I want to search for...
Permit #2025060818
Permit Details
Status: INSPECT
| Parcel Id: 03-12-31-1126-00000-2430 |
| CONDITIONED SPACE: 2746 sqft |
| GARAGE: 600 sqft |
| OPENED PORCH (WITH ROOF) : 155 sqft |
| OPENED PORCH (WITH ROOF) : 384 sqft |
| Total Square Footage: 3885 sqft |
| Subdivision: 2344 - COLBERT LANDINGS PH 2 |
| Job Phone: 813-917-1689 |
| Location Address: 5 ARMENIA CT |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 11/10/2025 |
| NOC: RECORDED |
| Applicant name: SCOTT EVAN KEUNING |
| Owner: TAYLOR MORRISON OF FLORIDA INC |
|
Address 1275 W GRANADA BLVD ORMOND BEACH, FL 32174 |
|
Address SUITE 3B ORMOND BEACH, FL 32174 |
| Lot: 243 |
| Contracted Stated Job Value: ¤242,301.00 |
| Job Description: SINGLE FAMILY |
| Type: CN |
Contractor
TAYLOR MORRISON OF FLORIDA INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
7785 BAY MEADOWS WAY, SUITE 105 JACKSONVILLE, FL 32256 |
CBC1265083 (Exp: 08/31/2026) | 813-917-1689 |
Sub Contractors
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PKWY SANFORD, FL 32771 |
CAC043953 (Exp: 08/31/2026) | 877-906-1113 |
JOSEPH HORATIO STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PARKWAY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2026) | 877-906-1113 |
BENJAMIN MICHAEL RAY
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
6310 MABLETON PKWY JACKSONVILLE, FL 32216 |
SUITE 1000 MABLETON, GA 30126 |
CFC1428415 (Exp: 08/31/2026) | 904-861-5421 | 904-861-5426 |
CHASE RANDOLPH MASSEY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
10048 103RD ST JACKSONVILLE, FL 32210 |
CCC1332486 (Exp: 08/31/2026) | 904-248-1133 |
Inspection History
| Type | Request Date | Result | Inspector |
| ELECTRIC-TUG | 05/05/2026 | APPROVED - AS NOTED | CVANSTRAHLEN |
| Note: Please corrected Item #1 5/1/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-electrical outlet box need to be firm attached to wall , per FL building code #2-Schedule 80 PVC pipe too short , need to be 8" to 10" lowers | |||
| ELECTRIC-TUG | 05/01/2026 | Disapproved - NO FEE | CVANSTRAHLEN |
| Note: Please fix items before next inspection #1-electrical outlet box need to be firm attached to wall , per FL building code #2-Schedule 80 PVC pipe too short , need to be 8" to 10" lowers | |||
| INSULATION | 05/01/2026 | APPROVED | CVANSTRAHLEN |
| Note: Inspector Notes from Inspection 2420 Please fix items before next inspection #1-FBCR 609.1-GAP AT WINDOW/DOOR REVEAL TOO LARGE > 1/4 " PER MANUFACTURERS SPECS ( all areas mark with red sharpie market )( windows , back slidding door and front door ) #2-FBCR P2603.2.1-NEEDS NAIL GUARD ON STUD < 1 1/4" - PROPERLY SIZE (right side share bathroom )sink #3- Missing FL approval sheet #4 add stud to wall right side wall , stud on side have 4"x 2" knoch | |||
| LATH/BRICK/ WATER BARRIER | 04/28/2026 | APPROVED | CVANSTRAHLEN |
| ALL ROUGH | 04/28/2026 | APPROVED - AS NOTED | CVANSTRAHLEN |
| Note: Please fix items before next inspection #1-FBCR 609.1-GAP AT WINDOW/DOOR REVEAL TOO LARGE > 1/4 " PER MANUFACTURERS SPECS ( all areas mark with red sharpie market )( windows , back slidding door and front door ) #2-FBCR P2603.2.1-NEEDS NAIL GUARD ON STUD < 1 1/4" - PROPERLY SIZE (right side share bathroom )sink #3- Missing FL approval sheet #4 add stud to wall right side wall , stud on side have 4"x 2" knoch | |||
| ROOF VALLEY & METAL | 04/14/2026 | APPROVED | CVANSTRAHLEN |
| WALL SHEATHING | 04/08/2026 | APPROVED | CVANSTRAHLEN |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/08/2026 | APPROVED | CVANSTRAHLEN |
| Note: *** NOTES ADDED BY CVANSTRAHLEN 4/8/2026 1:11:42 PM *** FBC 3302.2-NEEDS DUMPSTER | |||
| MONOLITHIC SLAB | 03/20/2026 | APPROVED | KSANDOE |
| PLUMBING 1ST ROUGH UNDERGROUND | 03/18/2026 | APPROVED | PKNAPIK |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 03/17/2026 | APPROVED | PFLANAGAN |
