 2/18/26: 1). Disconnect for Main house ODU is not installed (feed wire is not safed off). NEC-110.27 2). Bathroom 2: lights are not safed off. (feed wire is not safed off). NEC-110.27 3). Attic lights are not installed/safed off. NEC-110.27 4). Front entry outlet is missing the cover. NEC-110.27 Inspector Notes from Inspection 2200 *** NOTES ADDED BY RSIMS 1/7/2026 10:12:35 AM *** 1/7/26: FPL emailed > Approved for TUG.
GRAVITY SEWER TEST 02/10/2026 APPROVED MCONTRYMAN
SEWER TIE IN 02/10/2026 APPROVED MCONTRYMAN
PEP TANK INSTALLATION REQUEST 02/02/2026 APPROVED BVITALE
Note: 1/30/2026 7:46:25 AM- PREVIOUS INSPECTION NOTES dumpster will need to move it is in the way
PEP TANK INSTALLATION REQUEST 01/27/2026 Disapproved -FEE REQUIRED CBOWERMASTER
Note: dumpster will need to move it is in the way
INSULATION 01/21/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 1/21/2026 9:49:43 AM *** 1/20/2026 - PREVIOUS INSPECTION NOTES 1/20/26: 1). Firestop missing at shower riser back right bathroom. FS written on stud. Also, please change white foam at other water line top plate penetration to firefoam. 2). right side hinged garage door is missing foam seal at the perimeter. 3). Garage Office walls: missing firestop > Horizontally at intervals not exceeding 10 feet (3048 mm). FBC-302.11.1.2 Please check all walls for firestop horizontal requirement. 1/15/2026 - PREVIOUS INSPECTION NOTES 1/15/26: Cancelled by Applicant via phone call at @ 1015.
INSULATION 01/20/2026 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 1/20/2026 10:25:52 AM *** 1/20/26: 1). Firestop missing at shower riser back right bathroom. FS written on stud. Also, please change white foam at other water line top plate penetration to firefoam. 2). right side hinged garage door is missing foam seal at the perimeter. 3). Garage Office walls: missing firestop > Horizontally at intervals not exceeding 10 feet (3048 mm). FBC-302.11.1.2 Please check all walls for firestop horizontal requirement. 1/15/2026 - PREVIOUS INSPECTION NOTES 1/15/26: Cancelled by Applicant via phone call at @ 1015.
INSULATION 01/15/2026 CANCELLED BY APPLICANT RSIMS
Note: *** NOTES ADDED BY RSIMS 1/15/2026 10:16:55 AM *** 1/15/26: Cancelled by Applicant via phone call at @ 1015.
LATH/BRICK/ WATER BARRIER 01/15/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 1/15/2026 10:15:18 AM *** 1/14/2026 - PREVIOUS INSPECTION NOTES 1/14/26: NOT READY! 1). no water barrier at front gable. FBC [A]107.4 2). Entry door on right side of entry. Lath is incomplete. FBC [A]107.4
LATH/BRICK/ WATER BARRIER 01/14/2026 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 1/14/2026 9:58:58 AM *** 1/14/26: NOT READY! 1). no water barrier at front gable. FBC [A]107.4 2). Entry door on right side of entry. Lath is incomplete. FBC [A]107.4
ALL ROUGH 01/12/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 1/12/2026 1:43:59 PM *** 1/6/2026 - PREVIOUS INSPECTION NOTES 1/6/26: 1). Duct layout in temporary office area do not match submitted Energy Calcs. FBC [A]107.4 2). Missing (wiring for) CM/SD detector outside of right side bedrooms. FBC-R315.1 3). No pressure gauge on water lines. FBCR P2503.7 4). 5ft. head pressure test not holding / not complete. FBC-P2503.5.1 5). All bathroom exhaust fans are missing the 2nd 'mechanical' (strap) connection. FBC-M1502.4.2 / FBC-M1601.4.1 / R806.1 6). Front entry door not installed. FBC [A]107.4 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 12/30/2025 1:59:29 PM *** 12/30/25: Check at All Rough. (walked with CM and framers). 1). Lateral bracing on truss webs shown in detail TB06. 2). Cross bracing betwenn trusses under front upper gable wall. 12/19/2025 - PREVIOUS INSPECTION NOTES 12/18/25: Spoke to Noah about specific Engineer required details that are still missing in the repair. This inspection on hold temporarily until he can have the Engineer review on site and make any necessary changes. 12/17/2025 - PREVIOUS INSPECTION NOTES 12/17/25: Incomplete inspection due to missing documents. 