I want to search for...
Permit #2025060940
Permit Details
Status: COED
| Parcel Id: 07-11-31-7025-000G0-0190 |
| Block: 000G0 |
| Subdivision: 1228 - SOUTHWEST QUADRANT |
| Job Phone: 856-776-3930 |
| Location Address: 1000 PALM COAST PKWY SW |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 08/21/2025 |
| NOC: RECORDED |
| Applicant name: NEFTALI DEJESUS III |
| Owner: PATEL PALM COAST PLAZA LLC |
|
Address 644 CESERY BLVD #106 JACKSONVILLE, FL 32211 |
| Lot: 0190 |
| Contracted Stated Job Value: ¤25,000.00 |
| Job Description: UNIT 203 SPA REMODEL |
| Type: CN |
Contractor
1621 BUILDING AND REMODELING LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
389 PALM COAST PARKWAY SW UNIT 3-N PALM COAST, FL 32137 |
CGC1534626 (Exp: 08/31/2026) | 386-597-5984 |
Sub Contractors
DANIEL JOSEPH SCHWARZKOPF
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4601 E MOODY BLVD D6 PALM COAST, FL 32164 |
EC13010351 (Exp: 08/31/2026) | 386-313-6211 |
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
KYLE RODBOURN
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1325 W HWY 100 BUNNELL, FL 32110 |
CAC1821358 (Exp: 08/31/2026) | 386-586-9039 |
Inspection History
| Type | Request Date | Result | Inspector |
| HVAC FINAL | 12/03/2025 | APPROVED | HCAMACHO |
| Note: 11/25/2025 - PREVIOUS INSPECTION NOTES Need to rewrite test and banace report to show each station not each duct. Need to install louverd door and finish ceiling in AHU closet | |||
| BUILDING FINAL | 12/03/2025 | FINAL APPROVED | KSANDOE |
| Note: 11/25/2025 - PREVIOUS INSPECTION NOTES Fire extinguisher needs to be mounted and certified current. The one in place is dated FEB 2024. FBCA 306.2 306.3 Knee and Toe clearance. Vanity must be wall mounted and provide proper clearance for knee and toe under sink Inspector Notes from Inspection 3470 M.E.P met on site | |||
| FIRE FINAL | 12/03/2025 | APPROVED | RMARTIN |
| Note: 11/25/2025 - PREVIOUS INSPECTION NOTES Fire extinguisher needs to be certified and mounted. Need to have ceiling tiles installed | |||
| PLUMBING FINAL | 11/26/2025 | APPROVED | MGIBSON |
| Note: 11/25/2025 - PREVIOUS INSPECTION NOTES SINK FOR ''ADA'' BATHROOM IS NOT COMPLIANT | |||
| HVAC FINAL | 11/25/2025 | Disapproved - NO FEE | CPISCITELLI |
| Note: Need to rewrite test and banace report to show each station not each duct. Need to install louverd door and finish ceiling in AHU closet | |||
| PLUMBING FINAL | 11/25/2025 | Disapproved -FEE REQUIRED | MGIBSON |
| Note: SINK FOR ''ADA'' BATHROOM IS NOT COMPLIANT | |||
| U - UTILITY COMMERCIAL FINAL | 11/25/2025 | FINAL APPROVED | LFITZGERALD |
| FIRE FINAL | 11/25/2025 | Disapproved - NO FEE | RMARTIN |
| Note: Fire extinguisher needs to be certified and mounted. Need to have ceiling tiles installed | |||
| BUILDING FINAL | 11/25/2025 | Disapproved - NO FEE | KSANDOE |
| Note: Fire extinguisher needs to be mounted and certified current. The one in place is dated FEB 2024. FBCA 306.2 306.3 Knee and Toe clearance. Vanity must be wall mounted and provide proper clearance for knee and toe under sink Inspector Notes from Inspection 3470 M.E.P met on site | |||
| ELECTRIC FINAL | 11/20/2025 | APPROVED | RMARTIN |
| Note: 11/19/2025 - PREVIOUS INSPECTION NOTES Need GFCI protection on clothes dryer per NEC 210.8 B 11, Also need to close up the un-used openings in water the heater NEC 110.12 A | |||
| FIREWALL FINAL | 11/20/2025 | FINAL APPROVED | KSANDOE |
| FIREWALL PENETRATIONS | 11/20/2025 | APPROVED | KSANDOE |
| ABOVE CEILING | 11/20/2025 | APPROVED - AS NOTED | RMARTIN |
| Note: M.E.P met on site | |||
| ELECTRIC FINAL | 11/19/2025 | Disapproved - NO FEE | RMARTIN |