| WATER METER INSTALLATION REQUEST | 03/04/2026 | APPROVED | ISANDERSON |
| U-CROSS CONNECTION | |||
| ROW- PRE-APRON (PRE-POUR) | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | |||
| ROW - STORMWATER FINAL | |||
| U -UTILITY RESIDENTIAL FINAL | |||
| GRAVITY SEWER TEST | |||
| SEWER TIE IN | |||
| ELECTRIC - EARLY POWER | |||
| BLD - BUILDING FINAL |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 04/22/2026 | 04/23/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 03/17/2026 | 03/17/2026 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/17/2026 | 03/17/2026 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 01/09/2026 | 01/09/2026 |
| Note: Marked INFORMATION By: JAZMIN ROSARIO - - JROSARIO@PALMCOASTGOV.COM rename file to match file type being uploaded for review ex: product approval = product approval. | |||
| BLD | COMPLETE | 01/09/2026 | 01/12/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 09/03/2025 | 09/05/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Grading comments: Approved as noted - Please ensure that there are no slopes greater than 4:1 during grading. | |||
| ENGIN1 | COMPLETE | 09/03/2025 | 09/05/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/03/2025 | 09/03/2025 |
| Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM | |||
| URB | COMPLETE | 06/24/2025 | 07/02/2025 |
| Note: Released By: MATTHEW SIERRA - (386)286-2002 - MSIERRA@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 06/18/2025 | 06/25/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 06/18/2025 | 06/25/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 06/18/2025 | 06/27/2025 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 06/18/2025 | 06/23/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 06/18/2025 | 06/23/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 06/18/2025 | 06/24/2025 |
| LOCATE | COMPLETE | 06/18/2025 | 06/23/2025 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 06/18/2025 | 06/24/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 06/18/2025 | 06/18/2025 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Please provide more elevations behind rear yard drianage swale depicting water flowing to the rear yard drainage swale instead of flowing to the back property line. | |||
| ZON | COMPLETE | 06/18/2025 | 06/24/2025 |
| Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| FC IMPACT FEE EMS | ¤62.00 | 11/10/2025 |
| IMPACT FEE FIRE | ¤434.51 | 11/10/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 11/10/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 11/10/2025 |
| IMPACT FEE PARKS | ¤1,828.01 | 11/10/2025 |
| IMPACT FEE TRANSPORTATION | ¤3,502.00 | 11/10/2025 |
| WATER METER W/OUT TAP | ¤965.03 | 11/10/2025 |
| SURCHARGE FS 533.721 | ¤17.24 | 11/10/2025 |
| SURCHARGE - FS 468.631 | ¤25.85 | 11/10/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 11/10/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 11/10/2025 |
| SW ENG PRE APRON | ¤30.00 | 11/10/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 11/10/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 11/10/2025 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 11/10/2025 |
| WASTEWATER PERM REVIEW | ¤25.00 | 11/10/2025 |
| SEWER CAPITAL FACILITY | ¤3,613.92 | 11/10/2025 |
| WATER CAPITAL FACILITY FEE | ¤3,039.48 | 11/10/2025 |
| WATER PERMIT INSPECTION | ¤40.00 | 11/10/2025 |
| WATER PERMIT REVIEW | ¤25.00 | 11/10/2025 |
| SITE PLAN 30 | ¤30.00 | 11/10/2025 |
| WATER-METER | ¤965.03 | 11/10/2025 |
| WATER- TURN ON | ¤50.00 | 11/10/2025 |
| WATER- TURN ON | ¤50.00 | 11/10/2025 |
| ADJUSTMENT 10% | (¤191.50) | 11/10/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 11/10/2025 |
| INSPECTION - RESIDENTIAL | ¤1,468.50 | 11/10/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤416.52 | 11/10/2025 |
| PLAN REVIEW - REVISION | ¤32.50 | |
| Fees | Total Due: ¤32.50 | Total Paid: ¤17,312.59 |