1).Missing Engineer's truss repair letter in box. (previously highlighted). Missing bracing/blocking shown in detail TB06 of engineer's letter. Missing detailed requirements as shown in Engineer's letter. Previously walked with ODC. 12/11/2025 - PREVIOUS INSPECTION NOTES 12/11/25: Please have highlighted engineer's letter / detail page returned to permit box (if possible). THIS WAS AN INFORMATIONAL INSPECTION ONLY. A FULL INSPEXCTION IS STILL REQUIRED. NOTE: ROOF SHEATHING APPROVED - OK TO INSTALL UNDERLAYMENT/DRIP EDGE AND PREP FOR ROOF VALLEY METAL INSPECTION. 12/8/2025 - PREVIOUS INSPECTION NOTES 12/8/25: Incomplete Inspection due to improper documents/plans. 1). Truss engineering packet is not stamped approved by the City as required and does not match the Manufacturer submitted to the City. FBC [A]107.3.1 / FBC [A]107.4. Also second truss pachage in permit box is for a different address. FBC [A]107.4 2). Front elevation corrections do not match Engineer's required repairs. Plans highlighted. FBC [A]107.4 3) Silt fence needs to be repaired and completed along the front left side to meet City requirements. FBC 3307.1 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 11/13/2025 2:49:38 PM *** 11/13/25: Must be resolved prior to next inspection. 1). Numerous Window Sill mortar beds and/or Concrete Block joints exceed the maximum thickness (sills - 1/2" / CMU joints - 3/8") per FBC-R606.3.1 Highlighted on plans. 2). Right side door lintel has excessive mortar joint above lintel. (3/8" max) FBC-R606.3.1 Highlighted on plans. 3). small garage: CMU on left side is overhanging footer excessively. FBC [A]107.4
ELECTRIC-TUG 01/07/2026 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 1/7/2026 10:12:35 AM *** 1/7/26: FPL emailed > Approved for TUG.
ALL ROUGH 01/06/2026 Disapproved -FEE REQUIRED RSIMS
Note: 1/6/26: 1). Duct layout in temporary office area do not match submitted Energy Calcs. FBC [A]107.4 2). Missing (wiring for) CM/SD detector outside of right side bedrooms. FBC-R315.1 3). No pressure gauge on water lines. FBCR P2503.7 4). 5ft. head pressure test not holding / not complete. FBC-P2503.5.1 5). All bathroom exhaust fans are missing the 2nd 'mechanical' (strap) connection. FBC-M1502.4.2 / FBC-M1601.4.1 / R806.1 6). Front entry door not installed. FBC [A]107.4 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 12/30/2025 1:59:29 PM *** 12/30/25: Check at All Rough. (walked with CM and framers). 1). Lateral bracing on truss webs shown in detail TB06. 2). Cross bracing betwenn trusses under front upper gable wall. 12/19/2025 - PREVIOUS INSPECTION NOTES 12/18/25: Spoke to Noah about specific Engineer required details that are still missing in the repair. This inspection on hold temporarily until he can have the Engineer review on site and make any necessary changes. 12/17/2025 - PREVIOUS INSPECTION NOTES 12/17/25: Incomplete inspection due to missing documents. 1).Missing Engineer's truss repair letter in box. (previously highlighted). Missing bracing/blocking shown in detail TB06 of engineer's letter. Missing detailed requirements as shown in Engineer's letter. Previously walked with ODC. 12/11/2025 - PREVIOUS INSPECTION NOTES 12/11/25: Please have highlighted engineer's letter / detail page returned to permit box (if possible). THIS WAS AN INFORMATIONAL INSPECTION ONLY. A FULL INSPEXCTION IS STILL REQUIRED. NOTE: ROOF SHEATHING APPROVED - OK TO INSTALL UNDERLAYMENT/DRIP EDGE AND PREP FOR ROOF VALLEY METAL INSPECTION. 12/8/2025 - PREVIOUS INSPECTION NOTES 12/8/25: Incomplete Inspection due to improper documents/plans. 1). Truss engineering packet is not stamped approved by the City as required and does not match the Manufacturer submitted to the City. FBC [A]107.3.1 / FBC [A]107.4. Also second truss pachage in permit box is for a different address. FBC [A]107.4 2). Front elevation corrections do not match Engineer's required repairs. Plans highlighted. FBC [A]107.4 3) Silt fence needs to be repaired and completed along the front left side to meet City requirements. FBC 3307.1 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 11/13/2025 2:49:38 PM *** 11/13/25: Must be resolved prior to next inspection. 1). Numerous Window Sill mortar beds and/or Concrete Block joints exceed the maximum thickness (sills - 1/2" / CMU joints - 3/8") per FBC-R606.3.1 Highlighted on plans. 2). Right side door lintel has excessive mortar joint above lintel. (3/8" max) FBC-R606.3.1 Highlighted on plans. 3). small garage: CMU on left side is overhanging footer excessively. FBC [A]107.4
