I want to search for...
Permit #2025060658
Permit Details
Status: INSPECT
| Parcel Id: 07-11-31-7015-00030-0040 |
| Block: 00030 |
| Subdivision: 7015 - |
| Job Phone: 386-283-7851 |
| Location Address: 97 CIMMARON DR |
| Type: DR - DRIVEWAY |
| Issue Date: 07/23/2025 |
| NOC: RECORDED |
| Applicant name: MICHAEL MENENDEZ |
| Owner: MAGIDOW STEPHEN LOUIS & ANN-SOFIE H&W TRUSTEES |
|
Address 97 CIMMARON DRIVE PALM COAST, FL 32137 |
| Lot: 0040 |
| Contracted Stated Job Value: ¤25,000.00 |
| Job Description: PAVER DRIVEWAY AND ADD 60X16 CIRCULAR DRIVE WAY EXTENSION |
| Type: CN |
Contractor
ROYAL CONSTRUCTION INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
211 S COOPERS HAWK WAY PALM COAST, FL 32164 |
RB29003957 (Exp: 08/31/2027) | 386-283-7851 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - FINAL INSPECTION | 01/23/2026 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: *** NOTES ADDED BY TPOLACEK 1/23/2026 9:12:28 AM *** * RESIDENTIAL CONCRETE DRIVEWAY CULVERT DETAIL. DRAWING 300. E 14. CONCRETE EXTENDING BEYOND THE FORMBOARDS, INTO THE SWALE, MUST BE REMOVED.Sec 300.E * RESIDENTIAL CONCRETE DRIVEWAY CULVERT DETAIL. DRAWING 300. E 12. ALL DISTURBED AREAS SHALL BE STABILIZED WITH SOD.Sec 300.E * SWALE PROFILE / RESIDENTIAL SWALE PROFILE DRAWING 300.D 11)5 FOOT UTILITY/DRAINAGE EASMENT. USE AS NECESSARY TO MAINTAIN A MAXIMUM OF 4 TO 1 SLOPE 01-23-26 TPOLACEK*** SWALE DAMAGE HAS NOT BEEN REPAIRED, ALL OVER POUR CONCRETE STUCK TO INSIDE OF CULVERT MUST BE CHIPPED OFF, ALL SEDIMENT REMOVED FROM CULVERTS. SWALE MUST BE GRADED TO MATCH TYPICAL RESIDENTIAL SWALE PLAN DETAIL. 8/21/2025 - PREVIOUS INSPECTION NOTES ** BUILDER NEEDS TO SOD SWALE ON RIGHT SIDE WHERE WATER WAS HELD THAT KILLED GRASS ON ADJACENT PROPERTY AND FINISH SODDING SWALE MATCHING EXISTING GRADE ** SEE ATTACHED PHOTOS | |||
| U -UTILITY RESIDENTIAL FINAL | 01/23/2026 | FINAL APPROVED | BWRIGHT |
| ROW - FINAL INSPECTION | 08/21/2025 | Disapproved - NO FEE | EMADISON |
| Note: ** BUILDER NEEDS TO SOD SWALE ON RIGHT SIDE WHERE WATER WAS HELD THAT KILLED GRASS ON ADJACENT PROPERTY AND FINISH SODDING SWALE MATCHING EXISTING GRADE ** SEE ATTACHED PHOTOS | |||
| ROW - FINAL APRON (AFTER POUR) | 08/21/2025 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 08/21/25 BUILDERNEEDS TO CLEAR CULVERT ENDS OF SEDIMENT AND OVER POURED CONCRETE AND DEBRIS SO PROPER ELEVATION CAN BE CHECKED FOR INSPECTION | |||
| ROW- PRE-APRON (PRE-POUR) | 08/01/2025 | APPROVED | PFLANAGAN |
| Note: READY TO LAY THE PAVERS SEE NOTE ON AFTER POUR ON WHY THE FIRST PRE POUR WAS PASS ALL THE WAY | |||
| ROW - FINAL APRON (AFTER POUR) | 08/01/2025 | CANCELLED BY APPLICANT | PFLANAGAN |
| Note: THIS IS THE WRONG INSPECTION I PASSED AS NOTED THE FIRST INSPECTION SINCE THIS WAS A PAVER DRIVEWAY NEEDED TO BE ANOTHER PRE POUR PUTTING ON PRE POUR SO THIS INSPECTION WILL BE AFTER PAVERS ARE SET. ------------------------------------------------------------------------ | |||
| ROW- PRE-APRON (PRE-POUR) | 07/28/2025 | APPROVED - AS NOTED | PFLANAGAN |
| Note: PASSING AS NOTED TALKED WITH CONTRACTOR THAT HE WILL TAKE CARE OF THE SOFT SOIL ON RIGHT CULVERT PIPE AREA. IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. -------------------------------------------------------------------------- 7/24/2025 - PREVIOUS INSPECTION NOTES ** 07/24/25 SITE NOT READY FOR INSPECTION TOO MUCH WATER IN POUR AREA PIPES ARE FULL OF WATER ** MATERIAL IN APRON AND AROUND CULVERT IS TO SOFT AND WET ** SEE ATTACHED PHOTOS | |||
| ROW- PRE-APRON (PRE-POUR) | 07/24/2025 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 07/24/25 SITE NOT READY FOR INSPECTION TOO MUCH WATER IN POUR AREA PIPES ARE FULL OF WATER ** MATERIAL IN APRON AND AROUND CULVERT IS TO SOFT AND WET ** SEE ATTACHED PHOTOS | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| Note: 8/21/2025 - PREVIOUS INSPECTION NOTES ** 08/21/25 BUILDERNEEDS TO CLEAR CULVERT ENDS OF SEDIMENT AND OVER POURED CONCRETE AND DEBRIS SO PROPER ELEVATION CAN BE CHECKED FOR INSPECTION | |||
| ROW - FINAL INSPECTION | |||
