I want to search for...

Permit #2025060900

Permit Details

Status: COED

Parcel Id: 07-11-31-7037-00260-0020
CONDITIONED SPACE: 2400 sqft
GARAGE: 566 sqft
OPENED PORCH (WITH ROOF) : 350 sqft
Total Square Footage: 3316 sqft
Block: 00260
Subdivision: -
Job Phone: 386-283-2035
Location Address: 10 LYONS PL
Type: DU - DUPLEX
Issue Date: 07/11/2025
NOC: RECORDED
Applicant name: OLEG BELINSKIY
Owner: DIAMOND JEFFREY

Address

2533 BATCHELDER STREET

BROOKLYN, NY 11235

Address

8J

BROOKLYN, NY 11235

Lot: 0020
Contracted Stated Job Value: ¤350,000.00
Job Description: Duplex
Type: CN

Contractor

FLORIDAS BEST BUILDERS INC
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE

PALM COAST, FL 32164

CBC1264760 (Exp: 08/31/2026) 386-283-2035

Sub Contractors

OLEG BELINSKIY
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE19

PALM COAST, FL 32167

CCC1325974 (Exp: 08/31/2026) 386-263-7906
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)
SERGEY A VORONIN
Status Location Address State License Number Phone
ACTIVE

7631 SEVERN

JACKSONVILLE, FL 32224

EC13011326 (Exp: 08/31/2026) 360-798-2819
TIMUR ISPARYAN
Status Location Address State License Number Phone Fax
ACTIVE