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/30/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 12/30/2025 1:59:29 PM *** 12/30/25: Check at All Rough. (walked with CM and framers). 1). Lateral bracing on truss webs shown in detail TB06. 2). Cross bracing betwenn trusses under front upper gable wall. 12/19/2025 - PREVIOUS INSPECTION NOTES 12/18/25: Spoke to Noah about specific Engineer required details that are still missing in the repair. This inspection on hold temporarily until he can have the Engineer review on site and make any necessary changes. 12/17/2025 - PREVIOUS INSPECTION NOTES 12/17/25: Incomplete inspection due to missing documents. 1).Missing Engineer's truss repair letter in box. (previously highlighted). Missing bracing/blocking shown in detail TB06 of engineer's letter. Missing detailed requirements as shown in Engineer's letter. Previously walked with ODC. 12/11/2025 - PREVIOUS INSPECTION NOTES 12/11/25: Please have highlighted engineer's letter / detail page returned to permit box (if possible). THIS WAS AN INFORMATIONAL INSPECTION ONLY. A FULL INSPEXCTION IS STILL REQUIRED. NOTE: ROOF SHEATHING APPROVED - OK TO INSTALL UNDERLAYMENT/DRIP EDGE AND PREP FOR ROOF VALLEY METAL INSPECTION. 12/8/2025 - PREVIOUS INSPECTION NOTES 12/8/25: Incomplete Inspection due to improper documents/plans. 1). Truss engineering packet is not stamped approved by the City as required and does not match the Manufacturer submitted to the City. FBC [A]107.3.1 / FBC [A]107.4. Also second truss pachage in permit box is for a different address. FBC [A]107.4 2). Front elevation corrections do not match Engineer's required repairs. Plans highlighted. FBC [A]107.4 3) Silt fence needs to be repaired and completed along the front left side to meet City requirements. FBC 3307.1 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 11/13/2025 2:49:38 PM *** 11/13/25: Must be resolved prior to next inspection. 1). Numerous Window Sill mortar beds and/or Concrete Block joints exceed the maximum thickness (sills - 1/2" / CMU joints - 3/8") per FBC-R606.3.1 Highlighted on plans. 2). Right side door lintel has excessive mortar joint above lintel. (3/8" max) FBC-R606.3.1 Highlighted on plans. 3). small garage: CMU on left side is overhanging footer excessively. FBC [A]107.4
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/19/2025 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 12/19/2025 2:52:01 PM *** 12/18/25: Spoke to Noah about specific Engineer required details that are still missing in the repair. This inspection on hold temporarily until he can have the Engineer review on site and make any necessary changes. 12/17/2025 - PREVIOUS INSPECTION NOTES 12/17/25: Incomplete inspection due to missing documents. 1).Missing Engineer's truss repair letter in box. (previously highlighted). Missing bracing/blocking shown in detail TB06 of engineer's letter. Missing detailed requirements as shown in Engineer's letter. Previously walked with ODC. 12/11/2025 - PREVIOUS INSPECTION NOTES 12/11/25: Please have highlighted engineer's letter / detail page returned to permit box (if possible). THIS WAS AN INFORMATIONAL INSPECTION ONLY. A FULL INSPEXCTION IS STILL REQUIRED. NOTE: ROOF SHEATHING APPROVED - OK TO INSTALL UNDERLAYMENT/DRIP EDGE AND PREP FOR ROOF VALLEY METAL INSPECTION. 12/8/2025 - PREVIOUS INSPECTION NOTES 12/8/25: Incomplete Inspection due to improper documents/plans. 