I want to search for...
Permit #2025060805
Permit Details
Status: COED
| Parcel Id: 03-12-31-1126-00000-2370 |
| CONDITIONED SPACE: 2715 sqft |
| GARAGE: 614 sqft |
| OPENED PORCH (WITH ROOF) : 72 sqft |
| OPENED PORCH (WITH ROOF) : 208 sqft |
| Total Square Footage: 3609 sqft |
| Subdivision: 2344 - COLBERT LANDINGS PH 2 |
| Job Phone: 813-917-1689 |
| Location Address: 6 ARMENIA CT |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 07/03/2025 |
| NOC: RECORDED |
| Applicant name: SCOTT EVAN KEUNING |
| Owner: TAYLOR MORRISON OF FLORIDA INC |
|
Address 1275 W GRANADA BLVD ORMOND BEACH, FL 32174 |
|
Address SUITE 3B ORMOND BEACH, FL 32174 |
| Lot: 237 |
| Contracted Stated Job Value: ¤208,548.00 |
| Job Description: new single family |
| Type: CN |
Contractor
TAYLOR MORRISON OF FLORIDA INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
7785 BAY MEADOWS WAY, SUITE 105 JACKSONVILLE, FL 32256 |
CBC1265083 (Exp: 08/31/2026) | 813-917-1689 |
Sub Contractors
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PKWY SANFORD, FL 32771 |
CAC043953 (Exp: 08/31/2026) | 877-906-1113 |
JOSEPH HORATIO STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PARKWAY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2026) | 877-906-1113 |
BENJAMIN MICHAEL RAY
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
6310 MABLETON PKWY JACKSONVILLE, FL 32216 |
SUITE 1000 MABLETON, GA 30126 |
CFC1428415 (Exp: 08/31/2026) | 904-861-5421 | 904-861-5426 |
CHASE RANDOLPH MASSEY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
10048 103RD ST JACKSONVILLE, FL 32210 |
CCC1332486 (Exp: 08/31/2026) | 904-248-1133 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 11/17/2025 | FINAL APPROVED | BTAYLOR |
| Note: 11/5/2025 - PREVIOUS INSPECTION NOTES 11/5/25 1. No hot water FBCR P2705.1 – 4 2. Need sealant around right side window on the outside FBC EC TABLE R402.4.1.1 3. Gap too large in siding on right side of house by window FBC EC TABLE R402.4.1.1 4. Wall outlet in lenai not WR rated NEC 406.9(B)(1) 5. Missing bracket to hold undergorund service conduit NEC 342.3 6. Seal up all wall and ceiling penetrations in garage FBC 402.5.1.1 7. Missing grout in tile in rear master bath water closet 8. Rear master bath, right side sink drain stopper, not working properly 9. Rear master bath has broken cabinet door 10. Seal up wall penetrations in AH closet FBC 402.5.1.1 | |||
| U -UTILITY RESIDENTIAL FINAL | 11/10/2025 | FINAL APPROVED | BHAINES |
| Note: 11/5/2025 - PREVIOUS INSPECTION NOTES TREE IS TO CLOSE TO WATER PIT. NEED TO BE 3FT OR MORE. | |||
| ROW - STORMWATER FINAL | 11/05/2025 | APPROVED | FSLADISH |
| Note: 11/5/25 AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. __________________________________________________________________________________________________________________________ ***INSPECTORS NOTE. BUILDER IS REQUIRED TO SET SILT FENCE AROUND THE PERIMETER OF THE STRUCTURE BEFORE ROW FINAL PASSAGE. *** | |||
| U -UTILITY RESIDENTIAL FINAL | 11/05/2025 | Disapproved - NO FEE | BWRIGHT |
| Note: TREE IS TO CLOSE TO WATER PIT. NEED TO BE 3FT OR MORE. | |||
| BLD - BUILDING FINAL | 11/05/2025 | Disapproved -FEE REQUIRED | MCONTRYMAN |
| Note: 11/5/25 1. No hot water FBCR P2705.1 – 4 2. Need sealant around right side window on the outside FBC EC TABLE R402.4.1.1 3. Gap too large in siding on right side of house by window FBC EC TABLE R402.4.1.1 4. Wall outlet in lenai not WR rated NEC 406.9(B)(1) 5. Missing bracket to hold undergorund service conduit NEC 342.3 6. Seal up all wall and ceiling penetrations in garage FBC 402.5.1.1 7. Missing grout in tile in rear master bath water closet 8. Rear master bath, right side sink drain stopper, not working properly 9. Rear master bath has broken cabinet door 10. Seal up wall penetrations in AH closet FBC 402.5.1.1 | |||
