I want to search for...

Permit #2025070554

Permit Details

Status: COED

Parcel Id: 42-10-30-3210-00000-1160
CONDITIONED SPACE: 2250 sqft
OPENED PORCH (WITH ROOF) : 33 sqft
OPENED PORCH (WITH ROOF) : 226 sqft
GARAGE: 566 sqft
Total Square Footage: 3075 sqft
Block: 00000
Subdivision: 2094 - CONSERVATORY AT HAMMOCK BEACH
Job Phone: 386-236-4133
Location Address: 622 MAHOGANY RUN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 08/18/2025
NOC: RECORDED
Applicant name: LEONARDO CIRO SANCLEMENTE
Owner: VOLUSIA RESIDENTIAL CONSTRUCTION LLC

Address

2379 BEVILLE ROAD

DAYTONA BEACH, FL 32119

Lot: 1160
Contracted Stated Job Value: ¤319,909.00
Job Description: SINGLE FAMILY RESIDENCE.
Type: CN

Contractor

VOLUSIA RESIDENTIAL CONSTRUCTION, LLC
Status Location Address State License Number Phone
ACTIVE

2379 BEVILLE RD

DAYTONA BEACH, FL 32119

CBC1262114 (Exp: 08/31/2026) 386-236-4133

Sub Contractors

TIMUR ISPARYAN
Status Location Address State License Number Phone Fax
ACTIVE

3665 SPRINK PARK ROAD

JACKSONVILLE , FL 32207

CMC1249968 (Exp: 08/31/2026) 904-245-1818 904-337-1910
STEPHEN COURTEAUX
Status Location Address State License Number Phone Fax
ACTIVE

85 North Yonge Street

Ormond Beach, FL 32174

EC13001748 (Exp: 08/31/2026) (386) 672-4900 386-676-7472
HUGH MACDONALD
Status Location Address State License Number Phone
ACTIVE

