I want to search for...
Permit #2025060794
Permit Details
Status: COED
| Parcel Id: 07-11-31-7024-00410-0320 |
| CONDITIONED SPACE: 1809 sqft |
| GARAGE: 406 sqft |
| OPENED PORCH (WITH ROOF) : 33 sqft |
| Total Square Footage: 2248 sqft |
| Block: 00410 |
| Subdivision: - |
| Job Phone: 239-571-5325 |
| Location Address: 40 PRESIDENT LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 08/04/2025 |
| NOC: RECORDED |
| Applicant name: RYAN SCOTT DAVIS |
| Owner: SYNERGY HOMES LLC |
|
Address 581 NW MERCANTILE PLACE 106 PORT SAINT LUCIE, FL 34986 |
| Lot: 0320 |
| Contracted Stated Job Value: ¤200,000.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
SYNERGY HOMES, LLC
| Status | Location Address | State License Number |
| ACTIVE |
1 HARGROVE GRADE, SUITE B1 PALM COAST, FL 32137 |
CBC1254289 (Exp: 08/31/2026) |
Sub Contractors
TERRY BRICE DICKERSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4300 ST JOHN'S PARKWAY ALPHARETTA, GA 30009 |
CCC1326209 (Exp: 08/31/2026) | 407-548-6733 |
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
MICHAEL FRANK MORELLO
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2 HARGROVE GRADE PALM COAST, FL 32164 |
CAC1819466 (Exp: 08/31/2026) | 386-445-5023 | 386-446-4614 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 12/18/2025 | FINAL APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 12/18/2025 3:02:48 PM *** 12/16/2025 - PREVIOUS INSPECTION NOTES 12/16/25: 1). Garage door buck bolts are cut off at top on both sides of door. FBC [A]107.4 2). Master bathroom: shower stall is not sealed along the sill where the floor meets. (and at corners of sill) as required. FBC-P2705.1(3) 3). Guest bathroom: bathtub is not sealed along the front apron as required. FBC-P2705.1(3) 4). Garage door opener is not plugged in and safety eyes are still covered with plastic. Could not test. FBC-[A] 110.1 5). Garage ceiling has holes that need be sealed with approved material FBC- R302.11(4). 6). Front entry door and interior garage door are missing seals at perimeter. FBC EC TABLE R402.4.1.1 7). Pop-up assemblies in Master Bathroom are not working as required. (will not hold water). FBC-419.3 / FBC-P2711.3 | |||
| BLD - BUILDING FINAL | 12/16/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 12/16/2025 12:10:55 PM *** 12/16/25: 1). Garage door buck bolts are cut off at top on both sides of door. FBC [A]107.4 2). Master bathroom: shower stall is not sealed along the sill where the floor meets. (and at corners of sill) as required. FBC-P2705.1(3) 3). Guest bathroom: bathtub is not sealed along the front apron as required. FBC-P2705.1(3) 4). Garage door opener is not plugged in and safety eyes are still covered with plastic. Could not test. FBC-[A] 110.1 5). Garage ceiling has holes that need be sealed with approved material FBC- R302.11(4). 6). Front entry door and interior garage door are missing seals at perimeter. FBC EC TABLE R402.4.1.1 7). Pop-up assemblies in Master Bathroom are not working as required. (will not hold water). FBC-419.3 / FBC-P2711.3 | |||
| U -UTILITY RESIDENTIAL FINAL | 12/15/2025 | FINAL APPROVED | BHAINES |
| Note: Inspector Notes from Inspection 9035 NO IRR/NO CC | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/12/2025 | APPROVED | TPOLACEK |
| Note: 12/11/2025 - PREVIOUS INSPECTION NOTES 12/11/25 YOUR LEFT REAR CORNER SHOWS FLAT AND WATER SITTING INTO LEFT NEIGHBORING LOT. SEE PHOTO FOR REFERENCE. REAR YARD DRAIAGE Section 300.01 C(6) V-16 "6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement." POSITIVE FALL .10 EVERY 20 FT. Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 fee | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 12/12/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - STORMWATER FINAL | 12/12/2025 | APPROVED - AS NOTED | TPOLACEK |
| Note: 12-12-25 TPOLACEK*** SMALL AMOUNT OF TRASH NEEDS TO BE CLEANED UP BUT I WILL APPROVE AS NOTED. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - FINAL APRON (AFTER POUR) | 12/12/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/11/2025 | Disapproved - NO FEE | FSLADISH |
| Note: 12/11/25 YOUR LEFT REAR CORNER SHOWS FLAT AND WATER SITTING INTO LEFT NEIGHBORING LOT. SEE PHOTO FOR REFERENCE. REAR YARD DRAIAGE Section 300.01 C(6) V-16 "6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement." POSITIVE FALL .10 EVERY 20 FT. Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 fee | |||
| ELECTRIC - EARLY POWER | 12/09/2025 | APPROVED - AS NOTED | MKRASKI |
| Note: Emailed FPL @ 10:05am | |||
| ELECTRIC - EARLY POWER | 12/08/2025 | CANCELLED BY APPLICANT | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 12/8/2025 2:28:16 PM *** 12/8/25: Cancelled by Applicant on phone at @ 1020. | |||
| U-CROSS CONNECTION | 12/08/2025 | APPROVED - AS NOTED | BWRIGHT |
| Note: NO IRR/NO CC | |||
