I want to search for...
Permit #2025071194
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7020-00130-0210 |
| Block: 00130 |
| Subdivision: 7020 - |
| Job Phone: 904-610-4499 |
| Location Address: 29 LAGO VISTA PL |
| Type: ME - MECHANICAL |
| Issue Date: 07/30/2025 |
| NOC: Unknown |
| Applicant name: ANTHONY MODESTO SCHREIBER |
| Owner: SHI YANG |
|
Address 29 LAGO VISTA PLACE PALM COAST, FL 32164 |
| Lot: 0210 |
| Contracted Stated Job Value: ¤9,200.00 |
| Job Description: HVAC LIKE FOR LIKE TONNAGE |
| Type: CN |
Contractor
AA SERVICE AND REPAIR NORTH FLORIDA AC
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
PO BOX 57896 JACKSONVILLE, FL 32258 |
CMC1249701 (Exp: 08/31/2026) | 904-610-4499 | 904-288-8164 |
Inspection History
| Type | Request Date | Result | Inspector |
| HVAC FINAL | 08/20/2025 | FINAL APPROVED | MKRASKI |
| Note: | |||
| HVAC FINAL | 08/01/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 8/1/2025 11:12:45 AM *** 8/1/25: 1). Disconnect for ODU has an unused opening that needs to be plugged as required. NEC 408.7 (Unused Openings). 2). MC 90* at AHU is missing the locknut as required. NEC-376.100(B). 3). Supply duct needs to be sealed where it enters the attic. FBC EC TABLE R402.4.1.1 / FBC-R302.11(4). |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | INFORMATION | 07/31/2025 | 07/31/2025 |
| Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM NOC ONLY NEED FOR HVAC ESTIMATES OVER $15000 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/18/2025 |
| SURCHARGE FS 533.721 | ¤2.00 | 07/30/2025 |
| SURCHARGE - FS 468.631 | ¤2.00 | 07/30/2025 |
| ADJUSTMENT 10% | (¤9.00) | 07/30/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 07/30/2025 |
| INSPECTION - MECHANICAL | ¤60.00 | 07/30/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤125.00 |