I want to search for...

Permit #2025060794

Permit Details

Status: COED

Parcel Id: 07-11-31-7024-00410-0320
CONDITIONED SPACE: 1809 sqft
GARAGE: 406 sqft
OPENED PORCH (WITH ROOF) : 33 sqft
Total Square Footage: 2248 sqft
Block: 00410
Subdivision: -
Job Phone: 239-571-5325
Location Address: 40 PRESIDENT LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 08/04/2025
NOC: RECORDED
Applicant name: RYAN SCOTT DAVIS
Owner: SYNERGY HOMES LLC

Address

581 NW MERCANTILE PLACE 106

PORT SAINT LUCIE, FL 34986

Lot: 0320
Contracted Stated Job Value: ¤200,000.00
Job Description: Single Family Residence
Type: CN

Contractor

SYNERGY HOMES, LLC
Status Location Address State License Number
ACTIVE

1 HARGROVE GRADE, SUITE B1

PALM COAST, FL 32137

CBC1254289 (Exp: 08/31/2026)

Sub Contractors

TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733
WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
MICHAEL FRANK MORELLO
Status Location Address State License Number Phone Fax
ACTIVE

2 HARGROVE GRADE

PALM COAST, FL 32164

CAC1819466 (Exp: 08/31/2026) 386-445-5023 386-446-4614

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 12/18/2025 FINAL APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 12/18/2025 3:02:48 PM *** 12/16/2025 - PREVIOUS INSPECTION NOTES 12/16/25: 1). Garage door buck bolts are cut off at top on both sides of door. FBC [A]107.4 2). Master bathroom: shower stall is not sealed along the sill where the floor meets. (and at corners of sill) as required. FBC-P2705.1(3) 3). Guest bathroom: bathtub is not sealed along the front apron as required. FBC-P2705.1(3) 4). Garage door opener is not plugged in and safety eyes are still covered with plastic. Could not test. FBC-[A] 110.1 5). Garage ceiling has holes that need be sealed with approved material FBC- R302.11(4). 6). Front entry door and interior garage door are missing seals at perimeter. FBC EC TABLE R402.4.1.1 7). Pop-up assemblies in Master Bathroom are not working as required. (will not hold water). FBC-419.3 / FBC-P2711.3
BLD - BUILDING FINAL 12/16/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 12/16/2025 12:10:55 PM *** 12/16/25: 1). Garage door buck bolts are cut off at top on both sides of door. FBC [A]107.4 2). Master bathroom: shower stall is not sealed along the sill where the floor meets. (and at corners of sill) as required. FBC-P2705.1(3) 3). Guest bathroom: bathtub is not sealed along the front apron as required. FBC-P2705.1(3) 4). Garage door opener is not plugged in and safety eyes are still covered with plastic. Could not test. FBC-[A] 110.1 5). Garage ceiling has holes that need be sealed with approved material FBC- R302.11(4). 6). Front entry door and interior garage door are missing seals at perimeter. FBC EC TABLE R402.4.1.1 7). Pop-up assemblies in Master Bathroom are not working as required. (will not hold water). FBC-419.3 / FBC-P2711.3
U -UTILITY RESIDENTIAL FINAL 12/15/2025 FINAL APPROVED BHAINES
Note: Inspector Notes from Inspection 9035 NO IRR/NO CC
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/12/2025 APPROVED TPOLACEK
Note: 12/11/2025 - PREVIOUS INSPECTION NOTES 12/11/25 YOUR LEFT REAR CORNER SHOWS FLAT AND WATER SITTING INTO LEFT NEIGHBORING LOT. SEE PHOTO FOR REFERENCE. REAR YARD DRAIAGE Section 300.01 C(6) V-16 "6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement." POSITIVE FALL .10 EVERY 20 FT. Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 fee