1). Truss engineering packet is not stamped approved by the City as required and does not match the Manufacturer submitted to the City. FBC [A]107.3.1 / FBC [A]107.4. Also second truss pachage in permit box is for a different address. FBC [A]107.4 2). Front elevation corrections do not match Engineer's required repairs. Plans highlighted. FBC [A]107.4 3) Silt fence needs to be repaired and completed along the front left side to meet City requirements. FBC 3307.1 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 11/13/2025 2:49:38 PM *** 11/13/25: Must be resolved prior to next inspection. 1). Numerous Window Sill mortar beds and/or Concrete Block joints exceed the maximum thickness (sills - 1/2" / CMU joints - 3/8") per FBC-R606.3.1 Highlighted on plans. 2). Right side door lintel has excessive mortar joint above lintel. (3/8" max) FBC-R606.3.1 Highlighted on plans. 3). small garage: CMU on left side is overhanging footer excessively. FBC [A]107.4
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/17/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 12/17/2025 2:22:21 PM *** 12/17/25: Incomplete inspection due to missing documents. 1).Missing Engineer's truss repair letter in box. (previously highlighted). Missing bracing/blocking shown in detail TB06 of engineer's letter. Missing detailed requirements as shown in Engineer's letter. Previously walked with ODC. 12/11/2025 - PREVIOUS INSPECTION NOTES 12/11/25: Please have highlighted engineer's letter / detail page returned to permit box (if possible). THIS WAS AN INFORMATIONAL INSPECTION ONLY. A FULL INSPEXCTION IS STILL REQUIRED. NOTE: ROOF SHEATHING APPROVED - OK TO INSTALL UNDERLAYMENT/DRIP EDGE AND PREP FOR ROOF VALLEY METAL INSPECTION. 12/8/2025 - PREVIOUS INSPECTION NOTES 12/8/25: Incomplete Inspection due to improper documents/plans. 1). Truss engineering packet is not stamped approved by the City as required and does not match the Manufacturer submitted to the City. FBC [A]107.3.1 / FBC [A]107.4. Also second truss pachage in permit box is for a different address. FBC [A]107.4 2). Front elevation corrections do not match Engineer's required repairs. Plans highlighted. FBC [A]107.4 3) Silt fence needs to be repaired and completed along the front left side to meet City requirements. FBC 3307.1 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 11/13/2025 2:49:38 PM *** 11/13/25: Must be resolved prior to next inspection. 1). Numerous Window Sill mortar beds and/or Concrete Block joints exceed the maximum thickness (sills - 1/2" / CMU joints - 3/8") per FBC-R606.3.1 Highlighted on plans. 2). Right side door lintel has excessive mortar joint above lintel. (3/8" max) FBC-R606.3.1 Highlighted on plans. 3). small garage: CMU on left side is overhanging footer excessively. FBC [A]107.4
ROOF SHEATHING 12/17/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 12/17/2025 2:10:43 PM *** 12/17/25: Roof sheathing checked and approved during initial inspection 2460. RS
ROOF VALLEY & METAL 12/17/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 12/17/2025 2:13:00 PM *** 12/17/25: This inspection is approved as noted due to no changes in roof sheathing layout/profile indicated in Engineer's truss repair letter submitted to and approved by the City. Truss repairs still need to be completed as required for inspection 2460.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/11/2025 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 12/11/2025 11:20:27 AM *** 12/11/25: Please have highlighted engineer's letter / detail page returned to permit box (if possible). THIS WAS AN INFORMATIONAL INSPECTION ONLY. A FULL INSPEXCTION IS STILL REQUIRED. NOTE: ROOF SHEATHING APPROVED - OK TO INSTALL UNDERLAYMENT/DRIP EDGE AND PREP FOR ROOF VALLEY METAL INSPECTION. 12/8/2025 - PREVIOUS INSPECTION NOTES 12/8/25: Incomplete Inspection due to improper documents/plans. 