| ROW- PRE-APRON (PRE-POUR) | 12/03/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. 12/2/2025 - PREVIOUS INSPECTION NOTES 12-2-25 TPOLACEK*** THERE IS NOT 4" THROUGHOUT THE UPPER PORTION, FORMBOARDS ARE DOWN IN TWO SPOTS, THERE IS NOT 2" OVER MITER END, THERE IS NOT 5" OVER LEFT SIDE PIPE AND THE APRON SLOPE EXCEEDS 8% PLEASE MAKE FORM BOARD CORRECTIONS BEFORE REQUESTING ANOTHER INSPECTION. | |||
| ROW- PRE-APRON (PRE-POUR) | 12/02/2025 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 12-2-25 TPOLACEK*** THERE IS NOT 4" THROUGHOUT THE UPPER PORTION, FORMBOARDS ARE DOWN IN TWO SPOTS, THERE IS NOT 2" OVER MITER END, THERE IS NOT 5" OVER LEFT SIDE PIPE AND THE APRON SLOPE EXCEEDS 8% PLEASE MAKE FORM BOARD CORRECTIONS BEFORE REQUESTING ANOTHER INSPECTION. | |||
| INSULATION | 11/26/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/26/2025 1:53:57 PM *** Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 11/24/2025 11:33:23 AM *** 11/24/25: 1). Silt fence needs to be repaired on right side and along front. FBC 3307.1 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 11/14/2025 12:08:01 PM *** 11/14/25: 1). Please fix silt fence and keep it maintained. FBC 3307.1 2). Please have permit box that is laying on the ground remounted in the ground to maintain plan integrity. FBC [A]107.3.1 11/13/2025 - PREVIOUS INSPECTION NOTES 11/13/25: Cancelled by Applicant via text at @ 0718. | |||
| LATH/BRICK/ WATER BARRIER | 11/26/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/26/2025 1:54:14 PM *** Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 11/24/2025 11:33:23 AM *** 11/24/25: 1). Silt fence needs to be repaired on right side and along front. FBC 3307.1 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 11/14/2025 12:08:01 PM *** 11/14/25: 1). Please fix silt fence and keep it maintained. FBC 3307.1 2). Please have permit box that is laying on the ground remounted in the ground to maintain plan integrity. FBC [A]107.3.1 11/13/2025 - PREVIOUS INSPECTION NOTES 11/13/25: Cancelled by Applicant via text at @ 0718. | |||
| LATH/BRICK/ WATER BARRIER | 11/24/2025 | CANCELLED BY APPLICANT | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/24/2025 11:32:13 AM *** 11/24/25: Cancelled by Applicant via phone call at @ 1130. Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 11/14/2025 12:08:01 PM *** 11/14/25: 1). Please fix silt fence and keep it maintained. FBC 3307.1 2). Please have permit box that is laying on the ground remounted in the ground to maintain plan integrity. FBC [A]107.3.1 11/13/2025 - PREVIOUS INSPECTION NOTES 11/13/25: Cancelled by Applicant via text at @ 0718. | |||
| ALL ROUGH | 11/24/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/24/2025 11:33:23 AM *** 11/24/25: 1). Silt fence needs to be repaired on right side and along front. FBC 3307.1 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 11/14/2025 12:08:01 PM *** 11/14/25: 1). Please fix silt fence and keep it maintained. FBC 3307.1 2). Please have permit box that is laying on the ground remounted in the ground to maintain plan integrity. FBC [A]107.3.1 11/13/2025 - PREVIOUS INSPECTION NOTES 11/13/25: Cancelled by Applicant via text at @ 0718. | |||
| WALL SHEATHING | 11/14/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/14/2025 11:31:57 AM *** 11/13/2025 - PREVIOUS INSPECTION NOTES 11/13/25: Cancelled by Applicant via text at @ 0718. | |||
| ROOF VALLEY & METAL | 11/14/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/14/2025 12:03:00 PM *** 11/13/2025 - PREVIOUS INSPECTION NOTES 11/13/25: Cancelled by Applicant via text at @ 0718. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/14/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/14/2025 12:08:01 PM *** 11/14/25: 1). Please fix silt fence and keep it maintained. FBC 3307.1 2). Please have permit box that is laying on the ground remounted in the ground to maintain plan integrity. FBC [A]107.3.1 11/13/2025 - PREVIOUS INSPECTION NOTES 11/13/25: Cancelled by Applicant via text at @ 0718. | |||
| ROOF VALLEY & METAL | 11/13/2025 | CANCELLED BY APPLICANT | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/13/2025 9:11:59 AM *** 11/13/25: Cancelled by Applicant via text at @ 0718. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/13/2025 | CANCELLED BY APPLICANT | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/13/2025 9:11:17 AM *** 11/13/25: Cancelled by Applicant via text at @ 0718. | |||
| WALL SHEATHING | 11/13/2025 | CANCELLED BY APPLICANT | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/13/2025 9:11:36 AM *** 11/13/25: Cancelled by Applicant via text at @ 0718. | |||
| TIE BEAM / LINTEL | 10/28/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 10/28/2025 1:30:38 PM *** 10/27/2025 - PREVIOUS INSPECTION NOTES 10/27/25: Cancelled by Applicant via text at @ 0707. | |||
| TIE BEAM / LINTEL | 10/27/2025 | CANCELLED BY APPLICANT | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 10/27/2025 8:26:37 AM *** 10/27/25: Cancelled by Applicant via text at @ 0707. | |||