3665 SPRINK PARK ROAD

JACKSONVILLE , FL 32207

CMC1249968 (Exp: 08/31/2026) 904-245-1818 904-337-1910

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 02/13/2026 FINAL APPROVED JSTEWART
Note: 2/11/2026 - PREVIOUS INSPECTION NOTES 2/11/26 A Side: 1. Seal up around shower glass in master bedroom 2. Seal up around dryer box FBC EC TABLE R402.4.1.1 3. Pep tank needs to be GFCi NEC 422.5 4. AH requires disconnect or lockout breaker NEC 422.31 & 110.25 5. No anti tip on range FBCR M1901.2 B Side: 1. Seal up around shower glass in master bedroom 2. Seal up around dryer box FBC EC TABLE R402.4.1.1 3. Pep tank needs to be GFCi NEC 422.5 4. AH requires disconnect or lockout breaker NEC 422.31 & 110.25 5. Seal up LV wires under meter/main FBC EC TABLE R402.4.1.1 6. Large chip in guest bath tub/shower 7. Chip in tile in master shower for wand
U-CROSS CONNECTION 02/11/2026 APPROVED BWRIGHT
BLD - BUILDING FINAL 02/11/2026 Disapproved -FEE REQUIRED MCONTRYMAN
Note: 2/11/26 A Side: 1. Seal up around shower glass in master bedroom 2. Seal up around dryer box FBC EC TABLE R402.4.1.1 3. Pep tank needs to be GFCi NEC 422.5 4. AH requires disconnect or lockout breaker NEC 422.31 & 110.25 5. No anti tip on range FBCR M1901.2 B Side: 1. Seal up around shower glass in master bedroom 2. Seal up around dryer box FBC EC TABLE R402.4.1.1 3. Pep tank needs to be GFCi NEC 422.5 4. AH requires disconnect or lockout breaker NEC 422.31 & 110.25 5. Seal up LV wires under meter/main FBC EC TABLE R402.4.1.1 6. Large chip in guest bath tub/shower 7. Chip in tile in master shower for wand
U -UTILITY RESIDENTIAL FINAL 02/11/2026 FINAL APPROVED BWRIGHT
ROW - FINAL APRON (AFTER POUR) 02/09/2026 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection.
ROW- FINAL SURVEY/GRADING CERTIFICATION 02/09/2026 APPROVED PFLANAGAN
Note: FINAL SURVEY MEETS CITY STANDARDS
ROW FIELD SURVEY /GRADING CERTIFICATION 02/09/2026 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection.
ROW - FINAL INSPECTION 02/09/2026 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection.
ROW- PRE-APRON (PRE-POUR) 01/06/2026 APPROVED - AS NOTED TPOLACEK
Note: 01-06-26 TPOLACEK*** APPROVED TO LAY PAVERS ++++++++++++++++++++++++++++++++++++++++++++++++++++++ 12/29/2025 - PREVIOUS INSPECTION NOTES AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON, SIDEWALK AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS
ROW- PAVER RESTRAINTS 12/29/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON, SIDEWALK AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS
ROW- PRE-APRON (PRE-POUR) 12/29/2025 PARTIALLY APPROVED TPOLACEK
Note: AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON, SIDEWALK AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS
ELECTRIC - EARLY POWER 12/10/2025 APPROVED - AS NOTED MCONTRYMAN
Note: 12/10/25 Emailed FPL 12/8/2025 - PREVIOUS INSPECTION NOTES Both Sides Please trim outlets / install Blank face plates at Microwave, and under sink receptacle. NEC 110.27
ELECTRIC - EARLY POWER 12/08/2025 Disapproved - NO FEE JSTEWART
Note: Both Sides Please trim outlets / install Blank face plates at Microwave, and under sink receptacle. NEC 110.27
GRAVITY SEWER TEST 12/03/2025 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2060 THIS WAS A VIRTUAL INSPECTION ADRESS NOT POSTED, FBCR-319.1, SWALE BLOCKED BY PORTABLE, FBC-3303.5, WATER SERVICE NOT RAN ON BOTH UNITS
SEWER TIE IN 12/03/2025 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2075 THIS WAS A VIRTUAL INSPECTION Inspector Notes from Inspection 2060 THIS WAS A VIRTUAL INSPECTION ADRESS NOT POSTED, FBCR-319.1, SWALE BLOCKED BY PORTABLE, FBC-3303.5, WATER SERVICE NOT RAN ON BOTH UNITS Inspector Notes from Inspection 2075 THIS WAS A VIRTUAL INSPECTION Inspector Notes from Inspection 2060 THIS WAS A VIRTUAL INSPECTION ADRESS NOT POSTED, FBCR-319.1, SWALE BLOCKED BY PORTABLE, FBC-3303.5, WATER SERVICE NOT RAN ON BOTH UNITS
PEP TANK INSTALLATION REQUEST 10/29/2025 APPROVED CBOWERMASTER
INSULATION 10/03/2025 APPROVED MCONTRYMAN
Note: 10/1/2025 - PREVIOUS INSPECTION NOTES 10/1/25 1. Still no water pressure in unit A (left side) FBCR P2503.5 --Unit B (right side) is good Inspector Notes from Inspection 2320 9/26/25 Will check at next inspection 1. Where plumbing comes form floor under tubs and sink on both sides needs to be leveled out with floor with concrete to prevent rodent and termite access 2. Duct layout does not match on unit B and also both units have hand written layout of some ducts. This needs to be changed to show appropraite duct layout and approved before final FBC(A) 107.4 Unit A: 1. No water pressure FBCR P2503.5 2. Dryer vent strap needs to be resecured
INSULATION 10/01/2025 Disapproved -FEE REQUIRED MCONTRYMAN
Note: 10/1/25 1. Still no water pressure in unit A (left side) FBCR P2503.5 --Unit B (right side) is good Inspector Notes from Inspection 2320 9/26/25 Will check at next inspection 1. Where plumbing comes form floor under tubs and sink on both sides needs to be leveled out with floor with concrete to prevent rodent and termite access 2. Duct layout does not match on unit B and also both units have hand written layout of some ducts. This needs to be changed to show appropraite duct layout and approved before final FBC(A) 107.4 Unit A: 1. No water pressure FBCR P2503.5 2. Dryer vent strap needs to be resecured
LATH/BRICK/ WATER BARRIER 09/29/2025 APPROVED - AS NOTED MKRASKI
Note: 9/26/25 Will check at next inspection 1. Where plumbing comes form floor under tubs and sink on both sides needs to be leveled out with floor with concrete to prevent rodent and termite access 2. Duct layout does not match on unit B and also both units have hand written layout of some ducts. This needs to be changed to show appropraite duct layout and approved before final FBC(A) 107.4 Unit A: 1. No water pressure FBCR P2503.5 2. Dryer vent strap needs to be resecured
ALL ROUGH 09/26/2025 APPROVED - AS NOTED MCONTRYMAN
Note: 9/26/25 Will check at next inspection 1. Where plumbing comes form floor under tubs and sink on both sides needs to be leveled out with floor with concrete to prevent rodent and termite access 2. Duct layout does not match on unit B and also both units have hand written layout of some ducts. This needs to be changed to show appropraite duct layout and approved before final FBC(A) 107.4 Unit A: 1. No water pressure FBCR P2503.5 2. Dryer vent strap needs to be resecured
ALL ROUGH 09/25/2025 CANCELLED BY APPLICANT WEB
FIREWALL FINAL 09/24/2025 APPROVED FWILLIS
FIREWALL DRYWALL NAILING 09/22/2025 APPROVED FWILLIS
ROOF VALLEY & METAL 09/16/2025 APPROVED FWILLIS
WALL SHEATHING 09/12/2025 APPROVED JSTEWART
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/12/2025 APPROVED JSTEWART
FIREWALL FRAMING 09/12/2025 APPROVED JSTEWART
TIE BEAM / LINTEL 09/02/2025 APPROVED FWILLIS
MONOLITHIC SLAB 08/12/2025 APPROVED JSTEWART
PLUMBING 1ST ROUGH UNDERGROUND 08/08/2025 APPROVED - AS NOTED MGIBSON
Note: ADRESS NOT POSTED, FBCR-319.1, SWALE BLOCKED BY PORTABLE, FBC-3303.5, WATER SERVICE NOT RAN ON BOTH UNITS
FORMBOARD SURVEY (OFFICE USE ONLY) 08/08/2025 APPROVED PFLANAGAN
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 07/29/2025 APPROVED PKNAPIK
WATER METER INSTALLATION REQUEST 07/17/2025 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
SW1 COMPLETE 08/26/2025 08/26/2025
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 08/26/2025 08/26/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
SW1 COMPLETE 08/07/2025 08/07/2025
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 08/07/2025 08/07/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 07/29/2025 07/29/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/30/2025 07/01/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ZON HOLD 06/30/2025 06/30/2025
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please turn in original right of way agreement for recording
ZON COMPLETE 06/30/2025 07/01/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SWALE COMPLETE 06/23/2025 07/09/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
BADMIN COMPLETE 06/20/2025 06/26/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 06/20/2025 06/26/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
CUSVC COMPLETE 06/20/2025 06/25/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 06/20/2025 06/23/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/20/2025 06/23/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 06/20/2025 06/24/2025
LOCATE COMPLETE 06/20/2025 06/24/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 06/20/2025 06/24/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 06/20/2025 06/25/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON HOLD 06/20/2025 06/25/2025
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please provide a right of way agreement for paver driveway. Once electronic copy is approved we will ask for the original

