I want to search for...

Permit #2025060805

Permit Details

Status: COED

Parcel Id: 03-12-31-1126-00000-2370
CONDITIONED SPACE: 2715 sqft
GARAGE: 614 sqft
OPENED PORCH (WITH ROOF) : 72 sqft
OPENED PORCH (WITH ROOF) : 208 sqft
Total Square Footage: 3609 sqft
Subdivision: 2344 - COLBERT LANDINGS PH 2
Job Phone: 813-917-1689
Location Address: 6 ARMENIA CT
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 07/03/2025
NOC: RECORDED
Applicant name: SCOTT EVAN KEUNING
Owner: TAYLOR MORRISON OF FLORIDA INC

Address

1275 W GRANADA BLVD

ORMOND BEACH, FL 32174

Address

SUITE 3B

ORMOND BEACH, FL 32174

Lot: 237
Contracted Stated Job Value: ¤208,548.00
Job Description: new single family
Type: CN

Contractor

TAYLOR MORRISON OF FLORIDA INC
Status Location Address State License Number Phone
ACTIVE

7785 BAY MEADOWS WAY, SUITE 105

JACKSONVILLE, FL 32256

CBC1265083 (Exp: 08/31/2026) 813-917-1689

Sub Contractors

JOSEPH H STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PKWY

SANFORD, FL 32771

CAC043953 (Exp: 08/31/2026) 877-906-1113
JOSEPH HORATIO STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PARKWAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2026) 877-906-1113
BENJAMIN MICHAEL RAY
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

6310 MABLETON PKWY

JACKSONVILLE, FL 32216

SUITE 1000

MABLETON, GA 30126

CFC1428415 (Exp: 08/31/2026) 904-861-5421 904-861-5426
CHASE RANDOLPH MASSEY
Status Location Address State License Number Phone
ACTIVE