| SEWER TIE IN | 10/23/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| MONOLITHIC SLAB | 10/17/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 10/17/2025 1:55:33 PM *** | |||
| GRAVITY SEWER TEST | 10/07/2025 | APPROVED | MGIBSON |
| PLUMBING 1ST ROUGH UNDERGROUND | 09/25/2025 | APPROVED | RSIMS |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 09/24/2025 | APPROVED | RRICKS |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 09/08/2025 | APPROVED | PKNAPIK |
| WATER METER INSTALLATION REQUEST | 08/25/2025 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 09/15/2025 | 09/15/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/15/2025 | 09/15/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/08/2025 | 09/08/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 07/31/2025 | 08/01/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Approved contingent on final survey clearly depicting this lot negative impacting any adjacent lots. | |||
| ENGIN1 | COMPLETE | 07/31/2025 | 08/01/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/31/2025 | 07/31/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 07/17/2025 | 07/24/2025 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM - There is a low spot creating puddling along the right property line towards the back. - Based on the proposed elevations this lot is negatively impacting lot 31. Note: Lowering the rear yard drainage swale left of the swale high point will produce a more defined swale ensuring lot 31 is not negatively impacted. Please feel free to call or email if there are any questions or concerns. | |||
| ENGIN1 | COMPLETE | 07/17/2025 | 07/18/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/17/2025 | 07/17/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 07/02/2025 | 07/07/2025 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Based on the proposed elevation this lot is negatively impacting both adjacent lot. There shall be a minimum fall of 0.3' fall to the proposed conveyance swale. Please revise. Please feel free to call or email if there are any questions. | |||
| ENGIN1 | COMPLETE | 07/02/2025 | 07/07/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/02/2025 | 07/02/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 06/18/2025 | 06/26/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 06/18/2025 | 06/26/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 06/18/2025 | 06/24/2025 |
| Note: Released By: MICHELLE MCPARTLAND - - | |||
| ELEC | COMPLETE | 06/18/2025 | 06/23/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 06/18/2025 | 06/18/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 06/18/2025 | 06/23/2025 |
| LOCATE | COMPLETE | 06/18/2025 | 06/23/2025 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 06/18/2025 | 06/23/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 06/18/2025 | 06/18/2025 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Please provide more shots 10' beyond the property lines on lot 31 and lot 33 to clear depict the drainage pattern of this lot. | |||
| ZON | COMPLETE | 06/18/2025 | 06/20/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 06/18/2025 | 07/16/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| RSI REINSPECTION 1 | ¤35.00 | 12/18/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/18/2025 |
| FC IMPACT FEE EMS | ¤62.00 | 08/04/2025 |
| IMPACT FEE FIRE | ¤434.51 | 08/04/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 08/04/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 08/04/2025 |
| IMPACT FEE PARKS | ¤1,828.01 | 08/04/2025 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 08/04/2025 |
| IMPACT FEE TRANSPORTATION | ¤1,916.00 | 08/04/2025 |
| WATER- TURN ON | ¤50.00 | 08/04/2025 |
| ADJUSTMENT 10% | (¤120.20) | 08/04/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 08/04/2025 |
| INSPECTION - RESIDENTIAL | ¤913.00 | 08/04/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤258.96 | 08/04/2025 |
| WASTEWATER MAIN EXTENSION IMPA | ¤2,385.00 | 08/04/2025 |
| SURCHARGE FS 533.721 | ¤10.82 | 08/04/2025 |
| SURCHARGE - FS 468.631 | ¤16.23 | 08/04/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 08/04/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 08/04/2025 |
| SW ENG PRE APRON | ¤30.00 | 08/04/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 08/04/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 08/04/2025 |
| WATER METER W/ TAP | ¤2,326.93 | 08/04/2025 |
| SEWER CREDIT | (¤1,147.00) | 08/04/2025 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 08/04/2025 |
| WASTEWATER PERM REVIEW | ¤25.00 | 08/04/2025 |
| SEWER CAPITAL FACILITY | ¤4,415.00 | 08/04/2025 |
| WATER CAPITAL FACILITY FEE | ¤3,790.49 | 08/04/2025 |
| WATER PERMIT REVIEW | ¤25.00 | 08/04/2025 |
| WATER MAIN EXTENSION IMPACT | ¤917.27 | 08/04/2025 |
| SITE PLAN 30 | ¤30.00 | 08/04/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤24,608.02 |