I want to search for...
Permit #2025060907
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7023-00090-0010 |
| PATIO/DECK (NO ROOF) : 1375 sqft |
| Total Square Footage: 1375 sqft |
| Block: 00090 |
| Subdivision: 7023 - |
| Job Phone: 838-684-6512 X9 |
| Location Address: 8 WHITCOCK LN |
| Type: PO - POOL |
| Issue Date: 07/08/2025 |
| NOC: RECORDED |
| Applicant name: SAMANTHA JESSICA ALEXANDER |
| Owner: PLACZKIEWICZ-RAJSKI SZYMON PIOTR & STEVEN ROBERT R |
|
Address 8 WHITCOCK LN PALM COAST, FL 32164 |
| Lot: 0010 |
| Contracted Stated Job Value: ¤100,000.00 |
| Job Description: swimming pool & screen enclosure |
| Type: CN |
Contractor
AFFORDABLE POOLS INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3438 LONGLEAF ROAD , |
CPC1460092 (Exp: 08/31/2026) | 838-684-6512 X9 |
Sub Contractors
TODD MICHAEL ORIE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
560 S. YONGE ST. ORMOND BEACH, FL 32174 |
CBC036417 (Exp: 08/31/2026) | (386)673-4589 | (386)673-8045 |
COLE ROBERT WARD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1637 CORDOVA AVE HOLLY HILL, FL 32117 |
EC13012348 (Exp: 08/31/2026) | 386-506-9925 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 01/28/2026 | Disapproved - NO FEE | MKRASKI |
| Note: 1/28/26 1. Heater requires 4 tie downs FBC M1401.1 ***Alarms were tested*** 1/16/26 1. GFCI protection required on heater/blower circuit FBC 4501.16/NEC 680.21(C)/NEC 680.22 2. Heater requires 4 tie downs FBC M1401.1 3. Alarm not installed in pool FBC 4501.17.1.9 4. No plans on site FBC 107.3.1 1/14/26 1. Knocked and rang door bell, no answer, No cars in driveway. Gates are closed with signs saying beware of dog. Need access to back yard for inspection. | |||
| POOL FINAL | 01/28/2026 | FINAL APPROVED | MKRASKI |
| POOL FINAL | 01/16/2026 | Disapproved - NO FEE | MKRASKI |
| Note: 1/16/26 1. GFCI protection required on heater/blower circuit FBC 4501.16/NEC 680.21(C)/NEC 680.22 2. Heater requires 4 tie downs FBC M1401.1 3. Alarm not installed in pool FBC 4501.17.1.9 4. No plans on site FBC 107.3.1 1/14/26 1. Knocked and rang door bell, no answer, No cars in driveway. Gates are closed with signs saying beware of dog. Need access to back yard for inspection. | |||
| POOL FINAL | 01/14/2026 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Knocked and rang door bell, no answer, No cars in driveway. Gates are closed with signs saying beware of dog. Need access to back yard for inspection. | |||
| ROW - FINAL INSPECTION | 01/13/2026 | APPROVED | FSLADISH |
| Note: 1/13/26 REQUIRED CORRECTION COMPLETED AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. _______________________________________________________________________________________________________________________________ 12/30/2025 - PREVIOUS INSPECTION NOTES 12-30-25 TPOLACEK*** I HAVE PAINTED THE CWENTER LOINE OF SWALE AT 8' AS REQUIRED BY COPC RESIDENTAIL SWALE DETAIL. I HAVE ALSO ATTACHED A PHOTO OF THE DETAIL TO THE PERMIT FOR REFERENCE. SWALE MUST BE CORRECTED BEFORE FINAL ROW INSPECTION WILL BE APPROVED. Inspector Notes from Inspection 9465 12/23/24 WENT OUT ON SITE AND WALKED THIS PROPERTY. I BELIEVE THE 28.44 SHOT WAS TAKEN IN A LOW SPOT AS IN THE FIELD THIS AREA APPEARS TO HAVE POSITIVE FORWARD DRAINAGE. SPOKE WITH THE HOMEOWNER WHO INDICATED THAT HE HAS NOT HAD ANY ADVERSE DRAINAGE SITUATIONS. I AM GOING TO APPROVE THIS FIELD SURVEY AS NOTED AS IT IS REALLY ONLY ONE ELEVATION SHOT THAT DOEN'T SEEM TO MATCH THE SURROUNDING SHOTS. ***INSPECTORS NOTE. SPOKE WITH TOMMY THE LANDSCAPE SUB AND LET HIM KNOW THE FRONT SWALE WILL NEED CORRECTING AND THAT IT MUST CONFORM TO THE COPC SWALE DIAGRAM AND RETURNED TO AS GOOD OR BETTER CONDITION WITH SOD AT MATCHING GRADE AND SWALE CENTERED BEFORE ROW FINAL PASSAGE. *** Inspector Notes from Inspection 9463 12/23/24 WENT OUT ON SITE AND WALKED THIS PROPERTY. I BELIEVE THE 28.44 SHOT WAS TAKEN IN A LOW SPOT AS IN THE FIELD THIS AREA APPEARS TO HAVE POSITIVE FORWARD DRAINAGE. SPOKE WITH THE HOMEOWNER WHO INDICATED THAT HE HAS NOT HAD ANY ADVERSE DRAINAGE SITUATIONS. I AM GOING TO APPROVE THIS SURVEY AS NOTED AS IT IS REALLY ONLY ONE ELEVATION SHOT THAT DOEN'T SEEM TO MATCH THE SURROUNDING SHOTS. 