I want to search for...
Permit #2025071127
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7023-00130-0080 |
| Total Square Footage: 828 sqft |
| Block: 00130 |
| Subdivision: - |
| Job Phone: 385-793-2815 |
| Location Address: 3 WHITAKER PL |
| Type: AL - ALUMINUM SCREEN STRUCTURE |
| Issue Date: 08/01/2025 |
| NOC: RECORDED |
| Applicant name: RUDOLF F WOHLFARTH |
| Owner: QUASH SHELAH J TRUSTEE |
|
Address 3 WHITAKER PL PALM COAST, FL 32164 |
| Lot: 0080 |
| Contracted Stated Job Value: ¤25,056.00 |
| Job Description: rebuild screen enclosure, size for size |
| Type: CN |
Contractor
COURTESY SCREENING INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
PO BOX 350 171 BUNNELL , FL 32110 |
SCC131152889 (Exp: 08/31/2026) | 386-793-2815 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL - BUILDING MISC | 04/21/2026 | FINAL APPROVED | HCAMACHO |
| Note: 2/17/2026 - PREVIOUS INSPECTION NOTES 2/17/26 1. Header beam not proper size, supported or attached for span per details 2. Enclosure needs to be sealed where it meets stucco on both sides of attachment per detail 3. Door jams not attached properly per detail 9/18/25 1. Header over lani opening is cut almost all the way in half loosing all integirty to beam 2. Multiple locations screen needs to be trimmed 3. Seal all locations where enclosure meets stucco 4. Door jams not attached properly | |||
| FINAL - BUILDING MISC | 02/17/2026 | Disapproved - NO FEE | MKRASKI |
| Note: 2/17/26 1. Header beam not proper size, supported or attached for span per details 2. Enclosure needs to be sealed where it meets stucco on both sides of attachment per detail 3. Door jams not attached properly per detail 9/18/25 1. Header over lani opening is cut almost all the way in half loosing all integirty to beam 2. Multiple locations screen needs to be trimmed 3. Seal all locations where enclosure meets stucco 4. Door jams not attached properly | |||
| FINAL - BUILDING MISC | 09/18/2025 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 1. Header over lani opening is cut almost all the way in half loosing all integirty to beam 2. Multiple locations screen needs to be trimmed 3. Seal all locations where enclosure meets stucco 4. Door jams not attached properly |
Review History
| Department | Status | Date In | Date Out |
| BFLOOD | CANCEL | 07/29/2025 | 07/29/2025 |
| BLD | COMPLETE | 07/29/2025 | 08/01/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| RSI | COMPLETE | 07/29/2025 | 07/30/2025 |
| Note: Released By: FRANK SLADISH - (386)871-6113 - FSLADISH@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/29/2025 | 07/29/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EXTENSION | ¤40.00 | 02/16/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/16/2026 |
| SURCHARGE FS 533.721 | ¤2.00 | 08/01/2025 |
| SURCHARGE - FS 468.631 | ¤2.00 | 08/01/2025 |
| SITE PLAN 15 | ¤15.00 | 08/01/2025 |
| INSPECTION - ALUMINUM ENCLOSU | ¤60.00 | 08/01/2025 |
| PLAN REVIEW - MISC 32.50 | ¤32.50 | 08/01/2025 |
| ADJUSTMENT 10% | (¤12.25) | 08/01/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 08/01/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤209.25 |