10825 TOM FOLSOM ROAD, SUITE A

THONOTOSASSA, FL 33592

CCC1329562 (Exp: 08/31/2026) 813-986-4968
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 03/23/2026 FINAL APPROVED MCONTRYMAN
U-CROSS CONNECTION 03/23/2026 APPROVED - AS NOTED BHAINES
Note: No CC.
U -UTILITY RESIDENTIAL FINAL 03/23/2026 FINAL APPROVED BHAINES
ROW - FINAL APRON (AFTER POUR) 03/18/2026 APPROVED EMADISON
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 03/18/2026 APPROVED EMADISON
ROW FIELD SURVEY /GRADING CERTIFICATION 03/18/2026 APPROVED EMADISON
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - STORMWATER FINAL 03/18/2026 APPROVED EMADISON
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ELECTRIC - EARLY POWER 03/03/2026 APPROVED MCONTRYMAN
ROW- PRE-APRON (PRE-POUR) 02/18/2026 APPROVED TPOLACEK
Note: READY FOR PAVERS AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 2/12/2026 - PREVIOUS INSPECTION NOTES CORRECTIONS MADE TO FORMS READY TO POUR APRON AND PAVER RESTRAINTS ONLY. BEFORE NEXT PRE POUR ALL PAVER BASE NEEDS TO SPREAD AND COMPACTED TO CITY'S STANDARDS WITH NO PAVERS LAID AT THE TIME OF THE INSPECTION. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. ----------------------------------------------------------------------------------------- 2/11/2026 - PREVIOUS INSPECTION NOTES 02-11-26 TPOLACEK*** APRON FLARE SHOULD BE 36" WIDE FROM EDGE OF DRIVEWAY OUT AND START 5' FROM EDGE OF CURB. ADDRESS MUST BE CLEARLY POSTED ON JOB BOX OR FRONT OF STRUCTURE. THE ADDRESS MUST BE POSTED AND VISIBLE TO INSPECTORS Florida Building Code-;. Building Section 501.2 THE ADDRESS MUST BE POSTED AND VISIBLE TO INSPECTORS.  IF THE ADDRESS IS NOT VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS, AND A REINSPECTION FEE WILL BE ISSUED.  Florida Building Code-;. Building Section 501.2
ROW- PRE-APRON (PRE-POUR) 02/12/2026 PARTIALLY APPROVED PFLANAGAN
Note: CORRECTIONS MADE TO FORMS READY TO POUR APRON AND PAVER RESTRAINTS ONLY. BEFORE NEXT PRE POUR ALL PAVER BASE NEEDS TO SPREAD AND COMPACTED TO CITY'S STANDARDS WITH NO PAVERS LAID AT THE TIME OF THE INSPECTION. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. ----------------------------------------------------------------------------------------- 2/11/2026 - PREVIOUS INSPECTION NOTES 02-11-26 TPOLACEK*** APRON FLARE SHOULD BE 36" WIDE FROM EDGE OF DRIVEWAY OUT AND START 5' FROM EDGE OF CURB. ADDRESS MUST BE CLEARLY POSTED ON JOB BOX OR FRONT OF STRUCTURE. THE ADDRESS MUST BE POSTED AND VISIBLE TO INSPECTORS Florida Building Code-;. Building Section 501.2 THE ADDRESS MUST BE POSTED AND VISIBLE TO INSPECTORS.  IF THE ADDRESS IS NOT VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS, AND A REINSPECTION FEE WILL BE ISSUED.  Florida Building Code-;. Building Section 501.2
ROW- PRE-APRON (PRE-POUR) 02/11/2026 Disapproved - NO FEE TPOLACEK
Note: 02-11-26 TPOLACEK*** APRON FLARE SHOULD BE 36" WIDE FROM EDGE OF DRIVEWAY OUT AND START 5' FROM EDGE OF CURB. ADDRESS MUST BE CLEARLY POSTED ON JOB BOX OR FRONT OF STRUCTURE. THE ADDRESS MUST BE POSTED AND VISIBLE TO INSPECTORS Florida Building Code-;. Building Section 501.2 THE ADDRESS MUST BE POSTED AND VISIBLE TO INSPECTORS.  IF THE ADDRESS IS NOT VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS, AND A REINSPECTION FEE WILL BE ISSUED.  Florida Building Code-;. Building Section 501.2
LATH/BRICK/ WATER BARRIER 01/23/2026 APPROVED MCONTRYMAN
Note: 1/22/2026 - PREVIOUS INSPECTION NOTES 1/22/26 1. Water barrier and lath required around exterior outlet boxes and hose bibs 1/20/26 1. Added note that new lintel was cut due to rebar downrod in blocking and lintel fill with solid concrete once put in place. Job is good to go 1/9/26 1. Door Precast Header going out to the Lanai has been cut out at the bottom about 2" and the steel has been cut.The structual integrity of the precast has been comprimised. Need a letter/Revision to address this issue. FBC [A]107.4 2. Door out to the Lanai is not installed. 3. Arch window in the front, the top is not anchored. Added note that new lintel was cut due to rebar downrod in blocking and lintel fill with solid concrete once put in place. Job is good to go 1/20/26 Must have fixed by next inspection to avoid fees 1. Mortar joints well exceed allowable spacing for around new lintel for lenai. Solid blocking must be cut to fill any gaps larger than 1/2" (3/8" for block) FBCR 606.3.1 1/9/2026 - PREVIOUS INSPECTION NOTES 1. Door Precast Header going out to the Lanai has been cut out at the bottom about 2" and the steel has been cut.The structual integrity of the precast has been comprimised. Need a letter/Revision to address this issue. FBC [A]107.4 2. Door out to the Lanai is not installed. 3. Arch window in the front, the top is not anchored.