| U-CROSS CONNECTION | 11/05/2025 | APPROVED - AS NOTED | BWRIGHT |
| Note: IRR WITH POTABLE WATER USING DC. NO CC | |||
| ROW - FINAL APRON (AFTER POUR) | 11/05/2025 | APPROVED - AS NOTED | FSLADISH |
| Note: 11/5/25 YOU WILL NEED TO DO A MINOR SKIM COAT FILL AROUND THE SEWER CLEANOUT POT. I AM GOING TO APPROVE TIS INSPECTION AS IT IS A MINOR CORRECTION, PLEASE MAKE SURE IT GETS COMPLETED EXPEDICIOUSLY. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 11/03/2025 | APPROVED | FSLADISH |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 11/03/2025 | APPROVED | FSLADISH |
| Note: 11/3/25 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ***INSPECTORS NOTE. BUILDER IS REQUIRED TO SET SILT FENCE AROUND THE PERIMETER OF THE STRUCTURE BEFORE ROW FINAL PASSAGE. *** | |||
| BLD - BUILDING FINAL | 10/31/2025 | CANCELLED BY APPLICANT | BTAYLOR |
| ELECTRIC - EARLY POWER | 09/30/2025 | APPROVED - AS NOTED | BTAYLOR |
| Note: 9-30-25 1. Emailed FPL at 11:05. 9/29/2025 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2200 8-13-25 1. Emailed FPL at 10:56. | |||
| ELECTRIC - EARLY POWER | 09/29/2025 | CANCELLED BY APPLICANT | BTAYLOR |
| Note: Inspector Notes from Inspection 2200 8-13-25 1. Emailed FPL at 10:56. | |||
| ROW- PRE-APRON (PRE-POUR) | 09/23/2025 | APPROVED | FSLADISH |
| Note: 9/23/25 BUILDER REFER TO CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. . IF FIBERGLASS OPTION IS USED, BUILDER REQUIRED TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK SITE FOR ANY STANDING WATER. ALSO VERIFY PIPE ELEVATION HAS NOT CHANGED. NO EXPANSION JOINTS ALLOWED | |||
| GRAVITY SEWER TEST | 09/08/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| SEWER TIE IN | 09/08/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| INSULATION | 08/28/2025 | APPROVED | BTAYLOR |
| Note: 8/27/2025 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 8/22/25 Will check at insulation 1. Electrical panel not phased out 2. Windows and doors exceed max shim spacing of 1/4" FBCR 609 3. No product approvals on site | |||
| INSULATION | 08/27/2025 | CANCELLED BY APPLICANT | BTAYLOR |
| Note: Inspector Notes from Inspection 2420 8/22/25 Will check at insulation 1. Electrical panel not phased out 2. Windows and doors exceed max shim spacing of 1/4" FBCR 609 3. No product approvals on site | |||
| ALL ROUGH | 08/22/2025 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 8/22/25 Will check at insulation 1. Electrical panel not phased out 2. Windows and doors exceed max shim spacing of 1/4" FBCR 609 3. No product approvals on site | |||
| LATH/BRICK/ WATER BARRIER | 08/15/2025 | APPROVED | BTAYLOR |
| Note: 8/14/2025 - PREVIOUS INSPECTION NOTES | |||
| ROOF VALLEY & METAL | 08/14/2025 | APPROVED | BTAYLOR |
| Note: 8/13/2025 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2460 8-12-25 1. Missing bearing blocks on truss A01. 2. Missing engineering on truss A11. Circled in truss packet. | |||
| LATH/BRICK/ WATER BARRIER | 08/14/2025 | CANCELLED BY APPLICANT | BTAYLOR |
| ELECTRIC-TUG | 08/13/2025 | APPROVED - AS NOTED | BTAYLOR |
| Note: 8-13-25 1. Emailed FPL at 10:56. | |||
| ROOF VALLEY & METAL | 08/13/2025 | CANCELLED BY APPLICANT | BTAYLOR |