12/22/2025 - PREVIOUS INSPECTION NOTES 12/22/25 YOU DO NOT HAVE POSITIVE FLOW LEFT OFF OF THE REAR OF POOL AS INDICATED ON YOUR SITE PLAN.. SEE PHOTO FOR REFERENCE. REAR YARD DRAINAGE Section 300.01 C(6) V-16 "6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement." | |||
| U -UTILITY RESIDENTIAL FINAL | 12/30/2025 | FINAL APPROVED | BWRIGHT |
| ROW - FINAL INSPECTION | 12/30/2025 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: *** NOTES ADDED BY TPOLACEK 12/30/2025 2:22:08 PM *** 7 Pipe not 8 ft/5 ft from road edge or missing 22 degree Elbow Swale Plan #2 Swale Plan #2. The swale centerline is typically located 8 feet from the edge of pavement, 5 feet from e.o.p. in cul de sacs. Culverts in cul de sacs may require a 22.5° elbow. 12-30-25 TPOLACEK*** I HAVE PAINTED THE CWENTER LOINE OF SWALE AT 8' AS REQUIRED BY COPC RESIDENTAIL SWALE DETAIL. I HAVE ALSO ATTACHED A PHOTO OF THE DETAIL TO THE PERMIT FOR REFERENCE. SWALE MUST BE CORRECTED BEFORE FINAL ROW INSPECTION WILL BE APPROVED. Inspector Notes from Inspection 9465 12/23/24 WENT OUT ON SITE AND WALKED THIS PROPERTY. I BELIEVE THE 28.44 SHOT WAS TAKEN IN A LOW SPOT AS IN THE FIELD THIS AREA APPEARS TO HAVE POSITIVE FORWARD DRAINAGE. SPOKE WITH THE HOMEOWNER WHO INDICATED THAT HE HAS NOT HAD ANY ADVERSE DRAINAGE SITUATIONS. I AM GOING TO APPROVE THIS FIELD SURVEY AS NOTED AS IT IS REALLY ONLY ONE ELEVATION SHOT THAT DOEN'T SEEM TO MATCH THE SURROUNDING SHOTS. ***INSPECTORS NOTE. SPOKE WITH TOMMY THE LANDSCAPE SUB AND LET HIM KNOW THE FRONT SWALE WILL NEED CORRECTING AND THAT IT MUST CONFORM TO THE COPC SWALE DIAGRAM AND RETURNED TO AS GOOD OR BETTER CONDITION WITH SOD AT MATCHING GRADE AND SWALE CENTERED BEFORE ROW FINAL PASSAGE. *** Inspector Notes from Inspection 9463 12/23/24 WENT OUT ON SITE AND WALKED THIS PROPERTY. I BELIEVE THE 28.44 SHOT WAS TAKEN IN A LOW SPOT AS IN THE FIELD THIS AREA APPEARS TO HAVE POSITIVE FORWARD DRAINAGE. SPOKE WITH THE HOMEOWNER WHO INDICATED THAT HE HAS NOT HAD ANY ADVERSE DRAINAGE SITUATIONS. I AM GOING TO APPROVE THIS SURVEY AS NOTED AS IT IS REALLY ONLY ONE ELEVATION SHOT THAT DOEN'T SEEM TO MATCH THE SURROUNDING SHOTS. 12/22/2025 - PREVIOUS INSPECTION NOTES 12/22/25 YOU DO NOT HAVE POSITIVE FLOW LEFT OFF OF THE REAR OF POOL AS INDICATED ON YOUR SITE PLAN.. SEE PHOTO FOR REFERENCE. REAR YARD DRAINAGE Section 300.01 C(6) V-16 "6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement." | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/23/2025 | APPROVED - AS NOTED | FSLADISH |
| Note: 12/23/24 WENT OUT ON SITE AND WALKED THIS PROPERTY. I BELIEVE THE 28.44 SHOT WAS TAKEN IN A LOW SPOT AS IN THE FIELD THIS AREA APPEARS TO HAVE POSITIVE FORWARD DRAINAGE. SPOKE WITH THE HOMEOWNER WHO INDICATED THAT HE HAS NOT HAD ANY ADVERSE DRAINAGE SITUATIONS. I AM GOING TO APPROVE THIS SURVEY AS NOTED AS IT IS REALLY ONLY ONE ELEVATION SHOT THAT DOEN'T SEEM TO MATCH THE SURROUNDING SHOTS. 12/22/2025 - PREVIOUS INSPECTION NOTES 12/22/25 YOU DO NOT HAVE POSITIVE FLOW LEFT OFF OF THE REAR OF POOL AS INDICATED ON YOUR SITE PLAN.. SEE PHOTO FOR REFERENCE. REAR YARD DRAINAGE Section 300.01 C(6) V-16 "6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement." | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 12/23/2025 | APPROVED - AS NOTED | FSLADISH |