ROW FIELD SURVEY /GRADING CERTIFICATION 12/12/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - STORMWATER FINAL 12/12/2025 APPROVED - AS NOTED TPOLACEK
Note: 12-12-25 TPOLACEK*** SMALL AMOUNT OF TRASH NEEDS TO BE CLEANED UP BUT I WILL APPROVE AS NOTED. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - FINAL APRON (AFTER POUR) 12/12/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/11/2025 Disapproved - NO FEE FSLADISH
Note: 12/11/25 YOUR LEFT REAR CORNER SHOWS FLAT AND WATER SITTING INTO LEFT NEIGHBORING LOT. SEE PHOTO FOR REFERENCE. REAR YARD DRAIAGE Section 300.01 C(6) V-16 "6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement." POSITIVE FALL .10 EVERY 20 FT. Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 fee
ELECTRIC - EARLY POWER 12/09/2025 APPROVED - AS NOTED MKRASKI
Note: Emailed FPL @ 10:05am
ELECTRIC - EARLY POWER 12/08/2025 CANCELLED BY APPLICANT RSIMS
Note: *** NOTES ADDED BY RSIMS 12/8/2025 2:28:16 PM *** 12/8/25: Cancelled by Applicant on phone at @ 1020.
U-CROSS CONNECTION 12/08/2025 APPROVED - AS NOTED BWRIGHT
Note: NO IRR/NO CC
ROW- PRE-APRON (PRE-POUR) 12/03/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. 12/2/2025 - PREVIOUS INSPECTION NOTES 12-2-25 TPOLACEK*** THERE IS NOT 4" THROUGHOUT THE UPPER PORTION, FORMBOARDS ARE DOWN IN TWO SPOTS, THERE IS NOT 2" OVER MITER END, THERE IS NOT 5" OVER LEFT SIDE PIPE AND THE APRON SLOPE EXCEEDS 8% PLEASE MAKE FORM BOARD CORRECTIONS BEFORE REQUESTING ANOTHER INSPECTION.
ROW- PRE-APRON (PRE-POUR) 12/02/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 12-2-25 TPOLACEK*** THERE IS NOT 4" THROUGHOUT THE UPPER PORTION, FORMBOARDS ARE DOWN IN TWO SPOTS, THERE IS NOT 2" OVER MITER END, THERE IS NOT 5" OVER LEFT SIDE PIPE AND THE APRON SLOPE EXCEEDS 8% PLEASE MAKE FORM BOARD CORRECTIONS BEFORE REQUESTING ANOTHER INSPECTION.
INSULATION 11/26/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 11/26/2025 1:53:57 PM *** Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 11/24/2025 11:33:23 AM *** 11/24/25: 1). Silt fence needs to be repaired on right side and along front. FBC 3307.1 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 11/14/2025 12:08:01 PM *** 11/14/25: 1). Please fix silt fence and keep it maintained. FBC 3307.1 2). Please have permit box that is laying on the ground remounted in the ground to maintain plan integrity. FBC [A]107.3.1 11/13/2025 - PREVIOUS INSPECTION NOTES 11/13/25: Cancelled by Applicant via text at @ 0718.
LATH/BRICK/ WATER BARRIER 11/26/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 11/26/2025 1:54:14 PM *** Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 11/24/2025 11:33:23 AM *** 11/24/25: 1). Silt fence needs to be repaired on right side and along front. FBC 3307.1 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 11/14/2025 12:08:01 PM *** 11/14/25: 1). Please fix silt fence and keep it maintained. FBC 3307.1 2). Please have permit box that is laying on the ground remounted in the ground to maintain plan integrity. FBC [A]107.3.1 11/13/2025 - PREVIOUS INSPECTION NOTES 11/13/25: Cancelled by Applicant via text at @ 0718.
LATH/BRICK/ WATER BARRIER 11/24/2025 CANCELLED BY APPLICANT RSIMS
Note: *** NOTES ADDED BY RSIMS 11/24/2025 11:32:13 AM *** 11/24/25: Cancelled by Applicant via phone call at @ 1130. Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 11/14/2025 12:08:01 PM *** 11/14/25: 1). Please fix silt fence and keep it maintained. FBC 3307.1 2). Please have permit box that is laying on the ground remounted in the ground to maintain plan integrity. FBC [A]107.3.1 11/13/2025 - PREVIOUS INSPECTION NOTES 11/13/25: Cancelled by Applicant via text at @ 0718.