1). Truss engineering packet is not stamped approved by the City as required and does not match the Manufacturer submitted to the City. FBC [A]107.3.1 / FBC [A]107.4. Also second truss pachage in permit box is for a different address. FBC [A]107.4 2). Front elevation corrections do not match Engineer's required repairs. Plans highlighted. FBC [A]107.4 3) Silt fence needs to be repaired and completed along the front left side to meet City requirements. FBC 3307.1 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 11/13/2025 2:49:38 PM *** 11/13/25: Must be resolved prior to next inspection. 1). Numerous Window Sill mortar beds and/or Concrete Block joints exceed the maximum thickness (sills - 1/2" / CMU joints - 3/8") per FBC-R606.3.1 Highlighted on plans. 2). Right side door lintel has excessive mortar joint above lintel. (3/8" max) FBC-R606.3.1 Highlighted on plans. 3). small garage: CMU on left side is overhanging footer excessively. FBC [A]107.4
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/08/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 12/8/2025 1:32:55 PM *** 12/8/25: Incomplete Inspection due to improper documents/plans. 1). Truss engineering packet is not stamped approved by the City as required and does not match the Manufacturer submitted to the City. FBC [A]107.3.1 / FBC [A]107.4. Also second truss pachage in permit box is for a different address. FBC [A]107.4 2). Front elevation corrections do not match Engineer's required repairs. Plans highlighted. FBC [A]107.4 3) Silt fence needs to be repaired and completed along the front left side to meet City requirements. FBC 3307.1 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 11/13/2025 2:49:38 PM *** 11/13/25: Must be resolved prior to next inspection. 1). Numerous Window Sill mortar beds and/or Concrete Block joints exceed the maximum thickness (sills - 1/2" / CMU joints - 3/8") per FBC-R606.3.1 Highlighted on plans. 2). Right side door lintel has excessive mortar joint above lintel. (3/8" max) FBC-R606.3.1 Highlighted on plans. 3). small garage: CMU on left side is overhanging footer excessively. FBC [A]107.4
TIE BEAM / LINTEL 11/13/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 11/13/2025 2:49:38 PM *** 11/13/25: Must be resolved prior to next inspection. 1). Numerous Window Sill mortar beds and/or Concrete Block joints exceed the maximum thickness (sills - 1/2" / CMU joints - 3/8") per FBC-R606.3.1 Highlighted on plans. 2). Right side door lintel has excessive mortar joint above lintel. (3/8" max) FBC-R606.3.1 Highlighted on plans. 3). small garage: CMU on left side is overhanging footer excessively. FBC [A]107.4
MONOLITHIC SLAB 11/05/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 11/5/2025 10:53:51 AM *** 11/4/2025 - PREVIOUS INSPECTION NOTES 11/4/25: 1). Left side garage footer does not match plan requirements. Detail FM11 on page D1 as required on Foundation Plan page S1.0
ROW - DRAINAGE 11/05/2025 APPROVED FSLADISH
Note: 11/5/25 CORRECTIONS MADE AT THE TIME OF THIS INSPECTION. _______________________________________________________________________________________________________________________ 11/3/2025 - PREVIOUS INSPECTION NOTES 11-03-25 TPOLACEK*** RECIEVED INFO THAT LAST WEEK PORTA POTTY WAS DUMPED OVER IN SWALE. SANITATION CREW STOOD UP PORTA POTTY SO IT WASNT DUMPING ILLICIT DISCHARGE INTO SWALE. BUILDER NEEDS TO MOVE PORTA POTTY OUT OF SWALE. NEXT INSPECTION WED 11-05-25 .Inspector Notes from Inspection 9470 09-30-25 TPOLACEK*** SILT FENCE HAS BEEN INSTALLED AND SWALE IS OPEN. BUILDER MAY STILL NEED TO INSTALL TEMPORARY PIPE ONCE CONSTRUCTION BEGINS +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/29/2025 - PREVIOUS INSPECTION NOTES 09-29-25 TPOLACEK**** NO CHANGES TO SITE. BUILDER MUST INSTALL RESIDENTIAL CONSTRUCTION ENTRANCE AND SILT FENCE AS REQUIRED. 1 DAY FOR RE-INSPECTION BEFORE PERMIT IS PLACED ON HOLD. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/23/2025 - PREVIOUS INSPECTION NOTES 1) NEED TO INSTALL SILT FENCE AROUND THE ENTIRE SITE WITH A CONSTRUCTION ENTERANCE. 2) NEED TO OPEN SWALE AND CONSTRUCT ENTERANCE TO YOUR SITE WITH A TEMP. CULVERT. YOU WILL HAVE 5DAYS TO CORRECT ALL ISSUES OR THERE WILL BE A INSPECTION HOLD ON THE PERMIT.