| Note: 1/23/2026 - PREVIOUS INSPECTION NOTES 01-23-26 TPOLACEK*** SWALE DAMAGE HAS NOT BEEN REPAIRED, ALL OVER POUR CONCRETE STUCK TO INSIDE OF CULVERT MUST BE CHIPPED OFF, ALL SEDIMENT REMOVED FROM CULVERTS. SWALE MUST BE GRADED TO MATCH TYPICAL RESIDENTIAL SWALE PLAN DETAIL. 8/21/2025 - PREVIOUS INSPECTION NOTES ** BUILDER NEEDS TO SOD SWALE ON RIGHT SIDE WHERE WATER WAS HELD THAT KILLED GRASS ON ADJACENT PROPERTY AND FINISH SODDING SWALE MATCHING EXISTING GRADE ** SEE ATTACHED PHOTOS |
Review History
| Department | Status | Date In | Date Out |
| ZON | HOLD | 07/07/2025 | 07/07/2025 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM REPEAT COMMENT: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM The Agreement is still not filled out correctly. This is a legal document that will be recorded and must be correct. It needs to read: Stephen Louis Magidow and Ann-Sofie Magidow as Trustees of the Stephen Louis Magidow and Ann-Sofie Magidow Living Trust dated JUNE 16, 2021. 7/7/25 - PLEASE ADD THE WORD "LIVING" BEFORE THE WORD TRUST - JUST AS IS SHOWN ON THE TRUST. THIS MUST BE ADDED IN ALL AREAS OF THE DOCUMENT WHERE THE NAME OF THE TRUST IS LISTED. ONCE THIS HAS BEEN CORRECTED, PLEASE SUBMIT THE ORIGINAL DOCUMENT. | |||
| ZON | COMPLETE | 07/07/2025 | 07/07/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ZON | HOLD | 07/01/2025 | 07/02/2025 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM The Agreement is still not filled out correctly. This is a legal document that will be recorded and must be correct. It needs to read: Stephen Louis Magidow and Ann-Sofie Magidow as Trustees of the Stephen Louis Magidow and Ann-Sofie Magidow Living Trust dated JUNE 16, 2021. 7/2/25 - PLEASE ADD THE WORD "LIVING" BEFORE THE WORD TRUST - JUST AS IS SHOWN ON THE TRUST. THIS MUST BE ADDED IN ALL AREAS OF THE DOCUMENT WHERE THE NAME OF THE TRUST IS LISTED. ONCE THIS HAS BEEN CORRECTED, PLEASE SUBMIT THE ORIGINAL DOCUMENT. | |||
| UTL | COMPLETE | 06/27/2025 | 06/27/2025 |
| Note: Released By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM | |||
| ZON | HOLD | 06/27/2025 | 06/27/2025 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM The License Agreement is still not filled out correctly. This is a legal document that will be recorded and must be correct. It needs to read: Stephen Louis Magidow and Ann-Sofie Magidow as Trustees of the Stephen Louis Magidow and Ann-Sofie Magidow Living Trust dated JUNE 16, 2021 (THIS IS THE DATE OF THE TRUST - NOT THE DATE THE DOCUMENT IS SIGNED.) ALL SIGNATURE LINES MUST BE FILLED OUT EXACTLY LIKE THIS AND THE NOTARY SECTION AS WELL. | |||
| ENGIN1 | COMPLETE | 06/27/2025 | 06/27/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 06/17/2025 | 06/30/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| ENGIN1 | HOLD | 06/16/2025 | 06/17/2025 |
| Note: Held By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM Need to show the size and type of culverts that will be installed. Culverts must be a 15" equivalent made of CMP or HDPE. | |||
| UTL | HOLD | 06/16/2025 | 06/25/2025 |
| Note: Held By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM SEE ZONING COMMENTS | |||
| ZON | HOLD | 06/16/2025 | 06/16/2025 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM 1. This property is deeded in a Trust. Please submit the correct Right of Way Utilization Agreement for properties deeded in a trust and be sure it is filled out, signed and notarized correctly and then submit an electronic copy for staff review again. 2. Unable to read the width of the existing driveway that is being replaced. Please show clear dimension on site plan. 3. The botttom edge of the circular driveway must be a minimum of 5' from the front property line, which must be shown on the side plan. Please note that the front property line is the darkest, thickest line on the site plan. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 10% | (¤3.00) | 07/23/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 07/23/2025 |
| RECORDING FEE REIMBURSE DOC | ¤44.00 | 07/23/2025 |
| SW ENG INSPECTION 40 | ¤40.00 | 07/23/2025 |
| SW ENG PRE APRON | ¤30.00 | 07/23/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 07/23/2025 |
| SITE PLAN 15 | ¤15.00 | 07/23/2025 |
| SW ENG REINSPECTION 20 | ¤20.00 | |
| SW ENG REINSPECTION 30 | ¤30.00 | |
| RSI REINSPECTION 1 | ¤35.00 | |
| Fees | Total Due: ¤85.00 | Total Paid: ¤356.00 |