| Note: Need GFCI protection on clothes dryer per NEC 210.8 B 11, Also need to close up the un-used openings in water the heater NEC 110.12 A | |||
| ELECTRIC 2ND ROUGH | 10/22/2025 | APPROVED | RMARTIN |
| Note: 10/7/2025 - PREVIOUS INSPECTION NOTES need to have correct cut in boxes for the outlets between the unit walls. Plastic cut in boxes are for romex, can not drill holes in them and use for mc cable. Per NEC 314.3 | |||
| PLUMBING 2ND ROUGH | 10/22/2025 | APPROVED | MGIBSON |
| Note: 10/7/2025 - PREVIOUS INSPECTION NOTES PLAN CALLS FOR 4 CHAIRS AND ONLY THREE ARE PLUMBED, NEED TO FILE REVISION OMMITTING 4 TH CHAIR OR ADD IT TO PLUMBING RISER, ONLY ONE BACK MIXING VALVE VISIBLE ALSO NEED TO HAVE BACK FLOWS INSTALLED AT START OF HOT AND COLD WATER SUPPLY TO CHAIRS | |||
| HVAC ROUGH | 10/22/2025 | APPROVED - AS NOTED | CPISCITELLI |
| Note: Need to inspect dryer vent or ventless dryer on next inspection or HVAC final | |||
| FRAMING | 10/22/2025 | APPROVED | KSANDOE |
| Note: 10/7/2025 - PREVIOUS INSPECTION NOTES 1. Added partition walls do not match supplied plans or scope of work. Please submit revision showing walls as built and anchors used. 2. Studs in partition walls are over notched. FBC2318.1.10 | |||
| HVAC ROUGH | 10/07/2025 | CANCELLED BY APPLICANT | CPISCITELLI |
| PLUMBING 1ST ROUGH | 10/07/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: AFTER SPECKING WITH PLUMBING CONTRACTOR ABOUT ''DFU' IT IS ALLOWED BY PLUMBING CODE TO CATCH THIRTEEN FIXTURE UNITS ON 2'' DRAIN LINE, BUT OVER NOTCHED STUD ISN'T ALLOWWED, 40 % FOR BEARING WALLS AND 60 % ON NON BEARING WALLS | |||
| PLUMBING 2ND ROUGH | 10/07/2025 | CANCELLED BY APPLICANT | MGIBSON |
| Note: PLAN CALLS FOR 4 CHAIRS AND ONLY THREE ARE PLUMBED, NEED TO FILE REVISION OMMITTIN 4 TH CHAIR OR ADD IT TO PLUMBING RISER, ONLY ONE BACK MIXING VALVE VISIBLE ALSO NEED TO HAVE BACK FLOWS INSTALLED AT START OF HOT AND COLD WATER SUPPLY TO CHAIRS | |||
| ELECTRIC 2ND ROUGH | 10/07/2025 | Disapproved - NO FEE | RMARTIN |
| Note: need to have correct cut in boxes for the outlets between the unit walls. Plastic cut in boxes are for romex, can not drill holes in them and use for mc cable. Per NEC 314.3 | |||
| FRAMING | 10/07/2025 | Disapproved - NO FEE | KSANDOE |
| Note: 1. Added partition walls do not match supplied plans or scope of work. Please submit revision showing walls as built and anchors used. 2. Studs in partition walls are over notched. FBC2318.1.10 |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 10/14/2025 | 10/20/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 10/07/2025 | 10/10/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide wall detail on plans for over boring. 2. Provide new location of washer/dryer on plans 3. Show return out of office and supply out of middle area 4. Show how return from AHU will be rerouted and if closet for original washer location will be eliminated | |||
| PLUM | COMPLETE | 10/07/2025 | 10/10/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 08/21/2025 | 08/21/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| PLUM | COMPLETE | 08/20/2025 | 08/21/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 08/20/2025 | 08/21/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM REPEAT COMMENTS: 1. Provide Heatload Calculation per C403.2.1 FBC Energy Conservation 2023 2. Provide Ventilation calculation per Table 403.3.1.1 FBC Mechanical 2023 3. Provide note on plan for test and balance showing 50 CFM at each pedicure station per C403.3.1.1 FBC Mechanical 2023 4. Provide duct layout showing supply, return, fresh air, and exhaust with proposed changes. 107.2.1 FBC 5. ok 6. ok 6. ok | |||