MONOLITHIC SLAB 11/04/2025 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 11/4/2025 1:06:05 PM *** 11/4/25: 1). Left side garage footer does not match plan requirements. Detail FM11 on page D1 as required on Foundation Plan page S1.0
PROJECT STATUS (OFFICE USE) 11/03/2025 Status Check TPOLACEK
Note: 11-03-25 TPOLACEK*** BUILDER NEEDS TO MOVE PORTA POTTY OUT OF SWALE.
ROW - DRAINAGE 11/03/2025 Disapproved - NO FEE TPOLACEK
Note: 11-03-25 TPOLACEK*** RECIEVED INFO THAT LAST WEEK PORTA POTTY WAS DUMPED OVER IN SWALE. SANITATION CREW STOOD UP PORTA POTTY SO IT WASNT DUMPING ILLICIT DISCHARGE INTO SWALE. BUILDER NEEDS TO MOVE PORTA POTTY OUT OF SWALE. NEXT INSPECTION WED 11-05-25 .Inspector Notes from Inspection 9470 09-30-25 TPOLACEK*** SILT FENCE HAS BEEN INSTALLED AND SWALE IS OPEN. BUILDER MAY STILL NEED TO INSTALL TEMPORARY PIPE ONCE CONSTRUCTION BEGINS +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/29/2025 - PREVIOUS INSPECTION NOTES 09-29-25 TPOLACEK**** NO CHANGES TO SITE. BUILDER MUST INSTALL RESIDENTIAL CONSTRUCTION ENTRANCE AND SILT FENCE AS REQUIRED. 1 DAY FOR RE-INSPECTION BEFORE PERMIT IS PLACED ON HOLD. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/23/2025 - PREVIOUS INSPECTION NOTES 1) NEED TO INSTALL SILT FENCE AROUND THE ENTIRE SITE WITH A CONSTRUCTION ENTERANCE. 2) NEED TO OPEN SWALE AND CONSTRUCT ENTERANCE TO YOUR SITE WITH A TEMP. CULVERT. YOU WILL HAVE 5DAYS TO CORRECT ALL ISSUES OR THERE WILL BE A INSPECTION HOLD ON THE PERMIT.
PLUMBING 1ST ROUGH UNDERGROUND 10/31/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 10/31/2025 12:21:41 PM ***
FORMBOARD SURVEY (OFFICE USE ONLY) 10/30/2025 APPROVED RRICKS
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 10/23/2025 APPROVED JMUNSON
ROW - DRAINAGE 09/30/2025 APPROVED - AS NOTED TPOLACEK
Note: 09-30-25 TPOLACEK*** SILT FENCE HAS BEEN INSTALLED AND SWALE IS OPEN. BUILDER MAY STILL NEED TO INSTALL TEMPORARY PIPE ONCE CONSTRUCTION BEGINS +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/29/2025 - PREVIOUS INSPECTION NOTES 09-29-25 TPOLACEK**** NO CHANGES TO SITE. BUILDER MUST INSTALL RESIDENTIAL CONSTRUCTION ENTRANCE AND SILT FENCE AS REQUIRED. 1 DAY FOR RE-INSPECTION BEFORE PERMIT IS PLACED ON HOLD. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/23/2025 - PREVIOUS INSPECTION NOTES 1) NEED TO INSTALL SILT FENCE AROUND THE ENTIRE SITE WITH A CONSTRUCTION ENTERANCE. 2) NEED TO OPEN SWALE AND CONSTRUCT ENTERANCE TO YOUR SITE WITH A TEMP. CULVERT. YOU WILL HAVE 5DAYS TO CORRECT ALL ISSUES OR THERE WILL BE A INSPECTION HOLD ON THE PERMIT.
ROW - DRAINAGE 09/29/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 09-29-25 TPOLACEK**** NO CHANGES TO SITE. BUILDER MUST INSTALL RESIDENTIAL CONSTRUCTION ENTRANCE AND SILT FENCE AS REQUIRED. 1 DAY FOR RE-INSPECTION BEFORE PERMIT IS PLACED ON HOLD. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/23/2025 - PREVIOUS INSPECTION NOTES 1) NEED TO INSTALL SILT FENCE AROUND THE ENTIRE SITE WITH A CONSTRUCTION ENTERANCE. 2) NEED TO OPEN SWALE AND CONSTRUCT ENTERANCE TO YOUR SITE WITH A TEMP. CULVERT. YOU WILL HAVE 5DAYS TO CORRECT ALL ISSUES OR THERE WILL BE A INSPECTION HOLD ON THE PERMIT.