| Note: 12/23/24 WENT OUT ON SITE AND WALKED THIS PROPERTY. I BELIEVE THE 28.44 SHOT WAS TAKEN IN A LOW SPOT AS IN THE FIELD THIS AREA APPEARS TO HAVE POSITIVE FORWARD DRAINAGE. SPOKE WITH THE HOMEOWNER WHO INDICATED THAT HE HAS NOT HAD ANY ADVERSE DRAINAGE SITUATIONS. I AM GOING TO APPROVE THIS FIELD SURVEY AS NOTED AS IT IS REALLY ONLY ONE ELEVATION SHOT THAT DOEN'T SEEM TO MATCH THE SURROUNDING SHOTS. ***INSPECTORS NOTE. SPOKE WITH TOMMY THE LANDSCAPE SUB AND LET HIM KNOW THE FRONT SWALE WILL NEED CORRECTING AND THAT IT MUST CONFORM TO THE COPC SWALE DIAGRAM AND RETURNED TO AS GOOD OR BETTER CONDITION WITH SOD AT MATCHING GRADE AND SWALE CENTERED BEFORE ROW FINAL PASSAGE. *** Inspector Notes from Inspection 9463 12/23/24 WENT OUT ON SITE AND WALKED THIS PROPERTY. I BELIEVE THE 28.44 SHOT WAS TAKEN IN A LOW SPOT AS IN THE FIELD THIS AREA APPEARS TO HAVE POSITIVE FORWARD DRAINAGE. SPOKE WITH THE HOMEOWNER WHO INDICATED THAT HE HAS NOT HAD ANY ADVERSE DRAINAGE SITUATIONS. I AM GOING TO APPROVE THIS SURVEY AS NOTED AS IT IS REALLY ONLY ONE ELEVATION SHOT THAT DOEN'T SEEM TO MATCH THE SURROUNDING SHOTS. 12/22/2025 - PREVIOUS INSPECTION NOTES 12/22/25 YOU DO NOT HAVE POSITIVE FLOW LEFT OFF OF THE REAR OF POOL AS INDICATED ON YOUR SITE PLAN.. SEE PHOTO FOR REFERENCE. REAR YARD DRAINAGE Section 300.01 C(6) V-16 "6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement." | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/22/2025 | Disapproved - NO FEE | FSLADISH |
| Note: 12/22/25 YOU DO NOT HAVE POSITIVE FLOW LEFT OFF OF THE REAR OF POOL AS INDICATED ON YOUR SITE PLAN.. SEE PHOTO FOR REFERENCE. REAR YARD DRAINAGE Section 300.01 C(6) V-16 "6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement." | |||
| ELECTRIC AND ALARM | 10/15/2025 | APPROVED - AS NOTED | MKRASKI |
| Note: 1. Bond wire must be protected from damage 2. All breakers for pool must be GFCI protected, minus low voltage lighting Check at final inspection | |||
| POOL DECK | 08/26/2025 | APPROVED | MKRASKI |
| STEEL AND GROUND | 07/21/2025 | APPROVED | MKRASKI |
| STEEL AND GROUND | 07/17/2025 | Disapproved - NO FEE | HCAMACHO |
| Note: 1. Pool plans show stairs on the shallow end of the pool. These stairs have not been framed with steel according to the plans submitted. Please see approved plans, Marked. |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 06/27/2025 | 07/01/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 06/27/2025 | 07/08/2025 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 06/27/2025 | 06/30/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BFLOOD | CANCEL | 06/20/2025 | 06/23/2025 |
| BLD | COMPLETE | 06/20/2025 | 06/23/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 06/20/2025 | 06/23/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | HOLD | 06/20/2025 | 06/24/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide gas riser diagram and list subcontractor or put note on plans "gas by others" | |||
| SW1 | COMPLETE | 06/20/2025 | 06/26/2025 |
| Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 06/20/2025 | 06/25/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| RSI REINSPECTION 1 | ¤35.00 | 01/13/2026 |
| SURCHARGE FS 533.721 | ¤2.41 | 07/08/2025 |
| SURCHARGE - FS 468.631 | ¤3.62 | 07/08/2025 |
| SW ENG INSPECTION 40 | ¤40.00 | 07/08/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 07/08/2025 |
| SITE PLAN 30 | ¤30.00 | 07/08/2025 |
| ADJUSTMENT 10% | (¤26.80) | 07/08/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 07/08/2025 |
| INSPECTION- POOL | ¤160.00 | 07/08/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤78.00 | 07/08/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤372.23 |