Permit #2025060657

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7026-00430-0260
Block: 00430
Subdivision: 7026 -
Job Phone: 305-525-3466
Location Address: 42 PILGRIM DR
Type: ME - MECHANICAL
Issue Date: 06/16/2025
NOC: Unknown
Applicant name: MICHAEL J PERTIERRA
Owner: URENA AMNERIS & JUAN EMILIO H&W

Address

1770 BRUCKNER BLVD

BRONX, NY 10473

Address

APT 12G

BRONX, NY 10473

Lot: 0260
Contracted Stated Job Value: ¤5,900.00
Job Description: 2.5Ton /14.5 Seer2
Type: CN

Contractor

MIAMI COOL, INC
Status Location Address State License Number Phone
INACTIVE

12223 SW 133 CT

MIAMI, FL 33186

CAC1817122 (Exp: 08/31/2026) 305-525-3466

Inspection History

Type Request Date Result Inspector
HVAC FINAL 07/08/2025 FINAL APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 7/8/2025 10:04:41 AM *** 7/7/2025 - PREVIOUS INSPECTION NOTES 7/7/25: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. If requesting a Virtual Re-inspection, please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed. (Pictures are not approved). 1). AHU closet: Disconnect is missing cover door. (disconnect will need to repaired or replaced). NEC110.26 2). MC conduit needs to be secured to the wall within 12" of disconnect enclosure as required. NEC-334.30 3). Supply duct must be sealed fully with approved material where it passes through ceiling into the attic. FBC-M1601.1.1.7.4
HVAC FINAL 07/07/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 7/7/2025 12:44:06 PM *** 7/7/25: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. If requesting a Virtual Re-inspection, please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed. (Pictures are not approved). 1). AHU closet: Disconnect is missing cover door. (disconnect will need to repaired or replaced). NEC110.26 2). MC conduit needs to be secured to the wall within 12" of disconnect enclosure as required. NEC-334.30 3). Supply duct must be sealed fully with approved material where it passes through ceiling into the attic. FBC-M1601.1.1.7.4

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 07/07/2025
SURCHARGE FS 533.721 ¤2.00 06/16/2025
SURCHARGE - FS 468.631 ¤2.00 06/16/2025
ADJUSTMENT 10% (¤9.00) 06/16/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 06/16/2025
INSPECTION - MECHANICAL ¤60.00 06/16/2025
Fees Total Due: ¤0.00 Total Paid: ¤125.00