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 02/12/2026
REINSPECTION RESIDENTIAL ¤40.00 02/09/2026
WATER- TURN ON ¤100.00 07/11/2025
ADJUSTMENT 10% (¤166.09) 07/11/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 07/11/2025
INSPECTION - RESIDENTIAL ¤1,270.50 07/11/2025
PLAN REVIEW - RESIDENTIAL ¤360.36 07/11/2025
FC IMPACT FEE EMS ¤124.00 07/11/2025
IMPACT FEE FIRE ¤869.02 07/11/2025
FC IMPACT FEE LAW ENFORCEMENT ¤436.00 07/11/2025
FC IMPACT FEE LIBRARY ¤536.00 07/11/2025
IMPACT FEE PARKS ¤3,656.02 07/11/2025
IMPACT FEE SCHOOL ¤10,900.00 07/11/2025
RECORDING FEE REIMBURSE DOC ¤44.00 07/11/2025
IMPACT FEE TRANSPORTATION ¤2,974.00 07/11/2025
PEP TANK INSTALL ¤1,513.48 07/11/2025
WASTEWATER MAIN EXTENSION IMPA ¤4,770.00 07/11/2025
SURCHARGE FS 533.721 ¤14.95 07/11/2025
SURCHARGE - FS 468.631 ¤22.42 07/11/2025
SW ENG - FOUNDATION SURVEY ¤20.00 07/11/2025
SW ENG INSPECTION 80 ¤80.00 07/11/2025
SW ENG PRE APRON ¤30.00 07/11/2025
SW ENG - REVIEW 20 ¤20.00 07/11/2025
SW ENG RES REVIEW 200 ¤200.00 07/11/2025
WATER METER W/ TAP ¤4,653.86 07/11/2025
SEWER CREDIT (¤1,700.00) 07/11/2025
WASTEWATER PERM INSPECTION ¤80.00 07/11/2025
WASTEWATER PERM REVIEW ¤100.00 07/11/2025
SEWER CAPITAL FACILITY ¤8,830.00 07/11/2025
WATER CAPITAL FACILITY FEE ¤7,580.98 07/11/2025
WATER PERMIT INSPECTION ¤80.00 07/11/2025
WATER MAIN EXTENSION IMPACT ¤1,834.54 07/11/2025
SITE PLAN 30 ¤30.00 07/11/2025
Fees Total Due: ¤0.00 Total Paid: ¤49,374.04