LATH/BRICK/ WATER BARRIER 01/22/2026 Disapproved - NO FEE MKRASKI
Note: 1/22/26 1. Water barrier and lath required around exterior outlet boxes and hose bibs 1/20/26 1. Added note that new lintel was cut due to rebar downrod in blocking and lintel fill with solid concrete once put in place. Job is good to go 1/9/26 1. Door Precast Header going out to the Lanai has been cut out at the bottom about 2" and the steel has been cut.The structual integrity of the precast has been comprimised. Need a letter/Revision to address this issue. FBC [A]107.4 2. Door out to the Lanai is not installed. 3. Arch window in the front, the top is not anchored. Added note that new lintel was cut due to rebar downrod in blocking and lintel fill with solid concrete once put in place. Job is good to go 1/20/26 Must have fixed by next inspection to avoid fees 1. Mortar joints well exceed allowable spacing for around new lintel for lenai. Solid blocking must be cut to fill any gaps larger than 1/2" (3/8" for block) FBCR 606.3.1 1/9/2026 - PREVIOUS INSPECTION NOTES 1. Door Precast Header going out to the Lanai has been cut out at the bottom about 2" and the steel has been cut.The structual integrity of the precast has been comprimised. Need a letter/Revision to address this issue. FBC [A]107.4 2. Door out to the Lanai is not installed. 3. Arch window in the front, the top is not anchored.
INSULATION 01/22/2026 APPROVED MKRASKI
Note:
ALL ROUGH 01/20/2026 APPROVED - AS NOTED MCONTRYMAN
Note: *** NOTES ADDED BY MCONTRYMAN 1/20/2026 3:13:24 PM *** Added note that new lintel was cut due to rebar downrod in blocking and lintel fill with solid concrete once put in place. Job is good to go 1/20/26 Must have fixed by next inspection to avoid fees 1. Mortar joints well exceed allowable spacing for around new lintel for lenai. Solid blocking must be cut to fill any gaps larger than 1/2" (3/8" for block) FBCR 606.3.1 1/9/2026 - PREVIOUS INSPECTION NOTES 1. Door Precast Header going out to the Lanai has been cut out at the bottom about 2" and the steel has been cut.The structual integrity of the precast has been comprimised. Need a letter/Revision to address this issue. FBC [A]107.4 2. Door out to the Lanai is not installed. 3. Arch window in the front, the top is not anchored.
LATH/BRICK/ WATER BARRIER 01/20/2026 CANCELLED BY APPLICANT MCONTRYMAN
Note: Cancelled via phone call at 8:08am
ELECTRIC-TUG 01/09/2026 APPROVED HCAMACHO
ALL ROUGH 01/09/2026 Disapproved - NO FEE HCAMACHO
Note: 1. Door Precast Header going out to the Lanai has been cut out at the bottom about 2" and the steel has been cut.The structual integrity of the precast has been comprimised. Need a letter/Revision to address this issue. FBC [A]107.4 2. Door out to the Lanai is not installed. 3. Arch window in the front, the top is not anchored.
ROOF VALLEY & METAL 12/17/2025 APPROVED HCAMACHO
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/11/2025 APPROVED HCAMACHO
Note: 12/10/2025 - PREVIOUS INSPECTION NOTES Arrived at 10:30 and the framers were still working on the house. Not ready for inspection.
WALL SHEATHING 12/11/2025 APPROVED HCAMACHO
Note: 12/10/2025 - PREVIOUS INSPECTION NOTES Arrived at 10:30 and the framers were still working on the house. Not ready for inspection.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/10/2025 Disapproved - NO FEE HCAMACHO
Note: Arrived at 10:30 and the framers were still working on the house. Not ready for inspection.
WALL SHEATHING 12/10/2025 Disapproved - NO FEE HCAMACHO
Note: Arrived at 10:30 and the framers were still working on the house. Not ready for inspection.
TIE BEAM / LINTEL 12/01/2025 APPROVED HCAMACHO
MONOLITHIC SLAB 11/20/2025 APPROVED HCAMACHO
PLUMBING 1ST ROUGH UNDERGROUND 11/17/2025 APPROVED - AS NOTED MGIBSON
Note: WATER SERVICE NOT RAN YET
GRAVITY SEWER TEST 11/17/2025 APPROVED MGIBSON
SEWER TIE IN 11/17/2025 APPROVED MGIBSON
FORMBOARD SURVEY (OFFICE USE ONLY) 11/14/2025 APPROVED PFLANAGAN
WATER METER INSTALLATION REQUEST 11/14/2025 APPROVED CBOWERMASTER
ROW- PROJECT STATUS 10/15/2025 APPROVED - AS NOTED RRICKS
Note: 10/17/2025 Met with builder to discuss FFE issues. Agreed that 25.30' aligns with the master plan. Builder will submit a revised grading plan with the new proposed FFE and grades for review. If there are any questions call Rodney