ROW - DRAINAGE 09/23/2025 Disapproved - NO FEE PFLANAGAN
Note: 1) NEED TO INSTALL SILT FENCE AROUND THE ENTIRE SITE WITH A CONSTRUCTION ENTERANCE. 2) NEED TO OPEN SWALE AND CONSTRUCT ENTERANCE TO YOUR SITE WITH A TEMP. CULVERT. YOU WILL HAVE 5DAYS TO CORRECT ALL ISSUES OR THERE WILL BE A INSPECTION HOLD ON THE PERMIT.
WATER METER INSTALLATION REQUEST 09/12/2025 APPROVED CBOWERMASTER
BLD - BUILDING FINAL
Note: 2/23/26: Mechanical Equipment located in the attic requires service outlet and switched light. Must be complete prior to Building Final Inspection. FBC-M1305.1.3.1 Electrical requirements. A luminaire controlled by a switch located at the required passageway opening and a receptacle outlet shall be installed at or near the appliance location in accordance with Section E3401.1. Exposed lamps shall be protected from damage by location or lamp guards.

Review History

Department Status Date In Date Out
MECH COMPLETE 03/19/2026 03/19/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH COMPLETE 01/09/2026 01/12/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 12/12/2025 12/16/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 12/12/2025 12/12/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC COMPLETE 12/04/2025 12/11/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 11/24/2025 12/01/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
ZON COMPLETE 10/27/2025 10/27/2025
Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM
SW1 COMPLETE 10/27/2025 10/30/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
BLD COMPLETE 10/22/2025 10/23/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SW1 COMPLETE 10/03/2025 10/03/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 10/03/2025 10/06/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ZON COMPLETE 10/03/2025 10/03/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SW1 HOLD 09/29/2025 09/30/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Asked to reject revised site plans by builder.
ENGIN1 HOLD 09/29/2025 09/30/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Asked to reject revised site plans by builder.
ZON COMPLETE 09/29/2025 09/29/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SWALE COMPLETE 09/24/2025 10/14/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
SW1 HOLD 09/23/2025 09/24/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Parren and I have spoken with Noah and we discussed submitting revised grading plan with an increased FFE and adjusting proposed elevations. There is no revised grading plan submitted at this time. Please submit revise grading plan for review.
ZON COMPLETE 09/23/2025 09/23/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 09/23/2025 09/25/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 HOLD 09/23/2025 09/29/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Parren and I have spoken with Noah and we discussed submitting revised grading plan with an increased FFE and adjusting proposed elevations. There is no revised grading plan submitted at this time. Please submit revise grading plan for review.
ZON COMPLETE 07/18/2025 07/18/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/14/2025 07/15/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
SW1 COMPLETE 07/14/2025 07/15/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON HOLD 07/14/2025 07/15/2025
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Landscape plan shows a tree in the driveway. Please correct landscape plan showing the magnolia on another location as this is your shade tree and it is required.
MECH COMPLETE 07/14/2025 07/15/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC COMPLETE 07/14/2025 07/18/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 07/14/2025 07/18/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
LOCATE COMPLETE 06/25/2025 06/26/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
BADMIN COMPLETE 06/12/2025 06/18/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD HOLD 06/12/2025 06/18/2025
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Truss layout from Manufacturer missing.