10048 103RD ST

JACKSONVILLE, FL 32210

CCC1332486 (Exp: 08/31/2026) 904-248-1133

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 11/17/2025 FINAL APPROVED BTAYLOR
Note: 11/5/2025 - PREVIOUS INSPECTION NOTES 11/5/25 1. No hot water FBCR P2705.1 – 4 2. Need sealant around right side window on the outside FBC EC TABLE R402.4.1.1 3. Gap too large in siding on right side of house by window FBC EC TABLE R402.4.1.1 4. Wall outlet in lenai not WR rated NEC 406.9(B)(1) 5. Missing bracket to hold undergorund service conduit NEC 342.3 6. Seal up all wall and ceiling penetrations in garage FBC 402.5.1.1 7. Missing grout in tile in rear master bath water closet 8. Rear master bath, right side sink drain stopper, not working properly 9. Rear master bath has broken cabinet door 10. Seal up wall penetrations in AH closet FBC 402.5.1.1
U -UTILITY RESIDENTIAL FINAL 11/10/2025 FINAL APPROVED BHAINES
Note: 11/5/2025 - PREVIOUS INSPECTION NOTES TREE IS TO CLOSE TO WATER PIT. NEED TO BE 3FT OR MORE.
ROW - STORMWATER FINAL 11/05/2025 APPROVED FSLADISH
Note: 11/5/25 AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. __________________________________________________________________________________________________________________________ ***INSPECTORS NOTE. BUILDER IS REQUIRED TO SET SILT FENCE AROUND THE PERIMETER OF THE STRUCTURE BEFORE ROW FINAL PASSAGE. ***
U -UTILITY RESIDENTIAL FINAL 11/05/2025 Disapproved - NO FEE BWRIGHT
Note: TREE IS TO CLOSE TO WATER PIT. NEED TO BE 3FT OR MORE.
BLD - BUILDING FINAL 11/05/2025 Disapproved -FEE REQUIRED MCONTRYMAN
Note: 11/5/25 1. No hot water FBCR P2705.1 – 4 2. Need sealant around right side window on the outside FBC EC TABLE R402.4.1.1 3. Gap too large in siding on right side of house by window FBC EC TABLE R402.4.1.1 4. Wall outlet in lenai not WR rated NEC 406.9(B)(1) 5. Missing bracket to hold undergorund service conduit NEC 342.3 6. Seal up all wall and ceiling penetrations in garage FBC 402.5.1.1 7. Missing grout in tile in rear master bath water closet 8. Rear master bath, right side sink drain stopper, not working properly 9. Rear master bath has broken cabinet door 10. Seal up wall penetrations in AH closet FBC 402.5.1.1
U-CROSS CONNECTION 11/05/2025 APPROVED - AS NOTED BWRIGHT
Note: IRR WITH POTABLE WATER USING DC. NO CC
ROW - FINAL APRON (AFTER POUR) 11/05/2025 APPROVED - AS NOTED FSLADISH
Note: 11/5/25 YOU WILL NEED TO DO A MINOR SKIM COAT FILL AROUND THE SEWER CLEANOUT POT. I AM GOING TO APPROVE TIS INSPECTION AS IT IS A MINOR CORRECTION, PLEASE MAKE SURE IT GETS COMPLETED EXPEDICIOUSLY.
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/03/2025 APPROVED FSLADISH
ROW FIELD SURVEY /GRADING CERTIFICATION 11/03/2025 APPROVED FSLADISH
Note: 11/3/25 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ***INSPECTORS NOTE. BUILDER IS REQUIRED TO SET SILT FENCE AROUND THE PERIMETER OF THE STRUCTURE BEFORE ROW FINAL PASSAGE. ***
BLD - BUILDING FINAL 10/31/2025 CANCELLED BY APPLICANT BTAYLOR
ELECTRIC - EARLY POWER 09/30/2025 APPROVED - AS NOTED BTAYLOR
Note: 9-30-25 1. Emailed FPL at 11:05. 9/29/2025 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2200 8-13-25 1. Emailed FPL at 10:56.
ELECTRIC - EARLY POWER 09/29/2025 CANCELLED BY APPLICANT BTAYLOR
Note: Inspector Notes from Inspection 2200 8-13-25 1. Emailed FPL at 10:56.
ROW- PRE-APRON (PRE-POUR) 09/23/2025 APPROVED FSLADISH
Note: 9/23/25 BUILDER REFER TO CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. . IF FIBERGLASS OPTION IS USED, BUILDER REQUIRED TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK SITE FOR ANY STANDING WATER. ALSO VERIFY PIPE ELEVATION HAS NOT CHANGED. NO EXPANSION JOINTS ALLOWED
GRAVITY SEWER TEST 09/08/2025 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
SEWER TIE IN 09/08/2025 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
INSULATION 08/28/2025 APPROVED BTAYLOR
Note: 8/27/2025 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 8/22/25 Will check at insulation 1. Electrical panel not phased out 2. Windows and doors exceed max shim spacing of 1/4" FBCR 609 3. No product approvals on site
