I want to search for...

Permit #2025061138

Permit Details

Status: INSPECT

Parcel Id: 07-11-31-7013-00180-0040
Block: 00180
Subdivision: 7013 -
Job Phone: 561-329-2819
Location Address: 79 BRUNETT LN
Type: WD - WINDOWS/DOORS
Issue Date: 06/26/2025
NOC: Unknown
Applicant name: SCOTT L BERMAN
Owner: PONTES ALBERT M

Address

79 BRUNETT LANE

PALM COAST, FL 32137

Lot: 0040
Contracted Stated Job Value: ¤29,601.00
Job Description: 1 IMPACT DOOR AND 9 IMPACT WINDOWS.
Type: CN

Contractor

FLORIDA WINDOW & DOOR
Status Location Address State License Number Phone
ACTIVE

1125 N DIXIE HIGHWAY

LAKE WORTH, FL 33460

CGC1509450 (Exp: 08/31/2026) 561-228-1884

Inspection History

Type Request Date Result Inspector
FINAL - BUILDING MISC 10/22/2025 Disapproved - NO FEE KSANDOE
Note: 1. Screens for windows 2 and 3 do not fit and are too small for the application. 2. Rear Sliding door installation instructions require bucking inside rough opening. Upon inspection it does not appear there is space for bucking to be installed on either side. The gap above the door on the left side is greater than the maximum ¼”. 3. Installation instructions call for anchors in top and bottom door tracks. No such anchors have been installed. 4. Anchors used in all windows must be countersunk. 5. Window numbers 2 and 3 appear to be used. Used equipment and devices shall not be reused unless approved by the Building Official FRC [A]104.9.1 6. Window number 8 is difficult to operate. Gets stuck when moving to full open position. 7. Window number 6 is missing aluminum retention clip at top left. 8. Window glazing throughout does not appear to match approved product. FL# matches but installed glazing inside frame does not appear to match minimum thickness indicated in identification/installation packet.
FINAL - BUILDING MISC 10/15/2025 FINAL APPROVED FWILLIS
Note: TWO SCREENS IN THE KITCHEN WINDOWS DO NOT FIT. PLEASE REPLACE TO THE CORRECT SIZE.
FINAL - BUILDING MISC
Note: 10/22/2025 - PREVIOUS INSPECTION NOTES 1. Screens for windows 2 and 3 do not fit and are too small for the application. 2. Rear Sliding door installation instructions require bucking inside rough opening. Upon inspection it does not appear there is space for bucking to be installed on either side. The gap above the door on the left side is greater than the maximum ¼”. 3. Installation instructions call for anchors in top and bottom door tracks. No such anchors have been installed. 4. Anchors used in all windows must be countersunk. 5. Window numbers 2 and 3 appear to be used. Used equipment and devices shall not be reused unless approved by the Building Official FRC [A]104.9.1 6. Window number 8 is difficult to operate. Gets stuck when moving to full open position. 7. Window number 6 is missing aluminum retention clip at top left. 8. Window glazing throughout does not appear to match approved product. FL# matches but installed glazing inside frame does not appear to match minimum thickness indicated in identification/installation packet.

Review History

Department Status Date In Date Out
BLD COMPLETE 06/25/2025 06/25/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 10% (¤11.25) 06/26/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 06/26/2025
INSPECTION - RESIDENTIAL ¤82.50 06/26/2025
SURCHARGE FS 533.721 ¤2.00 06/26/2025
SURCHARGE - FS 468.631 ¤2.00 06/26/2025
EXTENSION ¤40.00
EXTENSION ¤40.00
Fees Total Due: ¤80.00 Total Paid: ¤105.25