Review History

Department Status Date In Date Out
BLD COMPLETE 01/20/2026 01/20/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SW1 COMPLETE 12/03/2025 12/03/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 12/03/2025 12/03/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SW1 HOLD 12/02/2025 12/03/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM FFE for lot 113 is off by 1' from the approved master plan. This was mentioned on the formboard survey. Please confirm the FFEs and resubmit foundation survey.
ZON COMPLETE 12/02/2025 12/02/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SW1 COMPLETE 11/13/2025 11/14/2025
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 11/13/2025 11/13/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SW1 COMPLETE 11/10/2025 11/13/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Approved, please submit formboard survey.
SW1 HOLD 11/06/2025 11/07/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM The FFE of lot 113 does not match approved grading plan and is off by a foot. Please confirm formboards, benchmark, and adjacent improved FFEs.
ZON COMPLETE 11/06/2025 11/06/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
SW1 COMPLETE 10/28/2025 10/29/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 10/28/2025 10/29/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
SW1 HOLD 10/03/2025 10/06/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Formboard comments: - FFE does not match approved grading plans. - Dimensions at the rear of home does not match approved grading plan.
ZON COMPLETE 10/03/2025 10/06/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 09/22/2025 09/25/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
ZON COMPLETE 09/22/2025 09/22/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 09/08/2025 09/11/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
ELEC COMPLETE 09/08/2025 09/11/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 09/08/2025 09/08/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 09/08/2025 09/08/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SW1 COMPLETE 08/14/2025 08/14/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
BLD COMPLETE 08/06/2025 08/11/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SW1 HOLD 08/06/2025 08/07/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM - Please label and identify benchmarks on grading plan. - Please provide proposed elevations on along the property lines on a 20' grid. - When proposing common swale along adjacent lot there shall be a minimum of 0.3' fall from the top of the swale to the bottom of the swale. Please note that proposed grades along improved lots shall match existing grades within ± 0.1' Please feel free to call or email me if there are any questions or concerns.
BADMIN COMPLETE 07/15/2025 07/22/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD HOLD 07/15/2025 07/22/2025
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Product Approval List structural components to be used.
CUSVC COMPLETE 07/15/2025 07/18/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 07/15/2025 07/22/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/15/2025 07/16/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 07/15/2025 07/16/2025
LOCATE COMPLETE 07/15/2025 07/16/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 07/15/2025 07/17/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 07/15/2025 07/23/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM COPC Technical Manual Section - 200.01.A.b(1) -Finished Floor Elevation (FFE) of the living area of all improved structures on adjacent (left and right sides) lots. If there is no improved property on the left or right, the closest improved adjacent FFE shall be provided. 2) The elevations on all adjacent properties at a minimum of 20-foot intervals on a 10-foot offset outside the property lines. (3) The elevations at 20-foot intervals along all property lines. There must be sufficient elevation shots to indicate the proposed drainage pattern. (4) The elevations interior to the lot at no greater than a 20-foot grid. (5) Elevations at the lot corners, at foundation corners, along all sides of the proposed building, and 10 feet off the proposed building are required in addition to the 20-foot grid. COPC Technical Manual Section - 200.01A.1.b.(11) - The Finished Floor Elevation (FFE) of the proposed home’s living space, attached and / or detached garages, attached and / or detached patios, lanais, porches, exterior door landings, sidewalks and similar shall be shown. Unattached pads solely for the purpose of supporting AC, LPG and pool equipment are exempt. - All attached garages, patios, lanais, porches, exterior door landings, sidewalks and similar shall show an FFE of not less than 0.33 tenths of a foot (4 inches) lower than the FFE of the home’s living space. Exception: Access ramps may rise to the FFE of the interior living space for the width of the ramp only. - All attached patios, lanais, porches, exterior door landings, sidewalks and similar and those located within 10 feet of the proposed home shall show a minimum slope perpendicular to the foundation of not less than 2%. Attached and detached garages shall show a positive slope to facilitate drainage towards the vehicle entrance. - Please provide an on-site, easily identifiable benchmark referenced to NAVD 1988 (e.g., fire hydrant, nail in power pole [1 nail per power pole], and manhole covers). Pavement nails will not be accepted unless none of the above locations are available on site (nails in pavement should not be set inside a road cut). (The benchmark must be maintained throughout the construction cycle by the contractor and will be used in the swale plan and Final Survey). COPC Technical Manual Section - 200.01A.1.b.(6) - The road centerline (RCL) and edge of pavement (EOP) elevations (also on a 20-ft grid) for roadways adjacent to and along all property lines, including EOP in cul-de-sacs at 9, 12, and 3 o’clock positions - Please include lot numbers as well - Please depict demensions of home on grading plan. This will help ensure that the formboard survey matches the approved grading plan.
ZON COMPLETE 07/15/2025 07/16/2025
Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM
URB COMPLETE 07/15/2025 07/21/2025
Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 03/25/2026
RSI GENERAL INSPECTION 32.50 ¤32.50 03/25/2026
SURCHARGE FS 533.721 ¤13.96 08/18/2025
SURCHARGE - FS 468.631 ¤20.94 08/18/2025
SW ENG - FOUNDATION SURVEY ¤20.00 08/18/2025
SW ENG INSPECTION 80 ¤80.00 08/18/2025
SW ENG PRE APRON ¤30.00 08/18/2025
SW ENG - REVIEW 20 ¤20.00 08/18/2025
SW ENG RES REVIEW 200 ¤200.00 08/18/2025
WASTEWATER PERM INSPECTION ¤80.00 08/18/2025
WASTEWATER PERM REVIEW ¤25.00 08/18/2025
WATER PERMIT REVIEW ¤25.00 08/18/2025
SITE PLAN 30 ¤30.00 08/18/2025
FC IMPACT FEE EMS ¤62.00 08/18/2025
IMPACT FEE FIRE ¤434.51 08/18/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 08/18/2025
FC IMPACT FEE LIBRARY ¤268.00 08/18/2025
IMPACT FEE PARKS ¤1,828.01 08/18/2025
IMPACT FEE SCHOOL ¤5,450.00 08/18/2025
IMPACT FEE TRANSPORTATION ¤3,502.00 08/18/2025
WATER METER W/OUT TAP ¤965.03 08/18/2025
WATER- TURN ON ¤50.00 08/18/2025
ADJUSTMENT 10% (¤155.14) 08/18/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 08/18/2025
INSPECTION - RESIDENTIAL ¤1,185.25 08/18/2025
PLAN REVIEW - RESIDENTIAL ¤336.18 08/18/2025
Fees Total Due: ¤0.00 Total Paid: ¤14,783.74