| ELEC | COMPLETE | 07/07/2025 | 07/10/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| FI1 | COMPLETE | 07/07/2025 | 07/10/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 07/07/2025 | 07/09/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| PLUM | HOLD | 07/07/2025 | 07/09/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM separate plumbing plan pages | |||
| MECH | HOLD | 07/07/2025 | 07/09/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM REPEAT COMMENTS: 1. Provide Heatload Calculation per C403.2.1 FBC Energy Conservation 2023 2. Provide Ventilation calculation per Table 403.3.1.1 FBC Mechanical 2023 3. Provide note on plan for test and balance showing 50 CFM at each pedicure station per C403.3.1.1 FBC Mechanical 2023 4. Provide duct layout showing supply, return, fresh air, and exhaust with proposed changes. 107.2.1 FBC 5. Provide exhaust fan details for nail ventilation system. 107.2.1FBC 6. ok 6. List mechanical subcontractor | |||
| BLD | HOLD | 06/20/2025 | 07/01/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide dimensions of hallway. 2. Provide ceiling height. Do walls go all theway to ceiling? 3. Door cannot open into path of egress. Door need to to open into room. Change door on plans | |||
| DSD | COMPLETE | 06/20/2025 | 06/23/2025 |
| Note: Released By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 06/20/2025 | 06/30/2025 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit detail of how you will connect the wafer lights to the grid. You can not just cut them into the ceiling tile. NEC 2020 410.36 (B) 2. Label new room. | |||
| FI1 | HOLD | 06/20/2025 | 06/30/2025 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Show location of fire extinguishers. 2. Show location of all ext signs and emergency lighting. | |||
| MECH | HOLD | 06/20/2025 | 07/01/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide Heatload Calculation per C403.2.1 FBC Energy Conservation 2023 2. Provide Ventilation calculation per Table 403.3.1.1 FBC Mechanical 2023 3. Provide note on plan for test and balance showing 50 CFM at each pedicure station per C403.3.1.1 FBC Mechanical 2023 4. Provide duct layout showing supply, return, fresh air, and exhaust with proposed changes. 107.2.1 FBC 5. Provide exhaust fan details for nail ventilation system. 107.2.1FBC 6. If walls go all the way to ceiling, then provide return air on duct layout for new room 601.6 FBC Mechanical 2023 6. List mechanical subcontractor | |||
| PLUM | HOLD | 06/20/2025 | 07/01/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide location of cleanouts on DWV riser diagram. 708 FBC Plumbing 2023 2. Provide Riser diagram for water distribution piping. Include material type and size.605/606 FBC Plumbing 2023 3. Provide water temp limiting device for pedicure chairs.423.3 FBC Plumbing 2023 4. Provide backflow preventor for water connection for pedicure chairs. Include manufacturer and model. 608.1 FBC Plumbing 2023 | |||
| UD1 | COMPLETE | 06/20/2025 | 06/26/2025 |
| Note: Released By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM | |||
| UD2 | COMPLETE | 06/20/2025 | 06/23/2025 |
| Note: Released By: DAN LEMONCELLO - - 1) no grease trap needed |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION - COMMERCIAL | ¤60.00 | 12/02/2025 |
| PLAN REVIEW - REVISION | ¤32.50 | 11/25/2025 |
| CONTRACTOR CHANGE | ¤20.00 | 08/21/2025 |
| SURCHARGE FS 533.721 | ¤2.89 | 08/21/2025 |
| SURCHARGE - FS 468.631 | ¤4.34 | 08/21/2025 |
| SITE PLAN 30 | ¤30.00 | 08/21/2025 |
| ADJUSTMENT 10% | (¤32.13) | 08/21/2025 |
| ADMINISTRATIVE - COMMERCIAL | ¤75.00 | 08/21/2025 |
| INSPECTION COMMERCIAL | ¤175.00 | 08/21/2025 |
| INSPECTION - FIRE COMMERCIAL | ¤6.25 | 08/21/2025 |
| PLAN REVIEW - COMMERCIAL | ¤65.00 | 08/21/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤438.85 |