INSULATION 08/27/2025 CANCELLED BY APPLICANT BTAYLOR
Note: Inspector Notes from Inspection 2420 8/22/25 Will check at insulation 1. Electrical panel not phased out 2. Windows and doors exceed max shim spacing of 1/4" FBCR 609 3. No product approvals on site
ALL ROUGH 08/22/2025 APPROVED - AS NOTED MCONTRYMAN
Note: 8/22/25 Will check at insulation 1. Electrical panel not phased out 2. Windows and doors exceed max shim spacing of 1/4" FBCR 609 3. No product approvals on site
LATH/BRICK/ WATER BARRIER 08/15/2025 APPROVED BTAYLOR
Note: 8/14/2025 - PREVIOUS INSPECTION NOTES
ROOF VALLEY & METAL 08/14/2025 APPROVED BTAYLOR
Note: 8/13/2025 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2460 8-12-25 1. Missing bearing blocks on truss A01. 2. Missing engineering on truss A11. Circled in truss packet.
LATH/BRICK/ WATER BARRIER 08/14/2025 CANCELLED BY APPLICANT BTAYLOR
ELECTRIC-TUG 08/13/2025 APPROVED - AS NOTED BTAYLOR
Note: 8-13-25 1. Emailed FPL at 10:56.
ROOF VALLEY & METAL 08/13/2025 CANCELLED BY APPLICANT BTAYLOR
Note: Inspector Notes from Inspection 2460 8-12-25 1. Missing bearing blocks on truss A01. 2. Missing engineering on truss A11. Circled in truss packet.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/12/2025 APPROVED - AS NOTED BTAYLOR
Note: 8-12-25 1. Missing bearing blocks on truss A01. 2. Missing engineering on truss A11. Circled in truss packet.
WALL SHEATHING 08/11/2025 APPROVED BTAYLOR
MONOLITHIC SLAB 07/28/2025 APPROVED BTAYLOR
PLUMBING 1ST ROUGH UNDERGROUND 07/24/2025 APPROVED MCONTRYMAN
FORMBOARD SURVEY (OFFICE USE ONLY) 07/23/2025 APPROVED RRICKS
WATER METER INSTALLATION REQUEST 07/09/2025 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
SW1 COMPLETE 07/22/2025 07/23/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 07/22/2025 07/22/2025
Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM
ZON COMPLETE 06/30/2025 06/30/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BADMIN COMPLETE 06/18/2025 06/26/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 06/18/2025 06/26/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 06/18/2025 06/27/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 06/18/2025 06/23/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/18/2025 06/18/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 06/18/2025 06/24/2025
LOCATE COMPLETE 06/18/2025 06/23/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 06/18/2025 06/24/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 06/18/2025 06/18/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Approved contingent on final survey depciting a well define rear yard drainage swale moving water to the front of this lot.
ZON HOLD 06/18/2025 06/23/2025
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Landscape plan driveway area does not match site plan being proposed.
URB COMPLETE 06/18/2025 06/26/2025
Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 11/10/2025
FC IMPACT FEE EMS ¤62.00 07/03/2025
IMPACT FEE FIRE ¤434.51 07/03/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 07/03/2025
FC IMPACT FEE LIBRARY ¤268.00 07/03/2025
IMPACT FEE PARKS ¤1,828.01 07/03/2025
IMPACT FEE TRANSPORTATION ¤3,502.00 07/03/2025
WATER METER W/OUT TAP ¤965.03 07/03/2025
SURCHARGE FS 533.721 ¤16.57 07/03/2025
SURCHARGE - FS 468.631 ¤24.85 07/03/2025
SW ENG - FOUNDATION SURVEY ¤20.00 07/03/2025
SW ENG INSPECTION 80 ¤80.00 07/03/2025
SW ENG PRE APRON ¤30.00 07/03/2025
SW ENG - REVIEW 20 ¤20.00 07/03/2025
SW ENG RES REVIEW 200 ¤200.00 07/03/2025
WASTEWATER PERM INSPECTION ¤80.00 07/03/2025
WASTEWATER PERM REVIEW ¤25.00 07/03/2025
SEWER CAPITAL FACILITY ¤3,613.92 07/03/2025
WATER CAPITAL FACILITY FEE ¤3,039.48 07/03/2025
WATER PERMIT INSPECTION ¤40.00 07/03/2025
WATER PERMIT REVIEW ¤25.00 07/03/2025
SITE PLAN 30 ¤30.00 07/03/2025
WATER-METER ¤965.03 07/03/2025
WATER- TURN ON ¤50.00 07/03/2025
WATER- TURN ON ¤50.00 07/03/2025
ADJUSTMENT 10% (¤184.09) 07/03/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 07/03/2025
INSPECTION - RESIDENTIAL ¤1,410.75 07/03/2025
PLAN REVIEW - RESIDENTIAL ¤400.14 07/03/2025
Fees Total Due: ¤0.00 Total Paid: ¤17,284.20