ALL ROUGH 11/24/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 11/24/2025 11:33:23 AM *** 11/24/25: 1). Silt fence needs to be repaired on right side and along front. FBC 3307.1 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 11/14/2025 12:08:01 PM *** 11/14/25: 1). Please fix silt fence and keep it maintained. FBC 3307.1 2). Please have permit box that is laying on the ground remounted in the ground to maintain plan integrity. FBC [A]107.3.1 11/13/2025 - PREVIOUS INSPECTION NOTES 11/13/25: Cancelled by Applicant via text at @ 0718.
WALL SHEATHING 11/14/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 11/14/2025 11:31:57 AM *** 11/13/2025 - PREVIOUS INSPECTION NOTES 11/13/25: Cancelled by Applicant via text at @ 0718.
ROOF VALLEY & METAL 11/14/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 11/14/2025 12:03:00 PM *** 11/13/2025 - PREVIOUS INSPECTION NOTES 11/13/25: Cancelled by Applicant via text at @ 0718.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/14/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 11/14/2025 12:08:01 PM *** 11/14/25: 1). Please fix silt fence and keep it maintained. FBC 3307.1 2). Please have permit box that is laying on the ground remounted in the ground to maintain plan integrity. FBC [A]107.3.1 11/13/2025 - PREVIOUS INSPECTION NOTES 11/13/25: Cancelled by Applicant via text at @ 0718.
ROOF VALLEY & METAL 11/13/2025 CANCELLED BY APPLICANT RSIMS
Note: *** NOTES ADDED BY RSIMS 11/13/2025 9:11:59 AM *** 11/13/25: Cancelled by Applicant via text at @ 0718.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/13/2025 CANCELLED BY APPLICANT RSIMS
Note: *** NOTES ADDED BY RSIMS 11/13/2025 9:11:17 AM *** 11/13/25: Cancelled by Applicant via text at @ 0718.
WALL SHEATHING 11/13/2025 CANCELLED BY APPLICANT RSIMS
Note: *** NOTES ADDED BY RSIMS 11/13/2025 9:11:36 AM *** 11/13/25: Cancelled by Applicant via text at @ 0718.
TIE BEAM / LINTEL 10/28/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 10/28/2025 1:30:38 PM *** 10/27/2025 - PREVIOUS INSPECTION NOTES 10/27/25: Cancelled by Applicant via text at @ 0707.
TIE BEAM / LINTEL 10/27/2025 CANCELLED BY APPLICANT RSIMS
Note: *** NOTES ADDED BY RSIMS 10/27/2025 8:26:37 AM *** 10/27/25: Cancelled by Applicant via text at @ 0707.
SEWER TIE IN 10/23/2025 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
MONOLITHIC SLAB 10/17/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 10/17/2025 1:55:33 PM ***
GRAVITY SEWER TEST 10/07/2025 APPROVED MGIBSON
PLUMBING 1ST ROUGH UNDERGROUND 09/25/2025 APPROVED RSIMS
FORMBOARD SURVEY (OFFICE USE ONLY) 09/24/2025 APPROVED RRICKS
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 09/08/2025 APPROVED PKNAPIK
WATER METER INSTALLATION REQUEST 08/25/2025 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
SW1 COMPLETE 09/15/2025 09/15/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 09/15/2025 09/15/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BLD COMPLETE 09/08/2025 09/08/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SW1 COMPLETE 07/31/2025 08/01/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Approved contingent on final survey clearly depicting this lot negative impacting any adjacent lots.
