I want to search for...

Permit #2025060775

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7024-00340-0170
Block: 00340
Subdivision: 7024 -
Job Phone: 386-302-7838
Location Address: 21 PRESTON LN
Type: EL - ELECTRICAL
Issue Date: 07/07/2025
NOC: RECORDED
Applicant name: MISHA ROMANOVSKIY
Owner: 21 PRESTON LN LAND TRUST

Address

3225 MCLEOD DRIVE

LAS VEGAS, NV 89121

Lot: 0170
Contracted Stated Job Value: ¤34,000.00
Job Description: Replace 200A panel add outside DC, rewire portion that was damaged by lightning
Type: CN

Contractor

NORTH STAR ELECTRIC LLC
Status Location Address State License Number Phone Fax
ACTIVE

77 PEBBLE BEACH DRIVE

PALM COAST, FL 32164

EC13013595 (Exp: 08/31/2026) 386-793-5553 386-961-4388

Inspection History

Type Request Date Result Inspector
ELECTRIC FINAL 01/15/2026 FINAL APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 1/15/2026 11:26:03 AM *** 12/9/2025 - PREVIOUS INSPECTION NOTES 12/9/25 1. Per previos notes final inspection will be required where all devices, GFCI circuits NEC 210.8 , smoke alarms and HVAC circuits are checked/inspected. as well as arc faults where required per NEC 210.12 2. Smoke detectors are required in each bed room and outside each bedroom with in 10'. Smokes can also not be with in 3' of fan blades or a/c supply registers FBCR 314 & 315 3. Drive ground rods flush with ground NEC 250.53(A)(4) 4. Face cover plate on garage door outlet missing NEC 110.26 5. Disconnect for ODU can not be beind unit must have 3' of clear working space NEC 110.26 7/21/25 This is a partial inspection as requested by the Applicant for the new meter panel, Adjacent 200amp main disconnect panel and breaker panel. Due to the impact of the lightning strike on interior wiring and devices, a full electrical (only) final inspection will be required where all devices, GFCI circuits, smoke alarms and HVAC circuits are checked/inspected.
ELECTRIC FINAL 12/09/2025 Disapproved - NO FEE MKRASKI
Note: 12/9/25 1. Per previos notes final inspection will be required where all devices, GFCI circuits NEC 210.8 , smoke alarms and HVAC circuits are checked/inspected. as well as arc faults where required per NEC 210.12 2. Smoke detectors are required in each bed room and outside each bedroom with in 10'. Smokes can also not be with in 3' of fan blades or a/c supply registers FBCR 314 & 315 3. Drive ground rods flush with ground NEC 250.53(A)(4) 4. Face cover plate on garage door outlet missing NEC 110.26 5. Disconnect for ODU can not be beind unit must have 3' of clear working space NEC 110.26 7/21/25 This is a partial inspection as requested by the Applicant for the new meter panel, Adjacent 200amp main disconnect panel and breaker panel. Due to the impact of the lightning strike on interior wiring and devices, a full electrical (only) final inspection will be required where all devices, GFCI circuits, smoke alarms and HVAC circuits are checked/inspected.
ELECTRIC - EARLY POWER 07/28/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 7/28/2025 3:19:48 PM *** 7/28/25: Ready for Meter Install. Approved
ELECTRIC FINAL 07/21/2025 PARTIALLY APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 7/21/2025 2:55:09 PM *** 7/21/25: This is a partial inspection as requested by the Applicant for the new meter panel, Adjacent 200amp main disconnect panel and breaker panel. Due to the impact of the lightning strike on interior wiring and devices, a full electrical (only) final inspection will be required where all devices, GFCI circuits, smoke alarms and HVAC circuits are checked/inspected.

Review History

Department Status Date In Date Out
BADMIN INFORMATION 07/18/2025 07/18/2025
Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM RENAME FILE NAME TO NOC.PDF
BADMIN COMPLETE 07/02/2025 07/02/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ELEC COMPLETE 06/17/2025 06/18/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BADMIN HOLD 06/17/2025 06/17/2025
Note: Held By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM need a construction lein law

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 10% (¤12.25) 07/07/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 07/07/2025
INSPECTION- ELECTRICAL ¤60.00 07/07/2025
PLAN REVIEW - MISC 32.50 ¤32.50 07/07/2025
SURCHARGE FS 533.721 ¤2.00 07/07/2025
SURCHARGE - FS 468.631 ¤2.00 07/07/2025
Fees Total Due: ¤0.00 Total Paid: ¤114.25