CUSVC COMPLETE 06/12/2025 06/26/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC HOLD 06/12/2025 06/18/2025
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need light switch for exterior lights by door in bed 5, construction office and by double doors by the offices. NEC 2020 210.70 (A) (2) 2. Need light switch by second main in entrance in bed 2. NEC 2020 210.70
ENGIN1 COMPLETE 06/12/2025 06/16/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 06/12/2025 06/17/2025
MECH HOLD 06/12/2025 06/17/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2023 8Th Edition
SW1 COMPLETE 06/12/2025 06/17/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
SWALE COMPLETE 06/12/2025 06/27/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ZON HOLD 06/12/2025 06/13/2025
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Model home: Code 1.Garage area Needs a regular garage door as you do not have offsite parking for the proposed glass doors, see code below: C.Duration of use. A residential dwelling unit may be used as a model for a maximum period of five years from the date the certificate of occupancy is issued. Any residential dwelling unit legally permitted as a model as of the effective date of this ordinance shall be permitted to remain as a model home until January 1, 2016. Permitted and prohibited activities. 1.A model home may be used for activities typical to an "open house" for sale, including tours by a real estate agent and negotiation or execution of sales contracts for the sale of that builder's homes or products.2.A model home shall not:a.Be used as a primary or secondary office for a homebuilder or real estate agent with regard to conducting business activities outside of those permitted above.b.Be used for storage of building materials.3.The garage of the model home may be used as an office for sales staff if separate off-street parking is provided.4.The garage must be equipped with a standard garage door, unless dedicated off-site parking is provided, excluding rights-of-ways.5.If the space for the required garage has been converted to space for purposes other than a garage, the space must be converted back to a residential garage and equipped with a standard garage door prior to the sale and use as a dwelling unit. 2.you will need to provide a Single Family affadavit for room 5 3.Need to create an entrance to the main home from room 5 as this is not a duplex home and can not be closed off to the main home. 4. Landscape plan is missing 8 foundation planting along the front of the home.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 03/20/2026
REINSPECTION RESIDENTIAL ¤40.00 03/12/2026
REINSPECTION RESIDENTIAL ¤40.00 03/12/2026
REINSPECTION RESIDENTIAL ¤40.00 03/12/2026
REINSPECTION RESIDENTIAL ¤40.00 03/12/2026
REINSPECTION RESIDENTIAL ¤40.00 03/12/2026
REINSPECTION RESIDENTIAL ¤40.00 03/12/2026
REINSPECTION RESIDENTIAL ¤40.00 03/12/2026
RSI REINSPECTION 1 ¤35.00 03/12/2026
RSI REINSPECTION 1 ¤35.00 03/12/2026
SW ENG - INSPECTION 20 ¤20.00 03/12/2026
SW ENG - INSPECTION 20 ¤20.00 03/12/2026
SW ENG - INSPECTION 20 ¤20.00 03/12/2026
UTILITY PEP REINSPECTION ¤40.00 03/12/2026
PLAN REVIEW - REVISION ¤32.50 03/12/2026
SEWER CREDIT (¤5,468.40) 08/27/2025
WASTEWATER PERM INSPECTION ¤80.00 08/27/2025
WASTEWATER PERM REVIEW ¤25.00 08/27/2025
SEWER CAPITAL FACILITY ¤4,415.00 08/27/2025
WATER CREDIT (¤19.37) 08/27/2025
WATER CAPITAL FACILITY FEE ¤3,790.49 08/27/2025
WATER PERMIT REVIEW ¤25.00 08/27/2025
WATER MAIN EXTENSION IMPACT ¤917.27 08/27/2025
SITE PLAN 30 ¤30.00 08/27/2025
SW ENG INSPECTION 80 ¤80.00 08/27/2025
SW ENG PRE APRON ¤30.00 08/27/2025
SW ENG - REVIEW 20 ¤20.00 08/27/2025
SW ENG RES REVIEW 200 ¤200.00 08/27/2025
WATER METER W/ TAP ¤2,326.93 08/27/2025
WASTEWATER MAIN EXTENSION IMPA ¤2,385.00 08/27/2025
SURCHARGE FS 533.721 ¤13.23 08/27/2025
SURCHARGE - FS 468.631 ¤19.85 08/27/2025
SW ENG - FOUNDATION SURVEY ¤20.00 08/27/2025
WATER- TURN ON ¤50.00 08/27/2025
ADJUSTMENT 10% (¤147.02) 08/27/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 08/27/2025
INSPECTION - RESIDENTIAL ¤1,122.00 08/27/2025
PLAN REVIEW - RESIDENTIAL ¤318.24 08/27/2025
FC IMPACT FEE EMS ¤62.00 08/27/2025
IMPACT FEE FIRE ¤434.51 08/27/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 08/27/2025
FC IMPACT FEE LIBRARY ¤268.00 08/27/2025
IMPACT FEE PARKS ¤1,828.01 08/27/2025
IMPACT FEE SCHOOL ¤5,450.00 08/27/2025
IMPACT FEE TRANSPORTATION ¤1,916.00 08/27/2025
PEP TANK INSTALL ¤756.74 08/27/2025
Fees Total Due: ¤0.00 Total Paid: ¤21,711.48