ENGIN1 COMPLETE 07/31/2025 08/01/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ZON COMPLETE 07/31/2025 07/31/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SW1 HOLD 07/17/2025 07/24/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM - There is a low spot creating puddling along the right property line towards the back. - Based on the proposed elevations this lot is negatively impacting lot 31. Note: Lowering the rear yard drainage swale left of the swale high point will produce a more defined swale ensuring lot 31 is not negatively impacted. Please feel free to call or email if there are any questions or concerns.
ENGIN1 COMPLETE 07/17/2025 07/18/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ZON COMPLETE 07/17/2025 07/17/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SW1 HOLD 07/02/2025 07/07/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Based on the proposed elevation this lot is negatively impacting both adjacent lot. There shall be a minimum fall of 0.3' fall to the proposed conveyance swale. Please revise. Please feel free to call or email if there are any questions.
ENGIN1 COMPLETE 07/02/2025 07/07/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ZON COMPLETE 07/02/2025 07/02/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BADMIN COMPLETE 06/18/2025 06/26/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 06/18/2025 06/26/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
CUSVC COMPLETE 06/18/2025 06/24/2025
Note: Released By: MICHELLE MCPARTLAND - -
ELEC COMPLETE 06/18/2025 06/23/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/18/2025 06/18/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 06/18/2025 06/23/2025
LOCATE COMPLETE 06/18/2025 06/23/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 06/18/2025 06/23/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 06/18/2025 06/18/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Please provide more shots 10' beyond the property lines on lot 31 and lot 33 to clear depict the drainage pattern of this lot.
ZON COMPLETE 06/18/2025 06/20/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SWALE COMPLETE 06/18/2025 07/16/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
RSI REINSPECTION 1 ¤35.00 12/18/2025
REINSPECTION RESIDENTIAL ¤40.00 12/18/2025
FC IMPACT FEE EMS ¤62.00 08/04/2025
IMPACT FEE FIRE ¤434.51 08/04/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 08/04/2025
FC IMPACT FEE LIBRARY ¤268.00 08/04/2025
IMPACT FEE PARKS ¤1,828.01 08/04/2025
IMPACT FEE SCHOOL ¤5,450.00 08/04/2025
IMPACT FEE TRANSPORTATION ¤1,916.00 08/04/2025
WATER- TURN ON ¤50.00 08/04/2025
ADJUSTMENT 10% (¤120.20) 08/04/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 08/04/2025
INSPECTION - RESIDENTIAL ¤913.00 08/04/2025
PLAN REVIEW - RESIDENTIAL ¤258.96 08/04/2025
WASTEWATER MAIN EXTENSION IMPA ¤2,385.00 08/04/2025
SURCHARGE FS 533.721 ¤10.82 08/04/2025
SURCHARGE - FS 468.631 ¤16.23 08/04/2025
SW ENG - FOUNDATION SURVEY ¤20.00 08/04/2025
SW ENG INSPECTION 80 ¤80.00 08/04/2025
SW ENG PRE APRON ¤30.00 08/04/2025
SW ENG - REVIEW 20 ¤20.00 08/04/2025
SW ENG RES REVIEW 200 ¤200.00 08/04/2025
WATER METER W/ TAP ¤2,326.93 08/04/2025
SEWER CREDIT (¤1,147.00) 08/04/2025
WASTEWATER PERM INSPECTION ¤80.00 08/04/2025
WASTEWATER PERM REVIEW ¤25.00 08/04/2025
SEWER CAPITAL FACILITY ¤4,415.00 08/04/2025
WATER CAPITAL FACILITY FEE ¤3,790.49 08/04/2025
WATER PERMIT REVIEW ¤25.00 08/04/2025
WATER MAIN EXTENSION IMPACT ¤917.27 08/04/2025
SITE PLAN 30 ¤30.00 08/04/2025
Fees Total Due: ¤0.00 Total Paid: ¤24,608.02