| Note: Inspector Notes from Inspection 2460 8-12-25 1. Missing bearing blocks on truss A01. 2. Missing engineering on truss A11. Circled in truss packet. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/12/2025 | APPROVED - AS NOTED | BTAYLOR |
| Note: 8-12-25 1. Missing bearing blocks on truss A01. 2. Missing engineering on truss A11. Circled in truss packet. | |||
| WALL SHEATHING | 08/11/2025 | APPROVED | BTAYLOR |
| MONOLITHIC SLAB | 07/28/2025 | APPROVED | BTAYLOR |
| PLUMBING 1ST ROUGH UNDERGROUND | 07/24/2025 | APPROVED | MCONTRYMAN |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 07/23/2025 | APPROVED | RRICKS |
| WATER METER INSTALLATION REQUEST | 07/09/2025 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 07/22/2025 | 07/23/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/22/2025 | 07/22/2025 |
| Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 06/30/2025 | 06/30/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 06/18/2025 | 06/26/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 06/18/2025 | 06/26/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 06/18/2025 | 06/27/2025 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 06/18/2025 | 06/23/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 06/18/2025 | 06/18/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 06/18/2025 | 06/24/2025 |
| LOCATE | COMPLETE | 06/18/2025 | 06/23/2025 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 06/18/2025 | 06/24/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 06/18/2025 | 06/18/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Approved contingent on final survey depciting a well define rear yard drainage swale moving water to the front of this lot. | |||
| ZON | HOLD | 06/18/2025 | 06/23/2025 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Landscape plan driveway area does not match site plan being proposed. | |||
| URB | COMPLETE | 06/18/2025 | 06/26/2025 |
| Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 11/10/2025 |
| FC IMPACT FEE EMS | ¤62.00 | 07/03/2025 |
| IMPACT FEE FIRE | ¤434.51 | 07/03/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 07/03/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 07/03/2025 |
| IMPACT FEE PARKS | ¤1,828.01 | 07/03/2025 |
| IMPACT FEE TRANSPORTATION | ¤3,502.00 | 07/03/2025 |
| WATER METER W/OUT TAP | ¤965.03 | 07/03/2025 |
| SURCHARGE FS 533.721 | ¤16.57 | 07/03/2025 |
| SURCHARGE - FS 468.631 | ¤24.85 | 07/03/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 07/03/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 07/03/2025 |
| SW ENG PRE APRON | ¤30.00 | 07/03/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 07/03/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 07/03/2025 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 07/03/2025 |
| WASTEWATER PERM REVIEW | ¤25.00 | 07/03/2025 |
| SEWER CAPITAL FACILITY | ¤3,613.92 | 07/03/2025 |
| WATER CAPITAL FACILITY FEE | ¤3,039.48 | 07/03/2025 |
| WATER PERMIT INSPECTION | ¤40.00 | 07/03/2025 |
| WATER PERMIT REVIEW | ¤25.00 | 07/03/2025 |
| SITE PLAN 30 | ¤30.00 | 07/03/2025 |
| WATER-METER | ¤965.03 | 07/03/2025 |
| WATER- TURN ON | ¤50.00 | 07/03/2025 |
| WATER- TURN ON | ¤50.00 | 07/03/2025 |
| ADJUSTMENT 10% | (¤184.09) | 07/03/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 07/03/2025 |
| INSPECTION - RESIDENTIAL | ¤1,410.75 | 07/03/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤400.14 | 07/03/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤17,284.20 |